Empowering Scientific Discovery

Beijing Laiboruijie Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
ModelDW-40L276
Temperature Range–20 °C to –40 °C
Effective Volume276 L
Internal Dimensions (W×D×H)506 mm × 505 mm × 1205 mm
External Dimensions (W×D×H)717 mm × 710 mm × 1745 mm
Net/Gross Weight106 kg / 125 kg
Power Supply220 V / 50 Hz
CompressorImported High-Efficiency Compressor
Fan MotorEBM Premium AC Fan Motor
InsulationHigh-Density Polyurethane Foam with Microcellular Foaming Technology
RefrigerantEco-Friendly R404A or Equivalent Non-Ozone-Depleting Refrigerant
Door SealDual-Gasket Sealed Structure
Control SystemMicroprocessor-Based Digital Temperature Controller with Adjustable Setpoint (–10 °C to –40 °C)
Alarm FunctionsHigh/Low Temperature, Door Open, Sensor Fault, Power Failure, Low Battery (for Backup Memory), Audible & Visual Alerts
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
ModelCX-1020
Capacity1020 L
Temperature Range2–8 °C
Power Supply220 V / 50 Hz
Dimensions (W×D×H)1288 × 888 × 1936 mm
Power Consumption450 W
Net Weight186 kg
Gross Weight225 kg
RefrigerantR134a
Control Accuracy±0.1 °C
Interior MaterialStainless Steel
Door TypeDouble-layer Low-E Tempered Glass with Anti-condensation Heating Strip
Safety FeaturesPassword-protected Controller, High/Low Temperature Alarms, Sensor Fault Detection, Delayed Start & Compressor Protection Interval
Standard ComplianceGB/T 20154–2014 (Chromatography Refrigerators), IEC 61000-6-3 EMC, GB 4706.1 Safety of Household and Similar Electrical Appliances
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
OriginShandong, China
ModelDW-25W322
Temperature Range–10 °C to –25 °C
Net Capacity322 L
Internal Dimensions (W×D×H)1097 × 450 × 707 mm
External Dimensions (W×D×H)1219 × 625 × 920 mm
Power Supply220 V / 50 Hz
Refrigerant & InsulationCFC-free refrigerant and polyurethane foam insulation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
ModelYCD-265
Temperature Range (Refrigeration Compartment)2–8 °C
Temperature Range (Freezing Compartment)–15 to –26 °C
Net Capacity265 L
Internal Dimensions (W×D×H)460×480×720 mm (refrigeration section)
External Dimensions (W×D×H)575×641×1687 mm
Power Supply220 V / 50 Hz
Control SystemMicroprocessor-based dual-zone digital display
Cooling MethodForced-air (refrigeration), static cooling (freezing)
Door LockMechanical safety lock
InsulationCFC-free polyurethane foam
RefrigerantR600a (isobutane)
ComplianceDesigned per GB/T 20154–2014 (Chinese national standard for medical refrigerators), suitable for GLP-aligned storage environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
ModelXC-120
Temperature Range4°C ±1°C
Effective Volume120 L
Internal Dimensions (W×D×H)485×449×550 mm
External Dimensions (W×D×H)598×618×1110 mm
Power Supply~220 V / 50 Hz
Shelving Configuration2 stainless steel shelves + 4 plastic blood baskets
Sensor Count6 high-precision NTC sensors (including dual simulated-blood core temperature probes)
Alarm TypesAudible buzzer, visual LED flash, remote alarm output
OptionalIntegrated temperature data logger with print capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
OriginShandong, China
ModelDW-86L937TBS
TypeUpright Ultra-Low Temperature Freezer
Effective Volume937 L
Internal Dimensions (W×D×H)1020 × 725 × 1258 mm
External Dimensions (W×D×H)1360 × 1070 × 1960 mm
Temperature Range−40 °C to −86 °C
Power Supply220 V AC, 50 Hz
Rated Power2 kW
CompressorDual SECOP hydrocarbon-based inverter compressors
InsulationCFC-free polyurethane foam, 130 mm thick
Noise Level< 60 dB(A)
Cooling Rate≤ 6 h (from 25 °C ambient to −80 °C)
Data Logging10-year internal storage via USB export
Connectivity4G Cat.4 & Wi-Fi
ComplianceDesigned for GLP/GMP-aligned biobanking environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
ModelXC-310
Temperature Range4 ± 1 °C
Effective Volume310 L
Internal Dimensions (W×D×H)565 × 454 × 1198 mm
External Dimensions (W×D×H)660 × 644 × 1960 mm
Power Supply220 V AC, 50 Hz
Sensor Configuration6 high-precision NTC sensors (including dual simulated-blood core temperature probes)
