BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelAlex 301 / Alex 501
Instrument TypeBrewery-Specific Analyzer
ApplicationLaboratory Use
Alcohol RangeBeer 0.5–15 % v/v
Density Measurement Range0.9500–1.200 g/cm³
Accuracy (Alcohol)±0.25 % v/v (Alex 301), ±0.2 % v/v (Alex 501)
Repeatability (Alcohol)0.15 % v/v (Alex 301), 0.1 % v/v (Alex 501)
Density Accuracy±0.001 g/cm³
Density Repeatability (Std. Dev.)0.0007 g/cm³ (Alex 301), 0.0005 g/cm³ (Alex 501)
Density Resolution0.0001 g/cm³
Sample Volume40 mL
Dimensions (L × W × H)320 mm × 230 mm × 100 mm
Weight~2.4 kg
Operating Temperature10–32 °C
Sample Temperature Range15–25 °C (Alex 301), 10–30 °C (Alex 501)
Interfaces1× Bluetooth®, 1× RS-232 (9-pin D-sub), 1× USB-B
Power Supply100–240 V~, 50/60 Hz, ±10%, DC 15 V / 2.6 A
Power Consumption20 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelALAB 5000
Instrument TypeIntegrated Online Beverage Quality Analyzer & Cap Torque Tester
Application ModeIn-line / At-line
Measurement Time (Analytic)8 min per sample
Measurement Time (Torque)30 s per sample
Alcohol Content Range0–12 % v/v
pH Range0–14
Dimensions (L × W × H)1750 mm × 880 mm × 2430 mm
Weight900 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelPackaged Beer Measurement System
Instrument TypeDedicated Beer Analyzer
ApplicationLaboratory-Based Quality Control
Measurement Time3 min per sample
Alcohol Content Range0–12 % v/v
pH Range0–14
Dimensions (L × W × H)515 × 1200 × 1120 mm / 482 × 750 × 670 mm / 482 × 730 × 446 mm
Weight30 kg
Sampling TechnologyPressurized Direct Injection, No Sample Preparation Required
Sample Volume per Package260 mL
Throughput7 samples/hour or 15 samples/hour (depending on configuration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelTPO 5000
Instrument TypeBeer-Specific Analyzer
Application ModeOnline & Laboratory
Measurement Time4 min
Dimensions (L × W × H)515 × 590 × 1120 mm
Weight70 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model SeriesCarboQC, CboxQC, OxyQC (At-line Configuration)
Measurement Time2–3 min per sample
Dimensions (L × W × H)258 mm × 201 mm × 170 mm
Weight2.6 kg
Data Storage CapacityUp to 500 measurement datasets
Sample Volume150 mL
CO₂ Range0–12 g/L (0–6 vol%) at 30 °C
Dissolved O₂ Range0–4 ppm
Temperature Range−3 °C to 30 °C
Pressure Range0–10 bar
CO₂ Repeatability (s.d.)±0.005 vol%
O₂ Repeatability (s.d.)±2 ppb
O₂ Response Time (t₉₈%)20 s at 25 °C
Pressure Accuracy±0.01 bar
CO₂ Accuracy (s.d.)±0.05 vol%
O₂ Accuracy (s.d.)±4 ppb
Power SupplyAC 100–240 V, 50/60 Hz
Interfaces1 × USB (PC), 1 × RS-232 (printer or AP-SoftPrint)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelAlcolyzer Beer Analyzing System
Instrument TypeBeer-Specific Analyzer
Application TypeLaboratory
Measurement Time3 min
Alcohol Content0–12 % v/v
pH Range0–14
Dimensions (L × W × H)495 × 330 × 230 mm
Weight30 kg
TechnologyInfrared
Sample Volume per Test35 mL
Throughput15–20 samples/hour