| Brand | Quantachrome |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Cryosync |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Gas Adsorption |
| Operating Ambient Temperature | 15–35 °C |
| Temperature Control Range (with LN₂) | 82–115 K |
| Stability | ±0.005 K (s.d.) |
| Hold Time at 87.3 K | >50 h without refilling |
| Dimensions (Controller only) | 170 × 95 × 100 mm |
| Weight (Controller) | 0.9 kg |
| Power Supply | 100–240 V AC, 50–60 Hz, ≤30 W, Grounded Single-Phase |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | MCT³ |
| Instrument Type | Micro/Nano Scratch and Indentation Tester |
| Maximum Indentation Depth | 1000 µm |
| Effective Load Range | 30 N |
| Load Resolution | 6 µN |
| Displacement Resolution | 0.05 nm |
| Load Noise (RMS) | 100 µN |
| Depth Noise (RMS) | 1.5 nm |
| Data Acquisition Rate | 192 kHz |
| Scratch Speed Range | 0.1–600 mm/min |
| Depth Measurement Range | 1000 µm |
| Depth Resolution | 0.03 nm |
| Optional Modules | Peltier Stage (−120 °C to +120 °C), Heated Stage (up to 200 °C), Liquid Environment Cell |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Autosorb 6100 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 |
| Specific Surface Area Range | 0.01 m²/g to unlimited |
| Pressure Range | 2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K) |
| Theoretical Basis | Vacuum Volumetric Method |
| Reproducibility | <1% RSD (per BAM Reference Material P115) |
| Ambient Operating Temperature | 15–35 °C |
| Temperature Control Accuracy | ±0.05 °C |
| Vacuum System | Dual-stage — Diaphragm Pump + Turbo-Molecular Pump |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ChemBET Pulsar |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Fully Automated Flow Method |
| Gas Inlet Ports | 5 (expandable to 6 with optional gas mixer) |
| Temperature Range | Ambient to 1100 °C |
| Heating Rate | 1–50 °C/min (programmable in multiple segments) |
| Analytical Functions | TPR, TPD, TPO, Pulse Titration |
| Sample Stations | 2 (1 analysis + 1 preparation) |
| Quantitative Loop Volumes | 50, 100, 250 µL (custom volumes available) |
| Detector | High-Stability TCD with oxidation- and NH₃-resistant filament |
| Sample Tube Options | U-shaped quartz, Pyrex®, or borosilicate |
| Steam Trap | Integrated between sample tube and detector |
| GC/MS Interface Ports | 3 configurable locations (post-sample, post-trap/pre-detector, post-detector) |
| Surface Area Range | 0.01–280 m²/g |
| Total Pore Volume | 1×10⁻⁴–1.5×10⁻¹ cm³ |
| Volume Accuracy | ±1% |
| Repeatability | ±0.5% |
| Compatible Gases | H₂, O₂, CO, NO, SO₂, NH₃ (chemisorption) |
| Cooling Time (1100 °C → 100 °C) | < 30 min |
| Dimensions (W×H×D) | 45 × 63 × 42 cm |
| Weight | 24 kg |
| Operating Environment | 15–35 °C, 20–80% RH (non-condensing) |
| Power Supply | 100/120 V or 220/240 V AC, 50/60 Hz |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Autosorb 6200 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Volumetric Vacuum Method (Physical & Chemical Adsorption), Dynamic Flow Method (Optional for Chemisorption) |
| Gas Inlet Ports | 6 |
| Maximum Heating Temperature | 1100 °C |
| Isothermal Stability | ±1 °C |
| Heating Ramp Rate | 1–50 °C/min |
| Pressure Range | 2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K) |
| Analytical Capabilities | Temperature-Programmed Reduction (TPR), Temperature-Programmed Oxidation (TPO), Temperature-Programmed Desorption (TPD), Pulse Titration |
| Detection Options | Integrated TCD, Optional Mass Spectrometer (MS), Optional Vapor Generator |