Alarm TypesAudible buzzer, visual LED flash, remote alarm output
OptionalIntegrated temperature data logger with print capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
OriginShandong, China
ModelDW-86L348
Effective Volume348 L
Internal Dimensions (W×D×H)804 × 593 × 629 mm
External Dimensions (W×D×H)540 × 480 × 574 mm
Power Supply220 V / 50 Hz
Rated Power900 W
Temperature Range–40 °C to –86 °C
Cabinet TypeUpright
Refrigeration SystemOptimized cascade refrigeration with dual-stage compressors
InsulationHigh-density polyurethane foam (≥120 mm thickness), fluorine-free blowing agent
Door ConfigurationDual-layer insulated door with multi-point magnetic seal
Safety FeaturesDual-stage temperature alarm, voltage fluctuation compensation, condenser clogging detection, sensor fault monitoring, battery-low warning, remote alarm interface
ComplianceDesigned for GLP-compliant environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
OriginShandong, China
ModelYC-200
Refrigeration Temperature Range2–8 °C
Effective Capacity200 L
Internal Dimensions (W×D×H)490 × 400 × 1016 mm
External Dimensions (W×D×H)560 × 578 × 1522 mm
Voltage/Frequency~220 V / 50 Hz
Net Weight54 kg
Gross Weight61 kg
Control Accuracy±0.1 °C
Cooling SystemForced-air convection with high-efficiency compressor and EBM fan motor
Safety AlarmsHigh/low temperature, door open, power failure, sensor fault
Door TypeSingle transparent double-glazed coated glass door with anti-condensation heating strip
Shelving3 adjustable wire shelves + optional baskets
ComplianceDesigned for GLP-compliant storage per ISO 13485 and WHO Technical Report Series No. 961 (2011), Annex 9
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
OriginShandong, China
ModelDW-60W238
Temperature Range–30 °C to –60 °C
Effective Volume238 L
Internal Dimensions (W×D×H)943 × 494 × 580 mm
External Dimensions (W×D×H)1122 × 755 × 840 mm
RefrigerantEco-friendly HFC-free
CompressorImported high-efficiency cascade compressor
Control SystemMicroprocessor-based digital temperature controller with dual-sensor monitoring
Alarm TypesAudible buzzer, visual LED alert, remote alarm output
InsulationHigh-density polyurethane foam, ≥120 mm thick
Power Supply220 V AC, 50 Hz
Safety FeaturesPassword-protected keypad, door lock, voltage compensation, compressor delay start, automatic defrost cycle management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
ModelDW-40W300
Temperature Range–20 °C to –40 °C
Capacity300 L
Voltage/Frequency220 V / 50 Hz
External Dimensions (W×D×H)1154 × 710 × 838 mm
Internal Dimensions (W×D×H)985 × 504 × 661 mm
Net Weight64 kg
Gross Weight74 kg
Cabinet TypeUpright
Inner LinerAnodized Aluminum Step-Type
InsulationHigh-Density Polyurethane Foam with Microcellular Foaming Technology
RefrigerantR134a (CFC-free)
CompressorImported High-Efficiency Hermetic Compressor
Fan MotorEBM Precision AC Axial Fan
Climate ClassN (10 °C to 32 °C Ambient)
Control SystemMicroprocessor-Based Digital Temperature Controller with Adjustable Setpoint (–10 °C to –40 °C)
Alarm FunctionsDual-Stage High/Low Temperature Alarm, Sensor Fault Detection, Audible Beeper + Visual LED Alert
Safety FeaturesKey Lock, Delayed Start, Compressor Protection Cycle, Drain Hole in Floor Pan
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAsylum Research
OriginBeijing, China
ModelDKT200-2A
Temperature RangeAmbient +5°C to 150°C
Temperature Stability≤ ±0.5°C (40–100°C), ≤ ±1.0°C (100–150°C)
Module Temperature Uniformity≤ ±0.5°C
Display Resolution0.1°C
Max Timer Setting99h 59min
Max Power Consumption600 W
Dimensions (W×D×H)260 × 290 × 95 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAsylum Research
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryRodent Metabolic Monitoring System
ModelMice Metabolic Cage
Dimensions (L×W×H)210 × 210 × 400 mm
MaterialPolycarbonate (PC), autoclavable at 120°C
Urine Collection Capacity15 mL
Water Bottle Capacity880 mL
Grid ApertureØ1 mm
ComplianceISO 9001-certified manufacturing process
SterilizationCompatible with steam autoclaving (120°C, 20 min)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAsylum Research
