- All
- Favorite
- Popular
- Most rated
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | PMTQ-A.3 |
| Price | USD 2,100 (FOB Beijing) |
| Standards Compliance | ISO 4638:1984, GB/T 10655, AQ 1088-2011, ASTM D3574-2005 |
| Vacuum Pump | 1.3 m³/h (4.8 L/s), Ultimate Vacuum: 5 × 10² Pa |
| Flow Sensor Range | 0–50 L/min |
| Differential Pressure Sensors | Dual-range — 0–400 Pa & 0–100 Pa |
| Test Chamber Dimensions | 100 mm × 100 mm × 104 mm (L×W×H) |
| Specimen Size | 102 mm × 102 mm × (0–100) mm (thickness) |
| Air Permeability Range | 0–999.9 × 10⁻¹⁰ m² |
| Temperature Sensor | −40 °C to +80 °C |
| Chamber Material | 4 mm 304 brushed stainless steel |
| Safety Protections | Over-temperature, over-pressure, over-flow, and motor overload protection |
| Overall Dimensions | 800 mm × 630 mm × 700 mm |
| Weight | 85 kg |
| Power Supply | 1 kW, 220 V AC, 50 Hz |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMLS-1000.5 |
| Max Test Load | 1000 N |
| Force Accuracy | ±1% of reading |
| Displacement Resolution | 0.01 mm |
| Crosshead Speed Range | 0.05–300 mm/min |
| Stroke | 800 mm (excluding fixtures) |
| Dimensions (L×W×H) | 435 × 275 × 1700 mm |
| Power Supply | 220 V, 50 Hz |
| Compliance | GB/T 6344–2008, GB/T 10808–2006, ISO 1798:1997 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCPMFY-A |
| Price | USD 2,200 (FOB Beijing) |
| Compliance | GB/T 26392–2011, ASTM D3574–08 Section 12 |
| Test Principle | Controlled indentation–hold–recovery cycle with laser-displacement monitoring and load-synchronized timing |
| Indentor | 203 mm diameter flat circular plate |
| Indentation Speed | (1000 ± 100) mm/min |
| Support Plate | Perforated (6.5 mm holes, 20 mm pitch) |
| Specimen Dimensions | 380 × 380 × 100 mm |
| Initial Preload | 4.5 N |
| Indentation Depth | 75% of initial thickness |
| Hold Duration | 60 s |
| Recovery Threshold | Re-engagement of 4.5 N preload force |
| Thickness Measurement | Integrated laser displacement sensor (±1 mm accuracy) |
| Time Resolution | 0.01 s |
| Load Cell Range | 1000 N |
| Control Interface | 7-inch industrial capacitive touchscreen (HMI) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | PMLS1000.3 |
| Price | USD 2,200 (approx.) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCMDR-300 |
| Price | USD 1,750 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCDRD-5KV |
| Voltage Range | 0–5 kV DC |
| Compliance | GB/T 13542.2–2009, IEC 60674-2:1988 |
| Application | Electrical Weak Point Detection in Polymer Insulating Films |
| Control System | PC-based Closed-loop Voltage Ramp & Real-time Data Acquisition |
| Sample Handling | Motorized Unwind/Re-wind with Adjustable Linear Speed |
| Output Metrics | Weak Point Count per m², Weak Line Count, Automatic Zero Return & Statistical Summary |
| [Brand | Guance |
|---|---|
| Model | GEST-126b |
| Origin | Beijing, China |
| Compliance | YS/T 587.6–2006, GB/T 24525–2009, GB/T 24521–2009, GB/T 3782–2016 |
| Resistivity Range | 10⁻⁶–10⁵ Ω·cm |
| Voltage Range | 2 mV–2 V (4½-digit display) |
| Current Output | 10 μA–10 A (8 ranges) |
| Resolution | 10⁻⁸ Ω·cm |
| Measurement Accuracy | ±(0.5% reading + 2 digits) for current and voltage] |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YSRB-300.5 |
| Price | USD 1,800 (approx.) |
| Heating Method | Air-bath |
| Test Channels | 3 |
| Temperature Range | Ambient to 300 °C |
| Temp. Stability | ±2 °C |
| Heating Rate | 50±3 °C/h or 10±2 °C/12 min |
| Temp. Resolution | 0.1 °C |
| Deformation Resolution | 0.002 mm |
| Specimen Dimensions | 50×50×50 mm or 40×40×20 mm |
| Platen Size | 50×50 mm (×3) |
