| Brand | Guance |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NDH-AI2 |
| Instrument Type | Electronic Universal Testing Machine |
| Rated Power | 10 kVA |
| Test Voltage | 220 V / 50 Hz |
| Arc Current | 33 ± 5 A (adjustable) |
| Power Factor | cosφ = 0.5 ± 0.05 (adjustable) |
| Arc Frequency | 40 cycles/min (adjustable) |
| Arc Speed | 254 ± 25 mm/s |
| Electrode Geometry | Static electrode — φ3.2–3.5 mm, 30° chisel tip |
| Electrode Angle | 45° to horizontal |
| Specimen Dimensions | 130 mm × 13 mm × (2–12) mm |
| Max Arc Cycles | 200 (programmable) |
| Overall Dimensions | 1250 mm (W) × 800 mm (D) × 1750 mm (H) |
| Control System | Siemens PLC |
| Human-Machine Interface | 10-inch industrial touchscreen |
| Safety Features | Interlocked sliding door, overcurrent protection, position-limit sensing, audible alarm, tower status lamp (green/red/yellow), integrated exhaust fan with LED illumination |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NLD-AII2 |
| Instrument Type | Electromechanical Universal Testing System |
| Input Voltage | AC 220 V |
| Output Voltage Range | AC 0–50 kV / DC −50–0 kV (adjustable) |
| Power Rating | 50 kVA |
| Voltage Accuracy | < ±2% |
| Current Output Capacity | ≥1 A (HV side) |
| Current Measurement Accuracy | < ±1% |
| Test Duration | Up to 1000 h continuous |
| Fog Chamber Volume | 4 m³ (L×W×H = 2000 × 1200 × 1700 mm) |
| 雾化颗粒Size | 5–10 µm |
| Salt Spray Rate | (0.4 ± 0.1) L/m³·h |
| Airflow Velocity at Specimen | 3 m/s |
| Specimen Spacing | ≥400 mm from ceiling and walls |
| Specimen Capacity | 1 horizontal + 1 vertical mounting position |
| Safety Interlock | Door-activated HV cutoff and automatic zeroing |
| Control System | Embedded industrial computer with real-time data logging |
| Dimensions (L×W×H) | 3400 × 1300 × 1800 mm |
| Weight | 300 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NLD-AII.2 |
| Instrument Type | Electromechanical Universal Testing System |
| Input Voltage | AC 220 V |
| Output Voltage Range | AC 0–50 kV / DC −50–0 kV (adjustable) |
| Electrical Capacity | 50 kVA |
| Voltage Accuracy | < ±2% |
| High-Voltage Output Current | ≥1 A |
| Current Measurement Accuracy | < ±1% |
| Spray Velocity at Specimen | 3 m/s |
| Salt Fog Generation Rate | (0.4 ± 0.1) L/m³·h |
| 雾室 Volume | 4 m³ (L×W×H = 2000 × 1200 × 1700 mm) |
| 雾化 Particle Size | 5–10 µm |
| Specimen Mounting | 1 horizontal + 1 vertical |
| Minimum Clearance | ≥400 mm from ceiling and walls |
| Test Duration | 1000 h (continuous) |
| 雾化 Method | Ultrasonic Atomization |
| Salt Solution | NaCl + deionized water |
| Safety Interlock | Door-activated high-voltage cutoff & auto-zero reset |
| Control System | Embedded industrial computer |
| Dimensions (L×W×H) | 3400 × 1300 × 1800 mm |
| Weight | 300 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NLD-AII |
| Instrument Type | Electronic High-Voltage Tracking Test System |
| Input Voltage | AC 220 V |
| Output Voltage Range | AC 0–50 kV / DC −50 to 0 kV (adjustable) |
| Electrical Capacity | 50 kVA |
| Voltage Accuracy | < ±2% |
| Current Output | ≥1 A (HV side) |
| Current Measurement Accuracy | < ±1% |
