Empowering Scientific Discovery

Beijing Guance Jingdian Instrumentation & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMLQ-500C
PriceUSD 1,420 (FOB Beijing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelBETA202A4
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Volumetric Gas Adsorption (BET, BJH, DFT, NLDFT, t-plot, αs-method)
Number of Analysis Stations10
Specific Surface Area Range0.0005 m²/g (Kr) to unlimited
Pore Size Range0.35 nm – 500 nm
Pressure Range10⁻⁸ Torr – 1000 Torr
Relative Pressure (P/P₀) ResolutionDown to 10⁻⁷
Repeatability< ±1% (for N₂ at 77 K)
Detection Limit for Pore Volume0.0001 cm³/g
Vacuum System Base Pressure≤1×10⁻⁸ Torr (with optional turbomolecular pump)
Thermal ManagementIntegrated liquid nitrogen isothermal jacket with 70-hour autonomy
Gas CompatibilityN₂, Ar, Kr, CO₂, NH₃, H₂, CO, O₂, CH₄, C₄H₁₀ (non-corrosive only)
Data Acquisition24-bit ADC, dual-capacitance manometers (0–10 Torr & 0–1000 Torr), dedicated P₀ reference sensor
ConnectivityUSB 2.0 or Ethernet (TCP/IP), remote control & multi-instrument management supported
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelBETA201A
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Volumetric Method (BET & BJH) with Dynamic Preconditioning Capability
Analysis Stations1
Surface Area Range0.0001 m²/g (Kr adsorption) to unlimited
Pressure Range0–133 kPa (0–1000 Torr)
P/P₀ ResolutionUp to 0.9995
Vacuum Level≤1×10⁻⁸ Torr (with optional molecular pump)
Repeatability<±1% (standard N₂ adsorption on certified reference materials)
Adsorption GasesN₂, Ar, Kr, CO₂, NH₃, H₂, CO, O₂, CH₄, C₄H₁₀ (non-corrosive only)
Analysis Time~25 min per surface area measurement
Cryogen Capacity70 h continuous operation with standard 3.5 L liquid nitrogen Dewar
Isothermal JacketIntegrated liquid nitrogen isothermal sleeve for thermal stability
Data Acquisition24-bit ADC
ComplianceDesigned for GLP-compliant labs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instruments
OriginBeijing, China
ModelGEST-20042F
ComplianceGB/T 20042.6–2011, GB/T 20042.7–2014
Measurement ModesThrough-plane (2-probe) & In-plane (4-probe)
Electrode Diameter50 mm gold-plated
Control Interface10-inch industrial touchscreen HMI
Loading ActuationServo-motor-driven precision force application
Data OutputReal-time pressure, compressive strain, voltage, current, resistance, resistivity (mΩ·cm, Ω·cm, kΩ·cm), conductivity (S/cm, S/m)
Test ProtocolsConstant-force, constant-pressure, stepwise gradient (force/pressure/strain), compression-ratio control
Data ExportCSV via USB
Auto-resetYes
ReportingOn-screen preview + thermal printout
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeDomestic Distributor
Product CategoryDomestic
ModelPMQS-I.3
PriceUSD 1,400 (approx.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance
ModelGEST-20042G
OriginBeijing, China
ComplianceGB/T 20042.6–2011, GB/T 20042.7–2014
Measurement ModesVertical (2-probe) & Horizontal (4-probe) Resistivity
Force ControlServo-driven Loading System
Electrodes50 mm Gold-Plated
Display10-inch Touchscreen HMI
Data OutputReal-time Parameter Logging, Exportable CSV, On-Screen Print
Test ModesConstant Force, Constant Pressure, Gradient Force, Gradient Pressure, Compression Ratio
UnitsΩ·cm, Ω·m, S/m, mS/cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMTQ-A.2
PriceUSD 2,800 (FOB Beijing)
ComplianceISO 4638:1984, GB/T 10655, ASTM D3574-2005, AQ 1088-2011
Vacuum Pump1.3 m³/h (4.8 L/s), Ultimate Vacuum: 5 × 10² Pa
Flow Sensor Range0–50 L/min
Differential Pressure SensorsDual-range — 0–400 Pa & 0–100 Pa
Test Chamber Dimensions100 mm × 100 mm × 104 mm (L×W×D)
Specimen Size102 mm × 102 mm × (0–100) mm
Air Permeability Range0–999.9 × 10⁻¹⁰ m²
Temperature Sensor−40 °C to +80 °C
Chamber Material4 mm 304 brushed stainless steel
Safety ProtectionsOver-temperature, over-pressure, over-flow, and motor overload protection
Unit Dimensions800 mm × 630 mm × 700 mm (L×W×H)
Weight85 kg