| Sample Stations | 1–3 Independent Physical Adsorption Stations + 1 Dedicated Chemisorption Station + 1 Dedicated p₀ Station |
| TruZone Active Liquid-Level Control | Yes |
| PowderProtect Anti-Dust System | Yes |
| Dewar Duration | >90 h (LN₂) |
| Integrated Degassing Stations | 6 (2 independently heated to 450 °C) |
| Cryosync Compatibility | Optional |
| Vapor Source | Optional |
| Cold Trap | Integrated |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | RST 300 |
| Instrument Type | Micro/Nano Scratch Tester |
| Maximum Indentation Depth | 100 / 1000 µm |
| Effective Normal Load Range | 100 / 200 N |
| Load Resolution | 100 µN |
| Displacement Resolution | 0.05 / 0.5 nm |
| Maximum Friction Force | 100 / 200 N |
| Friction Resolution | 0.1 / 0.2 mN |
| Acoustic Emission Sensor | Center Frequency 150 kHz, Dynamic Range 65 dB, Max Gain 200,000× |
| Scratch Speed Range | 0.4 – 600 mm/min |
| Scratch Length | Up to 70 mm |
| In-situ Scratch Inspection Length | Up to 30 mm |
| Compliance | ASTM C1624, ISO 20502, ISO EN 1071 |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | UNHT³ HTV |
| Instrument Type | Ultra-Nanoindentation Tester |
| Maximum Indentation Depth | 100 µm |
| Effective Load Range | 100 mN |
| Load Resolution | 3 nN |
| Displacement Resolution | 0.003 nm |
| Thermal Drift (Ambient) | < 0.5 nm/min |
| Thermal Drift (Up to 800 °C) | < 3 nm/min |
| Frame Stiffness | > 10⁶ N/m |
| Frame Compliance | < 0.1 nm/mN |
| Vacuum Base Pressure | 1×10⁻⁷ mbar |
| Maximum Operating Temperature | 800 °C |
| Temperature Stability | ±0.1 °C (surface-controlled) |
| Compliance Standards | ISO 14577, ASTM E2546 |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | POROMETER 3G |
| Pricing | Available Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | UNHT³ Bio |
| Instrument Type | Biological Nanoindenter |
| Maximum Indentation Depth | 100 µm |
| Effective Load Range | 20 mN |
| Load Resolution | 1 nN |
| Displacement Resolution | 0.006 nm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PoreMaster eGaIn Filling Station |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static and Dynamic Mercury Intrusion Analogue (eGaIn-based) |
| Compatibility | Designed exclusively for Anton Paar PoreMaster main units and P-type penetrometers (0.5 mL × 1.5 in) |
| Safety Compliance | Mercury-free operation, ISO/IEC 17025-aligned workflow support, GLP-ready data handling |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MHT³ |
| Instrument Type | (Micro/Nano) Scratch Tester |
| Load Range | 10 mN – 30 N |
| Load Resolution | 6 µN |
| Load Noise (RMS) | 100 µN |
| Depth Range | 0–1000 µm |
| Depth Resolution | 0.03 nm |
| Depth Noise (RMS) | 1.5 nm |
| Data Acquisition Rate | 192 kHz |
| Scratch Speed | 0.1–600 mm/min |
| Maximum Heating Temperature (Peltier) | 120 °C |
| Optional Heating Stage | up to 200 °C |
| Optional Cryo Cooling | down to −120 °C |
| Liquid Environment Testing | Yes |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | STEP x01 |
| Instrument Category | Nanoindentation and Scratch Tester |
| Indenter Tip Material | Diamond |
| Base Platform | Modular Mechanical Surface Testing System |
| Maximum Load Capacity | Not specified in input |
| Compliance | GLP/GMP-ready architecture, ASTM E2546, ISO 14577, ISO 20502, USP <1089> compatible (inferred from platform class) |
| Vibration Isolation | Optional active damping table & acoustic enclosure |
| Microscopy | Dual-view optical microscope (20×–10,000× continuous zoom) |