| Test Duration | 1000 h (continuous) |
| Fog Chamber Volume | 4 m³ (L×W×H = 2000 × 1200 × 1700 mm) |
| Nozzle-to-Specimen Distance | >400 mm (top & lateral) |
| Specimen Configuration | 1 horizontal + 1 vertical insulator |
| 雾化方� | �: Ultrasonic nebulization |
| 雾化速度 | 3 m/s |
| Salt Solution | NaCl + deionized water |
| Fog Density | (0.4 ± 0.1) L/m³·h |
| Particle Size Distribution | 5–10 µm |
| Safety Interlock | Door-activated HV cutoff & auto-zero |
| Control System | Embedded industrial computer |
| Dimensions (L×W×H) | 3400 × 1300 × 1800 mm |
| Weight | 300 kg |
| Brand | GuanCe Instruments |
|---|---|
| Model | NLD-BI3 |
| Type | Electronic Universal Testing Machine |
| Voltage Range | 100–600 V AC (48–60 Hz) |
| Electrode Material | 99% Pure Platinum (tips), Copper (holders) |
| Electrode Dimensions | (2.0 ± 0.1) mm × (5.0 ± 0.1) mm × (40 ± 5) mm |
| Electrode Tip Geometry | 12 mm length, 30° ± 2° bevel |
| Electrode Spacing | 4.00 ± 0.01 mm, 60° ± 5° included angle |
| Electrode Force | 1.00 ± 0.01 N |
| Test Solution Resistivity | A-solution: 3.95 ± 0.05 Ω·m (0.1% NH₄Cl) |
| B-solution | 1.98 ± 0.05 Ω·m |
| Droplet Height | 35 ± 5 mm (adjustable) |
| Droplet Interval | 30.00 ± 0.01 s (digital preset, 50-droplet time: 24.5 ± 2 min) |
| Droplet Count Range | 1–9999 (digital display & preset) |
| Airflow Velocity in Test Chamber | 0.2 m/s |
| Short-Circuit Current Threshold | 0.50 A ± 10%, sustained for 2.00 ± 0.2 s |
| Voltage Drop Limit | ≤8% at 1.0 ± 0.1 A load |
| Power Supply | 220 V, 0.6 kVA, 50–60 Hz |
| Ambient Operating Conditions | 0–40 °C, RH ≤80%, non-corrosive, low-vibration environment |
| Combustion Chamber Volume | >0.5 m³ (approx. 900 × 590 × 1050 mm), black matte background, illuminance ≤20 lux |
| Exhaust Port Diameter | Ø100 mm |
| Touchscreen Interface | 7-inch color HMI with PLC control, on-screen real-time monitoring of voltage, current, droplet count, chamber status, and pass/fail logic |
| Brand | Guance |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | PMQS-I2 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Power Supply | 220 V / 50 Hz |
| Vertical Travel Range | 0–800 mm |
| Optical Sensor Accuracy | ±1 mm |
| Optical Sensor Range | 10–1000 mm |
| Temperature Probe Range | 0–500 °C (Accuracy: ±0.5% FS) |
| Pressure Sensor Range (Optional) | 0–500 N |
| Sample Cup ID | 100 mm |
| Sample Cup Height | 200 mm |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMPL-2000A1 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Maximum Load Capacity | 1000 N |
| Reciprocating Compression Frequency | 10–100 cycles/min (Standard Compliance: 70 ± 5 cycles/min per ISO 3385) |
| Max. Cycles | >100,000 |
| Platen Diameter | φ250 mm ± 1 mm, Bottom Edge Radius: R25 mm ± 1 mm |
| Specimen Support Table | 500 mm × 500 mm square, 10 mm thick, with 6.35 mm diameter holes on 20 mm centers |
| Specimen Dimensions | 500 mm × 500 mm × (50 ± 2) mm |
| Force Display | Real-time peak load readout |
| Control Interface | 7-inch color touchscreen HMI |
| Actuation | Servo motor-driven |
| Test Modes | Constant-force loading or constant-thickness compression (expressed as % deformation) |
