| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TPO 5000 |
| Instrument Type | Beer-Specific Analyzer |
| Application Mode | Online & Laboratory |
| Measurement Time | 4 min |
| Dimensions (L × W × H) | 515 × 590 × 1120 mm |
| Weight | 70 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model Series | CarboQC, CboxQC, OxyQC (At-line Configuration) |
| Measurement Time | 2–3 min per sample |
| Dimensions (L × W × H) | 258 mm × 201 mm × 170 mm |
| Weight | 2.6 kg |
| Data Storage Capacity | Up to 500 measurement datasets |
| Sample Volume | 150 mL |
| CO₂ Range | 0–12 g/L (0–6 vol%) at 30 °C |
| Dissolved O₂ Range | 0–4 ppm |
| Temperature Range | −3 °C to 30 °C |
| Pressure Range | 0–10 bar |
| CO₂ Repeatability (s.d.) | ±0.005 vol% |
| O₂ Repeatability (s.d.) | ±2 ppb |
| O₂ Response Time (t₉₈%) | 20 s at 25 °C |
| Pressure Accuracy | ±0.01 bar |
| CO₂ Accuracy (s.d.) | ±0.05 vol% |
| O₂ Accuracy (s.d.) | ±4 ppb |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Interfaces | 1 × USB (PC), 1 × RS-232 (printer or AP-SoftPrint) |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | TAG 300/500 |
| Detection Method | Closed-Cup (TAG) |
| Operation Mode | Fully Automatic |
| Sample Temperature Range | −35 °C to +130 °C |
| Ignition Source | Ceramic-Coated Electric Igniter |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Alcolyzer Beer Analyzing System |
| Instrument Type | Beer-Specific Analyzer |
| Application Type | Laboratory |
| Measurement Time | 3 min |
| Alcohol Content | 0–12 % v/v |
| pH Range | 0–14 |
| Dimensions (L × W × H) | 495 × 330 × 230 mm |
| Weight | 30 kg |
| Technology | Infrared |
| Sample Volume per Test | 35 mL |
| Throughput | 15–20 samples/hour |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Betalyser |
| Price | Upon Request |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar TorqueTec GmbH (formerly Brabender GmbH) |
| Model | TwinLab Series |
| Configuration Options | Twin-screw extruder, single-screw extruder (e.g., 19/25 mm), batch mixer |
| Throughput Range | 0.05–100 kg/h |
| Drive System | MetaStation modular drive unit |
| Control Software | MetaBridge v3.x |
| Barrel Design | Split-barrel with quick-release liner |
| Material Contact Parts | Wear- and corrosion-resistant high-alloy steel (up to 500 °C service temperature) |
| Compliance | Designed for GLP/GMP-aligned R&D environments |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Aquatrac-V |
| Measurement Principle | Calcium Hydride Reaction under Vacuum |
| Compliance | DIN EN ISO 15512:2019 |
| Resolution | 0.0001% H₂O (w/w) |
| Application Scope | Polymer Residual Moisture Analysis & MFR Sample Conditioning |
| Software | Aquatrac Control Software with Audit Trail, LIMS/ERP Integration Capability |
| Regulatory Alignment | Supports GLP/GMP workflows and FDA 21 CFR Part 11–compliant data integrity requirements |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | TSSR |
| Application | Isothermal and Non-isothermal Stress Relaxation Testing (TSSR/AISR Method) |
| Compliance Context | ASTM D624, ISO 37, ISO 6982, DIN 53515 |
| Software | Automated real-time data acquisition, spectral evaluation, and GLP-compliant storage |
| Measurement Principle | Torque-based viscoelastic stress decay under constrained strain in rotational rheometric configuration |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | AbsorptoMeter |
| Standards Compliance | ASTM D2414, ASTM D3493, ASTM D6854 |
| Measurement Principle | Automated Titration-Based Oil Absorption (OAN) |
| Construction | Stainless Steel Housing |
| Software | Integrated PC-Based Control with Audit Trail & Data Export |
| Sample Handling | Dedicated Mixing Discs for Carbon Black & Silica |
| Viscosity Range | Up to 1,000,000 mPa·s |
| Solvent Compatibility | NMP, Paraffin Oil, and Other Standard Oils |
| Automation Level | Fully Automated Titration, Dosing, Mixing, Endpoint Detection |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | ExtensoGraph |
| Compliance | ICC Standard No. 110, AACC Method 54-10, ISO 27971 |
| Temperature Control Range | 20–40 °C (±0.2 °C) |
| Humidity Control Range | 30–95% RH (±2% RH) |
| Measurement Resolution | 0.1 mm (extension), 0.01 N (force) |
| Sample Capacity | Up to 2 × 300 g dough pieces per test cycle |
| Data Export Formats | CSV, XML, PDF |
| Software Platform | MetaBridge v3.2 (FDA 21 CFR Part 11 compliant with audit trail, electronic signatures, and user role management) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TwinLab Tobacco |
| Pricing | Upon Request |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar TorqueTec GmbH (formerly Brabender GmbH) |
| Model | SM 4 |
| Grinding Principle | Adjustable-gap roller mill with dual counter-rotating corrugated rollers |
| Max. Feed Capacity | 200 g per batch |
| Adjustable Gap Range | 0.1–3.0 mm (micrometer-adjustable) |
| Motor Power | 0.75 kW |
| Speed | 250 rpm (fixed) |
| Construction | Stainless steel housing, food-grade contact materials |
| Compliance | ISO 6540, ISO 712, ISO 20483, AOAC 991.20, AACC 22–10 |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Amylograph-E |
| Compliance | ICC Standard 110/1, ISO 7973, AACCI Method 22-05 |
| Temperature Ramp | 30–95 °C at 1.5 °C/min |
| Torque Measurement Range | 0–1000 mNm |
| Resolution | 0.1 mNm |
| Sample Volume | 50 g flour + 50 mL water (standard) |
| Real-time Sample Temperature Monitoring | Yes, direct-contact Pt100 sensor |
| Data Output | BU (Brabender Units) / AU (Amylograph Units) |
| Software Integration | MetaBridge Standalone v3.0+ |
| Regulatory Alignment | Supports GLP-compliant audit trails, 21 CFR Part 11–ready configuration options |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model Series | Quadrumat Junior / Quadrumat Senior |
| Application | Laboratory-scale milling of wheat, durum, rye, barley and other cereals for flour quality analysis |
| Compliance | Designed in accordance with ISO 27971 (Cereal and cereal products — Determination of milling yield), ISO 5528 (Cereals — Sampling), and aligned with AACC International Method 26–10A (Milling of Wheat to Produce Flour for Baking Tests) |
| Key Features | Dual-roller (Junior) and quad-roller (Senior) configuration |
| Standard Sieve Aperture | 280 µm |
| Max. Feed Moisture Content | 18% w/w |
| Cleaning | Tool-free circular sieve removal |
| Optional Integration | Compatible with Brabender Debranning Unit (TorqueTec GmbH) for ash reduction and yield optimization |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | MT-CA |
| Measurement Principle | Thermogravimetric (Heated Chamber Drying) |
| Moisture Range | 0.1% to 99.9% |
| Sample Capacity | Up to 10 positions |
| Compliance | ICC Standard 114, ISO 712, EC Tobacco Directive 2001/32/EC, USP <921>, ASTM D4457 |
| Software | MetaBridge v3.x (Web-based, Browser-Accessible) |
| Data Integrity | Audit Trail, User Access Levels, Electronic Signatures (21 CFR Part 11 Ready) |
| Footprint | Compact Benchtop Design |
| Interface | Integrated Touchscreen PC, Ethernet/Wi-Fi Connectivity |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar TorqueTec GmbH (formerly Brabender) |
| Model | ViscoQuick |
| Heating Rate | +20 °C/min |
| Cooling Rate | −15 °C/min |
| Operating Temperature Range | ≤20 °C to ≥95 °C |
| Measurement Principle | Rotational Viscometry (Torque-based) |
| Data Interface | Web-based MetaBridge Software |
| Compliance Support | ASTM D445, ISO 3104, ISO 2555, USP <911>, GLP/GMP-ready audit trail |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Viscograph-E |
| Sample Mass | 40 g |
| Compliance | ICC Standard No. 162, AACCI Method 76-15A |
| Temperature Control Accuracy | ±0.1 °C |
| Probe Type | Direct-contact immersion Pt100 sensor |
| Construction | Stainless steel bowl and stirrer |
| Software Platform | MetaBridge v3.x (supports FDA 21 CFR Part 11 audit trail, LIMS integration, multi-instrument synchronization) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | FarinoGraph |
| Weight (without S300 mixer) | 56 kg |
| Weight (with S300 mixer) | 74 kg |
| Dimensions (W × H × D) | 430 mm × 630 mm × 740 mm |
| Torque | 28 N·m |
| Speed Range | 0–200 rpm |
| Power Supply | 230 V (184–264 V) + N + PE / 50–60 Hz / 4.3 A / 1 kW or 115 V (88–126 V) + PE / 50–60 Hz / 8.7 A / 1 kW |
| Interfaces | 4 × USB, 1 × HDMI, 2 × LAN |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | RapidOxy 100 |
| Pricing | Available upon Request |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | TwinLab Rubber |
| Screw Diameter | 12 / 20 / 30 mm |
| L/D Ratio | 36 / 40 |
| Torque Capacity | 14 / 30 / 60 / 150 N·m |
| Operating Temperature | >500 °C |
| Throughput Range | 0.05–100 kg/h |
| Drive System | MetaStation Modular Drive Platform |
| Software | MetaBridge (Cross-Platform, Cloud-Ready, Audit-Trail Capable) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer Entity | Authorized Distributor |
| Origin Category | Imported |
| Model | GlutoPeak |
| Pricing | Available Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH (Petrotest GmbH, a company of Anton Paar) |
| Product Category | Imported |
| Model | BPA |
| Price | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | PNR 12 |
| Pricing | Upon Request |