- All
- Favorite
- Popular
- Most rated
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH (Petrotest Division) |
| Type | Imported Instrument |
| Model | PetroOxy |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | PMA 500 |
| Detection Method | Closed Cup Method |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient + X °C to 410 °C |
| Ignition Method | Electric Spark Ignition |
| Compliant Standards | ASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Callisto 100 |
| Temperature Range | –60 °C to +45 °C |
| Cooling Profile | Programmable stepwise or linear (6–100 °C/h) |
| Calibration | Automated calibration for sample/jacket temperature and vacuum |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 1000 test results |
| User Programs | Up to 90 customizable methods |
| External Cooling Required | Yes (280 W at –20 °C) |
| Dimensions | 340 × 580 × 310 mm (W × D × H) |
| Weight | 14 kg |
| Power Supply | 100–240 V, 50/60 Hz, 290 VA |
| Interfaces | 4× USB, 1× RS232, 1× LAN, 1× VGA |
| Data Export | XLS, PDF via USB flash drive |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Diana 700 |
| Test Pressure | Atmospheric (101.3 kPa) |
| Temperature Range | 0–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling Bath Range | 0–80 °C |
| Distillation Rate | 2–12 mL/min |
| Volume Detection Range | 0–103.5 mL |
| Volume Resolution | 0.01 mL |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | PMA 300 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient + ~10 °C to 370 °C |
| Ignition Source | Electronic (Encapsulated Hot-Wire) |
| Compliant Standards | ASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Alex 301 / Alex 501 |
| Instrument Type | Brewery-Specific Analyzer |
| Application | Laboratory Use |
| Alcohol Range | Beer 0.5–15 % v/v |
| Density Measurement Range | 0.9500–1.200 g/cm³ |
| Accuracy (Alcohol) | ±0.25 % v/v (Alex 301), ±0.2 % v/v (Alex 501) |
| Repeatability (Alcohol) | 0.15 % v/v (Alex 301), 0.1 % v/v (Alex 501) |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability (Std. Dev.) | 0.0007 g/cm³ (Alex 301), 0.0005 g/cm³ (Alex 501) |
| Density Resolution | 0.0001 g/cm³ |
| Sample Volume | 40 mL |
| Dimensions (L × W × H) | 320 mm × 230 mm × 100 mm |
| Weight | ~2.4 kg |
| Operating Temperature | 10–32 °C |
| Sample Temperature Range | 15–25 °C (Alex 301), 10–30 °C (Alex 501) |
| Interfaces | 1× Bluetooth®, 1× RS-232 (9-pin D-sub), 1× USB-B |
| Power Supply | 100–240 V~, 50/60 Hz, ±10%, DC 15 V / 2.6 A |
| Power Consumption | 20 W |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ALAB 5000 |
| Instrument Type | Integrated Online Beverage Quality Analyzer & Cap Torque Tester |
| Application Mode | In-line / At-line |
| Measurement Time (Analytic) | 8 min per sample |
| Measurement Time (Torque) | 30 s per sample |
| Alcohol Content Range | 0–12 % v/v |
| pH Range | 0–14 |
| Dimensions (L × W × H) | 1750 mm × 880 mm × 2430 mm |
| Weight | 900 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ABA 300 & ABA 500 |
| Detection Method | Closed-Cup (Abel) |
| Operation Mode | Fully Automatic |
| Temperature Range | 10 °C to 110 °C (air-cooled) |
| Ignition Source | Electronic (encapsulated hot-wire) |
| Repeatability | ±1.4 °C |
| Compliant Standards | ISO 13736, ISO 1516, ISO 1523, GB/T 21789, GB/T 21775, GB/T 21792 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ABA 500 |
| Detection Method | Closed Cup |
| Operation Mode | Automatic |
| Temperature Range | −35 °C to +130 °C |
| Ignition Method | Electronic (Encapsulated Hot Wire) |
| Applicable Standards | ISO 13736, ISO 1516, ISO 1523, GB/T 21789 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | RapidOxy |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CLA 5 |
| Detection Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automated |
| Temperature Range | Up to 400 °C (°C/°F selectable) |
| Ignition Source | Pressurized Propane or Butane Gas |
| Compliant Standards | ASTM D92, ISO 2592, IP 36, DIN 51376, JIS K 2265 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar (Petrotest GmbH, a company of Anton Paar) |
| Model | GUM |
| Operating Temperature Range | Ambient to 246 °C (air only) |
| Sample Positions | 5 simultaneous |
| Air Supply | 2–4 bar, oil-free and filtered |
| Steam Supply | Inlet temperature ≈140 °C, pressure 3–4 bar, controlled flow rate |
| Power Requirements | 230 V, 50/60 Hz, 2000 W (air mode) |
| Dimensions (W × D × H) | 400 × 400 × 720 mm |
| Weight | 44 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | TAG500 |
| Detection Method | Closed-Cup (Tagliabue) |
| Operation Mode | Fully Automatic |
| Temperature Range | −30 °C to +130 °C |
| Ignition Source | Electronic (Encapsulated Hot-Wire) |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Packaged Beer Measurement System |
| Instrument Type | Dedicated Beer Analyzer |
| Application | Laboratory-Based Quality Control |