| End-of-Test Action | Audible alarm + automatic platen return to zero position |
| Specimen Positioning | Adjustable mechanical alignment fixtures ensuring positional stability over extended cycling |
| Power Supply | 220 V AC / 50 Hz |
| Footprint | 800 mm (L) × 500 mm (W) × 1200 mm (H) |
| Net Weight | 100 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | YHT-RC100a |
| Instrument Type | Electromechanical Universal Testing System |
| Compliance | AS4373D, GJB773A, ASD-STAN PREN6059-502 |
| Control System | Siemens S7-1200 PLC + MCGS 10-inch Capacitive Touch HMI |
| Input Power | AC 220 V ±10%, 50 Hz, 2 kW |
| Test Voltage Range | Adjustable up to 10 kV (per standard requirements) |
| Current Measurement Accuracy | ±1% of reading, resolution 0.01 A |
| Voltage Measurement Accuracy | ±1% of reading, resolution 0.1 V |
| Arc Exposure Duration | 1–99,999,999 s (programmable) |
| Droplet Delivery Rate | 100 ±10 mg/min (8–10 drops/min) via Lead Fluid BV-100 peristaltic pump |
| Blade Stroke Adjustment | 1–10 cm (standard 3.81 ±0.3 cm), bidirectional, servo-driven |
| Blade Reciprocating Speed | 0.5 ±0.05 cycles per second |
| Applied Load on Blade | 250 ±25 g |
| Environmental Operating Range | –30 to +40 °C, ≤85% RH, 80–120 kPa, ≤1000 m altitude |
| Grounding Resistance | <1 Ω |
| Dimensions (L×W×H) | 1400 × 830 × 1500 mm |
| Weight | 300 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMTQ-A |
| Instrument Type | Electronic Universal Testing Machine |
| Vacuum Pump Speed | 1.3 m³/h (4.8 L/s) |
| Ultimate Vacuum | 5 × 10² Pa |
| Flow Sensor Range | 0–50 L/min |
| Differential Pressure Sensors | 0–400 Pa & 0–100 Pa |
| Test Chamber Dimensions | 100 mm × 100 mm × 104 mm |
| Specimen Size | 102 mm × 102 mm × 0–100 mm |
| Air Permeability Range | 0–999.9 × 10⁻¹⁰/m² |
| Temperature Sensor Range | −40 °C to +80 °C |
| Chamber Material | 4 mm 304 brushed stainless steel |
| Safety Protections | Over-temperature, over-pressure, over-flow, and overload protection |
| Dimensions (L×W×H) | 800 mm × 630 mm × 700 mm |
| Weight | 85 kg |
| Power Rating | 1 kW |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | NLD-C |
| Instrument Category | Electronic Universal Testing Machine |
| Rated Price | USD 1,950 (approx.) |
| Input Voltage | AC 220 V |
| Output Voltage Range | AC 0–5 kV |
| Power Rating | 5 kVA |
| Voltage Accuracy | < ±2% |
| High-Voltage Output Current | > 1 A |
| Short-Circuit Current at ≥250 mA | Voltage Drop < 5% |
| Current Measurement Accuracy | < ±1% |
| Spray Nozzle Distance to Specimen | ≥500 mm |
| Spray Angle Relative to Specimen Axis | 45° |
| Spray Velocity at Specimen Surface | 3 m/s |
| Spray Rate | 0.5 mm/min |
| Standard Spray Cycle | 10 s spray / 20 s pause |
| Specimen Length | ≥150 mm |
| Specimen Preparation | Exposed conductor segment (20 mm), grounding wire wrap (1 mm bare copper, 2–3 turns at 100 mm from cut edge) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NLD-AI5 |
| Price | USD 1,950 (approx.) |
| Instrument Type | Electronic Universal Testing Machine |
| Standards Compliance | GB/T 6553–2003, IEC 60587:1984 |
