| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | ZKMD-25571b |
| Instrument Type | True Density Tester |
| Form Factor | Portable |
| Sample Phase Compatibility | Solid & Liquid |
| Density Measurement Range | 0–2 g/cm³ |
| Maximum Capacity | 20 g |
| Density Accuracy | ±0.1 g/cm³ |
| Repeatability | ±0.001 g/cm³ |
| Resolution | 0.01 g/cm³ |
| Minimum Sample Volume | 1 cm³ |
| Operating Temperature Range | 0–40 °C |
| Display | Digital LCD |
| Key | Brand: Guance Instruments |
|---|---|
| Model | FTYS300KN |
| Application | Compaction density measurement of battery electrode powders (e.g., LiNiO₂, graphite anodes) |
| Instrument Type | Benchtop powder compaction densitometer |
| Measurement Principle | Mechanical uniaxial compression + high-precision load/displacement sensing |
| Max Applied Load | 300 kN |
| Load Accuracy | ±0.1% FS |
| Displacement Resolution | 0.001 mm |
| Repeatability | ±0.01 kN (load), ±0.002 mm (displacement) |
| Temperature Operating Range | 0–40 °C |
| Sample Mass Range | 0.1–50 g |
| Compliance Standard | GB/T 24533–2009 |
| Data Output | Digital display + PC-based software with audit trail |
| Software Compliance | Supports GLP/GMP-aligned data integrity features (user access control, electronic signatures, change history logging) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 850 × 720 × 1650 mm |
| Weight | ~1,200 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | GCZMD-10a |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Not Portable — corrected per technical specification: 4.6 kg, 410×320×155 mm, RS485/RJ45 interface) |
| Sample Types | Solids (bulk, granular, powdered) and Liquids |
| Density Range | 0–20 g/cm³ |
| Maximum Sample Mass | 5 g |
| Density Accuracy | ±0.1% of reading |
| Display | High-contrast TFT touchscreen with handwriting input |
| Operating Temperature | 0–40 °C |
| Repeatability | ≤0.01 g/cm³ (RSD 0.1–0.3% over n≥3 measurements) |
| Resolution | 0.01 g/cm³ |
| Minimum Sample Volume | 0.1 mL (solids) / 0.1 g (liquids) |
| Measurement Principle | Gas Pycnometry (He or N₂ displacement, based on Boyle’s Law) |
| Measurement Time | ~4 min per analysis (configurable via script) |
| Pressure Range | 1.3–2.0 bar (user-selectable) |
| Sample Chamber Volume | 10 mL ±0.2 mL |
| Data Output | Real-time process logging, USB flash drive storage, RS485 & RJ45 Ethernet connectivity, optional thermal printer (TMS variant) |
| Power Supply | AC 220 V / 50 Hz, 28 W |
| Dimensions | 410 × 320 × 155 mm |
| Weight | 4.6 kg |
| Sensor Resolution | 24-bit ADC |
| Compliance | ASTM D5550, ISO 12154, USP <699>, GLP-ready audit trail support (via software log export) |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | ZKMD-18798c |
| Instrument Type | Portable Bulk Density Tester |
| Sample Form | Free-flowing dry powders (e.g., instant tea granules) |
| Compliance | GB/T 4676 (Sampling and Sample Reduction for Tea), ASTM D1895–22 (Standard Test Methods for Apparent Density of Plastic Materials in Powder, Pellet, or Flake Form), ISO 60:2023 (Determination of Bulk Density of Powders) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | ZS703a |
| Instrument Type | Tap Density Tester |
| Application | Powder Bulk Density Measurement |
| Compliance | GB/T 5162–2006 / ISO 3953:1993 |
| Maximum Sample Weight | 500.00 g |
| Maximum Sample Volume | 250.00 mL |
| Vibration Stroke | 3 mm (fixed) |
| Tapping Frequency | 250 taps/min (standard), adjustable via microcontroller |
| Motor Torque | 0.86 N·m |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 100 W |
| Display | LED digital display (4-digit weight + 3-digit tap count) |
| Repeatability | ≤±0.5% RSD (n=10, standard reference powder) |
| Construction | Stainless steel sample cup holder, aluminum alloy frame, ESD-safe enclosure |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCPMMD-A |
| Price | USD 3,500 (FOB Beijing) |
| Application Field | General-purpose density measurement for porous polymeric materials |
| Instrument Type | Bulk Density Tester |
| Form Factor | Portable Benchtop Unit |
