- All
- Favorite
- Popular
- Most rated
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | ET 02II |
| Standards Compliance | ISO 1432, ASTM D1053 |
| Test Stations | 6 independent automated stations |
| Temperature Control | Computer-regulated ramp (–70 °C to +100 °C, optional LN₂ cooling) |
| Output Parameters | RM2, RM5, RM10, RM100 torsional rigidity indices |
| Data Presentation | Real-time graphical curves + tabular export |
| Software | Windows-based control & analysis suite with audit trail capability |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | ET 05II |
| Compliance Standards | ISO 812, ISO 974, ASTM D746, ASTM D2137 |
| Operating Pressure | 6 bar compressed air required |
| Test Principle | Instrumented drop-weight impact with controlled thermal conditioning |
| Temperature Control | Computer-regulated cryogenic chamber (–70 °C to +50 °C typical range) |
| Impact Velocity Measurement | High-speed optical sensor with pre- and post-impact velocity verification |
| Energy Delivery | Adjustable via drop height and calibrated hammer mass |
| Software | Windows-based control & analysis suite with audit trail and report generation |
| Brand | Karg |
|---|---|
| Origin | Germany |
| Model | SC-1693 |
| Temperature Range | 50–100 °C |
| Test Compliance | ASTM D1693 |
| Notch Dimensions | 19.0 ± 0.5 mm (length) × 0.50 ± 0.05 mm (depth) |
| Specimen Dimensions | 38.0 ± 2.5 mm × 13.0 ± 0.08 mm (rectangular) |
| Notch Geometry | U-shaped cross-section |
| Test Vessel | Borosilicate glass tubes |
| Heating System | Precision thermostatic bath with ±0.3 °C stability |
| Control Interface | Integrated digital controller with timer and temperature logging |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | FMVSS 302 |
| Compliance | FMVSS 302, ISO 3795, DIN 75200 |
| Chamber Material | V4A Stainless Steel (1.4404 / AISI 316L) |
| Sample Holder | Type A & Type B Configurations |
| Flame Source | Adjustable Propane/Butane Burner with Precision Needle Valve |
| Viewing Window | Heat-Resistant Borosilicate Glass |
| Service Access | Side Maintenance Door |
| Optional Fixtures | VW TL 1010 & Porsche PTL 8501 Compliant Sample Clamps |
| Dimensions (W×H×D) | 500 × 385 × 245 mm |
| Weight | 22 kg |
| Brand | Koehler |
|---|---|
| Origin | Germany |
| Model | ED Series |
| Temperature Range | Ambient +5°C to 300°C |
| Control System | DS Controller with Integrated Timer (0–99 h) |
| Temperature Setting Resolution | Digital, 0.1°C |
| Alarm | Visual Temperature Alarm |
| Airflow Adjustment | Rear Ventilation Flap (Ø50 mm) + Front Ventilation Slider |
| Standard Interior Volume Options | 20 L, 53 L, 115 L, 240 L, 400/700 L |
| Standard Shelves | 2 Nickel-Plated Adjustable Shelves |
| Interface Option | RS422 for APT-COM Data Control Software |
| Compliance | Designed for GLP/GMP-aligned laboratory environments |
| Brand | Karg |
|---|---|
| Origin | Germany |
| Model | HST 53-3 |
| Temperature Control Range | Room Temperature +5°C to 300°C |
| Internal Chamber Volume | 53 L |
| Internal Dimensions (W×H×D) | 400 × 400 × 330 mm |
| External Dimensions (W×H×D) | 635 × 620 × 575 mm |
| Timer Range | 0–99 hours |
| Power Supply | 220 V AC ±10% |
| Compliance | DIN EN 60811-2-1 |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | DIN 53438 |
| Compliance | DIN 53438, DIN 4102-B2 |
| Chamber Dimensions (W×H×D) | 730 × 950 × 450 mm |
| Weight | 65 kg |
| Sample Holder | Adjustable-angle stainless steel support with interchangeable fixtures |
| Burner | Tilt-adjustable Bunsen-type burner with calibrated flame height indicator |
| Gas Control | Precision mass-flow regulated propane/butane supply system |
| Viewing Window | Heat-resistant borosilicate glass front panel |
| Exhaust | Integrated axial exhaust fan with duct interface |
| Safety Features | Front-access design, thermal insulation, fail-safe gas shutoff |
| Brand | Kegge |
|---|---|
| Origin | Germany |
| Model | proTens |
| Maximum Load Capacity | 250 kN |
| Drive System | Dual-arm screw-driven with solid-state servo and electric control |
| Load Resolution | 120,000 counts |
| Load Accuracy | Class 1 per DIN EN ISO 7500 (0.4–100% of full scale) |
| Test Speed Range | 0.01–2000 mm/min |
| Motor Power Options | 300 W or 900 W |
| Software Interface | Human-centered, compliant with GLP/GMP data integrity requirements |
