Empowering Scientific Discovery

Beijing Guance Jingdian Instrumentation & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCTKP-700H
PriceUSD 1,280 (FOB Beijing)
Temperature RangeAmbient to 700 °C
Heating RateProgrammable, 0.1–20 °C/min (standard)
Temperature Accuracy±1 °C (after stabilization, per ASTM E228 calibration protocol)
Displacement Range0–1 mm
Measurement Resolution±0.001 mm
Sample Dimensions(i) Ø50 mm × 60 mm cylindrical
Atmosphere ControlPressure range 0–50 kPa (gauge), compatible with inert (N₂, Ar), oxidizing (air), or reducing (5% H₂/95% N₂) environments
Power Supply220 V AC, 50 Hz, 1.7 kW
ThermocoupleType K, 0–1000 °C, Class 0.1 accuracy
Gas Flow ControlDigital mass flow controller, 0–80 L/min
Unit Dimensions700 × 810 × 1150 mm (W × D × H)
Net Weight150 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCTKP-700b
PriceUSD 1,280 (FOB Beijing)
Temperature RangeAmbient to 700 °C
Heating RateProgrammable, 0.1–10 °C/min (standard configuration)
Temperature Accuracy±1 °C (after thermal equilibrium, per ASTM E228 calibration protocol)
Displacement Range0–1 mm
Measurement Resolution±0.001 mm
Sample Dimensions(i) Ø50 mm × 60 mm cylindrical
Atmosphere ControlPressure range 0–50 kPa (gauge), compatible with inert (N₂, Ar), reducing (5% H₂/95% N₂), or vacuum conditions
Power Supply220 V AC / 50 Hz / 1.7 kW
ThermocoupleType K, 0–1000 °C, Class 0.1 accuracy
Gas Flow ControlMass flow controller, 0–80 L/min
Dimensions (W×D×H)700 mm × 810 mm × 1150 mm
Net Weight150 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelGCRPZ-1000
Temperature RangeAmbient to 1000 °C
Heating Rate0.1–10 K/min (adjustable)
Temperature Accuracy±1 °C
Sample DimensionsMax. 50 mm length × 8 mm diameter
Measurement Range±5 mm
Resolution0.1 µm
Atmosphere OptionsN₂, Ar, inert gases, vacuum (–0.1 MPa)
Sensor TypeOptical Grating Displacement Transducer
Sample Holder MaterialFused Quartz
Power Supply220 V ±10%, 50 Hz
Cooling RequirementExternal recirculating chiller (max. 100 °C bath temp, ≤2 kW heating power)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCRPZ-1000.2
PriceUSD 1,700 (FOB)
Temperature RangeAmbient to 1000 °C
Heating Rate0.1–10 K/min (programmable)
Temperature Accuracy±1 °C
Sample DimensionsMax. 50 mm length × 8 mm diameter
Measurement Range±5 mm
Resolution0.1 µm
Atmosphere OptionsN₂, Ar, inert gas, vacuum (−0.1 MPa)
Sample Holder MaterialFused quartz
Power Supply220 V ±10%, 50 Hz
Cooling RequirementExternal water chiller (max. 100 °C inlet, ≤2 kW heating power)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCTKP-700
Temperature RangeAmbient to 700 °C
Heating RateProgrammable, up to 10 °C/min (typical)
Temperature Accuracy±1 °C (after thermal equilibrium)
Displacement Range0–1 mm
Displacement Resolution±0.001 mm
Sample Dimensions(i) Ø50 mm × 60 mm
Atmosphere ControlPressure range 0–50 kPa (gauge), compatible with inert, reducing, or vacuum environments
Power Supply220 V / 50 Hz
Rated Power1.7 kW
Thermal SensorK-type thermocouple (0–1000 °C, Class 0.1 accuracy)
Gas Flow Control0–80 L/min (mass flow controller)
Instrument Dimensions700 × 810 × 1150 mm (W × D × H)
Net Weight150 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instruments
ModelGCDZY-I2
Temperature Range200 °C
Heating Rate0–200 °C/min
Temperature Accuracy±2 °C at 200 °C
Sample Chamber DimensionsØ68 mm × 120 mm (ID × height)
Tumbling Speed90 rpm
Tumbling DurationProgrammable
Steel Ball Diameter6 mm
Power Rating1 kW
Supply Voltage220 V / 50 Hz
Overall Dimensions700 × 640 × 690 mm (L×W×H)
Net Weight50 kg
ComplianceYS/T 63.11–2006, YS/T 63.12–2006
Atmosphere CapabilityAmbient air or inert gas (N₂, Ar) – configurable via external gas inlet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelZKEY-I3
PriceUSD 950 (FOB Beijing)
Rated Power3 kW
Rated Voltage220 V / 50 Hz
Max Temperature1000 °C
Operating Temperature Range0–960 °C
Temperature Control Accuracy±1 °C
Thermocouple TypeK-type, 0–1000 °C
Reaction GasHigh-Purity CO₂ (≥99.99%)
Gas Flow Sensor Range0–250 L/h, Accuracy: ±4% FS
Pressure Sensor Range0–1 MPa, Accuracy Class ≥1.5
Sample DimensionsØ50 mm ±1 mm × 60 mm ±1 mm
Equipment Dimensions1200 mm (L) × 820 mm (W) × 1500 mm (H)
Net Weight100 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
ModelGCTKP-700C
Temperature RangeAmbient to 700 °C
Heating RateProgrammable (0–10 °C/min typical)
Displacement Range0–1 mm
Displacement Resolution±0.001 mm
Sample DimensionsØ50 mm × 60 mm or ≥5 mm cross-section × ≥50 mm length
Atmosphere Control0–50 kPa (gauge), compatible with inert/N₂/air/vacuum
Power Supply220 V / 50 Hz
Rated Power1.7 kW
ThermocoupleType K (0–1000 °C, Class 0.1 accuracy)
Gas Flow Meter0–80 L/min
Dimensions (W×D×H)810 × 700 × 1150 mm
Weight150 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0