| Recommended Load Range | 0–1 MPa |
| Chamber Internal Dimensions | 350×400×400 mm |
| Lever Compression Ratio | 1:32 |
| Loading Modes | Lever-weighted compression / Direct-weighted bending |
| Load Mass Set | 15 kg total (distributed across three independent test stations) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | PMLS-1000 |
| Price | USD 2,800 (FOB Beijing) |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Model | GCRBWK-300A4 |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.5 °C |
| Heating Rates | 50 °C/h or 120 °C/h (adjustable between 50–120 °C/h) |
| Temperature Resolution | 0.001 °C |
| Deformation Measurement Range | 0–10 mm |
| Deformation Accuracy | ±0.005 mm |
| Deformation Resolution | 0.001 mm |
| Number of Test Stations | 4 |
| Support Span Options | 64 mm or 100 mm |
| Thermal Expansion Coefficient of Test Frame | <0.005 /100 °C |
| Temperature Sensing Points | 4 |
| Heating Power | 4000 W |
| Bath Medium | Methyl Silicone Oil or Transformer Oil |
| Cooling Method | Natural cooling above 150 °C |
| Control Architecture | Distributed MCU + PC System |
| Safety Protections | Dual hardware/software temperature limit switches, auto-stop on test completion, administrator access control |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZKTT-Id |
| Rated Power | 1 kW |
| Rated Voltage | 220 V / 50 Hz |
| Pressure Sensor Range | 0–1 MPa and −100 kPa to 0 |
| Sample Dimensions | Ø50 mm × 20 mm |
| Measurement Range | 0.01 × 10⁻⁹ m² to 20 × 10⁻⁹ m² |
| Maximum Flow Rate | 25 L/min |
| Equipment Dimensions | 800 mm (L) × 620 mm (W) × 670 mm (H) |
| Net Weight | 100 kg |
| Compliance | YS/T 63.10–2012, ISO 15906:2007 (MOD), GB/T 26297.3 |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCZWTQ-A |
| Price | Upon Request |
| Standard Compliance | ISO 4638:1984, GB/T 10655, GB/T 5453–1997, AQ 1088–2011, ASTM D3574–2005 |
| Display & Control | 10-inch industrial touchscreen HMI |
| Test Method | Constant-pressure differential method |
| Pressure Differential Sensor Range | 0–1000 Pa |
| Flow Sensor Range | 0–100 L/min |
| Sample Aperture Diameter | φ100 mm |
| Test Chamber Material | 4 mm thick brushed 304 stainless steel weldment |
| Safety Protections | Over-temperature, over-pressure, over-flow, and overload protection |
| Dimensions (L×W×H) | 400 × 600 × 1200 mm |
| Weight | 85 kg |
| Power Rating | 1 kW |
| Test Duration | ≤10 s per measurement |
| Data Output | Differential pressure, volumetric flow rate, air permeability coefficient (mm/s or mL/cm²·s), arithmetic mean of multiple tests |
| Operating Modes | Fully automatic test cycle or manual termination |
| Sensor Switching | Dual-range differential pressure sensors with auto-switching logic |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMTQ-A |
| Price | USD 2,650 (FOB Beijing) |
| Compliance | ISO 4638:1984, GB/T 10655, AQ 1088-2011, ASTM D3574-2005 |
| Touchscreen Interface | 7-inch capacitive LCD |
| Test Duration | ≤10 s per sample |
| Vacuum Pump | 1.3 m³/h (4.8 L/s), ultimate vacuum 5 × 10² Pa |
| Flow Range | 0–50 L/min |
| Differential Pressure Sensors | Dual-range (0–400 Pa and 0–100 Pa) |
| Test Chamber Dimensions | 100 mm × 100 mm × 104 mm (L×W×H) |
| Specimen Size | 102 mm × 102 mm, thickness 0–100 mm |
| Air Permeability Range | 0–999.9 × 10⁻¹⁰ m² |
| Temperature Range | −40 °C to +80 °C |
| Chamber Material | 4 mm 304 brushed stainless steel |
| Safety Protections | Over-temperature, over-pressure, over-flow, and motor overload protection |
| Dimensions (W×D×H) | 800 mm × 630 mm × 700 mm |
| Weight | 85 kg |