| Test Method Modes | Constant Voltage Method, Stepwise Voltage Method |
| Voltage Supply | AC (48–62 Hz) and DC |
| Sample Channels | 5 independent parallel test circuits |
| Control System | Siemens PLC with optical isolation for voltage/current acquisition |
| Human Interface | 10-inch industrial touchscreen HMI |
| Leakage Current Alarm Range | 0–100 mA (user-configurable per channel) |
| Dropping System | Precision peristaltic pump with real-time flow display and on-screen adjustment |
| Voltage Regulation | Autotransformer + oil-immersed step-up transformer for low-voltage-drop stability |
| Safety Interlock | Door-open automatic high-voltage cutoff |
| Exhaust System | Dedicated fume extraction ducted outdoors |
| Illumination | Integrated LED internal lighting |
| Data Calibration | On-device voltage and current recalibration function |
| Test Duration Setting | Programmable (minutes) |
| Voltage Ramp & Reset | Auto-ramp to set voltage |
| Liquid Management | Separated fresh/drain reservoirs for contamination control |
| Real-time Monitoring | Per-channel voltage, instantaneous leakage current, peak leakage current, elapsed time |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCWDS-5K |
| Instrument Type | Electromechanical Universal Testing Machine |
| Maximum Test Load | 5 kN |
| Accuracy Class | Class 0.5 |
| Frame Type | Portal-Style, Floor-Standing |
| Load Cell Accuracy | ±1% of reading (2–100% FS) |
| Force Resolution | 1/300,000 of full scale |
| Displacement Resolution | 0.01 mm |
| Crosshead Speed Range | 0.05–850 mm/min |
| Speed Accuracy | ±1% of set value |
| Effective Tensile Stroke | 650 mm |
| Effective Test Width | 600 mm |
| Dimensions (W×D×H) | 695 × 580 × 2400 mm |
| Weight | 300 kg |
| Power Supply | 220 V, 50 Hz, 1 kW |
| Control System | SmartTest™ Digital Controller with Windows-Based Software |
| Compliance Standards | GB/T 228.1, ISO 6892-1, ASTM E4, ASTM E8, ASTM D638, ASTM D790, JIS Z2241, DIN 50125 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NLD-C2 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Input Voltage | AC 220 V |
| Output Voltage Range | AC 0–5 kV |
| Power Rating | 5 kVA |
| Voltage Accuracy | < 2% |
| High-Side Output Current | > 1 A |
| Current Measurement Accuracy | < 1% |
| Spray Velocity at Specimen | 3 m/s |
| Spray Rate | 0.5 mm/min |
| Standard Spray Cycle | 10 s spray / 20 s pause |
| Nozzle-to-Specimen Distance | ≥ 500 mm |
| Nozzle Angle Relative to Specimen Axis | 45° |
| Spray Range | > 1 m |
| Specimen Length | ≥ 150 mm |
| Compliance | GB/T 3048.7–2007 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | NDH-AI3 |
| Quotation | USD 2,100 (FOB Beijing) |
| Instrument Type | Electromechanical Universal Testing Machine |
| Compliance Standards | IEC 60950-1:2001, BS EN 60950-1:2001, BS 7002:2000, GB 4943-2001, UL 746A, IEC 60947-1:1999, GB/T 14048.1-2000, IEC 730-1:1993, GB 14536.1-1998 |
| Control System | Siemens S7-1200 PLC |
| Human-Machine Interface | 10-inch resistive touchscreen with dynamic password login |
| Electrode Configuration | Static electrode — Cu, Ø3.2–3.5 mm, 30° chisel tip |