| Measurement Time | 3 min per sample |
| Alcohol Content Range | 0–12 % v/v |
| pH Range | 0–14 |
| Dimensions (L × W × H) | 515 × 1200 × 1120 mm / 482 × 750 × 670 mm / 482 × 730 × 446 mm |
| Weight | 30 kg |
| Sampling Technology | Pressurized Direct Injection, No Sample Preparation Required |
| Sample Volume per Package | 260 mL |
| Throughput | 7 samples/hour or 15 samples/hour (depending on configuration) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TPO 5000 |
| Instrument Type | Beer-Specific Analyzer |
| Application Mode | Online & Laboratory |
| Measurement Time | 4 min |
| Dimensions (L × W × H) | 515 × 590 × 1120 mm |
| Weight | 70 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model Series | CarboQC, CboxQC, OxyQC (At-line Configuration) |
| Measurement Time | 2–3 min per sample |
| Dimensions (L × W × H) | 258 mm × 201 mm × 170 mm |
| Weight | 2.6 kg |
| Data Storage Capacity | Up to 500 measurement datasets |
| Sample Volume | 150 mL |
| CO₂ Range | 0–12 g/L (0–6 vol%) at 30 °C |
| Dissolved O₂ Range | 0–4 ppm |
| Temperature Range | −3 °C to 30 °C |
| Pressure Range | 0–10 bar |
| CO₂ Repeatability (s.d.) | ±0.005 vol% |
| O₂ Repeatability (s.d.) | ±2 ppb |
| O₂ Response Time (t₉₈%) | 20 s at 25 °C |
| Pressure Accuracy | ±0.01 bar |
| CO₂ Accuracy (s.d.) | ±0.05 vol% |
| O₂ Accuracy (s.d.) | ±4 ppb |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Interfaces | 1 × USB (PC), 1 × RS-232 (printer or AP-SoftPrint) |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | TAG 300/500 |
| Detection Method | Closed-Cup (TAG) |
| Operation Mode | Fully Automatic |
| Sample Temperature Range | −35 °C to +130 °C |
| Ignition Source | Ceramic-Coated Electric Igniter |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Alcolyzer Beer Analyzing System |
| Instrument Type | Beer-Specific Analyzer |
| Application Type | Laboratory |
| Measurement Time | 3 min |
| Alcohol Content | 0–12 % v/v |
| pH Range | 0–14 |
| Dimensions (L × W × H) | 495 × 330 × 230 mm |
| Weight | 30 kg |
| Technology | Infrared |
| Sample Volume per Test | 35 mL |
| Throughput | 15–20 samples/hour |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Betalyser |
| Price | Upon Request |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar TorqueTec GmbH (formerly Brabender GmbH) |
| Model | TwinLab Series |
| Configuration Options | Twin-screw extruder, single-screw extruder (e.g., 19/25 mm), batch mixer |
| Throughput Range | 0.05–100 kg/h |
| Drive System | MetaStation modular drive unit |
| Control Software | MetaBridge v3.x |
| Barrel Design | Split-barrel with quick-release liner |
| Material Contact Parts | Wear- and corrosion-resistant high-alloy steel (up to 500 °C service temperature) |
| Compliance | Designed for GLP/GMP-aligned R&D environments |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Aquatrac-V |
| Measurement Principle | Calcium Hydride Reaction under Vacuum |
| Compliance | DIN EN ISO 15512:2019 |
| Resolution | 0.0001% H₂O (w/w) |
| Application Scope | Polymer Residual Moisture Analysis & MFR Sample Conditioning |
| Software | Aquatrac Control Software with Audit Trail, LIMS/ERP Integration Capability |
| Regulatory Alignment | Supports GLP/GMP workflows and FDA 21 CFR Part 11–compliant data integrity requirements |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | TSSR |
| Application | Isothermal and Non-isothermal Stress Relaxation Testing (TSSR/AISR Method) |
| Compliance Context | ASTM D624, ISO 37, ISO 6982, DIN 53515 |
| Software | Automated real-time data acquisition, spectral evaluation, and GLP-compliant storage |
| Measurement Principle | Torque-based viscoelastic stress decay under constrained strain in rotational rheometric configuration |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | AbsorptoMeter |
| Standards Compliance | ASTM D2414, ASTM D3493, ASTM D6854 |
| Measurement Principle | Automated Titration-Based Oil Absorption (OAN) |
| Construction | Stainless Steel Housing |
| Software | Integrated PC-Based Control with Audit Trail & Data Export |
| Sample Handling | Dedicated Mixing Discs for Carbon Black & Silica |
| Viscosity Range | Up to 1,000,000 mPa·s |
| Solvent Compatibility | NMP, Paraffin Oil, and Other Standard Oils |
| Automation Level | Fully Automated Titration, Dosing, Mixing, Endpoint Detection |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | ExtensoGraph |
| Compliance | ICC Standard No. 110, AACC Method 54-10, ISO 27971 |
| Temperature Control Range | 20–40 °C (±0.2 °C) |
| Humidity Control Range | 30–95% RH (±2% RH) |
| Measurement Resolution | 0.1 mm (extension), 0.01 N (force) |
| Sample Capacity | Up to 2 × 300 g dough pieces per test cycle |
| Data Export Formats | CSV, XML, PDF |
| Software Platform | MetaBridge v3.2 (FDA 21 CFR Part 11 compliant with audit trail, electronic signatures, and user role management) |
Show next