Empowering Scientific Discovery

Anton Paar (Shanghai) Trading Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelDMA 4200M
Instrument TypeOscillating U-Tube Densimeter
Form FactorBenchtop Laboratory Instrument
Sample TypeLiquid
Density Range0–3 g/cm³
Density Accuracy±0.0002 g/cm³
Density Repeatability (s.d.)±0.00005 g/cm³
Digital Resolution0.00001 g/cm³
Temperature Range−10 °C to 200 °C (14 °F to 392 °F)
Pressure Range0–500 bar (7250 psi)
Minimum Sample Volume2 mL
Viscosity CorrectionFully Automated, Real-Time
Filling VerificationFillingCheck™
Thermal Equilibration TechnologyTemperfect™
Oscillation Excitation MethodPulsed Excitation Method (Patent AT 516420 B1)
Wetted MaterialsHastelloy C-276
Compliance StandardsASTM D4052, ASTM D5002, GB/T 29617
Power SupplyAC 100–240 V, 50–60 Hz, 250 VA
Interface Ports4× USB 2.0, 1× Ethernet (100 Mbit), 1× CAN Bus, 1× RS-232, 1× VGA, 1× 1/8″ OD metal pressure fitting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginImported
Manufacturer TypeManufacturer
ModelXsample Series
Sample TypeLiquid
Minimum Sample Volume5 mL / 10 mL (when coupled with DMA instruments)
Viscosity Rangeup to 1000 mPa·s
Instrument ClassBenchtop Laboratory
Application ScopeUniversal Density Measurement
ComplianceDesigned for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11–enabled software environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelHPM
Instrument TypeOscillating U-tube Densimeter
Form FactorBenchtop Laboratory Instrument
Sample PhaseLiquid
Density Range0–3 g/cm³
Density Accuracy±0.0001 g/cm³
Density Repeatability≤0.00001 g/cm³ (standard deviation)
Temperature Range−10 to +200 °C
Pressure Range0–1400 bar (0–20,300 psi)
Minimum Sample Volume~2 mL
Cell MaterialHastelloy C-276
Digital Resolution0.00001 g/cm³
Interface1/4″ metal tubing compression fittings
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelUltratap 500
Instrument TypeBulk Density Tester
Instrument ClassBenchtop Laboratory
Sample TypeSolid Powders & Granules
Density Accuracy0.001 g/cm³
Repeatability0.0001 g/cm³
Resolution0.0001 g/cm³
Minimum Sample Volume5 mL
Vibration Frequency Range50–350 taps/min
Tap Amplitude3 mm ± 0.2 mm or 14 mm ± 1 mm
Noise Level65 dB (58 dB with optional noise-reduction cabinet)
Touchscreen7-inch TFT WVGA (800 × 480 px), PCAP
User ManagementPassword-protected
Built-in Methods24 (ASTM, ISO, USP <616> Methods 1–3)
Data Storage1,000 reports / 100 custom methods
Dimensions (H×W×D)228.6 × 263.5 × 361 mm (9 × 10.4 × 14.2 in)
Weight14.5 kg (single station) / 17.6 kg (dual station)
Power Input24 V DC, 2.1 A (51 W) / 2.6 A (63 W)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelDMA 35
Instrument TypeOscillating U-tube Densimeter
Form FactorPortable
Sample StateLiquid
Density Range0 g/cm³ to 3 g/cm³
Density Accuracy±0.001 g/cm³ (for samples with viscosity < 300 mPa·s and density < 2 g/cm³)
Temperature Range0 °C to 40 °C (32 °F to 104 °F)
Repeatability (std. dev.)±0.0005 g/cm³
Resolution0.0001 g/cm³
Minimum Sample Volume2 mL
Environmental RatingIP54
ATEX/IECEx CertificationII 2G Ex ib IIB T4 Gb (DMA 35 Ex & DMA 35 Ex Petrol variants)
ComplianceASTM D7777, IP 559
ConnectivityBluetooth® 4.2, RFID reader (integrated)
Data StorageUp to 1,200 measurements, 250 sample IDs, 30 user-defined methods