| Electrode Angle | 45° to horizontal plane |
| Test Voltage | 220 V AC / 50 Hz |
| Arc Current | 33 ± 5 A (adjustable) |
| Power Factor | cosφ = 0.5 ± 0.05 (adjustable) |
| Arcing Speed | 254 ± 25 mm/s |
| Arcing Frequency | 40 cycles/min (adjustable) |
| Arcing Cycles | Up to 200 (user-defined) |
| Specimen Dimensions | 130 mm × 13 mm × (2–12) mm |
| External Dimensions | 1250 mm (W) × 800 mm (D) × 1750 mm (H) |
| Rated Power | 10 kVA |
| Safety Features | Interlocked sliding door with limit switch, overload protection, audible alarm, tri-color tower lamp (green/amber/red), integrated exhaust fan with LED task lighting |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NLD-AI7 |
| Instrument Type | Electronic Universal Testing Machine |
| Voltage Output | AC 100–8000 V / DC 100–8400 V |
| Electrical Capacity | 7 kVA |
| Input Power | AC 220 V, 50 Hz |
| Electrode Spacing | (50 ± 0.5) mm |
| Electrode Material | 304 Stainless Steel |
| Electrode Mounting | Dual independent high-insulation, high-strength composite支架 |
| Test Specimens | Up to 5 simultaneous samples |
| Test Methods | Constant Voltage Method & Stepwise Voltage Method |
| Drip Rate Control | Programmable per-channel via precision peristaltic pump |
| Leakage Current Alarm Range | 0–100 mA (user-configurable per channel) |
| Voltage Drop | ≤5% under load |
| Safety Interlock | Automatic HV cutoff upon door opening |
| Data Calibration | Onboard voltage/current recalibration function |
| Ventilation System | Dedicated exhaust duct with external venting capability |
| Illumination | Integrated LED interior lighting |
| Voltage Stabilization | Oil-immersed transformer + autotransformer regulation |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NDH-AI4 |
| Instrument Type | Electronic Universal Testing Machine |
| Rated Power | 10 kVA |
| Test Voltage | 220 V / 50 Hz |
| Arc Current | 33 ± 5 A (adjustable) |
| Power Factor | cosφ = 0.5 ± 0.05 (adjustable) |
| Arc Frequency | 40 cycles/min (adjustable) |
| Arc Speed | 254 ± 25 mm/s |
| Electrode Geometry | Static electrode — φ3.2–3.5 mm, 30° chisel tip |
| Electrode Angle | 45° to horizontal plane |
| Specimen Dimensions | 130 mm × 13 mm × (2–12) mm |
| Arc Cycles | Up to 200 (programmable) |
| Enclosure Dimensions | 1250 mm (W) × 800 mm (D) × 1750 mm (H) |
| Human-Machine Interface | 10-inch capacitive touchscreen |
| Control System | Siemens S7-1200 PLC |
| Safety Features | Interlocked sliding door, mechanical limit switches, overload protection, audible alarm, tower status lamp (green/red/yellow), integrated exhaust fan with LED illumination |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Type | Electronic Universal Testing Machine |
| Model | NLD-BI6 |
| Voltage Range | 100–600 V AC (48–60 Hz) |
| Electrode Material | 99% Pure Platinum (tips), Copper (electrode rods) |
| Electrode Dimensions | (2.0 ± 0.1) mm × (5.0 ± 0.1) mm × (40 ± 5) mm |
| Electrode Tip Geometry | 12 mm length, 30° ± 2° bevel |
| Electrode Spacing | 4.00 ± 0.01 mm, included angle 60° ± 5° |
| Electrode Force | 1.00 ± 0.01 N |
| Test Solution Resistivity | Solution A: 3.95 ± 0.05 Ω·m (0.1% NH₄Cl) |