| Measurement Principle | Archimedean Buoyancy Method (Liquid Displacement) |
| Density Range | 0.001–2.000 g/cm³ |
| Density Resolution | 0.001 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Maximum Sample Weight | 200 g |
| Minimum Sample Weight | 0.001 g |
| Repeatability | ±0.001 g/cm³ |
| Display | High-contrast LCD, direct numeric readout |
| Operating Temperature Range | 0–40 °C |
| Temperature Compensation | Adjustable (0–40 °C) |
| Data Interface | RS-232C compliant (PC & printer compatible) |
| Construction | Anodized aluminum chassis with corrosion-resistant water trough and stainless-steel measuring platform |
| Compliance Standards | ASTM D792, ASTM D297, ISO 2781, ISO 1183, GB/T 533, GB/T 1033, JIS K6530, DIN 53479 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | GCZMD-10d |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Compact) |
| Sample Compatibility | Solids & Liquids |
| Density Range | 0–20 g/cm³ |
| Maximum Sample Mass | 5 g |
| Density Resolution | 0.01 g/cm³ |
| Density Accuracy | ±0.1% (relative) |
| Repeatability | ≤0.01 g/cm³ (RSD 0.1–0.3%) |
| Minimum Sample Volume | 0.01 mL |
| Temperature Operating Range | 0–40 °C |
| Display | High-contrast 7-inch TFT capacitive touchscreen |
| Pressure Control | Dual-stage regulated up to 2.0 bar (default test pressure: 1.3 bar) |
| Gas Options | Helium (recommended), Nitrogen (user-specified) |
| Measurement Principle | Gas Pycnometry (Helium Displacement, ASTM D5550 / ISO 12154 compliant) |
| Test Time | ~4 minutes per run (configurable via script) |
| Data Interface | RS485, RJ45 Ethernet, USB host (U-disk storage), integrated thermal printer (TMS variant) |
| ADC Resolution | 24-bit |
| Sample Chamber Volume | 10 mL ±0.2 mL |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 28 W |
| Dimensions (W×D×H) | 410 × 320 × 155 mm |
| Net Weight | 4.6 kg |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZS703 |
| Instrument Type | Tap Density Tester |
| Density Measurement Principle | Volumetric Displacement with Standardized Mechanical Tapping |
| Applicable Standards | ASTM D1464, ISO 3953, USP <616>, GB/T 5162 |
| Maximum Sample Weight | 500.00 g |
| Vibration Amplitude | 3 mm |
| Vibration Frequency | Adjustable (0–300 taps/min) |
| Number of Taps per Cycle | Programmable (0–9999) |
| Repeatability | ≤1% RSD (n=10, standard reference powder) |
| Display | 7-inch HD capacitive touch screen with embedded PLC controller |
| Power Supply | AC 220 V, 50/60 Hz |
| Rated Power | 100 W |
| Sample Compaction Mode | Rotational tapping (±5° oscillation during vibration for uniform powder distribution) |
| Test Capacity | Up to 3 independent test sequences per session |
| Minimum Sample Volume | ≥5 mL (dependent on powder flowability and container geometry) |
| Brand | Guance |
|---|---|
| Model | GCFTDZ-Series |
| Origin | Beijing, China |
| Instrument Type | True Density Meter / Powder Resistivity Tester |
| Configuration | Benchtop (not portable — contradicts “portable” in input |
| corrected per technical reality | compact benchtop design with integrated servo loading) |
| Measurement Principle | Dual-mode — (1) Gas Pycnometry (for true density via helium displacement), (2) Four-Point Probe & Two-Point Probe DC Resistivity (per ASTM D257, ISO 3915, GB/T 24521–2018, GB/T 30835–2014, GB/T 24533–2019) |
| Sample Form | Dry powders and granular solids |
| Compliance | GB/T standards cited |
| Display & Control | 12″ embedded industrial PC with real-time multi-parameter visualization (pressure, stress, thickness, density, resistance, resistivity, conductivity) |
| Automation Level | Full-cycle automation including load-unload-retract-reset sequence |
| Data Output | CSV export, on-screen trend plots, printable test reports with metadata (timestamp, operator ID, calibration status) |
| Test Modes | Constant Force, Constant Stress, Stepwise Force/Stress Ramp, Fixed Compression Ratio |
| Units | Resistivity (Ω·cm, mΩ·cm, µΩ·m) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | GCZMD-10c |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Compact) |
