| Brand | Quantachrome |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Cryosync |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Gas Adsorption |
| Operating Ambient Temperature | 15–35 °C |
| Temperature Control Range (with LN₂) | 82–115 K |
| Stability | ±0.005 K (s.d.) |
| Hold Time at 87.3 K | >50 h without refilling |
| Dimensions (Controller only) | 170 × 95 × 100 mm |
| Weight (Controller) | 0.9 kg |
| Power Supply | 100–240 V AC, 50–60 Hz, ≤30 W, Grounded Single-Phase |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Litesizer DLS Series |
| Particle Size Range | 0.3 nm – 15 µm (DLS, DLS 701) |
| Size Reproducibility | ±2% |
| Temperature Control Range | 0–120 °C |
| Temperature Stability | ±0.1 °C |
| Laser Frequency | 455 THz (658 nm diode laser) |
| Particle Sizing Method | Dynamic Light Scattering (DLS) and Static Light Scattering (SLS) |
| Sample Volume | 1.5 µL – 1 mL |
| Sample Concentration | up to 50% w/v |
| Zeta Potential Range | ±1000 mV |
| Measurement Time | < 60 s |
| Molecular Weight Range | 300 Da – 20 MDa |
| Zeta Potential Reproducibility | ±3% |
| Refractive Index Accuracy | ±0.5% (for DLS 701/501) |
| Transmission Monitoring | 0–100%, resolution <1% |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ViscoQC 300 |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–320 mPa·s |
| Temperature Control Range | +15 °C to +80 °C (with PTD 80, DIN/SSA geometry) |
| Compliance Standards | ASTM D2196, ISO 2555, ISO 3219, ISO 16520, USP <911>, EN ISO 12058 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RheolabQC |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1 – 10⁹ mPa·s |
| Temperature Range | −20 to +180 °C |
| Speed Range | 0.01 – 1500 rpm |
| Torque Range | 0.25 – 75 mN·m |
| Shear Stress Range | 0.5 – 3×10⁴ Pa |
| Shear Rate Range | 0.01 – 4000 s⁻¹ |
| Angular Displacement Resolution | 2 µrad |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | MCT³ |
| Instrument Type | Micro/Nano Scratch and Indentation Tester |
| Maximum Indentation Depth | 1000 µm |
| Effective Load Range | 30 N |
| Load Resolution | 6 µN |
| Displacement Resolution | 0.05 nm |
| Load Noise (RMS) | 100 µN |
| Depth Noise (RMS) | 1.5 nm |
| Data Acquisition Rate | 192 kHz |
| Scratch Speed Range | 0.1–600 mm/min |
| Depth Measurement Range | 1000 µm |
| Depth Resolution | 0.03 nm |
| Optional Modules | Peltier Stage (−120 °C to +120 °C), Heated Stage (up to 200 °C), Liquid Environment Cell |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 4200M |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0002 g/cm³ |
| Density Repeatability (s.d.) | ±0.00005 g/cm³ |
| Digital Resolution | 0.00001 g/cm³ |
| Temperature Range | −10 °C to 200 °C (14 °F to 392 °F) |
| Pressure Range | 0–500 bar (7250 psi) |
| Minimum Sample Volume | 2 mL |
| Viscosity Correction | Fully Automated, Real-Time |
| Filling Verification | FillingCheck™ |
| Thermal Equilibration Technology | Temperfect™ |
| Oscillation Excitation Method | Pulsed Excitation Method (Patent AT 516420 B1) |
| Wetted Materials | Hastelloy C-276 |
| Compliance Standards | ASTM D4052, ASTM D5002, GB/T 29617 |
| Power Supply | AC 100–240 V, 50–60 Hz, 250 VA |
| Interface Ports | 4× USB 2.0, 1× Ethernet (100 Mbit), 1× CAN Bus, 1× RS-232, 1× VGA, 1× 1/8″ OD metal pressure fitting |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Autosorb 6100 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 |
