Empowering Scientific Discovery

Beijing Beifen-Sanpu Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGDYS-101SV
ApplicationQuantitative sulfide analysis in drinking water, surface water, domestic wastewater, and treated effluent
Detection MethodColorimetric (methylene blue method per GB/T 5750.5–2006)
Detection Time≤10 min
Detection Limit0.02 mg/L
Measurement Range0.00–1.00 mg/L
Accuracy±5%
Power Supply9 V alkaline battery (operational life ≥40 h)
Reagent FormatSingle-use, pre-packaged assay kits (50 tests per kit)
Included AccessoriesComplete set of colorimetric glassware and reagents (50 assays)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorth Branch Sanpu
OriginHebei, China
Manufacturer TypeDirect Manufacturer
ModelSF-1
Measurement PrincipleCoulometric Karl Fischer (KF) Titration
Detection Range3 µg – 100 mg H₂O
Resolution1 µg H₂O
Accuracy±3 µg H₂O (≤1 mg), ±0.3% of reading (>1 mg)
Electrolysis Current0–300 mA, auto-controlled
Display4-digit high-brightness LED
Endpoint IndicationAudible alert + visual LED indicator
Drift CompensationMicroprocessor-based automatic compensation
StirringContinuously variable speed control
PowerAC 220 V ±11 V, 50 Hz ±2.5 Hz
Dimensions320 mm × 260 mm × 90 mm
WeightApprox. 4.2 kg
Operating Temperature5–45 °C
Relative Humidity≤80% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelGDYS-101SE2
ApplicationField and Laboratory Quantitative Determination of Chlorine Dioxide in Water Samples
Light Source520 nm LED
Optical Stability±0.005 Abs/20 min
Detection Limit0.02 mg/L
Measurement Range0.00–3.00 mg/L
Measurement Time1 minute
Accuracy±5%
Power SupplyDC 9 V battery
Auto Power-OffAfter 30 minutes idle
Battery Status IndicatorIntegrated low-battery diagnostic circuit
ComplianceGB/T 5750.11–2006 (Standard Method for Examination of Disinfectants in Drinking Water)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginHebei, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelSF101
ApplicationMulti-purpose coulometric moisture determination for liquids, gases, and solids
Measurement PrincipleCoulometric Karl Fischer titration (电量法)
Display7-inch color TFT LCD touchscreen with Chinese UI
Electrolysis Current Range0–400 mA (auto-controlled)
Measurement Range0.1 µg – 200 mg H₂O (equivalent to 0.1 ppm – 100% w/w)
Resolution0.1 µg H₂O (0.1 ppm)
Accuracy≤ ±0.2% for samples ≥1 mg H₂O
Data Storage256 test records
Sample Introduction ModesVolumetric injection, gravimetric weighing, and dilution-based injection
Automatic Unit Conversionµg H₂O, ppm, % w/w, mg H₂O/L, and mean values
PrinterHigh-speed thermal micro-printer
Power Consumption60 W
Operating Temperature5–45 °C
Relative Humidity Limit≤80% RH
Dimensions (W×D×H)350 × 230 × 180 mm
Weight8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginHebei, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelZFSZ100
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGDYS-101SQ2
ApplicationOn-site quantitative determination of Chemical Oxygen Demand (COD) in industrial wastewater
Measurement PrincipleSealed reflux digestion coupled with colorimetric detection per GB 11914–1989
Detection Time20 min per sample
Power Supply9 V alkaline battery (up to 40 h continuous operation)
Detection Limit30 mg/L
Range0–300 mg/L
Accuracy±5%
Kit Includes1 set of colorimetric apparatus, 1 set of sample pretreatment tools, and 1 reagent kit (50 determinations)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelGDYS-101SN
ApplicationField-deployable photometric analyzer for residual and total chlorine in water
Detection MethodDPD colorimetric method per GB/T 5750.11–2006
Detection Time≤3 min
Detection Range0.00–9.99 mg/L Cl₂
LOD0.10 mg/L
Accuracy±5% of reading
Power Supply9 V alkaline battery (≥40 h continuous operation)
Reagent FormatSingle-use, pre-packaged DPD reagent kits (50 tests per kit)
Included AccessoriesComplete set of calibrated colorimetric cuvettes and reagents (50 tests)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginHebei, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelZFMD102
PricingAvailable Upon Request
Temperature Control RangeAmbient to 100 °C
Temperature Stability±0.1 °C
Sample Positions2
Power Rating1000 W
Supply VoltageAC 220 V ±20%, 50 Hz ±10%
Operating Ambient0–40 °C, ≤85% RH
Dimensions (W×D×H)440 × 350 × 550 mm
Display320 × 240 dot-matrix LCD with capacitive touch keys
InterfaceRS-232 serial port
Thermal PrinterIntegrated high-speed thermal printer with offline printing capability
Compliance StandardGB/T 1884–1992
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginHebei, China
Manufacturer TypeDirect Manufacturer
ModelKS100
ComplianceGB/T 267–1988, GB/T 3536–2008, GB/T 1671–2008, ASTM D92
Measurement RangeAmbient to 400 °C
Accuracy±2 °C
Repeatability≤3 °C
Temperature Resolution0.1 °C
SensorImported Class A PT100 Platinum Resistance Thermometer
Ignition DetectionIonization Ring Sensor
Power SupplyAC 220 V ±20%, 50 Hz ±10%
Rated Power400 W
Dimensions440 × 280 × 290 mm
Weight18 kg
Operating Environment0–40 °C, ≤85% RH
Control InterfaceCapacitive Touchscreen with Screen Protection
Data Storage255 Test Records with Timestamps
Heating ControlAdaptive PID Algorithm per Standard Protocols
Atmospheric CompensationIntegrated Barometric Sensor with Auto-Calibration
Ignition OptionsSelectable Electronic Spark or Gas Flame Ignition
Multi-Furnace CapabilitySingle Host Controls Multiple Independent Test Furnaces
Automation LevelFull Cycle Automation (Heating, Lid Opening, Ignition, Flash Detection, Alarm, Cooling, Reporting)
Built-in Thermal PrinterHigh-Speed, Dot-Matrix, Offline Printing Support
Self-Diagnostic SystemReal-Time Sensor Health Monitoring and Over-Temperature Safeguard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield
ModelBS100
Measurement RangeAmbient to 350 °C
Accuracy±1 °C (≤104 °C), ±2 °C (>104 °C)
Repeatability±2 °C
Temperature Resolution0.1 °C
Temperature SensorImported Class A PT100 Platinum Resistance Thermometer
Ignition DetectionThermocouple-based Flash Sensor
Power SupplyAC 220 V ±20%, 50 Hz ±10%
Power Consumption400 W
Dimensions440 × 280 × 290 mm
Weight18 kg
Operating Environment0–40 °C, ≤90% RH
ComplianceGB/T 261–2008, ISO 2719, ASTM D93
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
ModelKS-1
Standard ComplianceGB/T 3536, ASTM D92
Flash Point RangeAmbient to 400 °C
Repeatability±2 °C (≤150 °C), ±4 °C (>150 °C)
Power Supply220 VAC, 50 Hz
Power Consumption400 W
Temperature ControlSolid-State Voltage Regulator (Continuous Ramp)
Dimensions (W×D×H)285 × 185 × 350 mm
Net Weight7 kg
OriginHebei, China
Manufacturer TypeOEM/ODM Producer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelGDYS-101SN2
ApplicationQuantitative residual chlorine analysis in water samples
Detection MethodDPD colorimetric method per GB/T 5750.11–2006
Detection Time≤3 minutes
Detection Range0.00–5.00 mg/L
Lower Detection Limit0.05 mg/L
Accuracy±5% of reading
Power Supply9 V alkaline battery (operating life: ≥40 hours)
Reagent FormatSingle-use, pre-packaged DPD reagent kits (50 tests per kit)
Accessories IncludedComplete set of calibrated colorimetric cuvettes and reagents (50 tests)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0