- All
- Favorite
- Popular
- Most rated
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Litesizer DLS Series |
| Particle Size Range | 0.3 nm – 15 µm (DLS, DLS 701) |
| Size Reproducibility | ±2% |
| Temperature Control Range | 0–120 °C |
| Temperature Stability | ±0.1 °C |
| Laser Frequency | 455 THz (658 nm diode laser) |
| Particle Sizing Method | Dynamic Light Scattering (DLS) and Static Light Scattering (SLS) |
| Sample Volume | 1.5 µL – 1 mL |
| Sample Concentration | up to 50% w/v |
| Zeta Potential Range | ±1000 mV |
| Measurement Time | < 60 s |
| Molecular Weight Range | 300 Da – 20 MDa |
| Zeta Potential Reproducibility | ±3% |
| Refractive Index Accuracy | ±0.5% (for DLS 701/501) |
| Transmission Monitoring | 0–100%, resolution <1% |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | Litesizer DLS 101 |
| Particle Size Range | 0.3 nm – 12 µm |
| Size Measurement Reproducibility | ±2% |
| Temperature Control Range | 0–120 °C |
| Temperature Stability | ±0.1 °C |
| Laser Frequency | 455 THz (658 nm diode laser) |
| Measurement Principle | Dynamic Light Scattering (DLS) |
| Sample Concentration Range | up to 50% w/v |
| Minimum Sample Volume | 1.5 µL |
| Zeta Potential Range | –500 mV to +500 mV |
| Typical Measurement Time | <1 min |
| Molecular Weight Range | 1 kDa – 20 MDa |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | Litesizer DLS |
| Particle Size Range | 0.3 nm – 15 µm (diameter) / 0.3 nm – 10 µm (diameter) |
| Size Reproducibility | ±2% |
| Temperature Control Range | 0–120 °C |
| Temperature Stability | ±0.1 °C |
| Laser Frequency | 455 THz |
| Size Measurement Principle | Dynamic Light Scattering (DLS) and Static Light Scattering (SLS) |
| Zeta Potential Range | ±1000 mV |
| Zeta Potential Reproducibility | ±3% |
| Molecular Weight Range | 300 Da – 20 MDa |
| Sample Volume | 1.5 µL – 1 mL |
| Concentration Range | up to 50% w/v |
| Measurement Time | <1 min |
| Transmission Monitoring | Real-time, 0–100% |
| Refractive Index Measurement Accuracy | ±0.5% (range: 1.28–1.50) |
| Optical Configurations | Fluorescence & polarization filters (15°, 90°, 175°) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Litesizer |
| Particle Size Range | 0.3 nm – 10 µm |
| Size Measurement Repeatability | ±2% |
| Temperature Control Accuracy | ±0.2 °C |
| Sample Concentration Range | 0.1 mg/L – 100 mg/L |
| Sample Volume Range | 12 µL – 1000 µL |
| Zeta Potential Range | −500 mV to +500 mV |
Show next