Animal Experiment Instruments
Filter
Showing 361–390 of 890 results
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | IM-21 |
| Pricing | Upon Request |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | IM-21 |
| Plunger Travel | 20 mm |
| Full-Rotation Volume Displacement | ~10 µL |
| Micrometer Resolution | 0.5 µm per division (500 µm per full knob rotation) |
| Dimensions | W127–147 × D55 × H78 mm |
| Weight | 620 g |
| Tubing Length | 1 m |
| Accessories | IM-H3 Holder, HI01PK01 Silicone Pad, IMO4 O-Ring, Grease Kit |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | IM-300 |
| Pricing | Available Upon Request |
| Input Pressure | 400–700 kPa (60–100 psi) |
| Injection Pressure Range | 0.7–400 kPa (0.1–60 psi) |
| Balance Pressure Range | 0–70 kPa (0–10 psi) |
| Time Setting Resolution | 10 ms – 327.66 s |
| Count Setting Range | 1–255 |
| Power Supply | AC 100–120 V ±5% / 220–240 V ±5%, 50/60 Hz |
| Power Consumption | ~25 W |
| Dimensions (W×D×H) | 425 × 205 × 90 mm |
| Weight | 3.7 kg |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | IM-400 |
| Pricing | Available Upon Request |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IM-6 |
| Plunger Stroke | 40 mm |
| Knob Full Rotation Displacement | 500 µm |
| Maximum Syringe Volume | 800 µL |
| Knob Full Rotation Volume Increment | ~10 µL |
| Dimensions (W×D×H) | 200 × 80 × 130 mm |
| Weight | 2 kg |
| Accessories | IM-H1 Syringe Holder, O-rings, Silicone Rubber Pad, IM-AS-2 Oil Add-on Kit |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IMS-20 |
| Price Range | USD 1,400 – 7,000 |
| Syringe Compatibility | Hamilton series (75, 701–725, 1701–1725, 7000.5–7105) and equivalent glass/metal syringes with outer diameter 6.5–9.0 mm |
| Motor Type | Precision Stepper Motor |
| Total Travel | 60 mm |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | 10 W |
| Pump Dimensions/Weight | 30 × 167 × 84 mm / 426 g |
| Controller Dimensions/Weight | 180 × 95 × 260 mm / 2.45 kg |
| Included Cables | Power cord (1.5 m), Data cable (2 m) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | MAG-3, MAG-2, MAG-1, SR-9AM, MA-6N, SRP-AM2, SR-AM |
| Load Capacity | 0.5–2 kg |
| Tilt Range (Longitudinal/Lateral) | ±10°–±15° / ±15°–±20° |
| Material | Anodized Aluminum, Medical-Grade Acrylic, MRI-Compatible Non-Metallic Polymers |
| Compliance | Designed for ISO 13485-aligned laboratory environments |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MF2 |
| Price | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MO-10 |
| Pricing | Available Upon Request |
| Fine Adjustment Travel | 10 mm |
| Micrometer Step per Revolution | 500 µm |
| Graduation Resolution | 2 µm |
| Joystick X–Y Planar Travel | 2 mm |
| Control Unit Dimensions (W×D×H) | 70 × 115 × 100 mm, 1.15 kg |
| Drive Unit Dimensions (W×D×H) | 30 × 20 × 125 mm, 50 g |
| Hydraulic Tubing Length | 1.5 m |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Variants | MO-97A, MO-97, MO-96A, MO-95, MO-903 |
| Pricing | Upon Request |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | NT-88-V3 |
| Compatibility | Nikon TI-series inverted microscopes (including TI-E, TI-U, TI-S) |
| Design Type | Hydraulic coarse/fine integrated manipulator |
| Control Interface | Ergonomic joystick with height adjustment |
| Vibration Damping | Enhanced microscope mounting interface with mechanical isolation |
| Position Memory | “Co-location” function for rapid needle repositioning |
| Axis Indication | Independent X, Y, Z vernier scales for precise coordinate referencing |
| Weight | Reduced vs. NT-88-NE |
| Footprint | Compact form factor optimized for multi-manipulator setups |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | PC-100 |
| Capillary OD Range | 1.0–2.0 mm |
| Capillary Length Range | 50–260 mm |
| Heating Element | Cr-Al-Co Resistance Wire |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | ~70 W |
| Max Coil Voltage | 2.5 V |
| Standard Weights | 25 g × 2, 100 g × 2 |
| Dimensions (L×W×H) | 205 × 190 × 185 mm |
| Weight | 3.45 kg |
| Display | Real-time digital readout of heating output (0–100 scale), elapsed time, and operational status |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | PE-22 |
| Power Supply | AC 100–240 V (±5%), 50/60 Hz |
| Max. Power Consumption | ~500 W |
| Filament Current | ~17 A |
| Filament Voltage | ~6 V |
| Dimensions (W×D×H) | 280 × 280 × 610 mm |
| Weight | 20.7 kg |
| Capillary Compatibility | 2–6 mm OD (standard) |
| Heating & Magnet Output Control | Digital display (0–100 scale) |
| Safety | Integrated metal shield, reinforced heater–axis coupling, fail-safe microswitch calibration |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | SMM-100 / SMM-100C / SMM-200 / SMM-200C / SR-5M1-HT / SR-9M-HT / SM-15R/L / SM-25A/SM-25C / SGM-3/SGM-4 / MAG-1/MAG-2/MAG-A / GM-3/GM-4 |
| Application Scope | Mouse, Rat, Neonatal Rat, Marmoset |
| Compliance | Designed for GLP-compliant acute and chronic in vivo neuroscience studies |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SR-5M / SR-6M |
| Price Range | USD 1,400 – 7,000 |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SRS-A |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | STS-A |
| Pricing | Available Upon Request |
| Dimensions (W × D × H) | 170 × 115 × 82–112 mm |