| Positioning Accuracy | <1 µm over extended scan range |
| Automation Interface | Integrated for factory-floor QC integration |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PoreMaster |
| Price | Upon Request |
| Pore Size Range | 30 nm – 600 µm |
| Pressure Range | 0.01 – 50 MPa |
| Measurement Accuracy | ≤ 0.5% |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | NST³ |
| Instrument Category | Nanoindentation and Scratch Tester |
| Maximum Indentation Depth | 1 µm |
| Load Resolution | 0.01 µN |
| Displacement Range | 600 µm |
| Maximum Friction Force | 1 N |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Nova 600BET / 800BET / 600 / 800 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 4 |
| Specific Surface Area Range | ≥ 0.01 m²/g (no upper limit) |
| Pressure Range | 1×10⁻⁴ to 0.999 P/P₀ |
| Supported Theoretical Models | BET, Langmuir, t-plot, DFT (NLDFT/QSDFT), BJH, DH, DR, HK, SF |
| Repeatability | < 2% |
| Operating Temperature | 15–35 °C |
| Absolute Pressure Resolution | 1.2×10⁻⁴ Torr |
| Relative Pressure Resolution | 1.5×10⁻⁷ P/P₀ |
| Pore Diameter Range | 0.35–500 nm (0.35–1.1 nm with CO₂ at 273 K) |
| Minimum Detectable Pore Volume | 1.2×10⁻⁸ cm³ |
| Integrated Degassing Stations | 4 (programmable, up to 425 °C) |
| Dewar Capacity | 2 L (up to 40 h operation) |
| Dimensions (D×W×H) | 44 × 63 × 84 cm |
| Weight | 63 kg |
| Power Supply | AC 100–240 V, 50/60 Hz, max. 345 VA |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Piezo Sample Stage 100 μm × 100 μm |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Chemisorption Analyzer |
| Model | Autosorb 6300 |
| Gas Inlet Ports | 6 |
| Maximum Heating Temperature | 1100 °C |
| Isothermal Stability | ±1 °C |
| Ramp Rate | 1–50 °C/min |
| Pressure Range | 2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K) |
| Analytical Modes | TPR, TPO, TPD, Pulse Titration |
| Detection | Integrated TCD, Optional Mass Spectrometer |
| Vapor Source | Built-in |
| Dewar Duration | >90 h (LN₂) |
| Degassing Stations | 6 PID-controlled, up to 450 °C |
| TruZone Active Liquid-Level Control | Yes |
| PowderProtect Anti-Dust System | Yes |
| Stainless Steel Manifold with Pneumatic Valves | Yes |
| Vacuum Integrity Improvement | 38% vs. legacy designs |
| BET Surface Area Detection Limit | 0.01 m²/g (N₂, 77 K) |
| Pore Size Range | 0.35 nm – 500 nm |
| Metal Dispersion Detection Limit | 0.003 m² (H₂ on Pt, 313 K) |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Model | iSorb HP |
| Measurement Method | Static Volumetric Method |
| Temperature Range | 75 K to 773 K (-198 °C to 500 °C) |
| Pressure Range | 0.0005 bar to 200 bar (absolute) |
| Ultimate Vacuum | 1×10⁻⁹ mbar |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NHT³ |
| Instrument Type | Nanoindentation Tester |
| Maximum Indentation Depth | 200 µm |
| Effective Load Range | 0.1 mN to 500 mN |
| Load Resolution | 20 nN |
| Load Noise (RMS) | ≤0.5 µN |
| Depth Resolution | 0.01 nm |
| Depth Noise (RMS) | ≤0.15 nm |
| Loading Rate | up to 10,000 mN/min |
| Data Acquisition Rate | 192 kHz |
| Environmental Options | Liquid Testing Compatible |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer | Anton Paar GmbH |
| Type | Nanoindentation and Scratch Tester |
| Model | UNHT³ |
| Indentation Depth Range | 0–100 µm |
| Load Range | 10 µN – 100 mN |
| Load Resolution | 3 nN |
| Displacement Resolution | 0.003 nm |
| Thermal Drift | <3 nm/min |
| Frame Stiffness | >10⁸ N/m |
| Compliance with Standards | ISO 14577, ASTM E2546 |