| Specific Surface Area Range | 0.01 m²/g to unlimited |
| Pressure Range | 2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K) |
| Theoretical Basis | Vacuum Volumetric Method |
| Reproducibility | <1% RSD (per BAM Reference Material P115) |
| Ambient Operating Temperature | 15–35 °C |
| Temperature Control Accuracy | ±0.05 °C |
| Vacuum System | Dual-stage — Diaphragm Pump + Turbo-Molecular Pump |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SmartMelt 92/303 |
| Instrument Type | Rotational Rheometer |
| Sample Type | High-Viscosity |
| Sample State | Liquid |
| Motor Bearing | Precision Porous Carbon Air Bearing |
| Temperature Range | −150 °C to +400 °C |
| Frequency Range | 10⁻⁷ Hz to 628 rad/s (≈100 Hz) |
| Minimum Rotational Speed | 10⁻⁴ rpm |
| Maximum Torque | 215 mNm |
| Maximum Rotational Speed | 3000 rpm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MCR 303 / MCR 503 / MCR 503 Power |
| Instrument Type | Rotational Rheometer |
| Sample Viscosity Range | High-Viscosity Fluids |
| Sample State | Liquid |
| Motor Bearing | Precision Porous Carbon Air Bearing |
| Temperature Range | –160 °C to 1000 °C |
| Frequency Range | 2 × 10⁻⁸ Hz to 200 Hz |
| Minimum Rotational Speed | 0 rpm |
| Maximum Torque | 300 mNm |
| Maximum Rotational Speed | 3000 rpm |
| Torque Resolution | 0.05 nNm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MCR 72 / MCR 92 |
| Instrument Type | Rotational Rheometer |
| Sample State | Solid, Semi-Solid, Paste, Gel, Molten Polymer |
| Bearing System | Ball Bearing (MCR 72) / Air Bearing (MCR 92) |
| Temperature Range | –50 °C to +400 °C |
| Minimum Angular Velocity | 10⁻⁴ rad/s (≈0.001 rpm) |
| Maximum Angular Velocity | 157 rad/s (1500 rpm) |
| Frequency Range | 10⁻⁴ to 628 rad/s (0.0001–100 Hz) |
| Maximum Torque | 125 mNm |
| Torque Resolution | 100 nNm |
| Normal Force Control | SafeGap™ integrated |
| Optical Sample Observation | TruRay™ adjustable LED illumination |
| Tool Recognition | Toolmaster™ auto-identification for transducers and temperature units |
| Drive System | EC brushless DC motor with high-resolution optical encoder |
| Control Modes | Controlled Shear Stress (CSS), Controlled Shear Rate (CSR), Controlled Strain (CSA), Controlled Stress (CSD) |
| Compliance | ASTM D3835, ISO 6721-10, ISO 3219, USP <911>, FDA 21 CFR Part 11-ready software architecture |
| Brand | Anton Paar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Xsample Series |
| Sample Type | Liquid |
| Minimum Sample Volume | 5 mL / 10 mL (when coupled with DMA instruments) |
| Viscosity Range | up to 1000 mPa·s |
| Instrument Class | Benchtop Laboratory |
| Application Scope | Universal Density Measurement |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11–enabled software environments |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MCR 703 |
| Instrument Type | Rotational Rheometer |
| Sample Viscosity Range | High-Viscosity Fluids |
| Sample State | Liquid |
| Motor Bearing | Precision Porous Carbon Air Bearing |
| Frequency Range | 2 × 10⁻⁸ – 200 Hz |
| Minimum Rotational Speed | 0 rpm |
| Maximum Torque | 230 mNm |
| Maximum Rotational Speed | 6000 rpm |
| Torque Resolution | <1 nrad |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ViscoQC 100 |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–6,000,000 mPa·s (L), 10–40,000,000 mPa·s (R), 60–320,000,000 mPa·s (H) |