| Weight | 80 g |
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | STS-B |
| Pricing | Upon Request |
| Attachment Components | Mounting Ring, Securing Screws, Hex Key |
| Dimensions (W × D × H) | 205 × 140 × 95–125 mm |
| Weight | 1.18 kg |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | 68506 |
| Pricing | Upon Request |
| Base Plate Dimensions | 400 mm × 255 mm |
| Ear Bar Angle | 18° |
| Ear Bar Scale Resolution | 0.1 mm |
| Ear Bar Height from Base | 55.5 mm |
| Track Length | 255 mm |
| Track Zero Alignment | Coincident with Ear Bar Center |
| Track Graduation Range | ±100 mm from Zero |
| Adapter Anterior–Posterior Travel | 43.5 mm |
| Adapter Vertical Adjustment Range | +10 mm to –20 mm (30 mm total) |
| Vertical Adjustment Resolution | 0.1 mm |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NeuroStar LA-Stereo |
| Price Range | USD 7,000 – 14,000 |
| Track Travel Range | ±100 mm (200 mm total), 0.1 mm resolution |
| Positioning Accuracy | 100 µm (vernier scale readout) |
| Arm Rotation | Vertical ±90°, Horizontal 360° |
| Max. Mounted Arms | 6 (dual parallel rail system) |
| Upgrade Option | Digital Readout (DRO) Kit Available |
| Animal Compatibility | Canis lupus familiaris, Macaca fascicularis, Sus scrofa, Rattus norvegicus, Mus musculus (with species-specific adapters) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Lite Series |
| Quotation | Available Upon Request |
| Base Plate Dimensions | 400 mm × 255 mm |
| Inter-aural Rod Height Above Base | 35.5 mm |
| Ear Bar Groove Scale Resolution | 0.1 mm |
| Ear Bar Graduation Range | 35 mm (1 mm graduation) |
| Adapter Anterior–Posterior Travel | 43.5 mm |
| Adapter Vertical Adjustment Range | 30 mm (−20 mm to +10 mm), 0.1 mm resolution |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NeuroStar Lite Mouse Stereotaxic Instrument |
| Pricing | Available Upon Request |
| Base Plate Dimensions | 255 mm × 255 mm |
| Ear Bar Material | Polyoxymethylene (POM) |
| Incisor Bar Vertical Adjustment Range | 0–20 mm |
| Ear Bar Vertical Adjustment Range | 0–20 mm |
| Ear Bar Graduation Scale | 1 mm resolution |
| Included Ear Bars | Two pairs — 18° and 45° blunt-tipped |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VisioTracker by NewBehavior |
| Pricing | Available Upon Request |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SCIENTZ03-II |
| Pricing | Available Upon Request |
| UV Wavelength | 254 nm |
| Optional Blue Light Source | 470 nm (for gel visualization) |
| Active Irradiation Area | 880 cm² |
| Dose Control | Microprocessor-regulated energy mode (J/cm²) and time mode |
| Safety Features | Interlocked safety door with UV-blocking viewing window |
| Operation Interface | LED display with auto-memory function |
| Design | Drawer-type sample chamber |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Field Strength | 1.0 T |
| Minimum Slice Thickness | 0.8 mm |
| Animal Weight Capacity | 1–45 g |
| Sample Diameter Limit | < 40 mm |
| Minimum Sample Volume | ≥ 100 µL |
| Scan Orientation | Arbitrary Angle & Arbitrary Plane |
| Compliance | Designed for Preclinical GLP-Compatible Workflow |
| Optional Modules | Gas Anesthesia System, ROI Analysis Software Suite |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) System |
| Static Field Strength | 1.0 ± 0.05 T |
| Larmor Frequency | ~42 MHz |
| Bore Diameter | 60 mm |
| Application Scope | In vivo MRI of mice and rats using MR contrast agents |
| Target Applications | Spontaneous tumor detection (brain, subcutaneous, liver), longitudinal tumor growth & therapy response monitoring, obesity phenotyping, MR contrast agent development |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H+ |
| Pricing | Upon Request |
| Magnetic Field Strength | 1.0 ± 0.05 T |
| Larmor Frequency | ~42 MHz |
| Animal RF Coil ID | 60 mm |
| Primary Applications | In vivo murine MRI for oncology, obesity, contrast agent development, and longitudinal disease modeling |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NM42-060H-I |
| Quotation | Upon Request |
| Magnetic Field Strength | 1.0 ± 0.05 T |
| Larmor Frequency | ~42 MHz |
| Dedicated Animal RF Coil Diameter | 60 mm |
| Species Compatibility | Live mice and rats |
| Primary Application | In vivo glioma modeling, tumor progression monitoring, therapeutic response assessment, contrast agent evaluation |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H-I |
| Magnetic Field Strength | 1.0 ± 0.05 T |
| Larmor Frequency | ~42 MHz |
| Gradient Coil Bore Diameter | 60 mm |
| Magnet Type | Permanent Magnet |
| Application Scope | In vivo small animal MRI (mouse/rat), contrast agent evaluation, tumor monitoring (brain, subcutaneous, liver), obesity phenotyping, longitudinal therapeutic response assessment |
| Compliance | Designed for GLP-aligned preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42+ |
| Instrument Type | Preclinical MRI System for Rodent Research (Mouse/Rat) |
| Resonance Frequency | ~42 MHz |
| Static Magnetic Field Strength | 1.0 ± 0.05 T |
| Bore Diameter | 60 mm (Dedicated Animal RF Coil) |
| Magnet Type | Permanent Magnet |
| Application Scope | In vivo cell tracking, contrast agent evaluation, tumor modeling, metabolic phenotyping, longitudinal studies in mice and rats |
