- All
- Favorite
- Popular
- Most rated
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ViscoQC 300 |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–320 mPa·s |
| Temperature Control Range | +15 °C to +80 °C (with PTD 80, DIN/SSA geometry) |
| Compliance Standards | ASTM D2196, ISO 2555, ISO 3219, ISO 16520, USP <911>, EN ISO 12058 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RheolabQC |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1 – 10⁹ mPa·s |
| Temperature Range | −20 to +180 °C |
| Speed Range | 0.01 – 1500 rpm |
| Torque Range | 0.25 – 75 mN·m |
| Shear Stress Range | 0.5 – 3×10⁴ Pa |
| Shear Rate Range | 0.01 – 4000 s⁻¹ |
| Angular Displacement Resolution | 2 µrad |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ViscoQC 100 |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–6,000,000 mPa·s (L), 10–40,000,000 mPa·s (R), 60–320,000,000 mPa·s (H) |
| Temperature Range | +15 °C to +80 °C |
| Temperature Accuracy | ±1.0 % of full scale |
| Speed Range | 0.1–200 rpm (19 standard + 6 user-definable speeds) |
| Torque Range | 0.067–75.7496 mN·m |
| Accuracy | ±1.0 % of full scale |
| Repeatability | ±0.2 % of full scale |
| Compliance | ISO 2555, ISO 3219, ASTM D2196, USP <911>, GMP/GLP-ready |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SVM 3001 Cold Properties |
| Instrument Category | Multiparameter Physical Property Analyzer |
| Instrument Type | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.2–30,000 mm²/s |
| Temperature Range | −60 °C to +100 °C |
| Compliance | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1), AT516302 (B1), CN105628550 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | SVM 1001 |
| Instrument Type | Portable Rotational Kinematic Viscometer |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.3 mm²/s to 5000 mm²/s |
| Temperature Range | +15°C to +100°C (+59°F to +212°F), dual-temperature capability (one primary + one optional) |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ±1°C |
| Viscosity Repeatability | 0.1% |
| Viscosity Reproducibility | 0.35% |
| Temperature Repeatability | 0.005°C |
| Temperature Reproducibility | 0.03°C across full range |
| Sample Volume | 1.5 mL (minimum), 5 mL (standard) |
| Solvent Volume | 1.5 mL (minimum), 6 mL (standard) |
| Throughput | up to 37 samples/hour (Ultra-Fast Mode) |
| Compliance | ASTM D445, ASTM D7042, ISO 23581, EN 16896 |
| Data Storage | 1,000 measurements |
| Display | 7″ capacitive touchscreen |
| Interface | 4 × USB (3 × Type-A, 1 × Type-B) |
| Power Supply | DC 24 V / 3 A |
| Environmental Conditions | +15°C to +35°C, ≤80% RH (non-condensing) |
| Certifications | CE, EMC EN 61326-1, Safety EN 61010-1, RoHS |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | SVM 3001 |
| Instrument Type | Benchtop Fixed-Station Analyzer |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.2 to 30,000 mm²/s |
| Temperature Range | −60 °C to +135 °C |
| Compliance | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1), AT516302 (B1), CN105628550 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Lovis 2001 |
| Instrument Type | Fixed-Position Falling-Ball Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.2 to 10,000 mPa·s |
| Temperature Range | 5 °C to 100 °C (41 °F to 212 °F) |
| Temperature Resolution | 0.005 °C |
| Temperature Accuracy | ±0.02 °C |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SVM Series |
| Instrument Category | Kinematic Viscometer |
| Instrument Form Factor | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.2 to 30,000 mm²/s |
| Temperature Control Range | 15 °C to 100 °C (standard) |
| Compliance | ASTM D7042, ASTM D445 (with bias correction), ISO 23581, EN 16896, ASTM D4052, ISO 12185, ASTM D2386, ASTM D2500, ASTM D396, D975, D1655, D3699, D6158, D6823, D7467 |
| Patents | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1), AT516302 (B1), CN105628550 |
Show next