| Temperature Range | +15 °C to +80 °C |
| Temperature Accuracy | ±1.0 % of full scale |
| Speed Range | 0.1–200 rpm (19 standard + 6 user-definable speeds) |
| Torque Range | 0.067–75.7496 mN·m |
| Accuracy | ±1.0 % of full scale |
| Repeatability | ±0.2 % of full scale |
| Compliance | ISO 2555, ISO 3219, ASTM D2196, USP <911>, GMP/GLP-ready |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 0.01–3500 µm (DIF 500) / 0.1–2500 µm (DIF 300) / 0.1–1000 µm (DIF 100) |
| Repeatability | Better than ±0.5% RSD |
| Measurement Time | <10 s |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ChemBET Pulsar |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Fully Automated Flow Method |
| Gas Inlet Ports | 5 (expandable to 6 with optional gas mixer) |
| Temperature Range | Ambient to 1100 °C |
| Heating Rate | 1–50 °C/min (programmable in multiple segments) |
| Analytical Functions | TPR, TPD, TPO, Pulse Titration |
| Sample Stations | 2 (1 analysis + 1 preparation) |
| Quantitative Loop Volumes | 50, 100, 250 µL (custom volumes available) |
| Detector | High-Stability TCD with oxidation- and NH₃-resistant filament |
| Sample Tube Options | U-shaped quartz, Pyrex®, or borosilicate |
| Steam Trap | Integrated between sample tube and detector |
| GC/MS Interface Ports | 3 configurable locations (post-sample, post-trap/pre-detector, post-detector) |
| Surface Area Range | 0.01–280 m²/g |
| Total Pore Volume | 1×10⁻⁴–1.5×10⁻¹ cm³ |
| Volume Accuracy | ±1% |
| Repeatability | ±0.5% |
| Compatible Gases | H₂, O₂, CO, NO, SO₂, NH₃ (chemisorption) |
| Cooling Time (1100 °C → 100 °C) | < 30 min |
| Dimensions (W×H×D) | 45 × 63 × 42 cm |
| Weight | 24 kg |
| Operating Environment | 15–35 °C, 20–80% RH (non-condensing) |
| Power Supply | 100/120 V or 220/240 V AC, 50/60 Hz |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MCR 303 |
| Instrument Type | Rotational Rheometer |
| Sample Viscosity Range | High-Viscosity Liquids |
| Sample State | Liquid |
| Motor Bearing | Precision Porous Carbon Air Bearing |
| Temperature Range | –160 °C to +1000 °C |
| Minimum Rotational Speed | 0 rpm |
| Frequency Range | 2 × 10⁻⁸ Hz to 100 Hz |
| Maximum Rotational Speed | 3000 rpm |
| Maximum Torque | 215 mNm |
| Torque Resolution | 0.1 nNm |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Autosorb 6200 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Volumetric Vacuum Method (Physical & Chemical Adsorption), Dynamic Flow Method (Optional for Chemisorption) |
| Gas Inlet Ports | 6 |
| Maximum Heating Temperature | 1100 °C |
| Isothermal Stability | ±1 °C |
| Heating Ramp Rate | 1–50 °C/min |
| Pressure Range | 2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K) |
| Analytical Capabilities | Temperature-Programmed Reduction (TPR), Temperature-Programmed Oxidation (TPO), Temperature-Programmed Desorption (TPD), Pulse Titration |
| Detection Options | Integrated TCD, Optional Mass Spectrometer (MS), Optional Vapor Generator |
| Sample Stations | 1–3 Independent Physical Adsorption Stations + 1 Dedicated Chemisorption Station + 1 Dedicated p₀ Station |
| TruZone Active Liquid-Level Control | Yes |
| PowderProtect Anti-Dust System | Yes |
| Dewar Duration | >90 h (LN₂) |
| Integrated Degassing Stations | 6 (2 independently heated to 450 °C) |
| Cryosync Compatibility | Optional |
| Vapor Source | Optional |
