Empowering Scientific Discovery

Beijing Guance Jingdian Instrumentation & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCSTD-AB3
PriceUSD 270 (FOB)
Test Frequency Range10 kHz – 10 MHz (typical for AB3 variant)
Measurement PrincipleHigh-Frequency Resonance Method (Q-meter based)
DisplayDigital LCD with Auto-Resonance Search & Frequency Locking
Supported Sample FormsSolid, Liquid, Powder
Standard Electrode DiameterΦ38 mm
Solid Sample Thickness Range0.5–15 mm
Liquid Cell DimensionsΦ48 mm ID × 7 mm depth (optional)
Operating Temperature0–40 °C
Relative Humidity<80% RH
Power Supply220 V ±10%, 50 Hz ±2.5 Hz
Power Consumption~25 W
Net Weight~7 kg
Dimensions (L×W×H)380 × 280 × 132 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
ModelGCSTD-F.4
Frequency Range10 Hz – 10 MHz (typical for F-series)
Electrode ConfigurationCoaxial Cylindrical (316 Stainless Steel Outer/Inner Cylinders)
Electrode SpacingFixed via Six Nylon Set Screws
Material CompatibilityStainless Steel / Nylon / PTFE
Cleaning ProtocolSolvent Immersion (Acetone/Ethanol) + Ultrasonic Bath
Calibration SupportTwo-Point Capacitance-Based Calibration (Air & Standard Liquid Reference)
Compliance ContextDesigned for ASTM D150, IEC 60250, and ISO 18738-compliant dielectric characterization workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGDW-500d
PriceUSD 1,400 (approx.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelGCSTD-FI.4
PriceUSD 2,000 (FOB)
Measurement PrincipleTwo-Terminal Capacitance Bridge at Fixed 10 kHz
Electrode TypeOpen-Geometry Cylindrical Stainless Steel (316 SS)
Frequency10 kHz Sine Wave
RMS Excitation Voltage7 V (Range 1–20), 0.7 V (Range 1–200)
Dielectric Constant Range1–20 and 1–200
Accuracy±2%
Repeatability & Linearity±0.2%
ComplianceGB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGDW-500.3
PriceUSD 2,200 (FOB)
Temperature Range−160 °C to +500 °C
Temperature Stability±0.5 °C
Electrode MaterialBrass
Electrode Diameter25 mm
Test Frequency Range20 Hz – 2 MHz
Heating MethodElectric Resistance Heating
Cooling MethodLiquid Nitrogen Cryogenic Cooling
ComplianceGB/T 1409–2006, GB/T 1693–2007, ASTM D150, IEC 60250
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGDW500.3
PriceUSD 1,980 (FOB)
Temperature Range−160 °C to +500 °C
Temperature Control Accuracy±0.5 °C
Cooling MethodLiquid Nitrogen
Heating MethodResistive Electric Heating
Electrode MaterialBrass
Electrode Diameter25 mm
Test Frequency Range20 Hz – 2 MHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCWP-A1
PriceUSD 1,280 (FOB Beijing)
Electrode Diameter6 mm
Number of Electrodes4
Electrode ShieldingInner layer — 304 stainless steel
Measurement Channels4-channel simultaneous testing
Frequency SwitchingProgrammable sample switching interval
Operating ModesManual and automated test sequences
Data ExportRaw impedance/dielectric data (CSV/Excel), real-time Lissajous & Cole–Cole plots, printable ASTM-compliant test reports
Measurement Frequency RangeCompatible with Agilent 4294A Precision Impedance Analyzer (40 Hz – 110 MHz)
Temperature Range−180 °C to +500 °C
Heating Rate0.5–2.5 °C/min (programmable)
Signal CablingSilver-plated copper low-temperature shielded cables
Enclosure MaterialQ235 carbon steel chassis with high-temp epoxy powder coating
Power SupplyAC 220 V, 50 Hz, 2 kW
Reference Impedance AnalyzerAgilent 4294A (or equivalent IEC 60250–compliant bridge)
Environmental RequirementsAvoid dusty, high-vibration, direct-sunlight, or corrosive-gas environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCSTD-D
PriceUSD 450 (FOB)
Frequency Range20 Hz – 2 MHz (10 mHz resolution)
Test Signal Level10 mV – 5 Vrms (1 mV step)
Basic Accuracy±0.1%
Measurement SpeedUp to 200 readings/sec
Display320×240 dot-matrix LCD
Impedance Parameters22 selectable combinations (e.g., C–D, C–Q, L–Q, R–X, Z–θ)
Electrode OptionsFixed disk electrodes (φ38 mm / φ50 mm standard), liquid cell (15 mL capacity), powder cell (customizable volume)
Sample TypesSolids, liquids, powders, pastes, regular or irregular geometries
ComplianceGB/T 1409–2006, GB/T 1693–2007, ASTM D150, IEC 60250
InterfaceUSB Host, RS232, GPIB (optional), Handler I/O
DC BiasInternal ±10 V / 100 mA
ALA/ALCAutomatic Level Control and Voltage/Current monitoring
Scan Modes10-point list sweep, graphical analysis (
Memory20 instrument setups
Comparator10-bin sorting with pass/fail indication and counting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
ModelGCWP-A4
Measurement PrinciplePrecision Impedance Bridge (Agilent 4294A-based)
Electrode ConfigurationQuadruple-channel guarded electrode system (4 × 6 mm stainless-steel electrodes)
ShieldingDual-layer coaxial shielding — inner tube: 304 stainless steel, outer jacket: PTFE
Temperature Range−180 °C to +500 °C
Heating Rate0.5–2.5 °C/min
Data InterfaceSilver-plated copper low-noise cryogenic shielded cables
ComplianceDesigned for ASTM D150, IEC 60250, and ISO 257-1/2 environments
Power SupplyAC 220 V, 50 Hz, 2 kW
EnclosureQ235 steel chassis with high-temp epoxy powder coating
Operating EnvironmentRequires low-vibration, low-dust, EMI-shielded laboratory
Data OutputRaw impedance spectra (.csv), loss tangent (tan δ) vs. frequency/temperature plots, printable test reports with timestamped metadata
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCSTD-D2
Price RangeUSD 1,550 – 5,600
Frequency Range20 Hz – 2 MHz (10 mHz resolution)
Test Signal Level10 mV – 5 V (1 mV step)
Basic Accuracy±0.1%
Measurement SpeedUp to 200 readings/s
Display320 × 240 dot-matrix graphical LCD
Resolution5-digit
Impedance Parameters22 configurable combinations
DC Bias SourceInternal
External DC Bias Current SupportUp to 40 A (with dual TH1776 units, optional)
ALP/ALCAutomatic Level Control with V/I monitoring
Sweep Modes10-point list sweep, graphical analysis
Memory20 instrument setups
Comparator10-bin sorting with counting
InterfacesUSB Host, RS232, GPIB (optional), Handler I/O
Electrode OptionsFixed disk electrodes (Ø38 mm / Ø50 mm standard), liquid cell (15 mL capacity), powder-specific electrode kits
Sample TypesSolids, liquids, powders, pastes, regular or irregular geometries
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCSTD-AB4
PriceUSD 1,890 (FOB Beijing)
Frequency Range10 kHz – 1 MHz (low-frequency band, compliant with GB/T 1409–2006 & ASTM D150)
Measurement ParametersRelative Permittivity (εᵣ), Dissipation Factor (tan δ)
Test MethodAutomatic Resonant Frequency Sweep with Digital Frequency Locking
Electrode ConfigurationSolid/liquid/powder-compatible parallel-plate electrodes (Φ38 mm measuring electrode
optional liquid cellΦ48 mm × 7 mm depth)
Sample Thickness Range (solid)0.5–15 mm
Operating Temperature0–40 °C
Humidity Limit<80% RH
Power Supply220 V ±10%, 50 Hz ±2.5 Hz
Power Consumption~25 W
Net Weight7 kg
Dimensions (L×W×H)380 × 280 × 132 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGDW-500e
PriceUSD 980 (FOB)
Temperature Range−160 °C to +500 °C
Temperature Stability±0.5 °C
Heating MethodElectric Cartridge Heater
Cooling MethodLiquid Nitrogen Cryogenic Cooling
Electrode MaterialBrass
Electrode Diameter25 mm
Test Frequency Range20 Hz – 2 MHz
ComplianceGB/T 1409–2006, GB/T 1693–2007, ASTM D150, IEC 60250
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCSTD-F1
PriceUSD 1,850 (FOB Beijing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (PRC)
ModelGCSTD-FI3
PriceUSD 1,900 (FOB Beijing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGDW-500C
PriceUSD 2,100 (FOB)
Temperature Range−160 °C to +500 °C
Temperature Stability±0.5 °C
Cooling MethodLiquid Nitrogen
Heating MethodResistive Cartridge Heating
Electrode MaterialBrass
Electrode Diameter25 mm
Test Frequency Range20 Hz – 2 MHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instruments
OriginBeijing, China
ModelGCWP-A
Electrode Diameter6 mm (4 electrodes)
Electrode ShieldingInner layer – 304 stainless steel
Channel ConfigurationQuad-channel simultaneous measurement
Frequency SwitchingProgrammable sample switching interval
Operating ModesManual and automated sequence control
Data ExportRaw data export (CSV/Excel), real-time curve plotting, printable test reports
Frequency RangeDetermined by integrated Agilent 4294A Precision Impedance Analyzer
Temperature Range−180 °C to +500 °C
Heating Rate0.5–2.5 °C/min (programmable)
Cryogenic CablingSilver-plated copper shielded cables
EnclosureQ235 carbon steel chassis with high-temp epoxy powder coating
Power SupplyAC 220 V, 50 Hz, 2 kW
Core Impedance AnalyzerAgilent 4294A
Environmental RequirementsAvoid dusty, high-vibration, direct sunlight, or corrosive gas environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGDW-500.2
PriceUSD 1,700 (approx.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Region of ManufactureDomestic (China)
ModelGCSTD-CII2
PriceUSD 1,150 (FOB Beijing)
Standard ComplianceGB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985
Operating Frequency45–65 Hz (Auto-Tuned to 50 Hz Nominal)
Measurement ModesDirect Connection, Reverse Connection, External HV Source Mode
Output Voltage Range2.5 kV, 5 kV, 10 kV (5-step adjustable, integrated HV generator)
tanδ Range0.00%–99.9%, Resolution: 0.01%, Accuracy: ±(1% × reading + 0.09%)
Cx Range30 pF–0.3 µF (internal HV), Resolution: 0.1 pF, Accuracy: ±(1.5% × reading + 1 pF)
Input Power220 V ±10%, 50 Hz, 1.5 kVA
Dimensions (L×W×H)470 × 320 × 360 mm
Weight16 kg
Ambient Temp10–30 °C
Relative Humidity20–80% RH
DisplayLarge LCD with Chinese menu interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGDW-250D
PriceUSD 1,800 (FOB Beijing)
Temperature RangeAmbient to 250 °C
Sample Chamber Dimensions600 mm (L) × 400 mm (W) × 400 mm (H)
Enclosure MaterialPowder-Coated Steel
Input Power220 V AC, 50 Hz, Three-Phase
Operating Humidity<50 % RH
Ambient Temp22–27 °C
Compressed Air Supply0.5 MPa (clean, oil-free)
Positive-Pressure Purge Air0.05 MPa (explosion-proof inert gas optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Region of ManufactureDomestic (China)
ModelGCSTD-A/B
PriceUSD 1,400 (approx.)
Measurement PrincipleResonant Frequency Method (Q-meter based)
Frequency RangeSelectable across three variants (A/B/C — model-specific bands, typically 1 MHz to 100 MHz)
Sample TypesSolid, Liquid, Powder
Electrode Diameter38 mm (standard)
Solid Sample Thickness Range0.5–15 mm
Liquid Cell DimensionsID 48 mm × Depth 7 mm (optional)
Operating Temperature0–40 °C
Relative Humidity<80% RH
Power Supply220 V ±10%, 50 Hz ±2.5 Hz
Power Consumption~25 W
Net Weight~7 kg
Dimensions (L×W×H)380 × 280 × 132 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelGCSTD-CII6
PriceUSD 1,400 (FOB Beijing)
Standard ComplianceGB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985
Measurement PrincipleSchering Bridge (Auto-balancing AC Bridge) at Power Frequency (50 Hz ± variable frequency suppression)
Test Voltage Range2.5 kV – 10 kV (5-step adjustable, integrated HV source)
tanδ Accuracy±(1% × reading + 0.09%)
Cx Accuracy±(1.5% × reading + 1 pF)
tanδ Resolution0.01%
Cx Resolution0.1 pF
Sample InterfaceInternal HV electrode fixture for cylindrical insulating sleeves (Ø38 mm, Ø50 mm, Ø100 mm)
Operating Temp.10–30 °C
Relative Humidity20–80% RH
Power Supply220 V ±10%, 50 Hz, 1.5 kVA
Dimensions (L×W×H)470 × 320 × 360 mm
Weight16 kg
DisplayLarge-character LCD with Chinese menu navigation
ProtectionOvercurrent trip, arc detection, short-circuit & flashover safeguard
Data OutputBuilt-in thermal printer, RS232 interface for PC logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCSTD-FI.2
Test Frequency10 kHz Sinusoidal Signal
Measurement Ranges1–20 and 1–200 (dimensionless relative permittivity scale)
Accuracy±2%
Repeatability & Linearity±0.2% RMS
Electrode TypeExternal coaxial cylindrical probe (316 stainless steel outer/inner cylinders, nylon spacers, PTFE-insulated)
Excitation Voltage~7 V RMS (range 1–20), ~0.7 V RMS (range 1–200)
ComplianceGB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuance Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCSTD-D.1
PriceUSD 265 (approx.)
Frequency Range20 Hz – 2 MHz (10 mHz resolution)
Test Signal Level10 mV – 5 V (1 mV step)
Basic Accuracy±0.1%
Measurement Speedup to 200 readings/sec
Display320×240 dot-matrix LCD
Readout Resolution5 digits
Impedance Parameters22 configurable combinations
Output Impedance Options10 Ω / 25 Ω / 50 Ω / 100 Ω
DC Bias SourceInternal ±10 V / 100 mA
External DC Bias SupportUp to ±40 A (with dual TH1776 units, optional)
Auto Level Control (ALC)Yes
V/I MonitoringReal-time test signal voltage/current monitoring
Graphic Sweep AnalysisFrequency, level, and bias sweeps with on-screen plot
Storage20 instrument setups
Comparator10-bin sorting with pass/fail counting
InterfacesUSB Device/Host, RS232, GPIB (optional), LAN (optional)
Electrode OptionsFixed disk electrodes (Ø38 mm / Ø50 mm, standard: Ø38 mm), liquid cell (15 mL capacity), powder cell (customizable volume)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGuanCe Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGCSTD-FI.7
Frequency Range10 kHz sinusoidal excitation
Measurement Ranges1–20 and 1–200 (dimensionless relative permittivity scale)
Accuracy±2%
Repeatability & Linearity±0.2% RMS
Electrode TypeExternal coaxial cylindrical probe (316 stainless steel outer/inner cylinders, nylon spacers, PTFE-insulated)
Excitation Amplitude~7 V RMS (range 1–20), 0.7 V RMS (range 1–200)
ComplianceGB/T 1409–2006, GB/T 5654–2007, GB/T 21216–2007, GB/T 1693–2007, GB/T 5594.4–1985
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0