Power3 × 1.5 V LR06 AA alkaline batteries
Weight660 g
Dimensions (L×W×H)245 mm × 103 mm × 126 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
ManufacturerAnton Paar GmbH
TypeOscillating U-tube Densimeter
Form FactorBenchtop Laboratory Instrument
Sample TypeLiquids and Semi-solids (with optional kits)
Density Range0 to 3 g/cm³
Density Accuracy0.001 g/cm³ (DMA 502), 0.0001 g/cm³ (DMA 1002)
Density Repeatability0.0002 g/cm³ (DMA 502), 0.00005 g/cm³ (DMA 1002)
Temperature Range5–35 °C (ambient), 15–40 °C (measurement, DMA 502), 15–60 °C (measurement, DMA 1002)
Temperature Resolution0.01 °C
Minimum Sample Volume~1 mL
Display7-inch TFT WVGA (800 × 480 px) PCAP capacitive touchscreen
Dimensions (L×W×H)375 × 280 × 180 mm
Weight13.5 kg
Connectivity1× Ethernet, 3× USB, 1× RS232
Data Storage5000 measurements, 400 user-defined methods, 140 built-in conversion tables
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
ManufacturerAnton Paar GmbH
Product TypePortable Oscillating U-Tube Densimeter
Sample TypeLiquid
Density Range0–3 g/cm³
Density Accuracy±0.001 g/cm³
Density Repeatability±0.0005 g/cm³
Density Resolution0.0001 g/cm³
Temperature Range (Measurement)0–40 °C
Temperature Accuracy±0.2 °C
Temperature Repeatability±0.1 °C
Minimum Sample Volume1–2 mL
Operating Ambient Temperature−10 to +50 °C
IP RatingIP54
Intrinsic Safety CertificationEx II 2 G Ex ib IIC T4 (Ex and Ex Petrol versions)
Data Storage1024 measurements, 30 methods, 250 sample IDs
ConnectivityBluetooth® v4.2, RFID reader (integrated)
Power Supply3 × AA LR06 alkaline batteries (1.5 V)
Weight660 g
Dimensions (L×W×H)245 × 103 × 126 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelDMA 1002/1102 Petro
Instrument TypeOscillating U-tube Densimeter
Instrument CategoryPortable
Sample TypeLiquid
Density Range0 g/cm³ to 3 g/cm³
Density Accuracy±0.0001 g/cm³
Temperature Range15 °C to 100 °C (59 °F to 212 °F)
Temperature Accuracy±0.03 °C (from +15 °C to +100 °C)
Density Resolution5 significant digits
Viscosity Range (DMA 1102 only)–0.3 mm²/s to 1000 mm²/s
Viscosity Repeatability±0.2%
Minimum Sample Volume3.5 mL
Display7-inch TFT WVGA (800 × 480 px) PCAP touch screen
Dimensions (L×W×H)365 mm × 265 mm × 180 mm
Weight6.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelUltrapyc Series
Instrument TypeTrue Density Analyzer
Instrument ClassBenchtop Laboratory
Sample TypeSolids (bulk & granular), Powders, Pastes, Slurries, Foams
Density Accuracy≤0.015%
Display7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen
Temperature Range3–60 °C
Minimum Sample Volume0.1 cm³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelDMA 502
Instrument TypeOscillating U-tube Density Meter
Form FactorBenchtop Laboratory Instrument
Sample TypeLiquids and Low-Viscosity Suspensions
Density Range0 to 3 g/cm³
Density Accuracy±0.001 g/cm³
Density Repeatability±0.0002 g/cm³
Density Resolution0.0001 g/cm³
Temperature Range15–40 °C
Temperature Stability±0.1 °C
Minimum Sample Volume1 mL
Display7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen
Environmental CompensationAutomatic pressure, altitude, and ambient humidity correction
Data Storage5000 measurements
Method Library400 pre-validated methods
Conversion Tables140 built-in (alcohol, sugar, acids, API gravity, etc.)
