| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DMA 1002/1102 Petro |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Category | Portable |
| Sample Type | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Range | 15 °C to 100 °C (59 °F to 212 °F) |
| Temperature Accuracy | ±0.03 °C (from +15 °C to +100 °C) |
| Density Resolution | 5 significant digits |
| Viscosity Range (DMA 1102 only) | –0.3 mm²/s to 1000 mm²/s |
| Viscosity Repeatability | ±0.2% |
| Minimum Sample Volume | 3.5 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP touch screen |
| Dimensions (L×W×H) | 365 mm × 265 mm × 180 mm |
| Weight | 6.6 kg |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Ultrapyc Series |
| Instrument Type | True Density Analyzer |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Solids (bulk & granular), Powders, Pastes, Slurries, Foams |
| Density Accuracy | ≤0.015% |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Temperature Range | 3–60 °C |
| Minimum Sample Volume | 0.1 cm³ |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 502 |
| Instrument Type | Oscillating U-tube Density Meter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids and Low-Viscosity Suspensions |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability | ±0.0002 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | 15–40 °C |
| Temperature Stability | ±0.1 °C |
| Minimum Sample Volume | 1 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Environmental Compensation | Automatic pressure, altitude, and ambient humidity correction |
| Data Storage | 5000 measurements |
| Method Library | 400 pre-validated methods |
| Conversion Tables | 140 built-in (alcohol, sugar, acids, API gravity, etc.) |
| Compliance | ASTM D4052, ASTM D5002, USP <841>, EP/JP pharmacopoeial density requirements, FDA 21 CFR Part 11 (when used with AP Connect) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Perfume and Flavor Measurement System |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Display | 10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen |
| Temperature Control Range | 0–100 °C |
| Minimum Sample Volume | 2 mL |
| Integrated Parameters | Density, Refractive Index, Optical Rotation, Colorimetry, Turbidity |
| Automation | Fully Automated Sample Handling with Recovery (Xsample 5200/530), Integrated Cleaning & Drying |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 1102 Petro |
| Instrument Type | Oscillating U-tube Densimeter |
| Application | Petroleum Products Density & Kinematic Viscosity Measurement |
| Detection Medium | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Resolution | 5 significant digits |
| Temperature Range | 15 °C to 100 °C (59 °F to 212 °F) |
| Temperature Stability | ±0.03 °C over full range |
| Viscosity Range | −0.3 mm²/s to 1000 mm²/s |
| Viscosity Repeatability | ±0.2% |
| Minimum Sample Volume | 3.5 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Dimensions (L×W×H) | 365 × 265 × 180 mm |
| Weight | 6.6 kg |
| Power Supply | DC 24 V / 3 A |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DMA 1002 |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Repeatability | ±0.00005 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Temperature Range | 15–60 °C |
| Temperature Stability | ±0.02 °C |
| Minimum Sample Volume | 1 mL |
| Display | 7″ TFT WVGA Touchscreen (800 × 480 px, PCAP) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DMA 6002 Sound Velocity |
| Instrument Type | Oscillating U-tube Densimeter & Sound Velocity Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Sound Velocity Range | 1000 m/s to 2000 m/s |
| Temperature Range | 0 °C to 100 °C (32 °F to 212 °F) |
| Pressure Range | 0 bar to 8 bar (0 psi to 116 psi) |
| Density Accuracy | ±0.000005 g/cm³ |
| Density Repeatability (Std. Dev.) | ±0.000001 g/cm³ |
| Sound Velocity Repeatability (Std. Dev.) | ±0.1 m/s |
| Density Reproducibility (Std. Dev.) | ±0.000005 g/cm³ |
| Sound Velocity Reproducibility (Std. Dev.) | ±0.5 m/s |
| Density Resolution | 0.000001 g/cm³ |
| Sound Velocity Resolution | 0.01 m/s |
| Minimum Sample Volume | 3.5 mL |
| Measurement Throughput | Up to 30 samples/hour |
| Compliance | ISO 5725, ASTM D4052, ASTM D1250, ISO 12185, ISO 17025 (when operated with certified calibration standards) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 4002 / DMA 5002 / DMA 6002 |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Class | Benchtop Laboratory Densimeter |
| Sample Type | Liquid |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.00005 g/cm³ (DMA 4002), ±0.00001 g/cm³ (DMA 5002, 0–1.05 g/cm³ at 15–20 °C), ±0.000005 g/cm³ (DMA 6002, full range) |
| Temperature Range | 0 °C to 100 °C |
| Temperature Accuracy | ±0.02 °C (DMA 4002), ±0.01 °C (DMA 5002 & DMA 6002, 15–20 °C) |
| Density Repeatability (Std. Dev.) | 0.00001 g/cm³ (DMA 4002), 0.000003 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002) |
| Density Resolution | 0.00001 g/cm³ (DMA 4002), 0.000005 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002) |
| Minimum Sample Volume | 1 mL |
| Display | 10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen |
| Compliance | ASTM D4052, D5002, D1250 |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | ElaTest |
| Density Measurement Range | 0.8–2.6 g/cm³ |
| Temperature Range | 0–40.0 °C |
| Repeatability | ±0.00001 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 40–120 cm³ |
| Application | Density of uncured rubber and rubber compounds |
| Instrument Type | Benchtop Laboratory Densitometer |
| Detection Principle | Pneumatic (gas displacement) density measurement |
| Compliance | Designed for GLP/GMP environments with audit-ready data handling |