| Safety Features | Adjustable overload shutdown, quick-release sensor & grip system, precision crosshead guidance |
| Sample Compatibility | Metals, plastics, elastomers, foams, paper, wood, textiles, wires, and finished components |
| Test Modes | Tension, compression, bending, shear, peel |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | EP 04-II |
| Max Operating Temperature | 300 °C |
| Internal Volume | 60 L |
| Air Exchange Rate | Adjustable 3–20 air changes per hour |
| Compliance | IEC 60811, ISO 188 |
| Chamber Airflow | Controlled forced convection |
| Optional Accessories | EB 04AP (external sensor port), EB 04IIW (viewing window with illumination), EB 04IIDC (door interlock safety switch) |
| Brand | Kegge |
|---|---|
| Origin | Germany |
| Model | smarTens |
| Load Capacity | 20 kN |
| Load Accuracy | Class 1 per DIN EN ISO 7500 (optional Class 0.5) |
| Crosshead Positioning Accuracy | < 1 µm |
| Speed Range | 0.01–1000 mm/min |
| Control System | Solid-state servo motor with dual-arm screw drive |
| Software | Integrated PC-based control and analysis platform |
| Compliance | DIN EN ISO 7500-1, ASTM E4, ASTM E8/E21, ISO 6892-1, ISO 178, ISO 14129, ISO 14130 |
| Sample Compatibility | Metals, plastics, elastomers, foams, paper, wood, textiles, composites, wire, finished components |
| Safety Features | Adjustable overload cutoff, quick-release load cell & fixture interface, precision crosshead guidance system |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | ET 06BASEII |
| Temperature Range | −80 °C to +20 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Uniformity | ±0.5 °C |
| Heating Rate | 1 °C/min |
| Cooling Rate | 0.5 °C/min |
| Temperature Resolution | 0.1 °C |
| Test Stations | 6 |
| Compliance | ISO 2921, ASTM D1329, ISO 812, ASTM D746, ISO 2818 (Gere twist), ASTM D1043 |
| Brand | Kaelge |
|---|---|
| Origin | Germany |
| Model | IMPact 5.5/15(25) |
| Impact Energy Range | 0.5–5.5 J (IMPact 5.5) |
| Compliance Standards | EN ISO 179, EN ISO 180, ASTM D 256 (Methods A & B), ISO 8256 |
| Test Configurations | Charpy (simply supported beam), Izod (cantilever beam), Tensile Impact |
| Control System | Microprocessor-based with keypad and LCD display (4-language support) |
| Output Interfaces | RS-232 serial port, parallel printer port |
| Key Functions | Automatic pendulum braking, built-in sample centering for Charpy fixtures, real-time energy calculation (absorbed energy, recovered elastic energy, rise angle, impact velocity), on-access auto-test initiation, pendulum calibration verification and report generation, FIFO storage of up to 50 test results with statistical evaluation (mean, standard deviation) |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Instrument Type | Free-Fall Dart Impact Tester |
| Standards Compliance | ASTM D1709, ISO 7765-1 |
| Impact Energy Range | As per manufacturer’s specification sheet |
| Impact Velocity | As per manufacturer’s specification sheet |
| Dart Mass Options | Standardized (e.g., 50 g, 100 g, 200 g) per ASTM/ISO |
| Maximum Drop Height | Adjustable up to 2,000 mm (typical range) |
| Load Cell Capacity | Configurable (e.g., ±500 N full scale) |
| Test Mode | Single-dart or multi-dart statistical mode (50% failure threshold determination) |
| Data Output | Analog + digital (RS-232 / USB) |
| Safety Enclosure | Interlocked transparent polycarbonate shield |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | EV 01 |
| Compliance | ISO 23529 (Thickness), ISO 815 (Compression Set) |
| Measurement Range | 0–10 mm (with 10 mm reference spacer included) |
| Resolution | 0.001 mm |
| Interface | RS-232 or USB (via optional EC 01.04 interface kit) |
| Software | EC 02 v3.x for data logging, statistical analysis, trend plotting, and report generation |
| Calibration | Traceable to NIST-equivalent national standards (per ISO/IEC 17025-accredited calibration certificate available) |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | EB 01-II |
| Max Operating Temperature | 300 °C |
| Chamber Configuration | 4 identical-temperature zones |
| Sample Capacity | 24 standard specimens per chamber |
| Temperature Uniformity | ±0.5 °C |
| Heating Method | Channelled aluminum block preheating |
| Airflow | Natural convection, low-velocity, no forced circulation |
| Compliance | IEC 60811-1-2, ISO 188, ASTM D573 |