Power Supply1 kW, 220 V AC, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelBETA201A1
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Volumetric Method (with optional dynamic mode support)
Number of Analysis Stations4
Specific Surface Area Range0.0001 m²/g (using Kr adsorption) to unlimited
Pressure Range0–133 kPa (0–1000 Torr)
Theoretical BasisStatic Volumetric Gas Adsorption
Repeatability±0.001 m²/g (absolute) or <±1% relative
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeGeneral Distributor
Region of OriginDomestic (China)
ModelGCPMQS-I
PriceUSD 1,280 (FOB Beijing)
Power Supply220 V / 50 Hz
Vertical Travel Range0–800 mm
Optical Sensor Accuracy±1 mm
Optical Sensor Range10–1000 mm
Temperature Probe Range0–500 °C, Accuracy: ±0.5% FS
Pressure Sensor Capacity500 N (optional)
Sample Cup ID100 mm
Sample Cup Height200 mm
Polarization ModuleOptional
High-Speed Imaging ModuleOptional
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGEST-20042I
PriceUSD 1,550 (FOB Beijing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGEST-20042
PriceUSD 1,560 (FOB Beijing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelBETA201A.4
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Volumetric Method (with optional dynamic mode support)
Analysis Stations1
Surface Area Range0.0001 m²/g (using Kr adsorption) to unlimited
Pressure Range0–133 kPa
Repeatability< ±1%
Operating Ambient TemperatureUp to 400 °C
Temperature Control Accuracy±0.1%
Vacuum System Base Pressure≤1×10⁻⁸ Pa (≤7.5×10⁻¹¹ Torr)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginDomestic (China)
ModelPMQS-I.5
PriceUSD 2,100 (approx.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional CategoryDomestic (PRC)
ModelGCJPD-I
PriceUSD 1,850 (excl. tax & shipping)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGEST-20042D
PriceUSD 1,540 (FOB Beijing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelBETA201A
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Method (Gas Adsorption)
Analysis Stations1
Surface Area Range0.0001 m²/g (using Kr) to unlimited
Pressure Range0–133 kPa
P/P₀ Resolutionup to 10⁻⁷
Vacuum Level≤1×10⁻⁸ Torr (with optional turbomolecular pump)
Detection Limit for Pore Volume0.0001 cm³/g (N₂)
Pore Diameter Range0.35 nm – 500 nm
Repeatability<±1%
Analysis Time~25 min (BET), ~3.5 h (full pore distribution)
Gas CompatibilityN₂, Ar, Kr, CO₂, NH₃, H₂, CO, O₂, CH₄, C₄H₁₀ (non-corrosive only)
InterfaceUSB or Ethernet (RJ45)
Data ExportPDF, Excel, multi-curve overlay, bilingual (EN/CN) reporting
Safety ProtectionsOverpressure, overcurrent, short-circuit, leakage, and software operation lockout
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelGEST-20042
PriceUSD 1,400 (FOB Beijing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelPMQS-I
PriceUSD 2,800 (approx.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
ModelBETA202A
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Method (BET & DFT/NLDFT)
Analysis Stations1 dedicated station (optional dual-station configuration with 3 pressure transducers)
Surface Area Range0.0001 m²/g (using Kr adsorption) to unlimited
Pore Size Range0.35 nm – 500 nm
Pressure Range0–133 kPa (0–1000 Torr)
Repeatability±1%
Detection Limit for Pore Volume0.0001 cm³/g (N₂)
P/P₀ Resolutiondown to 1×10⁻⁷
Ultimate Vacuum≤1×10⁻⁸ Torr (with optional turbomolecular pump)
Thermal ControlLiquid nitrogen isothermal jacket + 70-hour Dewar capacity
Gas CompatibilityN₂, Ar, Kr, CO₂, NH₃, H₂, CO, O₂, CH₄, C₄H₁₀ (non-corrosive only)
Data Acquisition24-bit ADC, capacitive absolute pressure transducers (0.1% full-scale accuracy)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelBETA201A2
Instrument TypeSpecific Surface Area Analyzer
Measurement PrincipleStatic Volumetric Method (with optional dynamic mode capability)
Number of Analysis Stations4
Surface Area Range0.0001 m²/g (using Kr adsorption) to unlimited
Pressure Range0–133 kPa
Repeatability±1% (typical under controlled conditions)
Pore Size Range0.35 nm – 500 nm
Minimum Detectable Pore Volume0.0001 cm³/g (N₂ adsorption, with high-vacuum option)
Analysis Time~25 min per surface area measurement
Gas CompatibilityN₂, Ar, Kr, NH₃, CO₂, H₂, CO, O₂, CH₄, C₄H₁₀ (non-corrosive only)
Vacuum Base Pressure≤1×10⁻⁴ Torr (standard)
P/P₀ Resolutionup to 0.9995
DetectorImported capacitive absolute pressure transducer (0–10 Torr & 0–1000 Torr ranges), 0.1% full-scale accuracy, 24-bit ADC
Sample Tube HeatingIntegrated in-situ degassing with dual-path valve isolation
Data InterfaceUSB or Ethernet (RJ45)
Software LanguageSwitchable Chinese/English UI & report output
ComplianceDesigned for GLP-compliant environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCPMFY-A
PriceUSD 2,650 (FOB Beijing)
ComplianceGB/T 26392–2011, ASTM D3574–08 Section 12 (Recovery Time for Viscoelastic Polyurethane Foams)
Measurement PrincipleControlled-compression dynamic recovery timing via high-precision laser displacement sensing and load-controlled indentation
Control SystemSiemens S7-1200 PLC with integrated motion control
Display7-inch industrial capacitive touchscreen HMI
Time Resolution0.01 s
Thickness MeasurementNon-contact laser triangulation (±1 mm accuracy)
Indentation Force Sensor1000 N capacity, ±0.5% FS accuracy
IndenterRigid circular plate, Ø203 mm
Support PlatePerforated steel plate, hole Ø6.5 mm, pitch 20 mm
Test Speed(1000 ± 100) mm/min (programmable bidirectional)
Specimen Dimensions380 × 380 × 100 mm (L × W × H)
Preload Force4.5 N (automatically applied and verified)
Compression Depth75% of initial specimen thickness (user-confirmed via real-time laser thickness reading)
Hold Duration60 s (configurable)
Recovery ThresholdTime elapsed until specimen re-applies 4.5 N preload force upon upward indenter return
Data OutputCSV via USB
Software ArchitectureEmbedded deterministic real-time control firmware
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instrument
OriginBeijing, China
ModelPMLQ-500B
Drop Height460 mm (GB/ISO) / 500 mm (ASTM)
Steel Ball Diameter16 mm
Sample Dimensions100 × 100 × 50–100 mm
Rebound Accuracy<1%
Sample Capacity3 specimens per test group
Height DetectionAutomatic optical height sensing with dual verification (auto + manual scale reference)
Control SystemSiemens PLC with 7-inch HMI touchscreen interface
Power Supply220 V / 50 Hz
Dimensions (L×W×H)560 × 360 × 860 mm
Weight25 kg
ComplianceGB/T 6670–2008, GB/T 10652–2001, ISO 8307, ASTM D3574
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMLQ-500.2
Compliance StandardsGB/T 6670–2008, ISO 8307:2017, ASTM D3574–2022, GB/T 10652–2001
Ball Drop Height460 mm (GB/ISO), 500 mm (ASTM)
Ball DiameterØ16 mm
Guide TubeTransparent acrylic, inner diameter Ø50 mm
Rebound Accuracy<1%
Specimen Dimensions100 mm × 100 mm × (50–100) mm
Specimen Sets per Test3
Height DetectionAutomatic optical height sensing with digital storage
Rebound Ratio CalculationFully automated single-value and mean rebound ratio (R = h₁/h₀ × 100%)
Dual Release ModeElectromagnetic (standard), manual mechanical release
Reading MethodIntegrated high-resolution optical sensor + calibrated scale for manual verification
Form FactorBenchtop
Dimensions (L×W×H)560 × 360 × 860 mm
Weight25 kg
Power Supply220 V AC, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelBETA201A.2
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Volumetric Method (with Dynamic Mode Support)
Analysis Stations1
Surface Area Range0.0001 m²/g (Kr adsorption) to unlimited
Pressure Range0–133 kPa
Repeatability< ±1% (per ASTM D3663 and ISO 9277)
P/P₀ ResolutionDown to 1×10⁻⁷
Vacuum Base Pressure≤1×10⁻⁸ Torr (with optional turbomolecular pump)
Adsorption GasesN₂, Ar, Kr, CO₂, NH₃, H₂, CO, O₂, CH₄, C₄H₁₀ (non-corrosive only)
Analysis Time~25 min for surface area (N₂), ~3.5 h for full pore size distribution (N₂, 77 K)
Sample Temperature ControlLiquid nitrogen isothermal jacket with 70-h autonomous operation (optional auto-refill system)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0