- All
- Favorite
- Popular
- Most rated
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCTKP-700H |
| Price | USD 1,280 (FOB Beijing) |
| Temperature Range | Ambient to 700 °C |
| Heating Rate | Programmable, 0.1–20 °C/min (standard) |
| Temperature Accuracy | ±1 °C (after stabilization, per ASTM E228 calibration protocol) |
| Displacement Range | 0–1 mm |
| Measurement Resolution | ±0.001 mm |
| Sample Dimensions | (i) Ø50 mm × 60 mm cylindrical |
| Atmosphere Control | Pressure range 0–50 kPa (gauge), compatible with inert (N₂, Ar), oxidizing (air), or reducing (5% H₂/95% N₂) environments |
| Power Supply | 220 V AC, 50 Hz, 1.7 kW |
| Thermocouple | Type K, 0–1000 °C, Class 0.1 accuracy |
| Gas Flow Control | Digital mass flow controller, 0–80 L/min |
| Unit Dimensions | 700 × 810 × 1150 mm (W × D × H) |
| Net Weight | 150 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCTKP-700b |
| Price | USD 1,280 (FOB Beijing) |
| Temperature Range | Ambient to 700 °C |
| Heating Rate | Programmable, 0.1–10 °C/min (standard configuration) |
| Temperature Accuracy | ±1 °C (after thermal equilibrium, per ASTM E228 calibration protocol) |
| Displacement Range | 0–1 mm |
| Measurement Resolution | ±0.001 mm |
| Sample Dimensions | (i) Ø50 mm × 60 mm cylindrical |
| Atmosphere Control | Pressure range 0–50 kPa (gauge), compatible with inert (N₂, Ar), reducing (5% H₂/95% N₂), or vacuum conditions |
| Power Supply | 220 V AC / 50 Hz / 1.7 kW |
| Thermocouple | Type K, 0–1000 °C, Class 0.1 accuracy |
| Gas Flow Control | Mass flow controller, 0–80 L/min |
| Dimensions (W×D×H) | 700 mm × 810 mm × 1150 mm |
| Net Weight | 150 kg |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GCRPZ-1000 |
| Temperature Range | Ambient to 1000 °C |
| Heating Rate | 0.1–10 K/min (adjustable) |
| Temperature Accuracy | ±1 °C |
| Sample Dimensions | Max. 50 mm length × 8 mm diameter |
| Measurement Range | ±5 mm |
| Resolution | 0.1 µm |
| Atmosphere Options | N₂, Ar, inert gases, vacuum (–0.1 MPa) |
| Sensor Type | Optical Grating Displacement Transducer |
| Sample Holder Material | Fused Quartz |
| Power Supply | 220 V ±10%, 50 Hz |
| Cooling Requirement | External recirculating chiller (max. 100 °C bath temp, ≤2 kW heating power) |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCRPZ-1000.2 |
| Price | USD 1,700 (FOB) |
| Temperature Range | Ambient to 1000 °C |
| Heating Rate | 0.1–10 K/min (programmable) |
| Temperature Accuracy | ±1 °C |
| Sample Dimensions | Max. 50 mm length × 8 mm diameter |
| Measurement Range | ±5 mm |
| Resolution | 0.1 µm |
| Atmosphere Options | N₂, Ar, inert gas, vacuum (−0.1 MPa) |
| Sample Holder Material | Fused quartz |
| Power Supply | 220 V ±10%, 50 Hz |
| Cooling Requirement | External water chiller (max. 100 °C inlet, ≤2 kW heating power) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCTKP-700 |
| Temperature Range | Ambient to 700 °C |
| Heating Rate | Programmable, up to 10 °C/min (typical) |
| Temperature Accuracy | ±1 °C (after thermal equilibrium) |
| Displacement Range | 0–1 mm |
| Displacement Resolution | ±0.001 mm |
| Sample Dimensions | (i) Ø50 mm × 60 mm |
| Atmosphere Control | Pressure range 0–50 kPa (gauge), compatible with inert, reducing, or vacuum environments |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 1.7 kW |
| Thermal Sensor | K-type thermocouple (0–1000 °C, Class 0.1 accuracy) |
| Gas Flow Control | 0–80 L/min (mass flow controller) |
| Instrument Dimensions | 700 × 810 × 1150 mm (W × D × H) |
| Net Weight | 150 kg |
| Brand | Guance Instruments |
|---|---|
| Model | GCDZY-I2 |
| Temperature Range | 200 °C |
| Heating Rate | 0–200 °C/min |
| Temperature Accuracy | ±2 °C at 200 °C |
| Sample Chamber Dimensions | Ø68 mm × 120 mm (ID × height) |
| Tumbling Speed | 90 rpm |
| Tumbling Duration | Programmable |
| Steel Ball Diameter | 6 mm |
| Power Rating | 1 kW |
| Supply Voltage | 220 V / 50 Hz |
| Overall Dimensions | 700 × 640 × 690 mm (L×W×H) |
| Net Weight | 50 kg |
| Compliance | YS/T 63.11–2006, YS/T 63.12–2006 |
| Atmosphere Capability | Ambient air or inert gas (N₂, Ar) – configurable via external gas inlet |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCTKP-700C |
| Temperature Range | Ambient to 700 °C |
| Heating Rate | Programmable (0–10 °C/min typical) |
| Displacement Range | 0–1 mm |
| Displacement Resolution | ±0.001 mm |
| Sample Dimensions | Ø50 mm × 60 mm or ≥5 mm cross-section × ≥50 mm length |
| Atmosphere Control | 0–50 kPa (gauge), compatible with inert/N₂/air/vacuum |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 1.7 kW |
| Thermocouple | Type K (0–1000 °C, Class 0.1 accuracy) |
| Gas Flow Meter | 0–80 L/min |
| Dimensions (W×D×H) | 810 × 700 × 1150 mm |
| Weight | 150 kg |