Empowering Scientific Discovery

Anton Paar (Shanghai) Trading Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelDMA 1002/1102 Petro
Instrument TypeOscillating U-tube Densimeter
Instrument CategoryPortable
Sample TypeLiquid
Density Range0 g/cm³ to 3 g/cm³
Density Accuracy±0.0001 g/cm³
Temperature Range15 °C to 100 °C (59 °F to 212 °F)
Temperature Accuracy±0.03 °C (from +15 °C to +100 °C)
Density Resolution5 significant digits
Viscosity Range (DMA 1102 only)–0.3 mm²/s to 1000 mm²/s
Viscosity Repeatability±0.2%
Minimum Sample Volume3.5 mL
Display7-inch TFT WVGA (800 × 480 px) PCAP touch screen
Dimensions (L×W×H)365 mm × 265 mm × 180 mm
Weight6.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelUltrapyc Series
Instrument TypeTrue Density Analyzer
Instrument ClassBenchtop Laboratory
Sample TypeSolids (bulk & granular), Powders, Pastes, Slurries, Foams
Density Accuracy≤0.015%
Display7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen
Temperature Range3–60 °C
Minimum Sample Volume0.1 cm³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelDMA 502
Instrument TypeOscillating U-tube Density Meter
Form FactorBenchtop Laboratory Instrument
Sample TypeLiquids and Low-Viscosity Suspensions
Density Range0 to 3 g/cm³
Density Accuracy±0.001 g/cm³
Density Repeatability±0.0002 g/cm³
Density Resolution0.0001 g/cm³
Temperature Range15–40 °C
Temperature Stability±0.1 °C
Minimum Sample Volume1 mL
Display7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen
Environmental CompensationAutomatic pressure, altitude, and ambient humidity correction
Data Storage5000 measurements
Method Library400 pre-validated methods
Conversion Tables140 built-in (alcohol, sugar, acids, API gravity, etc.)
ComplianceASTM D4052, ASTM D5002, USP <841>, EP/JP pharmacopoeial density requirements, FDA 21 CFR Part 11 (when used with AP Connect)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPerfume and Flavor Measurement System
Instrument TypeOscillating U-tube Densimeter
Instrument ClassBenchtop Laboratory
Sample TypeLiquid
Density Range0–3 g/cm³
Density Accuracy±0.01 g/cm³
Display10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen
Temperature Control Range0–100 °C
Minimum Sample Volume2 mL
Integrated ParametersDensity, Refractive Index, Optical Rotation, Colorimetry, Turbidity
AutomationFully Automated Sample Handling with Recovery (Xsample 5200/530), Integrated Cleaning & Drying
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelDMA 1102 Petro
Instrument TypeOscillating U-tube Densimeter
ApplicationPetroleum Products Density & Kinematic Viscosity Measurement
Detection MediumLiquid
Density Range0 g/cm³ to 3 g/cm³
Density Accuracy±0.0001 g/cm³
Density Resolution5 significant digits
Temperature Range15 °C to 100 °C (59 °F to 212 °F)
Temperature Stability±0.03 °C over full range
Viscosity Range−0.3 mm²/s to 1000 mm²/s
Viscosity Repeatability±0.2%
Minimum Sample Volume3.5 mL
Display7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen
Dimensions (L×W×H)365 × 265 × 180 mm
Weight6.6 kg
Power SupplyDC 24 V / 3 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelDMA 1002
Instrument TypeOscillating U-tube Densimeter
Form FactorBenchtop Laboratory Instrument
Sample TypeLiquid
Density Range0–3 g/cm³
Density Accuracy±0.0001 g/cm³
Density Repeatability±0.00005 g/cm³
Density Resolution0.00001 g/cm³
Temperature Range15–60 °C
Temperature Stability±0.02 °C
Minimum Sample Volume1 mL
Display7″ TFT WVGA Touchscreen (800 × 480 px, PCAP)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelDMA 6002 Sound Velocity
Instrument TypeOscillating U-tube Densimeter & Sound Velocity Analyzer
Form FactorBenchtop Laboratory Instrument
Sample TypeLiquids
Density Range0 g/cm³ to 3 g/cm³
Sound Velocity Range1000 m/s to 2000 m/s
Temperature Range0 °C to 100 °C (32 °F to 212 °F)
Pressure Range0 bar to 8 bar (0 psi to 116 psi)
Density Accuracy±0.000005 g/cm³
Density Repeatability (Std. Dev.)±0.000001 g/cm³
Sound Velocity Repeatability (Std. Dev.)±0.1 m/s
Density Reproducibility (Std. Dev.)±0.000005 g/cm³
Sound Velocity Reproducibility (Std. Dev.)±0.5 m/s
Density Resolution0.000001 g/cm³
Sound Velocity Resolution0.01 m/s
Minimum Sample Volume3.5 mL
Measurement ThroughputUp to 30 samples/hour
ComplianceISO 5725, ASTM D4052, ASTM D1250, ISO 12185, ISO 17025 (when operated with certified calibration standards)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelDMA 4002 / DMA 5002 / DMA 6002
Instrument TypeOscillating U-tube Densimeter
Instrument ClassBenchtop Laboratory Densimeter
Sample TypeLiquid
Density Range0 to 3 g/cm³
Density Accuracy±0.00005 g/cm³ (DMA 4002), ±0.00001 g/cm³ (DMA 5002, 0–1.05 g/cm³ at 15–20 °C), ±0.000005 g/cm³ (DMA 6002, full range)
Temperature Range0 °C to 100 °C
Temperature Accuracy±0.02 °C (DMA 4002), ±0.01 °C (DMA 5002 & DMA 6002, 15–20 °C)
Density Repeatability (Std. Dev.)0.00001 g/cm³ (DMA 4002), 0.000003 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002)
Density Resolution0.00001 g/cm³ (DMA 4002), 0.000005 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002)
Minimum Sample Volume1 mL
Display10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen
ComplianceASTM D4052, D5002, D1250
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelElaTest
Density Measurement Range0.8–2.6 g/cm³
Temperature Range0–40.0 °C
Repeatability±0.00001 g/cm³
Resolution0.0001 g/cm³
Minimum Sample Volume40–120 cm³
ApplicationDensity of uncured rubber and rubber compounds
Instrument TypeBenchtop Laboratory Densitometer
Detection PrinciplePneumatic (gas displacement) density measurement
ComplianceDesigned for GLP/GMP environments with audit-ready data handling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelModulyzer
PricingUpon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0