| Power Rating | 1 kW |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GCDRD-1500 |
| Pricing | Upon Request |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMLS-1000.4 |
| Max Test Force | 1000 N |
| Force Accuracy | ±1% of reading |
| Displacement Resolution | 0.01 mm |
| Displacement Accuracy | ±1% of reading |
| Crosshead Speed Range | 0.05–300 mm/min |
| Speed Accuracy | ±1% |
| Stroke | 800 mm (excluding fixtures) |
| Dimensions (L×W×H) | 435 × 275 × 1700 mm |
| Power Supply | 220 V, 50 Hz |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GEST-20042 |
| Price | USD 1,400 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMTQ-A.4 |
| Price | USD 2,050 (FOB Beijing) |
| Vacuum Pump | 1.3 m³/h (4.8 L/s), Ultimate Vacuum: 5 × 10² Pa |
| Flow Sensor Range | 0–50 L/min |
| Differential Pressure Sensors | 0–400 Pa & 0–100 Pa (auto-switching) |
| Test Chamber Dimensions | 100 mm × 100 mm × 104 mm (L×W×D) |
| Specimen Size | 102 mm × 102 mm, Thickness: 0–100 mm |
| Air Permeability Range | 0–999.9 × 10⁻¹⁰ m² |
| Temperature Sensor | −40 °C to +80 °C |
| Chamber Material | 4 mm 304 brushed stainless steel |
| Safety Protections | Over-temperature, over-pressure, over-flow, and motor overload protection |
| Overall Dimensions | 800 mm × 630 mm × 700 mm (L×W×H) |
| Weight | 85 kg |
| Power Rating | 1 kW |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZKTT-I |
| Price | USD 950 (FOB Beijing) |
| Rated Power | 1 kW |
| Rated Voltage | 220 V / 50 Hz |
| Pressure Sensor Range | 0–1 MPa and −100 kPa–0 |
| Sample Dimensions | Ø50 mm × 20 mm |
| Measurement Range | 0.01 × 10⁻⁹ m² to 20 × 10⁻⁹ m² |
| Maximum Flow Rate | 25 L/min |
| Equipment Dimensions | 800 mm (L) × 620 mm (W) × 670 mm (H) |
| Weight | 100 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCYSBX-1 |
| Price | USD 3,500 (FOB Beijing) |
| Standard Compliance | GB/T 6669–2008 / ISO 1856:2000 |
| Specimen Dimensions | 50 mm × 50 mm × 25 mm |
| Capacity | 20 specimens per test cycle |
| Compression Plates | Parallel stainless-steel plates with adjustable spacing and clamping mechanism |
| Calibration Spacers | 12.5 mm (50% compression), 6.25 mm (75%), and 2.5 mm (90%) — 4 pieces each |
| Glass Cover Slides | 55 mm × 55 mm × 1.5 mm |
| Temperature-Controlled Oven Range | 0–300 °C |
| Oven Temperature Accuracy | ±1 °C |
| Oven Power Supply | 220 V AC, 50 Hz |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | PMYX-2000A2 |
| Maximum Load Capacity | 2000 N |
| Force Resolution | 0.01 N |
| Force Accuracy | <1% FS |
| Indenter Diameter | 200 mm (customizable) |
| Effective Travel Stroke | 400 mm |
| Default Crosshead Speed | 100 mm/min (adjustable from 1–300 mm/min) |
| Touchscreen Interface | 7-inch HMI |
| Power Supply | 220 V / 50 Hz |
| Dimensions (L×W×H) | 550 × 400 × 1200 mm |
| Weight | 150 kg |
| Compliant Standards | GB/T 10807-2006, GB/T 12825-2003, GB/T 18942.1-2003, ASTM D3574, GB/T 26392-2011 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YSRB-300.4 |
| Price | USD 1,550 (approx.) |
| Heating Method | Air-bath |
| Test Channels | 3 |
| Temperature Range | Ambient to 300 °C |
| Temp. Stability | ±2 °C |
| Heating Rate | 50±3 °C/h or 10±2 °C/12 min |
| Temp. Resolution | 0.1 °C |
| Deformation Resolution | 0.002 mm |
| Specimen Dimensions | 50×50×50 mm or 40×40×20 mm |
| Platen Size | 50×50 mm (×3) |
| Recommended Load Range | 0–1 MPa |
| Chamber Internal Dimensions | 350×400×400 mm |
| Lever Compression Ratio | 1:32 |
| Loading Configuration | Lever-weighted compression + direct-weighted bending |
| Deformation Sensor | High-precision optical grating micrometer |
Show next