BrandAnton Paar
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelChemBET Pulsar
Instrument TypeChemisorption Analyzer
Measurement PrincipleFully Automated Flow Method
Gas Inlet Ports5 (expandable to 6 with optional gas mixer)
Temperature RangeAmbient to 1100 °C
Heating Rate1–50 °C/min (programmable in multiple segments)
Analytical FunctionsTPR, TPD, TPO, Pulse Titration
Sample Stations2 (1 analysis + 1 preparation)
Quantitative Loop Volumes50, 100, 250 µL (custom volumes available)
DetectorHigh-Stability TCD with oxidation- and NH₃-resistant filament
Sample Tube OptionsU-shaped quartz, Pyrex®, or borosilicate
Steam TrapIntegrated between sample tube and detector
GC/MS Interface Ports3 configurable locations (post-sample, post-trap/pre-detector, post-detector)
Surface Area Range0.01–280 m²/g
Total Pore Volume1×10⁻⁴–1.5×10⁻¹ cm³
Volume Accuracy±1%
Repeatability±0.5%
Compatible GasesH₂, O₂, CO, NO, SO₂, NH₃ (chemisorption)
Cooling Time (1100 °C → 100 °C)< 30 min
Dimensions (W×H×D)45 × 63 × 42 cm
Weight24 kg
Operating Environment15–35 °C, 20–80% RH (non-condensing)
Power Supply100/120 V or 220/240 V AC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelAutosorb 6200
Instrument TypeChemisorption Analyzer
Measurement PrincipleVolumetric Vacuum Method (Physical & Chemical Adsorption), Dynamic Flow Method (Optional for Chemisorption)
Gas Inlet Ports6
Maximum Heating Temperature1100 °C
Isothermal Stability±1 °C
Heating Ramp Rate1–50 °C/min
Pressure Range2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K)
Analytical CapabilitiesTemperature-Programmed Reduction (TPR), Temperature-Programmed Oxidation (TPO), Temperature-Programmed Desorption (TPD), Pulse Titration
Detection OptionsIntegrated TCD, Optional Mass Spectrometer (MS), Optional Vapor Generator
Sample Stations1–3 Independent Physical Adsorption Stations + 1 Dedicated Chemisorption Station + 1 Dedicated p₀ Station
TruZone Active Liquid-Level ControlYes
PowderProtect Anti-Dust SystemYes
Dewar Duration>90 h (LN₂)
Integrated Degassing Stations6 (2 independently heated to 450 °C)
Cryosync CompatibilityOptional
Vapor SourceOptional
Cold TrapIntegrated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeChemisorption Analyzer
ModelAutosorb 6300
Gas Inlet Ports6
Maximum Heating Temperature1100 °C
Isothermal Stability±1 °C
Ramp Rate1–50 °C/min
Pressure Range2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K)
Analytical ModesTPR, TPO, TPD, Pulse Titration
DetectionIntegrated TCD, Optional Mass Spectrometer
Vapor SourceBuilt-in
Dewar Duration>90 h (LN₂)
Degassing Stations6 PID-controlled, up to 450 °C
TruZone Active Liquid-Level ControlYes
PowderProtect Anti-Dust SystemYes
Stainless Steel Manifold with Pneumatic ValvesYes
Vacuum Integrity Improvement38% vs. legacy designs
BET Surface Area Detection Limit0.01 m²/g (N₂, 77 K)
Pore Size Range0.35 nm – 500 nm
Metal Dispersion Detection Limit0.003 m² (H₂ on Pt, 313 K)