- All
- Favorite
- Popular
- Most rated
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ChemBET Pulsar |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Fully Automated Flow Method |
| Gas Inlet Ports | 5 (expandable to 6 with optional gas mixer) |
| Temperature Range | Ambient to 1100 °C |
| Heating Rate | 1–50 °C/min (programmable in multiple segments) |
| Analytical Functions | TPR, TPD, TPO, Pulse Titration |
| Sample Stations | 2 (1 analysis + 1 preparation) |
| Quantitative Loop Volumes | 50, 100, 250 µL (custom volumes available) |
| Detector | High-Stability TCD with oxidation- and NH₃-resistant filament |
| Sample Tube Options | U-shaped quartz, Pyrex®, or borosilicate |
| Steam Trap | Integrated between sample tube and detector |
| GC/MS Interface Ports | 3 configurable locations (post-sample, post-trap/pre-detector, post-detector) |
| Surface Area Range | 0.01–280 m²/g |
| Total Pore Volume | 1×10⁻⁴–1.5×10⁻¹ cm³ |
| Volume Accuracy | ±1% |
| Repeatability | ±0.5% |
| Compatible Gases | H₂, O₂, CO, NO, SO₂, NH₃ (chemisorption) |
| Cooling Time (1100 °C → 100 °C) | < 30 min |
| Dimensions (W×H×D) | 45 × 63 × 42 cm |
| Weight | 24 kg |
| Operating Environment | 15–35 °C, 20–80% RH (non-condensing) |
| Power Supply | 100/120 V or 220/240 V AC, 50/60 Hz |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Autosorb 6200 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Volumetric Vacuum Method (Physical & Chemical Adsorption), Dynamic Flow Method (Optional for Chemisorption) |
| Gas Inlet Ports | 6 |
| Maximum Heating Temperature | 1100 °C |
| Isothermal Stability | ±1 °C |
| Heating Ramp Rate | 1–50 °C/min |
| Pressure Range | 2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K) |
| Analytical Capabilities | Temperature-Programmed Reduction (TPR), Temperature-Programmed Oxidation (TPO), Temperature-Programmed Desorption (TPD), Pulse Titration |
| Detection Options | Integrated TCD, Optional Mass Spectrometer (MS), Optional Vapor Generator |
| Sample Stations | 1–3 Independent Physical Adsorption Stations + 1 Dedicated Chemisorption Station + 1 Dedicated p₀ Station |
| TruZone Active Liquid-Level Control | Yes |
| PowderProtect Anti-Dust System | Yes |
| Dewar Duration | >90 h (LN₂) |
| Integrated Degassing Stations | 6 (2 independently heated to 450 °C) |
| Cryosync Compatibility | Optional |
| Vapor Source | Optional |
| Cold Trap | Integrated |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Chemisorption Analyzer |
| Model | Autosorb 6300 |
| Gas Inlet Ports | 6 |
| Maximum Heating Temperature | 1100 °C |
| Isothermal Stability | ±1 °C |
| Ramp Rate | 1–50 °C/min |
| Pressure Range | 2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K) |
| Analytical Modes | TPR, TPO, TPD, Pulse Titration |
| Detection | Integrated TCD, Optional Mass Spectrometer |
| Vapor Source | Built-in |
| Dewar Duration | >90 h (LN₂) |
| Degassing Stations | 6 PID-controlled, up to 450 °C |
| TruZone Active Liquid-Level Control | Yes |
| PowderProtect Anti-Dust System | Yes |
| Stainless Steel Manifold with Pneumatic Valves | Yes |
| Vacuum Integrity Improvement | 38% vs. legacy designs |
| BET Surface Area Detection Limit | 0.01 m²/g (N₂, 77 K) |
| Pore Size Range | 0.35 nm – 500 nm |
| Metal Dispersion Detection Limit | 0.003 m² (H₂ on Pt, 313 K) |
Show next