ComplianceASTM D4052, ASTM D5002, USP <841>, EP/JP pharmacopoeial density requirements, FDA 21 CFR Part 11 (when used with AP Connect)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPerfume and Flavor Measurement System
Instrument TypeOscillating U-tube Densimeter
Instrument ClassBenchtop Laboratory
Sample TypeLiquid
Density Range0–3 g/cm³
Density Accuracy±0.01 g/cm³
Display10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen
Temperature Control Range0–100 °C
Minimum Sample Volume2 mL
Integrated ParametersDensity, Refractive Index, Optical Rotation, Colorimetry, Turbidity
AutomationFully Automated Sample Handling with Recovery (Xsample 5200/530), Integrated Cleaning & Drying
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelDMA 1102 Petro
Instrument TypeOscillating U-tube Densimeter
ApplicationPetroleum Products Density & Kinematic Viscosity Measurement
Detection MediumLiquid
Density Range0 g/cm³ to 3 g/cm³
Density Accuracy±0.0001 g/cm³
Density Resolution5 significant digits
Temperature Range15 °C to 100 °C (59 °F to 212 °F)
Temperature Stability±0.03 °C over full range
Viscosity Range−0.3 mm²/s to 1000 mm²/s
Viscosity Repeatability±0.2%
Minimum Sample Volume3.5 mL
Display7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen
Dimensions (L×W×H)365 × 265 × 180 mm
Weight6.6 kg
Power SupplyDC 24 V / 3 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelDMA 1002
Instrument TypeOscillating U-tube Densimeter
Form FactorBenchtop Laboratory Instrument
Sample TypeLiquid
Density Range0–3 g/cm³
Density Accuracy±0.0001 g/cm³
Density Repeatability±0.00005 g/cm³
Density Resolution0.00001 g/cm³
Temperature Range15–60 °C
Temperature Stability±0.02 °C
Minimum Sample Volume1 mL
Display7″ TFT WVGA Touchscreen (800 × 480 px, PCAP)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelDMA 6002 Sound Velocity
Instrument TypeOscillating U-tube Densimeter & Sound Velocity Analyzer
Form FactorBenchtop Laboratory Instrument
Sample TypeLiquids
Density Range0 g/cm³ to 3 g/cm³
Sound Velocity Range1000 m/s to 2000 m/s
Temperature Range0 °C to 100 °C (32 °F to 212 °F)
Pressure Range0 bar to 8 bar (0 psi to 116 psi)
Density Accuracy±0.000005 g/cm³
Density Repeatability (Std. Dev.)±0.000001 g/cm³
Sound Velocity Repeatability (Std. Dev.)±0.1 m/s
Density Reproducibility (Std. Dev.)±0.000005 g/cm³
Sound Velocity Reproducibility (Std. Dev.)±0.5 m/s
Density Resolution0.000001 g/cm³
Sound Velocity Resolution0.01 m/s
Minimum Sample Volume3.5 mL
Measurement ThroughputUp to 30 samples/hour
ComplianceISO 5725, ASTM D4052, ASTM D1250, ISO 12185, ISO 17025 (when operated with certified calibration standards)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelDMA 4002 / DMA 5002 / DMA 6002
Instrument TypeOscillating U-tube Densimeter
Instrument ClassBenchtop Laboratory Densimeter
Sample TypeLiquid
Density Range0 to 3 g/cm³
Density Accuracy±0.00005 g/cm³ (DMA 4002), ±0.00001 g/cm³ (DMA 5002, 0–1.05 g/cm³ at 15–20 °C), ±0.000005 g/cm³ (DMA 6002, full range)
Temperature Range0 °C to 100 °C
Temperature Accuracy±0.02 °C (DMA 4002), ±0.01 °C (DMA 5002 & DMA 6002, 15–20 °C)
Density Repeatability (Std. Dev.)0.00001 g/cm³ (DMA 4002), 0.000003 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002)
Density Resolution0.00001 g/cm³ (DMA 4002), 0.000005 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002)
Minimum Sample Volume1 mL
Display10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen
ComplianceASTM D4052, D5002, D1250
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelElaTest
Density Measurement Range0.8–2.6 g/cm³
Temperature Range0–40.0 °C
Repeatability±0.00001 g/cm³
Resolution0.0001 g/cm³
Minimum Sample Volume40–120 cm³
ApplicationDensity of uncured rubber and rubber compounds
Instrument TypeBenchtop Laboratory Densitometer
Detection PrinciplePneumatic (gas displacement) density measurement
ComplianceDesigned for GLP/GMP environments with audit-ready data handling
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare