| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | JAHS-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Valve & Transfer Line Heating Range | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Pressure Control | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–1800 s |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–1800 s |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB 2.0 |
| Compliance | ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 ready (with optional audit trail software module) |
| Brand | Beifen Sanpu |
|---|---|
| Model | NAHS-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 / 2 / 5 mL) |
| Sample Heating Range | 40–220 °C (extendable to 300 °C) |
| Valve & Transfer Line Heating Range | 40–220 °C (extendable to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Carrier Gas Flow Control | EPC-electronic pressure control (optional) |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Compliance | Compatible with ASTM D6866, ISO 11843-2, USP <467>, and FDA 21 CFR Part 11–compliant data handling when integrated with validated GC software |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | FTDS-III |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | MAHS-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (up to 300 °C optional), ±0.5 °C stability |
| Valve & Transfer Line Heating | 40–220 °C (up to 300 °C optional), ±0.5 °C stability |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Clean Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow (Purge/Backflush) | 0–100 mL/min (adjustable) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB communication with PC |
| Valve Configuration | High-inertness 6-port valve with heated connection points |
| Tubing Material | Deactivated fused-silica or SilcoNert®-treated stainless steel |
| Power Supply | 220 V AC, 50 Hz |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | CA-Z300 |
| Pricing | Upon Request |
| Heating Units | 6 independent channels |
| Heating Method | Far-infrared ceramic heating (bowl-shaped, flameless, waterproof) |
| Power per Channel | 0–800 W (adjustable) |
| Temperature Control | Precise PID-controlled constant-temperature heating |
| Distillation Endpoint Detection | High-accuracy pressure-based load cell sensor (1–500 mL weight threshold, ±1 g repeatability) |
| Cooling System | Closed-loop internal recirculation with dual-stage cooling (air-cooled condenser + built-in compressor |
| temp range | 5–30 °C) |
| Anti-Suckback Protection | Vacuum-sensing solenoid valve with real-time pressure feedback |
| Condenser Cleaning | One-touch automated rinse function for all six condensers |
| Water Reservoir | Auto-fill with overflow cutoff |
| Display | 7-inch capacitive color touchscreen |
| Distillation Rate | 2–12 mL/min |
| Ramp Time | 5–8 min to set temperature |
| Timer Range | 1–999 min |
| Max Total Power | 5500 W (dynamically adjustable) |
| Flask Compatibility | Six 500 mL or 250 mL round-bottom flasks (custom configurations available) |
| Receiver Flexibility | Universal holder accepts volumetric flasks, Erlenmeyer flasks, graduated cylinders, beakers, etc. |
| Dimensions (L×W×H) | 1000 × 520 × 800 mm |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | Beifen Sanpu |
|---|---|
| Model | AHSG-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (configurable up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | <±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Cleaning Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (customizable: 0.5/2/5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50/100 mL) |
| Sample Positions | 20 |
| Simultaneously Heated Samples | 1 or 2 |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (continuously adjustable) |
| Interface | USB |
| Compliance | ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 (software-enabled audit trail) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | EAHS-20A Plus |
| Price | USD 7,800 (FOB Beijing) |
| Sample Capacity | 20 positions |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (optional up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Size Compatibility | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Interface | USB communication with PC control + local panel operation |
| Valve Type | High-inertness 6-port valve with heated connection point |
| Sample Transfer Line | Deactivated fused-silica tubing |
| Drive Mechanism | Stepper motor actuation (no external gas required) |
| GC Synchronization | TTL/relay trigger for GC start and data system launch |
| Brand | Beifen Sanpu |
|---|---|
| Model | AHSA-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 / 2 / 5 mL) |
| Sample Heating Range | 40–220 °C (extendable to 300 °C) |
| Valve & Transfer Line Heating Range | 40–220 °C (extendable to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Carrier Gas Flow Control | EPC optional |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Backflush Flow Rate | 0–100 mL/min (adjustable) |
| Interface | USB |
| Sample Handling | Liquid and solid matrices |
| Inert Flow Path | Deactivated fused-silica tubing and high-inertness valve components |
| Drive Mechanism | Motor-driven (no external gas required) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BF-9860 |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | ATDS-20A |
| Pricing | Upon Request |
| Sample Capacity | 20 positions |
| Cold Trap Temperature Range | −35 °C to ambient |
| Primary Desorption Temp | RT–450 °C |
| Secondary Desorption Temp | RT–450 °C |
| Valve & Transfer Line Temp | RT–300 °C |
| Temperature Control Accuracy | < ±0.5 °C |
| Desorption Recovery Rate | >99% (compound-dependent) |
| RSD | ≤2.5% (benzene in 0.05 μg methanol) |
| Enrichment Time | 0–60 min |
| Injection Time | 0–60 min |
| Sampling Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Carrier Gas Flow (Purge/Backflush) | 0–100 mL/min |
| Simulated Sampling Flow | 0–160 mL/min |
| Heating Ramp Rate (2nd Stage) | >3000 °C/min |
| Dimensions (L×W×H) | 350 × 450 × 510 mm |
| Weight | ~40 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | Domestic (China) |
| Model | CA-E2000 |
| Price | Upon Request |
| Heating Method | Far-infrared Ceramic Heater |
| Distillation Positions | 6 independent channels |
| Cooling System | Integrated Compressor-based Closed-loop Recirculating Chiller (Condensate Temp. <15 °C) |
| Nitrogen Flow Control | 0–2 L/min per channel (adjustable) |
| Timing Range | 1–999 min per channel (individual programmable) |
| Anti-suckback Valve | Integrated electromagnetic anti-backflow valve |
| Stirring | Built-in magnetic stirrer per receiving flask (speed adjustable) |
| Titration Fixture | Dedicated titration clamp integrated on mainframe |
| Power Consumption | ≤5000 W total (per-channel power adjustable) |
| Distillate Rate | 2–12 mL/min (channel-specific) |
| Heating Ramp Time | 5–8 min to setpoint |
| Flask Capacity | Six 1000 mL round-bottom flasks (customizable) |
| Dimensions (Main Unit) | 1100 × 470 × 800 mm |
| Dimensions (Compressor Unit) | 710 × 480 × 880 mm |
| Voltage | AC 220 V / 50 Hz |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AwTDS-20A |
| Temperature Control Range (Desorption 1) | Ambient to 450 °C (1 °C increments) |
| Valve & Transfer Line Temp Range | Ambient to 300 °C (1 °C increments) |
| Cryogenic Trap Temp Range | −35 °C to Ambient (1 °C increments, electronic cooling) |
| Temperature Accuracy | < ±0.5 °C |
| Desorption Recovery | >99% (compound-dependent) |
| RSD | ≤2.5% (benzene at 0.05 μg) |
| Sample Capacity | 20 positions |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Re-injection & Backflush Flow | 0–100 mL/min (adjustable) |
| Simulated Sampling Flow | 0–160 mL/min (adjustable) |
| Enrichment Time | 0–60 min |
| Injection Time | 0–60 min |
| Heating Rate (2nd Stage) | >3000 °C/min |
| Dimensions | 350 × 450 × 510 mm |
| Weight | ~40 kg |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | FAHS-20A Plus |
| Sample Capacity | 20-position |
| Vial Size Compatibility | 10 mL & 20 mL (customizable up to 100 mL) |
| Sample Heating Range | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Valve & Transfer Line Heating | 40–220 °C (optional to 300 °C), ±0.5 °C stability |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Clean Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Quantitative Loop Volume | 1 mL (0.5/2/5 mL optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| Interface | USB |
| Inert Flow Path | Deactivated fused-silica and PEEK tubing throughout |
| Valve Configuration | High-precision 6-port valve with minimized dead volume |
| Power Supply | AC 220 V ±10%, 50/60 Hz] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | CAHS-20A Plus |
| Sample Capacity | 20 positions |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (optional up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Quantitative Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Compatibility | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Simultaneous Heating | 1 or 2 vials |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Compliance | ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 (software-enabled audit trail) |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | CA-S2000 |
| Price | Upon Request |
| Sample Capacity | 6 positions |
| Heating Method | PID-controlled constant-temperature water bath, acid/alkali-resistant one-piece bath tank |
| Heating Power | 1500 W |
| Nitrogen Flow Range | 10–800 mL/min per channel |
| Temperature Range | Ambient to 99.9 °C |
| Temperature Control Accuracy | ±1 °C |
| Reaction Vessel Volume | 500 mL |
| Inlet Nitrogen Pressure | 0.1 MPa |
| Independent Flow Control | Yes (6 channels) |
| Safety Features | Dual pressure relief valves |
| Timing Function | Programmable nitrogen purge duration with auto-shutoff |
| User Interface | Color TFT touchscreen, ergonomic sloped front panel |
| Auto-refill Function | Yes |
| Rack Material | High-temp, acid/alkali-resistant polymer |
| Brand | Beifen Sanpu |
|---|---|
| Model | AHSC-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (optional up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Quantitative Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Simultaneous Heating | 1 or 2 vials |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Compliance | ASTM D6866, ISO 17025-compatible operation |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CA-Z200 |
| Pricing | Upon Request |
| Heating Method | Far-infrared ceramic heating elements (domestic) |
| Endpoint Control | Time-based auto-stop, ±2 mL accuracy |
| Cooling System | Built-in compressor-based recirculating chiller, condenser temperature <30 °C |
| Display | 7-inch resistive color touchscreen |
| Heating Units | 6 independent channels, 1–800 W per unit (adjustable) |
| Ramp-up Time | 5–8 min |
| Sample Capacity | 1–6 samples, individually controllable |
| Total Rated Power | 4800 W (adjustable) |
| Distillation Rate | 8–12 mL/min |
| Anti-suckback Protection | Solenoid vacuum valve integrated |
| Timer Range | 0–999 min |
| Receiving Vessel Compatibility | Universal (volumetric flasks, Erlenmeyer flasks, graduated cylinders, beakers) |
| Power Input | Dual-input AC |
| Voltage/Frequency | 220 V / 50 Hz |
| Dimensions (L×W×H) | 1000 × 520 × 800 mm |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AHS-20A Plus |
| Sample Capacity | 20-position |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (configurable up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | <±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Size Compatibility | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Clean Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| RSD | <1.0% (100 ppm ethanol in water) |
| Interface | USB |
| Valve Type | High-inertness 6-port valve with heated connection point |
| Transport Lines | Deactivated fused-silica capillary tubing |
| Drive Mechanism | Motor-driven (no external gas required) |
| Compliance | ASTM D3792, ISO 11843-2, USP <467>, EPA Method 502.2, 524.2, 8240, 8260] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | AeTDS-20A |
| Price | USD 21,800 (FOB Beijing) |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CA-Z100 |
| Heating Method | Far-infrared Ceramic Heater (Domestic) |
| Number of Heating Units | 6 |
| Adjustable Power per Unit | 1–800 W |
| Total Rated Power | 4800 W (adjustable) |
| Distillation Rate | 8–12 mL/min |
| Endpoint Control | Time-based, 0–999 min adjustable, ±2 mL accuracy |
| Cooling | External Compressor Chiller or Tap Water, Condenser Temperature <30 °C |
| Display | 7-inch Resistive Touchscreen |
| Sample Capacity | 1–6 independent channels |
| Heating Uniformity | Uniform Far-infrared Radiation |
| Anti-Backsuction | Integrated Silicone Stopper & PE Tube Assembly |
| Distillation Vessel | 500 mL Round-Bottom Flask (6 pcs) |
| Condenser | Coiled Reflux Condenser (6 pcs) |
| Receiving Vessels | Compatible with Volumetric Flasks (250 mL), Erlenmeyer Flasks, Graduated Cylinders, Beakers |
| Power Supply | Dual-input 220 V / 50 Hz |
| Dimensions (L×W×H) | 1000 × 520 × 800 mm |
| Compliance | Verified Recovery Rate ≥95% in CAL/ISO/IEC 17025 Accredited Laboratories for Phenols, Ammonia Nitrogen, Cyanide, Kjeldahl Nitrogen, and Oil Moisture Determination] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SAHS-20A Plus |
| Sample Capacity | 20-position carousel |
| Sample Vial Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Sample Heating Range | 40–220 °C (optional extension to 300 °C) |
| Valve & Transfer Line Heating Range | 40–220 °C (optional to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 / 2 / 5 mL) |
| RSD | < 1.0% (measured with 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Control Options | Local panel + PC software |
| Valve Configuration | High-inertness 6-port switching valve with heated connections |
| Sample Introduction Mode | Positive-pressure headspace sampling |
| Actuation | Motor-driven (no external gas required) |
| EPC Support | Optional electronic pressure control module |
| Compliance | Designed for GLP/GMP environments |
| Brand | Beifen Sanpu |
|---|---|
| Model | ZAHS-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Oven Temperature Range | 40–220 °C (optional up to 300 °C), ±0.5 °C stability |
| Valve & Transfer Line Temp Range | 40–220 °C (optional up to 300 °C), ±0.5 °C stability |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge/Clean Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (0.5/2/5 mL optional) |
| Carryover | <0.05% (tested with 100 ppm ethanol in water) |
| RSD | <1.0% (n=6, 100 ppm ethanol in water) |
| Inert Flow Path | Deactivated fused-silica and PTFE-lined tubing |
| Valve Type | High-precision 6-port 2-position valve with heated interface |
| Control Interface | USB 2.0, local 7-inch TFT LCD with Chinese UI |
| Automation Mode | Full sequence execution (equilibration, pressurization, sampling, injection, purge, vial indexing) |
| GC Synchronization | TTL/relay trigger output + software-controlled start |
| EPC Option | Electronic Pressure Control module available (optional) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GAHS-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Sample Heating Range | 40–220 °C (up to 300 °C optional), ±0.5 °C stability |
| Valve & Transfer Line Heating Range | 40–220 °C (up to 300 °C optional) |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB |
| Display | 7-inch TFT LCD with Chinese UI (English firmware available upon request) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region Category | Domestic (China) |
| Model | AHSE-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Sizes | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitation Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Oven Temperature Range | 40–220 °C (optional up to 300 °C), accuracy ±1 °C, stability <±0.5 °C |
| Valve & Transfer Line Temp Range | 40–220 °C (optional up to 300 °C), same accuracy/stability |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB, GC-trigger synchronization, external event input/output |
| Compliance | Compatible with ASTM D6866, ISO 11843, USP <467>, and GLP/GMP workflows requiring audit-trail-capable instrument control |
Show next