| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCDC-03 |
| Impact Mass | 9.1 kg or 10 kg stainless steel impact hammer |
| Impact Height Range | 300–1200 mm (adjustable, digital height indicator, ±2 mm accuracy) |
| Height Adjustment | Motorized |
| Crossbar Diameter | 15.8 mm (5/8 in) stainless steel rod |
| Load Cell Range | 0–200 N |
| Maximum Lifting Height | 200 mm |
| Power Supply | 220 V, 50/60 Hz, 3 A |
| Net Weight | ~145 kg |
| Chamber Construction | Inner chamber – 304 stainless steel |
| Viewing Window | Dual-layer tempered explosion-proof glass with integrated LED lighting |
| Exhaust Port | 120 mm diameter, rear-mounted |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CLC-AI3 |
| Quotation | USD 2,200 (FOB Beijing) |
| Instrument Type | Drop-Weight Impact Tester |
| Maximum Impact Energy | 0–150 J |
| Maximum Impact Velocity | 5.5 m/s |
| Hammer Mass Options | 2–10 kg (standard configurations: 5 kg, 15 kg, 20 kg) |
| Displacement Resolution | 0.01 mm |
| Crosshead Speed Range (for auxiliary positioning) | 0.01–1000 mm/min (infinitely adjustable) |
| Maximum Lift Height | 1500 mm |
| Dimensions (L×W×H) | 1200 × 700 × 2100 mm |
| Net Weight | 300 kg |
| Compliance | ISO 3127, ISO 6603, ISO 7765, ISO 8256, ISO 11343, PREN 6038, DIN 53373, ASTM D2444, ASTM D3763, ASTM D5628, ASTM D7136, ASTM D7192 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCDC-03.5 |
| Impact Mass | 9.1 kg or 10 kg stainless steel impact hammer |
| Impact Height Range | 300–1200 mm (adjustable, digital height display, ±2 mm accuracy) |
| Height Adjustment | Motorized |
| Crossbar Diameter | 15.8 mm (5/8 in) stainless steel rod |
| Load Cell Range | 0–200 N |
| Maximum Lifting Height | 180 mm |
| Compliance Standards | IEC 62133, UN 38.3, UL 1642:2008, UL 2054:2008, QC/T 743–2006, QC/T 742–2006, QC/T 744–2006, GB/T 18287–2000, GB 8897.4–2002 (IEC 60086-4:2000), SJ/T 11169–1998, SJ/T 11170–1998 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CLC-AI |
| Quotation | USD 4,200 (FOB Beijing) |
| Instrument Type | Drop-Weight Impact Tester |
| Impact Energy | 300 J |
| Impact Velocity | 25 m/s |
| Hammer Moment (Impact Constant) | 24 N·m |
| Load Cell Range | 300 kN |
| Maximum Lift Height | 1500 mm |
| Hammer Mass Options | 5 kg / 15 kg / 20 kg (customizable) |
| Effective Impact Height | 1500 mm |
| Dimensions (L×W×H) | 1200 × 700 × 2100 mm |
| Weight | 300 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCCBC Series |
| Instrument Type | Pendulum Impact Tester |
| Impact Energy Options | 0.5 J / 1 J / 2 J / 4 J / 7.5 J / 15 J / 25 J / 50 J (simply supported beam) |
| Impact Velocity | ≤4 J: 2.9 m/s |
| ≥7.5 J | 3.8 m/s (simply supported) |
| Pendulum Moment (Impact Constant) | 18 N·m/rad |
| Load Cell Range | 1–20 kN |
| Maximum Lifting Height | 1550 mm |
| Support Span | 230 mm (simply supported), 335 mm (cantilever) |
| Specimen Dimensions (simply supported) | Length: 40–95 mm |
| Width | 4–15 mm |
| Thickness | 3–10 mm |
| Specimen Dimensions (cantilever) | Length: 63.5±2 mm or 80±2 mm |
| Width | 12.7±0.2 mm or 10±0.2 mm (max 50 mm) |
| Thickness | 3.2–40 mm |
| Anvil Radius | R = 1 mm (simply supported), R = 0.8 mm (cantilever) |
| Striking Edge Angle | 30° |
| Striking Edge Radius | R = 2 mm |
| Power Supply | 220 V AC, 200 W |
| Release Mechanism | Electromechanical (motor-driven) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CLC-AI.11 |
| Instrument Type | Drop-Weight Impact Tester |
| Impact Energy Range | 0–100 J (pneumatically adjustable clamping force) |
| Maximum Impact Velocity | 5.5 m/s |
| Hammer Mass Options | 2–7 kg (standard configuration includes 5 kg, 15 kg, and 20 kg hammers) |
| Maximum Lift Height | 3000 mm |
| Effective Test Height | 1500 mm |
| Force Sensor Range | 0–100 J equivalent |
| Dimensions (L×W×H) | 1200 × 700 × 2100 mm |
| Weight | 300 kg |
| Automation Features | Motorized hammer lifting, automatic hammer latching/release, anti-reimpact safety mechanism |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CLC-AI2 |
| Instrument Type | Drop-Weight Impact Tester |
| Impact Energy Range | 0–100 J (standard) |
| Impact Velocity | 5.5 m/s (standard) |
| Hammer Mass Range | 2–7 kg |
| Force Sensor Range | 0–100 J (energy equivalent) |
| optional load cells | 10–250 kN |
| Maximum Lift Height | 2000 mm |
| Test Chamber Dimensions | 600 × 550 × 450 mm |
| Hammer Tip Diameters | Ø12, Ø12.5, Ø16, Ø20 mm (±0.1 mm) |
| Hammer Hardness | HRC 60–65 |
| Positioning Accuracy | ±1 mm |
| Dynamic Test Error | <2% |
| Data Acquisition Rate | 2 MHz |
| ADC Resolution | ≥16-bit |
| Force Sensor Sensitivity | 0.05–1 mV/lbf |
| Accelerometer Sensitivity | 2 pC/(m/s²) |
| Frequency Response (Accelerometer) | 1–12,000 Hz |
| Operating Temperature Range | –40°C to +150°C (optional environmental chamber) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCCLC-C |
| Instrument Category | Other Impact Testing Machines |
| Impact Energy Range | Adjustable drop height 0–500 mm / 0–1000 mm |
| Impact Velocity | Determined by free-fall kinematics (9.81 m/s²) |
| Force Sensor Options | 2 kN / 5 kN / 10 kN (user-selectable) |
| Pendulum Moment (Impact Constant) | 800 N·mm/rad |
| Force Sensor Measurement Range | 10–80 N (for low-force cushioning characterization) |
| Maximum Lift Height | 80 mm (for sensor pre-tensioning or minor vertical adjustment) |
| Drop Mass | Standardized steel spheres (mass configurable per ASTM D3574, ISO 18562-3, or customer specification) |
| Data Acquisition Rate | 1 MHz |
| Actuation | Motorized height adjustment & solenoid-triggered release |
| Compliance | Designed to support testing protocols aligned with ASTM D1564, ASTM D3574 Section 12 (Cushioning Performance), ISO 18562-3 (Biocompatibility of breathing gas pathways – impact resilience), and GB/T 20485.21 (Chinese national standard for vibration and shock testing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCCLC-C.3 |
| Impact Height Range | 0–500 mm / 0–1000 mm (adjustable) |
| Impact Force Sensor Options | 2 kN / 5 kN / 10 kN |
| Pendulum Moment (Impact Constant) | 80 N·m/rad |
| Force Sensor Measurement Range | 10–60 N |
| Maximum Lifting Height | 100 mm |
| Data Acquisition Rate | 1 MHz |
| Release Mechanism | Motorized electromagnetic release |
| Height Adjustment | Motor-driven vertical positioning |
| Steel Ball Mass | Configurable per test standard (e.g., 16 g, 42 g, 100 g, 200 g per ASTM D1564, ISO 179-1, or customer-specified) |
| Compliance | Designed for ASTM D3367 (Foam Cushioning), ISO 18562-2 (Biocompatibility of medical device packaging), and GB/T 21661–2022 (Packaging cushioning performance testing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCCBC-B Series |
| Impact Energy Options | 1 J / 5 J / 25 J / 50 J (Charpy) |
| Impact Velocity | ≤4 J: 2.9 m/s |
| ≥7.5 J | 3.8 m/s (Charpy) |
| Pendulum Moment (Impact Constant) | 18 N·m |
| Load Cell Range | 16 kN |
| Maximum Lifting Height | 150 mm |
| Support Span | 230 mm (Charpy), 335 mm (Izod) |
| Pre-lift Angle | 150° |
| Specimen Dimensions (Charpy) | 40–95 mm (L) × 4–15 mm (W) × 3–10 mm (T) |
| (Izod) | 61.5–82 mm (L) × 10–12.7 mm (W) × 3.2–12.7 mm (T) |
| Anvil Radius | R = 1 mm (Charpy), R = 0.8 mm (Izod) |
| Striking Edge Angle | 30° |
| Striking Edge Radius | R = 2 mm |
| Power Supply | 220 V AC, 200 W |
| Release Mechanism | Electromagnetic motor-driven release |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCCLC-C.5 |
| Impact Height Range | 0–500 mm / 0–1000 mm (adjustable) |
| Impact Force Sensor Options | 2 kN / 5 kN / 10 kN |
| Maximum Lifting Height | 80 mm |
| Pendulum Moment (Impact Constant) | 60 N·m |
| Force Sensor Capacity | 50 kN |
| Data Acquisition Rate | 1 MHz |
| Release Mechanism | Motorized |
| Height Adjustment | Motorized Vertical Positioning |
| Test Mass | Standardized steel spheres (mass configurable per ASTM D3574, ISO 1856, or customer specification) |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CLC-AI8 |
| Instrument Type | Drop-Weight Impact Tester |
| Impact Energy | 100 kN·mm (equivalent to 98 J at 2 m drop height) |
| Impact Velocity | 9.8 m/s (theoretical free-fall velocity from 4.9 m |
| Hammer Mass Options | 5 kg / 15 kg / 20 kg |
| Maximum Lift Height | 2000 mm |
| Load Cell Range | 100 kN |
| Effective Impact Height Range | 1500 mm |
| Frame Dimensions (L×W×H) | 1200 × 700 × 2100 mm |
| Unit Weight | 300 kg |
| Compliance | ISO 3127, ISO 6603, ISO 7765, ISO 8256, ISO 11343, ASTM D2444, ASTM D3763, ASTM D5628, ASTM D7136, ASTM D7192, DIN 53373, prEN 6038 |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Model | GCCLCT-1500 |
| Impact Energy | 155 J |
| Impact Velocity | 198 cm/s |
| Pendulum Torque (Impact Constant) | 16 N·m |
| Load Cell Range | 12–17 kN |
| Maximum Lift Height | 1500 mm |
| Hammer Mass Options | 1 kg / 2 kg / 3 kg |
| Hammer Tip Diameter | Φ16 mm / Φ25 mm |
| Guide Tube ID | 48 mm, Length: 1200 mm |
| Anvil Radius (Curved) | 40 mm, Hardness: 55 HRC ±5 HRC |
| Flat & V-Groove Anvils | 55 HRC ±5 HRC |
| Specimen Fixing | Mechanical clamping for flat, curved, and tubular specimens (DN50–DN150, L=300 mm) |
| Compliance | SY/T 0315–2013 Annex D, GB/T 23257–2009 Annex L |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCCLC-AII |
| Impact Energy Range | 50–300 J |
| Impact Velocity | 2–5.5 m/s |
| Pendulum Torque (Impact Constant) | 15 N·m |
| Load Cell Capacity | 16 kN |
| Maximum Lifting Height | 1500 mm |
| Temperature Chamber Range | −40 °C to +100 °C |
| System Sampling Rate | 2 MHz |
| A/D Resolution | 16-bit |
| Frequency Response | 500 kHz |
| Dynamic Test Error | <2% |
| Overall Dimensions (w/o chamber) | 850 × 1700 × 3300 mm |
| Net Weight | 1200 kg |