Empowering Scientific Discovery

Anton Paar (Shanghai) Trading Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelLitesizer DLS Series
Particle Size Range0.3 nm – 15 µm (DLS, DLS 701)
Size Reproducibility±2%
Temperature Control Range0–120 °C
Temperature Stability±0.1 °C
Laser Frequency455 THz (658 nm diode laser)
Particle Sizing MethodDynamic Light Scattering (DLS) and Static Light Scattering (SLS)
Sample Volume1.5 µL – 1 mL
Sample Concentrationup to 50% w/v
Zeta Potential Range±1000 mV
Measurement Time< 60 s
Molecular Weight Range300 Da – 20 MDa
Zeta Potential Reproducibility±3%
Refractive Index Accuracy±0.5% (for DLS 701/501)
Transmission Monitoring0–100%, resolution <1%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
ManufacturerAnton Paar GmbH
Product TypeImported Instrument
ModelLitesizer DLS 101
Particle Size Range0.3 nm – 12 µm
Size Measurement Reproducibility±2%
Temperature Control Range0–120 °C
Temperature Stability±0.1 °C
Laser Frequency455 THz (658 nm diode laser)
Measurement PrincipleDynamic Light Scattering (DLS)
Sample Concentration Rangeup to 50% w/v
Minimum Sample Volume1.5 µL
Zeta Potential Range–500 mV to +500 mV
Typical Measurement Time<1 min
Molecular Weight Range1 kDa – 20 MDa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
ManufacturerAnton Paar GmbH
Product TypeImported Instrument
ModelLitesizer DLS
Particle Size Range0.3 nm – 15 µm (diameter) / 0.3 nm – 10 µm (diameter)
Size Reproducibility±2%
Temperature Control Range0–120 °C
Temperature Stability±0.1 °C
Laser Frequency455 THz
Size Measurement PrincipleDynamic Light Scattering (DLS) and Static Light Scattering (SLS)
Zeta Potential Range±1000 mV
Zeta Potential Reproducibility±3%
Molecular Weight Range300 Da – 20 MDa
Sample Volume1.5 µL – 1 mL
Concentration Rangeup to 50% w/v
Measurement Time<1 min
Transmission MonitoringReal-time, 0–100%
Refractive Index Measurement Accuracy±0.5% (range: 1.28–1.50)
Optical ConfigurationsFluorescence & polarization filters (15°, 90°, 175°)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelLitesizer
Particle Size Range0.3 nm – 10 µm
Size Measurement Repeatability±2%
Temperature Control Accuracy±0.2 °C
Sample Concentration Range0.1 mg/L – 100 mg/L
Sample Volume Range12 µL – 1000 µL
Zeta Potential Range−500 mV to +500 mV