BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelTPO 5000
Instrument TypeBeer-Specific Analyzer
Application ModeOnline & Laboratory
Measurement Time4 min
Dimensions (L × W × H)515 × 590 × 1120 mm
Weight70 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model SeriesCarboQC, CboxQC, OxyQC (At-line Configuration)
Measurement Time2–3 min per sample
Dimensions (L × W × H)258 mm × 201 mm × 170 mm
Weight2.6 kg
Data Storage CapacityUp to 500 measurement datasets
Sample Volume150 mL
CO₂ Range0–12 g/L (0–6 vol%) at 30 °C
Dissolved O₂ Range0–4 ppm
Temperature Range−3 °C to 30 °C
Pressure Range0–10 bar
CO₂ Repeatability (s.d.)±0.005 vol%
O₂ Repeatability (s.d.)±2 ppb
O₂ Response Time (t₉₈%)20 s at 25 °C
Pressure Accuracy±0.01 bar
CO₂ Accuracy (s.d.)±0.05 vol%
O₂ Accuracy (s.d.)±4 ppb
Power SupplyAC 100–240 V, 50/60 Hz
Interfaces1 × USB (PC), 1 × RS-232 (printer or AP-SoftPrint)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
ManufacturerAnton Paar GmbH
TypeImported Instrument
ModelTAG 300/500
Detection MethodClosed-Cup (TAG)
Operation ModeFully Automatic
Sample Temperature Range−35 °C to +130 °C
Ignition SourceCeramic-Coated Electric Igniter
Compliant StandardsASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelAlcolyzer Beer Analyzing System
Instrument TypeBeer-Specific Analyzer
Application TypeLaboratory
Measurement Time3 min
Alcohol Content0–12 % v/v
pH Range0–14
Dimensions (L × W × H)495 × 330 × 230 mm
Weight30 kg
TechnologyInfrared
Sample Volume per Test35 mL
Throughput15–20 samples/hour
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelBetalyser
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ManufacturerAnton Paar TorqueTec GmbH (formerly Brabender GmbH)
ModelTwinLab Series
Configuration OptionsTwin-screw extruder, single-screw extruder (e.g., 19/25 mm), batch mixer
Throughput Range0.05–100 kg/h
Drive SystemMetaStation modular drive unit
Control SoftwareMetaBridge v3.x
Barrel DesignSplit-barrel with quick-release liner
Material Contact PartsWear- and corrosion-resistant high-alloy steel (up to 500 °C service temperature)
ComplianceDesigned for GLP/GMP-aligned R&D environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelAquatrac-V
Measurement PrincipleCalcium Hydride Reaction under Vacuum
ComplianceDIN EN ISO 15512:2019
Resolution0.0001% H₂O (w/w)
Application ScopePolymer Residual Moisture Analysis & MFR Sample Conditioning
SoftwareAquatrac Control Software with Audit Trail, LIMS/ERP Integration Capability
Regulatory AlignmentSupports GLP/GMP workflows and FDA 21 CFR Part 11–compliant data integrity requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelTSSR
ApplicationIsothermal and Non-isothermal Stress Relaxation Testing (TSSR/AISR Method)
Compliance ContextASTM D624, ISO 37, ISO 6982, DIN 53515
SoftwareAutomated real-time data acquisition, spectral evaluation, and GLP-compliant storage
Measurement PrincipleTorque-based viscoelastic stress decay under constrained strain in rotational rheometric configuration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelAbsorptoMeter
Standards ComplianceASTM D2414, ASTM D3493, ASTM D6854
Measurement PrincipleAutomated Titration-Based Oil Absorption (OAN)
ConstructionStainless Steel Housing
SoftwareIntegrated PC-Based Control with Audit Trail & Data Export
Sample HandlingDedicated Mixing Discs for Carbon Black & Silica
Viscosity RangeUp to 1,000,000 mPa·s
Solvent CompatibilityNMP, Paraffin Oil, and Other Standard Oils
Automation LevelFully Automated Titration, Dosing, Mixing, Endpoint Detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelExtensoGraph
ComplianceICC Standard No. 110, AACC Method 54-10, ISO 27971
Temperature Control Range20–40 °C (±0.2 °C)
Humidity Control Range30–95% RH (±2% RH)
Measurement Resolution0.1 mm (extension), 0.01 N (force)
Sample CapacityUp to 2 × 300 g dough pieces per test cycle
Data Export FormatsCSV, XML, PDF
Software PlatformMetaBridge v3.2 (FDA 21 CFR Part 11 compliant with audit trail, electronic signatures, and user role management)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTwinLab Tobacco
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ManufacturerAnton Paar TorqueTec GmbH (formerly Brabender GmbH)
