- All
- Favorite
- Popular
- Most rated
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH (Petrotest Division) |
| Type | Imported Instrument |
| Model | PetroOxy |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | PMA 500 |
| Detection Method | Closed Cup Method |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient + X °C to 410 °C |
| Ignition Method | Electric Spark Ignition |
| Compliant Standards | ASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Callisto 100 |
| Temperature Range | –60 °C to +45 °C |
| Cooling Profile | Programmable stepwise or linear (6–100 °C/h) |
| Calibration | Automated calibration for sample/jacket temperature and vacuum |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 1000 test results |
| User Programs | Up to 90 customizable methods |
| External Cooling Required | Yes (280 W at –20 °C) |
| Dimensions | 340 × 580 × 310 mm (W × D × H) |
| Weight | 14 kg |
| Power Supply | 100–240 V, 50/60 Hz, 290 VA |
| Interfaces | 4× USB, 1× RS232, 1× LAN, 1× VGA |
| Data Export | XLS, PDF via USB flash drive |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Diana 700 |
| Test Pressure | Atmospheric (101.3 kPa) |
| Temperature Range | 0–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling Bath Range | 0–80 °C |
| Distillation Rate | 2–12 mL/min |
| Volume Detection Range | 0–103.5 mL |
| Volume Resolution | 0.01 mL |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | PMA 300 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient + ~10 °C to 370 °C |
| Ignition Source | Electronic (Encapsulated Hot-Wire) |
| Compliant Standards | ASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ABA 300 & ABA 500 |
| Detection Method | Closed-Cup (Abel) |
| Operation Mode | Fully Automatic |
| Temperature Range | 10 °C to 110 °C (air-cooled) |
| Ignition Source | Electronic (encapsulated hot-wire) |
| Repeatability | ±1.4 °C |
| Compliant Standards | ISO 13736, ISO 1516, ISO 1523, GB/T 21789, GB/T 21775, GB/T 21792 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ABA 500 |
| Detection Method | Closed Cup |
| Operation Mode | Automatic |
| Temperature Range | −35 °C to +130 °C |
| Ignition Method | Electronic (Encapsulated Hot Wire) |
| Applicable Standards | ISO 13736, ISO 1516, ISO 1523, GB/T 21789 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CLA 5 |
| Detection Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automated |
| Temperature Range | Up to 400 °C (°C/°F selectable) |
| Ignition Source | Pressurized Propane or Butane Gas |
| Compliant Standards | ASTM D92, ISO 2592, IP 36, DIN 51376, JIS K 2265 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar (Petrotest GmbH, a company of Anton Paar) |
| Model | GUM |
| Operating Temperature Range | Ambient to 246 °C (air only) |
| Sample Positions | 5 simultaneous |
| Air Supply | 2–4 bar, oil-free and filtered |
| Steam Supply | Inlet temperature ≈140 °C, pressure 3–4 bar, controlled flow rate |
| Power Requirements | 230 V, 50/60 Hz, 2000 W (air mode) |
| Dimensions (W × D × H) | 400 × 400 × 720 mm |
| Weight | 44 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | TAG500 |
| Detection Method | Closed-Cup (Tagliabue) |
| Operation Mode | Fully Automatic |
| Temperature Range | −30 °C to +130 °C |
| Ignition Source | Electronic (Encapsulated Hot-Wire) |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | TAG 300/500 |
| Detection Method | Closed-Cup (TAG) |
| Operation Mode | Fully Automatic |
| Sample Temperature Range | −35 °C to +130 °C |
| Ignition Source | Ceramic-Coated Electric Igniter |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH (Petrotest GmbH, a company of Anton Paar) |
| Product Category | Imported |
| Model | BPA |
| Price | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | PNR 12 |
| Pricing | Upon Request |
Show next