Empowering Scientific Discovery

Anton Paar (Shanghai) Trading Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
ManufacturerAnton Paar GmbH (Petrotest Division)
TypeImported Instrument
ModelPetroOxy
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
Manufacturer TypeManufacturer
Product CategoryImported Instrument
ModelPMA 500
Detection MethodClosed Cup Method
Operation ModeFully Automatic
Temperature RangeAmbient + X °C to 410 °C
Ignition MethodElectric Spark Ignition
Compliant StandardsASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelCallisto 100
Temperature Range–60 °C to +45 °C
Cooling ProfileProgrammable stepwise or linear (6–100 °C/h)
CalibrationAutomated calibration for sample/jacket temperature and vacuum
Temperature Accuracy±0.1 °C
Data Storage1000 test results
User ProgramsUp to 90 customizable methods
External Cooling RequiredYes (280 W at –20 °C)
Dimensions340 × 580 × 310 mm (W × D × H)
Weight14 kg
Power Supply100–240 V, 50/60 Hz, 290 VA
Interfaces4× USB, 1× RS232, 1× LAN, 1× VGA
Data ExportXLS, PDF via USB flash drive
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelDiana 700
Test PressureAtmospheric (101.3 kPa)
Temperature Range0–450 °C
Temperature Accuracy±0.1 °C
Cooling Bath Range0–80 °C
Distillation Rate2–12 mL/min
Volume Detection Range0–103.5 mL
Volume Resolution0.01 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
ManufacturerAnton Paar GmbH
Product TypeImported Instrument
ModelPMA 300
Test MethodClosed-Cup (Pensky-Martens)
Operation ModeFully Automatic
Temperature RangeAmbient + ~10 °C to 370 °C
Ignition SourceElectronic (Encapsulated Hot-Wire)
Compliant StandardsASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelAlex 301 / Alex 501
Instrument TypeBrewery-Specific Analyzer
ApplicationLaboratory Use
Alcohol RangeBeer 0.5–15 % v/v
Density Measurement Range0.9500–1.200 g/cm³
Accuracy (Alcohol)±0.25 % v/v (Alex 301), ±0.2 % v/v (Alex 501)
Repeatability (Alcohol)0.15 % v/v (Alex 301), 0.1 % v/v (Alex 501)
Density Accuracy±0.001 g/cm³
Density Repeatability (Std. Dev.)0.0007 g/cm³ (Alex 301), 0.0005 g/cm³ (Alex 501)
Density Resolution0.0001 g/cm³
Sample Volume40 mL
Dimensions (L × W × H)320 mm × 230 mm × 100 mm
Weight~2.4 kg
Operating Temperature10–32 °C
Sample Temperature Range15–25 °C (Alex 301), 10–30 °C (Alex 501)
Interfaces1× Bluetooth®, 1× RS-232 (9-pin D-sub), 1× USB-B
Power Supply100–240 V~, 50/60 Hz, ±10%, DC 15 V / 2.6 A
Power Consumption20 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelALAB 5000
Instrument TypeIntegrated Online Beverage Quality Analyzer & Cap Torque Tester
Application ModeIn-line / At-line
Measurement Time (Analytic)8 min per sample
Measurement Time (Torque)30 s per sample
Alcohol Content Range0–12 % v/v
pH Range0–14
Dimensions (L × W × H)1750 mm × 880 mm × 2430 mm
Weight900 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelABA 300 & ABA 500
Detection MethodClosed-Cup (Abel)
Operation ModeFully Automatic
Temperature Range10 °C to 110 °C (air-cooled)
Ignition SourceElectronic (encapsulated hot-wire)
Repeatability±1.4 °C
Compliant StandardsISO 13736, ISO 1516, ISO 1523, GB/T 21789, GB/T 21775, GB/T 21792
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelABA 500
Detection MethodClosed Cup
Operation ModeAutomatic
Temperature Range−35 °C to +130 °C
Ignition MethodElectronic (Encapsulated Hot Wire)
Applicable StandardsISO 13736, ISO 1516, ISO 1523, GB/T 21789
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
ManufacturerAnton Paar GmbH
TypeImported Instrument
ModelRapidOxy
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelCLA 5
Detection MethodCleveland Open Cup (COC)
Operation ModeFully Automated
Temperature RangeUp to 400 °C (°C/°F selectable)
Ignition SourcePressurized Propane or Butane Gas
Compliant StandardsASTM D92, ISO 2592, IP 36, DIN 51376, JIS K 2265
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
ManufacturerAnton Paar (Petrotest GmbH, a company of Anton Paar)
ModelGUM
Operating Temperature RangeAmbient to 246 °C (air only)
Sample Positions5 simultaneous
Air Supply2–4 bar, oil-free and filtered
Steam SupplyInlet temperature ≈140 °C, pressure 3–4 bar, controlled flow rate
Power Requirements230 V, 50/60 Hz, 2000 W (air mode)
Dimensions (W × D × H)400 × 400 × 720 mm
Weight44 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelTAG500
Detection MethodClosed-Cup (Tagliabue)
Operation ModeFully Automatic
Temperature Range−30 °C to +130 °C
Ignition SourceElectronic (Encapsulated Hot-Wire)
Compliant StandardsASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelPackaged Beer Measurement System
Instrument TypeDedicated Beer Analyzer
ApplicationLaboratory-Based Quality Control
Measurement Time3 min per sample
Alcohol Content Range0–12 % v/v
pH Range0–14
Dimensions (L × W × H)515 × 1200 × 1120 mm / 482 × 750 × 670 mm / 482 × 730 × 446 mm
Weight30 kg
Sampling TechnologyPressurized Direct Injection, No Sample Preparation Required
Sample Volume per Package260 mL
Throughput7 samples/hour or 15 samples/hour (depending on configuration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelTPO 5000
Instrument TypeBeer-Specific Analyzer
Application ModeOnline & Laboratory
Measurement Time4 min
Dimensions (L × W × H)515 × 590 × 1120 mm
Weight70 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model SeriesCarboQC, CboxQC, OxyQC (At-line Configuration)
Measurement Time2–3 min per sample
Dimensions (L × W × H)258 mm × 201 mm × 170 mm
Weight2.6 kg
Data Storage CapacityUp to 500 measurement datasets
Sample Volume150 mL
CO₂ Range0–12 g/L (0–6 vol%) at 30 °C
Dissolved O₂ Range0–4 ppm
Temperature Range−3 °C to 30 °C
Pressure Range0–10 bar
CO₂ Repeatability (s.d.)±0.005 vol%
O₂ Repeatability (s.d.)±2 ppb
O₂ Response Time (t₉₈%)20 s at 25 °C
Pressure Accuracy±0.01 bar
CO₂ Accuracy (s.d.)±0.05 vol%
O₂ Accuracy (s.d.)±4 ppb
Power SupplyAC 100–240 V, 50/60 Hz
Interfaces1 × USB (PC), 1 × RS-232 (printer or AP-SoftPrint)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
ManufacturerAnton Paar GmbH
TypeImported Instrument
ModelTAG 300/500
Detection MethodClosed-Cup (TAG)
Operation ModeFully Automatic
Sample Temperature Range−35 °C to +130 °C
Ignition SourceCeramic-Coated Electric Igniter
Compliant StandardsASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelAlcolyzer Beer Analyzing System
Instrument TypeBeer-Specific Analyzer
Application TypeLaboratory
Measurement Time3 min
Alcohol Content0–12 % v/v
pH Range0–14
Dimensions (L × W × H)495 × 330 × 230 mm
Weight30 kg
TechnologyInfrared
Sample Volume per Test35 mL
Throughput15–20 samples/hour
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelBetalyser
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ManufacturerAnton Paar TorqueTec GmbH (formerly Brabender GmbH)
ModelTwinLab Series
Configuration OptionsTwin-screw extruder, single-screw extruder (e.g., 19/25 mm), batch mixer
Throughput Range0.05–100 kg/h
Drive SystemMetaStation modular drive unit
Control SoftwareMetaBridge v3.x
Barrel DesignSplit-barrel with quick-release liner
Material Contact PartsWear- and corrosion-resistant high-alloy steel (up to 500 °C service temperature)
ComplianceDesigned for GLP/GMP-aligned R&D environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelAquatrac-V
Measurement PrincipleCalcium Hydride Reaction under Vacuum
ComplianceDIN EN ISO 15512:2019
Resolution0.0001% H₂O (w/w)
Application ScopePolymer Residual Moisture Analysis & MFR Sample Conditioning
SoftwareAquatrac Control Software with Audit Trail, LIMS/ERP Integration Capability
Regulatory AlignmentSupports GLP/GMP workflows and FDA 21 CFR Part 11–compliant data integrity requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelTSSR
ApplicationIsothermal and Non-isothermal Stress Relaxation Testing (TSSR/AISR Method)
Compliance ContextASTM D624, ISO 37, ISO 6982, DIN 53515
SoftwareAutomated real-time data acquisition, spectral evaluation, and GLP-compliant storage
Measurement PrincipleTorque-based viscoelastic stress decay under constrained strain in rotational rheometric configuration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelAbsorptoMeter
Standards ComplianceASTM D2414, ASTM D3493, ASTM D6854
Measurement PrincipleAutomated Titration-Based Oil Absorption (OAN)
ConstructionStainless Steel Housing
SoftwareIntegrated PC-Based Control with Audit Trail & Data Export
Sample HandlingDedicated Mixing Discs for Carbon Black & Silica
Viscosity RangeUp to 1,000,000 mPa·s
Solvent CompatibilityNMP, Paraffin Oil, and Other Standard Oils
Automation LevelFully Automated Titration, Dosing, Mixing, Endpoint Detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelExtensoGraph
ComplianceICC Standard No. 110, AACC Method 54-10, ISO 27971
Temperature Control Range20–40 °C (±0.2 °C)
Humidity Control Range30–95% RH (±2% RH)
Measurement Resolution0.1 mm (extension), 0.01 N (force)
Sample CapacityUp to 2 × 300 g dough pieces per test cycle
Data Export FormatsCSV, XML, PDF
Software PlatformMetaBridge v3.2 (FDA 21 CFR Part 11 compliant with audit trail, electronic signatures, and user role management)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0