| Cold Trap | Integrated |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | Litesizer DLS 501 |
| Zeta Potential Range | ±1000 mV |
| pH Range | 2–12 |
| Temperature Range | 0–120 °C |
| pH Resolution | 0.01 |
| Temperature Resolution | 0.01 |
| Accuracy | ±3% (Zeta), ±2% (DLS), ±10% (Molecular Weight) |
| Repeatability | ±3% (Zeta), ±2% (DLS), ±5% (Molecular Weight) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Rotational Rheometer |
| Sample Viscosity Range | High-Viscosity Liquids |
| Temperature Range | –160 °C to +1000 °C |
| Frequency Range | 0.001–628 rad/s |
| Maximum Rotational Speed | 2100 rpm |
| Bearing System | Precision Multi-Pore Carbon Air Bearing |
| Sample Capacity | Up to 54 Samples |
| Automation Level | Fully Automated, Barcode-Enabled, Integrated Cleaning & Temperature Control |
| Compliance | Designed for GLP/GMP environments |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SVM 3001 Cold Properties |
| Instrument Category | Multiparameter Physical Property Analyzer |
| Instrument Type | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.2–30,000 mm²/s |
| Temperature Range | −60 °C to +100 °C |
| Compliance | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1), AT516302 (B1), CN105628550 |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | RST 300 |
| Instrument Type | Micro/Nano Scratch Tester |
| Maximum Indentation Depth | 100 / 1000 µm |
| Effective Normal Load Range | 100 / 200 N |
| Load Resolution | 100 µN |
| Displacement Resolution | 0.05 / 0.5 nm |
| Maximum Friction Force | 100 / 200 N |
| Friction Resolution | 0.1 / 0.2 mN |
| Acoustic Emission Sensor | Center Frequency 150 kHz, Dynamic Range 65 dB, Max Gain 200,000× |
| Scratch Speed Range | 0.4 – 600 mm/min |
| Scratch Length | Up to 70 mm |
| In-situ Scratch Inspection Length | Up to 30 mm |
| Compliance | ASTM C1624, ISO 20502, ISO EN 1071 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | HPM |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Phase | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Repeatability | ≤0.00001 g/cm³ (standard deviation) |
| Temperature Range | −10 to +200 °C |
| Pressure Range | 0–1400 bar (0–20,300 psi) |
| Minimum Sample Volume | ~2 mL |
| Cell Material | Hastelloy C-276 |
| Digital Resolution | 0.00001 g/cm³ |
| Interface | 1/4″ metal tubing compression fittings |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Calotest Series |
| Instrument Type | Ball Cratering Tribological Coating Thickness Tester |
| Maximum Operating Temperature | Ambient (23 °C ± 2 °C) |
| Rotational Speed Range | 10–3000 rpm |
| Wear Time Range | 1–10000 s |
| Standard Ball Diameters | 10, 15, 20, 25.4, 30 mm |
| Measurable Coating Thickness Range | 0.1–50 µm |
| Applicable Standards | ISO 1071-2, VDI 3198 |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | UNHT³ HTV |
| Instrument Type | Ultra-Nanoindentation Tester |
| Maximum Indentation Depth | 100 µm |
| Effective Load Range | 100 mN |
| Load Resolution | 3 nN |
| Displacement Resolution | 0.003 nm |
| Thermal Drift (Ambient) | < 0.5 nm/min |
| Thermal Drift (Up to 800 °C) | < 3 nm/min |
| Frame Stiffness | > 10⁶ N/m |
| Frame Compliance | < 0.1 nm/mN |
| Vacuum Base Pressure | 1×10⁻⁷ mbar |
| Maximum Operating Temperature | 800 °C |
| Temperature Stability | ±0.1 °C (surface-controlled) |
| Compliance Standards | ISO 14577, ASTM E2546 |