| Solution B | 1.98 ± 0.05 Ω·m |
| Droplet Height | 35 ± 5 mm (adjustable) |
| Droplet Interval | 30.00 ± 0.01 s (digital presettable) |
| 50-droplet duration | 24.5 ± 2 min |
| Droplet Count Range | 1–9999 (digital display & preset) |
| Airflow Velocity | 0.2 m/s (per IEC 60695-11-5) |
| Short-Circuit Current Threshold | 0.50 A ± 10%, sustained for 2.00 ± 0.2 s |
| Voltage Drop Limit | ≤8% at 1.0 A ± 0.1 A |
| Power Supply | 220 V, 0.6 kVA, 50–60 Hz |
| Test Chamber Volume | >0.5 m³ (L×W×H ≈ 900 × 590 × 1050 mm) |
| Operating Environment | 0–40 °C, RH ≤80%, non-corrosive, low-vibration |
| Compliance | GB/T 4207–2003, IEC 60695-11-5, IEC 60695-11-10 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NLD-AII |
| Instrument Type | Electromechanical Universal Testing Machine |
| Input Voltage | AC 220 V |
| Output Voltage Range | AC 0–50 kV / DC −50–0 kV (adjustable) |
| Power Rating | 50 kVA |
| Voltage Accuracy | < ±2% |
| High-Voltage Output Current | ≥1 A |
| Current Measurement Accuracy | < ±1% |
| Spray Velocity at Specimen | 3 m/s |
| Salt Fog Generation | Ultrasonic atomizer |
| Fog Volume Concentration | (0.4 ± 0.1) L/m³·h |
| Fog Particle Size | 5–10 µm |
| Fog Chamber Volume | 4 m³ (2000 × 1200 × 1700 mm) |
| Specimen Mounting | 1 horizontal + 1 vertical position |
| Minimum Clearance | ≥400 mm from chamber ceiling and walls |
| Test Duration | Up to 1000 h continuous |
| Safety Interlock | Door-activated high-voltage cutoff and automatic voltage zeroing |
| Control System | Embedded industrial computer |
| Dimensions (L×W×H) | 3400 × 1300 × 1800 mm |
| Weight | 300 kg |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NDH-B6 |
| Price | USD 2,350 (approx.) |
| Instrument Type | Electromechanical Universal Testing Machine |
| Standards Compliance | GB/T 1411-2002, IEC 61621:1997, ASTM D495, IEC 149, UL 746A |
| Rated Test Voltage | 12.5 kV |
| Voltage Accuracy | ±1% |
| Current Range | 10–40 mA (selectable steps) |
| Current Control Accuracy | ±3% |
| Current Measurement Accuracy | ±1.5% |
| Arc On/Off Timing Error | < ±1 ms |
| Electrode Force | 0.5 ± 0.05 N |
| Electrode Material | Tungsten Rod |
| Electrode Spacing | 6.35 ± 0.1 mm (IEC), 6.0 ± 0.1 mm (ASTM) |
| Input Power | 220 V AC, 50 Hz |
| Transformer Capacity | 3 kVA |
| Output Voltage Range | 0–17.5 kV AC |
| Operating Environment | 23 ± 2 °C, 50 ± 5 % RH |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NLD-BI4 |
| Instrument Type | Electronic Universal Testing Machine |
| Test Voltage Range | 100–600 V AC (48–60 Hz) |
| Electrode Material | Platinum (99% purity) / Copper electrode holder |
| Electrode Dimensions | (2.0 ± 0.1) mm × (5.0 ± 0.1) mm × (40 ± 5) mm |
| Tip | 12 mm long, 30° ± 2° bevel |
| Electrode Spacing | 4.00 ± 0.01 mm, included angle 60° ± 5° |
| Electrode Force | 1.00 ± 0.01 N |
| Test Solution Resistivity | Solution A: 0.1% NH₄Cl, 3.95 ± 0.05 Ω·m |
| Solution B | 1.98 ± 0.05 Ω·m |
| Droplet Height | 35 ± 5 mm (adjustable) |
| Droplet Interval | 30.00 ± 0.01 s (digital display, presettable) |
| 50-droplet duration | 24.5 ± 2 min |
| Droplet Count Range | 1–9999 (digital, presettable) |