| Software Interface | PC-connected, wireless data acquisition via laser-guided arm and digital calipers |
| Brand | Bareiss |
|---|---|
| Origin | Germany |
| Model | HDA 325 |
| Hardness Measurement Principle | Shore A (ASTM D2240, ISO 7619-1) |
| Density Measurement Principle | Archimedes’ Principle with Precision Buoyancy Weighing |
| Cycle Time (Hardness + Density) | <20 s per sample |
| Dual-Channel Density Option | ~10 s per sample |
| Operating Duty Cycle | 24/7/365 continuous operation |
| Temperature Monitoring Option | Integrated surface temperature sensor (range: 20–70 °C, resolution: ±0.1 °C) |
| Data Traceability | Sample ID, timestamp, operator ID, environmental metadata |
| Compliance | ISO/IEC 17025-ready architecture, supports GLP/GMP audit trails, FDA 21 CFR Part 11 compliant data handling (with optional electronic signature module) |
| Brand | Bareiss |
|---|---|
| Origin | Germany |
| Model | DT Chamber |
| Temperature Range | -70 °C to +180 °C (customizable) |
| Hardness Scales | Shore A, Shore D, IRHD |
| Sample Capacity | Up to 25 specimens (customizable) |
| Test Modes | Single-point, continuous, programmable, hysteresis recovery (IRHD) |
| Instrument Type | Shore / IRHD Hardness Tester |
| Brand | Kägi |
|---|---|
| Origin | Germany |
| Model | Micro IRHD |
| Instrument Type | Microindentation Hardness Tester for Elastomers |
| Standards Compliance | DIN ISO 48, ISO 48:2018, ASTM D1415-19, BS 903-A26 |
| Sample Thickness Range | 1–5 mm (recommended), up to 90 mm (with optional fixtures) |
| Resolution | 0.1 Micro IRHD |
| Dimensions (Tester) | Ø200 mm × 470 mm |
| Dimensions (Controller) | 290 mm × 260 mm × 75 mm |
| Weight | 17.5 kg |
| Control Interface | RS232 serial communication with Windows PC |
| Automation | Motorized Z-stage, programmable dual-weight actuation, auto-positioning sample stage |
| Software Platform | Native MS Windows application with real-time data acquisition, statistical analysis, hysteresis calculation, report generation (PDF/CSV), label printing, and ASCII export |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | UL94 |
| Chamber Material | Polished Stainless Steel |
| Burner Adjustment | Horizontal travel 240 mm, angular tilt 0°/20°/45° |
| Specimen Holder Travel | Horizontal 840 mm, Vertical 730 mm |
| Specimen Holders | 5 types for multi-standard compliance |
| Timer Range | 0–100 s in 1-s increments |
| Airflow Control | Integrated mass-flow regulated exhaust system |
| Exhaust Fan | Variable-speed centrifugal fan |
| External Dimensions (W×H×D) | 1500 × 1500 × 600 mm |
| Net Weight | 200 kg |
| Applicable Standards | UL 94, ASTM D635, ASTM D3801, ASTM D4804, ASTM D5048, ASTM D4986, IEC 60695-11-10 (replaces ISO 1210), IEC 60695-11-20 (replaces ISO 10351), ISO 9772, ISO 9773 |
| Brand | Ortelli |
|---|---|
| Origin | Italy |
| Model | MVS2pro |
| Instrument Type | Buoyancy-Based Density Analyzer |
| Configuration | Benchtop Laboratory System |
| Sample Type | Solids (films, rods, granules) |
| Density Range | 0–2 g/cm³ |
| Temperature Control Range | 10–40 °C (standard test temp: 23 °C) |
| Cycle Time | ~3–5 min per sample |
| Auto-sampler Capacity | 16-position robotic arm |
| Compliance | ISO 1183-1, ISO 9001 |
| Brand | VMI |
|---|---|
| Origin | Netherlands |
| Model | LAT-100 |
| Instrument Type | Multi-Functional Tribological Tester |
| Normal Load Range (Fz) | 10–140 N |
| Lateral Force Range (Fy) | −120 to +120 N |
| Friction Force Range (Fx) | 5–100 N |
| Speed Range (Low) | 0.002–2 km/h |
| Speed Range (High) | 2–100 km/h |
| Slip Angle Range | −45° to +45° |
| Mass Measurement Range | 220 g |
| Surface Temperature Range | −18°C to +150°C |
| Water Temperature Range | 1°C to 80°C |
| Cryo Temperature Range (with optional Kryo module) | −30°C to +80°C |
| Abrasion Disc Diameter | 350 mm |
| Abrasion Disc Thickness | 25 mm |
| Disc Materials | Al₂O₃ (EKW 60, EKW 180), SGG Glass |
| Dual-Sided Discs | Yes |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | Kofler HB |
| Type | Hot-block melting point apparatus |
| Principle | Kofler hot-plate method (linear temperature gradient) |
| Application | Rapid qualitative and semi-quantitative melting point determination of organic crystalline solids |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 4E-MC |
| Pricing | Upon Request |