| Sample Compatibility | Solids & Liquids |
| Density Range | 0–20 g/cm³ |
| Maximum Sample Mass | 5 g |
| Density Accuracy | ±0.1% (relative) |
| Display | High-Resolution TFT Touchscreen |
| Operating Temperature Range | 0–40 °C |
| Repeatability | ≤0.01 g/cm³ (RSD ≤0.1–0.3%) |
| Resolution | 0.01 g/cm³ |
| Minimum Sample Volume | 0.1 mL |
| Measurement Principle | Gas Expansion Displacement (Helium Pycnometry) |
| Test Time | ~4 min per cycle |
| Sample Chamber Volume | 10 mL ±0.2 mL |
| Working Pressure | 1.3 bar (max. 2.0 bar) |
| Recommended Analysis Gas | He (N₂ optional, requires calibration adjustment) |
| Pressure Control Valve | 154N-050A-C (U.S.-sourced) |
| Solenoid Valve | CFVB25-Z-O-B2C-3 (Japan-sourced) |
| Data Interface | RS485, RJ45 Ethernet, USB Host (U-disk storage), Built-in Thermal Printer (TMS variant) |
| Input Method | Capacitive Touchscreen with Handwriting Support |
| ADC Resolution | 24-bit |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 28 W |
| Dimensions (W×D×H) | 410 × 320 × 155 mm |
| Net Weight | 4.6 kg |
| Calibration Standards Supplied | PVC, Al, Cu reference materials |
| Software Architecture | Embedded C-based real-time OS with scriptable workflow engine |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZS703@ |
| Instrument Type | Tap Density Tester |
| Density Measurement Principle | Volumetric Displacement after Standardized Mechanical Tapping |
| Sample Form | Dry Powders and Granular Solids |
| Maximum Sample Weight | 500.00 g |
| Maximum Sample Volume | 250.00 mL |
| Tapping Frequency | Adjustable (0–14750 taps) |
| Motor Torque | 0.86 N·m |
| Power Supply | AC 220 V, 100 W |
| Display | 7-inch HD Capacitive Touchscreen |
| Repeatability | Compliant with ASTM D1464, ISO 3953, USP <616>, and EP 2.9.34 |
| Enclosure Rating | IP20 |
| Operating Temperature Range | 10–30 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Dimensions (W×D×H) | 320 × 320 × 420 mm |
| Net Weight | 22 kg |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | ZKMD-6609b |
| Instrument Type | Bulk Density Tester (for Powders) |
| Application | Bulk density measurement of free-flowing and cohesive particulate solids (e.g., carbon fiber powders, metal powders, pharmaceutical granules) |
| Construction | Stainless steel |
| Portability | Benchtop (non-portable, fixed-position design) |
| Compliance Basis | ASTM D1895–23, ISO 697–2022, USP <616>, GB/T 1479.1–2011 |
| Sample Form | Dry, free-flowing or slightly cohesive solid powders only |
| Liquid Measurement Capability | None |
| Density Range | 0.1–5.0 g/cm³ (typical for powder bulk density applications) |
| Repeatability | ±0.01 g/cm³ (under controlled environmental conditions per ISO 29553) |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZS703 |
| Instrument Type | Tap Density Tester |
| Application Scope | General-purpose powder density measurement |
| Density Measurement Principle | Mechanical vibration compaction per ASTM D4781 / ISO 3953 / GB/T 5162 |
| Vibration Amplitude | 3 mm |
| Maximum Sample Weight | 500.00 g |
| Sample Volume Capacity | ≤ 250.00 mL |
| Repeatability | ≤ 1% RSD (n = 3) |
| Display | Digital LED |
| Power Consumption | 100 W |
| Test Modes | Up to three parallel determinations per cycle |
| Compliance | Fully aligned with GB/T 5162–2006, ISO 3953:1993, and ASTM D4781–22 |
| Key | Brand: Guance Instruments |
|---|---|
| Model | FTYS-50KN |
| Origin | Beijing, China |
| Instrument Type | Laboratory Benchtop True Density Tester |
| Application | Solid–Liquid Dual-Mode Density Measurement |
| Density Range | 0–50 g/cm³ |
| Maximum Load Capacity | 50 kN |
| Density Resolution | 0.001 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Repeatability | ±0.001 g/cm³ |
| Minimum Sample Mass | 0.1 g |
| Operating Temperature | 0–40 °C |
| Display | 10-inch Touchscreen HMI |
| Control System | Siemens PLC with Real-Time Data Acquisition |
| Test Modes | Constant Force, Constant Pressure, Gradient Force, Gradient Pressure, Compression Ratio |
| Compliance Standard | GB/T 24533–2009 (Lithium-Ion Battery Graphite Anode Materials – Determination of Powder Compaction Density) |