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryLaboratory Animal Housing
ModelG-12
Unit PriceUSD 1,280
Cage Layout3 columns × 4 rows = 12 individual units
Single Cage Dimensions500 × 400 × 260 mm (L×W×H)
Full Rack Dimensions2000 × 650 × 1720 mm (L×W×H)
MaterialAISI 304 stainless steel
Components IncludedFeed hopper, gravity-fed water bottle with stainless steel sipper tube, removable waste tray, integrated water reservoir
ComplianceDesigned to meet NIH Guide for the Care and Use of Laboratory Animals, AAALAC International housing standards, and ISO 55000-aligned facility maintenance protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAsylum Research
OriginBeijing, China
ModelES-60
Instrument TypeAir-jacketed incubated orbital shaker
Timer Range0–99 h 59 min
Oscillation Speed50–300 rpm
Amplitude20 mm
Temperature RangeAmbient +5°C to 60°C
Number of Platforms1
Temperature Display Accuracy≤ ±0.1°C
Temperature Stability (@37°C)≤ ±0.3°C
Power SupplyAC 110/220 V, 250 W
Dimensions (W×D×H)420 × 360 × 320 mm
Motor TypeBrushless DC motor
Fan SpeedAdjustable
Safety FeaturesIndependent overtemperature cutoff, lid-interlock shutdown, audible end-of-program alarm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelAMR-100
Function TypeMultimode
Automation LevelFully Automated
Measurement PrincipleFilter-Based Absorbance Detection
Wavelength Range400–750 nm
Absorbance Range0.000–4.000 Abs
Linearity±1% (0–2.000 Abs), ±2% (2.000–4.000 Abs)
Accuracy (405 nm)±1% (0–3 Abs), ±2% (3–4 Abs)
Precision (CV, 405 nm)≤0.2% (0–3 Abs), ≤1.0% (3–4 Abs)
Detection Speed<6 s/96-well (single wavelength), <9 s/96-well (dual wavelength)
Optical System8-channel high-precision fiber-optic path with automatic well-centering
Filter Capacity8-position filter wheel (standard filters: 405, 450, 490/492, 630 nm)
Display7-inch color TFT touchscreen (800 × 480 px)
Plate CompatibilityStandard 96-well microplates and strip formats
Onboard Storage200 protocols + 100,000 assay results (96-well format)
Interfaces3 × USB (PC, printer, USB drive), Wi-Fi
Power SupplyAC 100–240 V, 50–60 Hz
Lamp TypeLong-life halogen lamp (≥4000 h)
Built-in DiagnosticsReal-time self-check of optical path, mechanical positioning, plate loading, and filter alignment
Shaking FunctionAdjustable speed and duration
Safety MechanismMotorized door with obstacle-detection reversal
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRTECH (Suzhou Antai)
OriginJiangsu, China
Instrument TypeClass II, Type B2 (Total Exhaust) Biosafety Cabinet
External Dimensions (L×W×H)1500 × 790 × 2050 mm
Internal Work Area Dimensions (L×W×H)1270 × 600 × 620 mm
HEPA Filter Efficiency≥99.995% @ 0.3 µm
ULPA Filter Efficiency≥99.9995% @ 0.12 µm
Downflow Velocity0.35 m/s
Inflow Velocity0.55 m/s
Noise Level≤65 dB(A)
Power SupplyAC 220 V, 1φ, 50 Hz
Rated Power1.65 kW
Weight270 kg
Air Cleanliness ClassISO 4 (equivalent to Federal Standard 209E Class 10)
Personnel Protection≤5 CFU/plate (slit sampler)
Product Protection≤2 CFU/plate
Cross-Contamination Protection≤5 CFU/plate (impact sampler), ≤5 CFU/plate (slit sampler)
Lighting24.5 W LED, ≥900 lx uniformity
UV Lamp25 W, germicidal
Exhaust DirectionTop-mounted ducted exhaust
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelAuto-Pure20
Instrument TypeMagnetic Bead-Based Extraction
Automation LevelDedicated Fully Automatic
Sample Throughput per Run1–20 samples
Sample Volume Range20–1000 µL
Processing Time per Batch15–45 minutes
Magnetic Rod Count20
Magnetic Bead Recovery Rate>95%
Inter-Well CV<3%
Lysis & Elution Temperature RangeAmbient to 90 °C
Touchscreen Interface7-inch high-resolution color LCD
Preloaded Protocols>100 (15 factory-default)
UV SterilizationIntegrated
Connectivity4× USB-A, 1× USB-B, Ethernet, Wi-Fi, SD card slot
Power SupplyAC 110–220 V, 50/60 Hz
Dimensions440 × 467 × 453 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelAuto-Pure32
Instrument TypeMagnetic Bead-Based Extraction
Automation LevelDedicated Fully Automatic
Sample Throughput1–32 samples per run
Sample Volume Range20–1000 µL