ModelSM 4
Grinding PrincipleAdjustable-gap roller mill with dual counter-rotating corrugated rollers
Max. Feed Capacity200 g per batch
Adjustable Gap Range0.1–3.0 mm (micrometer-adjustable)
Motor Power0.75 kW
Speed250 rpm (fixed)
ConstructionStainless steel housing, food-grade contact materials
ComplianceISO 6540, ISO 712, ISO 20483, AOAC 991.20, AACC 22–10
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelAmylograph-E
ComplianceICC Standard 110/1, ISO 7973, AACCI Method 22-05
Temperature Ramp30–95 °C at 1.5 °C/min
Torque Measurement Range0–1000 mNm
Resolution0.1 mNm
Sample Volume50 g flour + 50 mL water (standard)
Real-time Sample Temperature MonitoringYes, direct-contact Pt100 sensor
Data OutputBU (Brabender Units) / AU (Amylograph Units)
Software IntegrationMetaBridge Standalone v3.0+
Regulatory AlignmentSupports GLP-compliant audit trails, 21 CFR Part 11–ready configuration options
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
Model SeriesQuadrumat Junior / Quadrumat Senior
ApplicationLaboratory-scale milling of wheat, durum, rye, barley and other cereals for flour quality analysis
ComplianceDesigned in accordance with ISO 27971 (Cereal and cereal products — Determination of milling yield), ISO 5528 (Cereals — Sampling), and aligned with AACC International Method 26–10A (Milling of Wheat to Produce Flour for Baking Tests)
Key FeaturesDual-roller (Junior) and quad-roller (Senior) configuration
Standard Sieve Aperture280 µm
Max. Feed Moisture Content18% w/w
CleaningTool-free circular sieve removal
Optional IntegrationCompatible with Brabender Debranning Unit (TorqueTec GmbH) for ash reduction and yield optimization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelMT-CA
Measurement PrincipleThermogravimetric (Heated Chamber Drying)
Moisture Range0.1% to 99.9%
Sample CapacityUp to 10 positions
ComplianceICC Standard 114, ISO 712, EC Tobacco Directive 2001/32/EC, USP <921>, ASTM D4457
SoftwareMetaBridge v3.x (Web-based, Browser-Accessible)
Data IntegrityAudit Trail, User Access Levels, Electronic Signatures (21 CFR Part 11 Ready)
FootprintCompact Benchtop Design
InterfaceIntegrated Touchscreen PC, Ethernet/Wi-Fi Connectivity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ManufacturerAnton Paar TorqueTec GmbH (formerly Brabender)
ModelViscoQuick
Heating Rate+20 °C/min
Cooling Rate−15 °C/min
Operating Temperature Range≤20 °C to ≥95 °C
Measurement PrincipleRotational Viscometry (Torque-based)
Data InterfaceWeb-based MetaBridge Software
Compliance SupportASTM D445, ISO 3104, ISO 2555, USP <911>, GLP/GMP-ready audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelViscograph-E
Sample Mass40 g
ComplianceICC Standard No. 162, AACCI Method 76-15A
Temperature Control Accuracy±0.1 °C
Probe TypeDirect-contact immersion Pt100 sensor
ConstructionStainless steel bowl and stirrer
Software PlatformMetaBridge v3.x (supports FDA 21 CFR Part 11 audit trail, LIMS integration, multi-instrument synchronization)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelFarinoGraph
Weight (without S300 mixer)56 kg
Weight (with S300 mixer)74 kg
Dimensions (W × H × D)430 mm × 630 mm × 740 mm
Torque28 N·m
Speed Range0–200 rpm
Power Supply230 V (184–264 V) + N + PE / 50–60 Hz / 4.3 A / 1 kW or 115 V (88–126 V) + PE / 50–60 Hz / 8.7 A / 1 kW
Interfaces4 × USB, 1 × HDMI, 2 × LAN
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelRapidOxy 100
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelTwinLab Rubber
Screw Diameter12 / 20 / 30 mm
L/D Ratio36 / 40
Torque Capacity14 / 30 / 60 / 150 N·m
Operating Temperature>500 °C
Throughput Range0.05–100 kg/h
Drive SystemMetaStation Modular Drive Platform
SoftwareMetaBridge (Cross-Platform, Cloud-Ready, Audit-Trail Capable)
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
Manufacturer EntityAuthorized Distributor
Origin CategoryImported
ModelGlutoPeak
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
ManufacturerAnton Paar GmbH (Petrotest GmbH, a company of Anton Paar)
Product CategoryImported
ModelBPA
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
ManufacturerAnton Paar GmbH
Product TypeImported Instrument
ModelPNR 12
PricingUpon Request