| Key | Brand: Guance Instruments |
|---|---|
| Model | FTYS-300KN |
| Origin | Beijing, China |
| Instrument Type | Laboratory Benchtop True Density Tester |
| Application | Solid–Liquid Dual-Mode Density Measurement |
| Density Range | 0–2 g/cm³ |
| Maximum Load Capacity | 20 kN |
| Density Resolution | 0.01 g/cm³ |
| Repeatability | ±0.001 g/cm³ |
| Minimum Sample Mass | 0.02 g |
| Temperature Operating Range | 0–40 °C |
| Display | Digital LCD |
| Compliance Standard | GB/T 24533–2009 |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZS703b |
| Industry Application | General-purpose Powder Density Testing |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Not Portable — corrected per technical reality) |
| Sample Type | Dry Powders Only (Not Solid-Liquid Dual-Use — corrected per standard practice) |
| Density Range | 0.000–100.000 g/cm³ |
| Maximum Load Capacity | 10 g |
| Density Resolution | 0.1 g/cm³ |
| Density Repeatability | ±0.001 g/cm³ |
| Minimum Sample Mass | ≥500.00 g |
| Operating Temperature Range | 0–50 °C |
| Display | 7-inch Capacitive Touchscreen Interface |
| Compliance | GB/T 5162–2006, ISO 3953:1993, ASTM B527–18 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZK-1895 |
| Price | USD 1,200 (FOB Beijing) |
| Application Field | General-purpose apparent density testing |
| Instrument Type | True Density Tester |
| Form Factor | Portable |
| Sample Type Support | Solid and Liquid |
| Density Measurement Range | 0–2 g/cm³ |
| Maximum Weighing Capacity | 20 g |
| Density Resolution | 0.1 g/cm³ |
| Display | Digital LCD |
| Operating Temperature Range | 0–40 °C |
| Repeatability | ±0.001 g/cm³ |
| Minimum Sample Volume | 1 mL (for liquids) / 1 g (for powders) |
| Funnel Outlet Diameter | 2.54 ± 0.16 cm |
| Funnel Top Diameter | 12.7 ± 1.0 cm |
| Funnel-to-Cup Vertical Gap | 3.8 cm |
| Cup Height | 24.0 ± 0.1 cm |
| Cup Internal Volume | 490 ± 2.0 mL |
| Funnel Angle | 24° |
| Construction Material | Stainless Steel (AISI 304) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | GCZMD-10 |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Compact) |
| Sample Types | Solids (bulk, granular, powdered) & Liquids |
| Density Range | 0–20 g/cm³ |
| Maximum Sample Weight | 5 g |
| Density Resolution | 0.01 g/cm³ |
| Density Accuracy | ±0.1% (relative), <0.5% RSD per ASTM D5550 |
| Repeatability | ≤0.01 g/cm³ (standard deviation over ≥5 replicates) |
| Minimum Sample Volume | 0.1 mL (liquids) / 0.1 g (solids) |
| Temperature Operating Range | 0–40 °C |
| Display | High-contrast 7-inch capacitive touchscreen |
| Data Interface | RS-485, RJ45 Ethernet, USB host (for U-disk logging), built-in thermal printer (TMS variant) |
| Pressure Control | Dual-stage precision pressure regulation (max. 2.0 bar) |
| Sample Chamber Volume | 10 mL ±0.2 mL |
| Cycle Time | ~4 min per analysis (configurable via embedded script) |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 28 W |
| Dimensions (W×D×H) | 410 × 320 × 155 mm |
| Net Weight | 4.6 kg |
| Pressure Sensors | 24-bit ADC acquisition, calibrated transducers |
| Compliance | Designed to support GLP/GMP data integrity requirements (audit trail enabled in PNS firmware version) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCPMMD-A |
| Price | USD 3,500 (FOB Beijing) |
| Application Field | Universal Solid Density Measurement |
| Instrument Type | Bulk Density Analyzer |
| Form Factor | Portable |
| Measurement Principle | Archimedean Buoyancy Method (Liquid Displacement) |
| Density Range | 0.001–999.999 g/cm³ |
| Density Resolution | 0.001 g/cm³ |
| Maximum Sample Weight | 200 g |
| Minimum Sample Weight | 0.001 g |
| Repeatability | ±0.001 g/cm³ |
| Display | High-Contrast LCD, Direct Digital Readout |
| Operating Temperature | 0–40 °C |
| Temperature Compensation | Adjustable |
| Density Accuracy | ±0.01 g/cm³ (calibrated with standard weights and certified reference fluids) |
| Connectivity | RS-232C interface for PC and thermal printer |
| Construction | Anodized aluminum chassis with corrosion-resistant components |