Processing Time per Run15–40 min
Magnetic Rod Count32
Magnetic Bead Recovery Rate>95%
Inter-Well CV<3%
Lysis & Elution Temperature RangeAmbient to 90 °C
Touchscreen Interface7-inch high-resolution color LCD
Preloaded Protocols≥100 (15 factory-default)
UV SterilizationIntegrated
Connectivity4× USB-A, 1× USB-B, Ethernet, Wi-Fi, SD card slot
Power SupplyAC 110–220 V, 50/60 Hz
Dimensions440 × 467 × 453 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRTECH (Suzhou Jintan Airtech)
OriginJiangsu, China
ModelBSC-1600IIA2
Instrument TypeClass II, Type A2 Biological Safety Cabinet
External Dimensions (L×W×H)1800 × 790 × 2050 mm
Internal Work Area Dimensions (L×W×H)1600 × 600 × 620 mm
Filtration EfficiencyHEPA ≥99.995% @ 0.3 µm
Downflow Velocity0.35 m/s
Inflow Velocity0.55 m/s
Noise Level≤62 dB(A)
Lighting Intensity≥800 lx
Power Consumption2.0 kW
Weight360 kg
ComplianceYY 0569–2011 (China), NSF/ANSI 49–2022 (USA)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRTECH (Suzhou Antai)
OriginJiangsu, China
Instrument TypeVertical Laminar Flow Clean Bench
Cleanliness ClassISO 5 (equivalent to US FED STD 209E Class 100)
Noise Level≤62 dB(A)
User ConfigurationDual-operator, dual-sided (SW-CJ-2F) or dual-operator, single-sided (SW-CJ-2FD)
Airflow PatternVertical unidirectional laminar flow
Average Air Velocity≥0.3 m/s (adjustable)
Illumination≥300 lx
Power SupplyAC 220 V, 1φ, 50 Hz
Rated Power500 W
Weight170 kg
Work Area Dimensions (W×D×H)1360×690×520 mm (SW-CJ-2F), 1360×690×520 mm (SW-CJ-2FD)
Overall Dimensions (W×D×H)1500×750×1600 mm (SW-CJ-2F), 1500×730×1600 mm (SW-CJ-2FD)
HEPA Filter Specification610×610×50 mm ×2 units
Settling Microbial Count≤0.5 CFU/plate·0.5 h
Pre-filterQuick-access washable design
Control InterfaceDigital display with touch keys
Safety InterlockUV lamp and lighting circuit interlocked
UV Timer FunctionProgrammable on/off scheduling
Runtime MonitoringReal-time cumulative operating hours for fan, UV lamp, and HEPA filter
ConstructionStainless steel monolithic work surface
MobilityLocking omnidirectional casters
Added to wishlistRemoved from wishlist 0
Add to compare
[Brand3P (Germany)
OriginJiangsu, China
ModelDZP300CO₂
Instrument TypeRefrigerated/Heated CO₂ Orbital Shaker Incubator
Stacking Layers1–3 independent layers
Temperature Range4–60 °C (at 25 °C ambient)
CO₂ Range0–20% (±0.1% control accuracy)
Humidity RangeAmbient to 95% RH
Orbital Speed10–300 rpm (±1 rpm accuracy)
Orbit Diameter26 mm or 50 mm selectable
Timer Range0–999 h 59 min
Shelf Dimensions1010 × 580 mm
Internal Volume per Layer283 L
Power SupplyAC 220 V ±10%, 50–60 Hz
Drive SystemThree-axis orbital drive with brushless motor & precision forged steel eccentric cam
Chamber MaterialSUS304 brushed stainless steel
Control Interface7-inch true-color capacitive touchscreen
ComplianceDesigned for GLP-compliant cell culture workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDS
OriginBeijing, China
ModelUVJLY-1
UV Wavelength254 nm (optional 312 nm / 365 nm lamps)
Exposure Time Range0–999.9 min
Exposure Energy Range0–99.99 J
Chamber Dimensions340 × 260 × 150 mm
Lamp ConfigurationFive 10 W UV-C lamps (254 nm)
Power Input60 W
DisplayBacklit LCD with Chinese interface
Control InterfaceTouch-sensitive keypad
Chamber MaterialStainless steel
UV Shielding WindowIntegrated safety viewport
Data RetentionNon-volatile memory for settings on power-off
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDS
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginDomestic (China)
ModelSH1000
Automation LevelSemi-Automatic
Instrument TypeChromogenic In Situ Hybridization (CISH) System
Temperature RangeRoom Temperature +5 °C to 100 °C
Sample Capacity12 microscope slides
Power Consumption350 W
Dimensions (W×D×H)440 mm × 220 mm × 120 mm
Weight4.5 kg
Humidity ControlNot integrated
Temperature Accuracy≤ ±0.5 °C
Temperature Uniformity≤ ±0.5 °C
Heating Time (37 °C → 95 °C)≤2 min
Cooling Time (95 °C → 45 °C)≤6 min
Timer Range1 min – 99 h 59 min
Program Storage300 user-defined protocols
Operating ModesDenaturation & Hybridization, Hybridization-only, Multi-step Protocol Execution