| Airflow Velocity | 0.2 m/s (per IEC 60695-11-5) |
| Short-Circuit Current Threshold | 0.50 A ± 10%, hold time 2.00 s ± 10% |
| Voltage Drop Limit | ≤8% at 1.0 A ± 0.1 A |
| Power Supply | 220 V, 0.6 kVA, 50–60 Hz |
| Ambient Conditions | 0–40 °C, RH ≤80%, non-corrosive, low-vibration environment |
| Combustion Chamber Volume | >0.5 m³ (approx. 900 × 590 × 1050 mm), black background, illuminance ≤20 lux |
| Exhaust Port Diameter | Ø100 mm |
| Overall Dimensions (W×D×H) | 1160 × 600 × 1310 mm (incl. leveling feet) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | YHT-RC100.3 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Power Input | AC 220 V ±10%, 50 Hz ±0.5 Hz, 2 kW |
| Test Voltage Accuracy | ±1% (0.1 V resolution) |
| Test Current Accuracy | ±1% (0.01 A resolution) |
| Arc Exposure Duration | 1–99,999,999 s (programmable) |
| Dry/Wet Mode Switching | Yes |
| Electrode Travel Range | 1–10 cm (standard 3.81 ±0.3 cm) |
| Electrode Stroke Speed | 0.5 ±0.05 cycles per second (full reciprocation) |
| Electrode Load Mass | 250 ±25 g |
| Dropping Rate (Wet Mode) | 100 ±10 mg/min (8–10 drops/min, via Lead Fluid peristaltic pump) |
| Control System | Siemens original PLC (S7 series) |
| HMI | Kunlun Tongtai 10-inch capacitive touchscreen |
| Compliance Standards | AS4373D, GJB773A, ASD-STAN PRF-6059-502, EN 6059-502 (PrEN) |
| Operating Altitude | ≤1000 m |
| Ambient Temperature | −30 °C to +40 °C |
| Relative Humidity | ≤85 % RH |
| Grounding Resistance | <1 Ω |
| Dimensions (L×W×H) | 1400 × 830 × 1500 mm |
| Weight | 300 kg |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCWDS-100KN |
| Instrument Type | Electromechanical Universal Testing Machine |
| Max. Test Load | 100 kN |
| Accuracy Class | 0.5 |
| Force Measurement Range | 0.2–100% F.S. |
| Force Resolution | 1/300,000 (full-scale, unsegmented) |
| Displacement Rate Range | 0.1–500 mm/min |
| Tensile/Compressive Stroke | 650 mm |
| Test Width | 400 mm |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 1.6 kW |
| Operating Environment | 10–40 °C, 20–80% RH |
| Dimensions (W×D×H) | ≈800×650×2000 mm |
| Weight | ≈320 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YSRB-300 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Heating Method | Air-bath |
| Test Channels | 3 |
| Temperature Range | Ambient to 300 °C |
| Temperature Stability | ±2 °C |
| Heating Rate | 50±3 °C/h or 10±2 °C/12 min |
| Temperature Resolution | 0.1 °C |
| Deformation Resolution | 0.002 mm |
| Specimen Dimensions | 50×50×50 mm or 40×40×20 mm |
| Compression Platen Size | 50×50 mm (×3) |
| Recommended Load Range | 0–1 MPa |
| Heating Chamber Volume | 350×400×400 mm |
| Lever Compression Ratio | 1:32 |
| Loading Configuration | Lever-based dead-weight compression (3 stations), direct dead-weight bending (3 stations) |
| Standard Compliance | GB/T 20672–2006, DIN 53424 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | ZKDC-01 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Compliance Standards | MT/T 1051–2007, UL 1642–2005, UL 2054–2005, SJ/T 11169–1998, YD 1268–2003, SJ/T 11170–1998, GB/T 8897.4–2002 |