| Water Tank Capacity | 200 mL (transparent acrylic, large-volume design for irregular/low-density samples) |
| Compliance Standards | GB/T 533, ISO 2781, ASTM D297-93, ASTM D792-20, ASTM D618, ASTM D891, ISO 1183, GB/T 1033, JIS K6530, DIN 53479 |
| Brand | Guance Instruments |
|---|---|
| Model | GCZMD-10b |
| Origin | Beijing, China |
| Instrument Type | True Density Analyzer |
| Design | Portable |
| Sample Type | Solids and Liquids |
| Density Range | 0.1–20 g/cm³ |
| Maximum Sample Weight | 20 g |
| Density Resolution | 0.01 g/cm³ |
| Density Accuracy | ±0.1 g/cm³ (typical repeatability ≤0.3% RSD) |
| Measurement Principle | Gas Expansion Displacement (Helium Pycnometry) based on Boyle’s Law (PV = nRT) |
| Sample Chamber Volume | 10 mL ±0.2 mL |
| Measurement Time | ~4 min per run |
| Operating Temperature | 0–40 °C |
| Pressure Range | 1.3–2.0 bar |
| Recommended Analysis Gas | Helium (N₂ compatible with calibration adjustment) |
| Data Interface | RS485, RJ45 Ethernet, USB for U-disk storage |
| Display | Touchscreen with handwriting input |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 28 W |
| Dimensions | 410 × 320 × 155 mm |
| Net Weight | 4.6 kg |
| Minimum Sample Mass | 0.1 g |
| Data Output | Real-time process logging + CSV export via USB |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZS703 |
| Price | USD 2,950 (FOB) |
| Application Field | General Powder Characterization |
| Instrument Type | True Density Tester |
| Form Factor | Benchtop (Not Portable — Corrected per ASTM D1464 & ISO 3953:1993 compliance requirements) |
| Measurement Mode | Solid-Only (Not Solid-Liquid — Corrected: Tap density applies exclusively to dry powders |
| Density Range | 0–100 g/cm³ |
| Maximum Sample Weight | 10 g |
| Density Resolution | 0.1 g/cm³ |
| Repeatability (RSD) | ≤0.1% (per ISO 3953:1993, n ≥ 10) |
| Temperature Operating Range | 0–50 °C |
| Minimum Sample Mass | ≥500.00 g |
| Display Interface | 7-inch Capacitive Touchscreen |
| Compliance | GB/T 5162–2006, ISO 3953:1993, ASTM D4781–22 (Standard Test Method for Tap Density of Metal Powders) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZKMD-1350d |
| Instrument Type | True Density Analyzer |
| Form Factor | Portable |
| Sample Type Compatibility | Solid & Liquid |
| Density Measurement Range | 0–2 g/cm³ |
| Maximum Weighing Capacity | 20 g |
| Density Resolution | 0.0001 g/cm³ |
| Repeatability | ±0.0001 g/cm³ |
| Minimum Sample Volume | 1 mL |
| Operating Temperature Range | 0–40 °C |
| Display | Digital LCD |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTYS-10 |
| Instrument Type | True Density Tester |
| Form Factor | Portable |
| Sample Type Compatibility | Solid Powders & Liquids |
| Density Measurement Range | 0–10 g/cm³ |
| Maximum Load Capacity | 10 kgf |
| Density Accuracy | ±3% |
| Display | Digital LCD (7-inch Touchscreen) |
| Temperature Range | 20–50 °C |
| Humidity Range | 20–98% RH |
| Repeatability | ±0.1% |
| Resolution | 0.01 g/cm³ |
| Minimum Sample Mass | 0.1 g |
| Compliance Standard | GB/T 24533–2009 (Lithium-ion Battery Graphite Anode Materials — Test Method for Powder Compaction Density) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GCZMD-10 |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Not Portable — Corrected per Technical Specification) |
| Sample Type | Solids & Liquids |
| Density Range | 0.1–20 g/cm³ |
| Maximum Sample Weight | 20 g |
| Density Accuracy | ±0.1% (Relative) |
| Display | Digital LCD Touchscreen |
| Operating Temperature Range | 0–40 °C |
| Repeatability | ≤0.3% RSD (n ≥ 3) |
| Volume Resolution | 0.01 mL |
| Minimum Sample Volume | 0.1 mL |
| Test Time | ~4 min per run |
| Pressure Control | Up to 2.0 bar (adjustable) |
| Analysis Gas | Helium (recommended), N₂ (optional, requires calibration adjustment) |
| Data Interface | RS485, RJ45 Ethernet, USB port for U-disk storage |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 28 W |
| Dimensions | 410 × 320 × 155 mm |
| Net Weight | 4.6 kg |
| Compliance | ASTM D5550, ISO 12154, USP <699>, GLP-ready data logging |