- All
- Favorite
- Popular
- Most rated
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY92-IIDN |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 900 W (touch-key continuous adjustment) |
| Pulse Mode | On-time 0.1–99.9 s / Off-time 0.1–99.9 s / Total Duration 0.1–99 min |
| Duty Cycle | 0.1–99.9% |
| Temperature Monitoring Range | 0–100 °C |
| Standard Probe Diameter | Φ6 mm |
| Optional Probes | Φ2, Φ3, Φ8, Φ10, Φ15 mm |
| Sample Volume Capacity | 0.2–600 mL |
| Input Voltage | 220/110 V, 50/60 Hz |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Microscope Type | Upright Biological Microscope |
| Model | E200 |
| Optical System | CFI60 Infinity-Corrected |
| Magnification Range | 40×–1000× |
| Eyepiece Tube | E2-TB Binocular (hinged, 30° inclination) or E2-TF Trinocular (30° inclination, 360° rotation, interpupillary distance 47–75 mm) |
| Eyepieces | CFI E10×/20 mm (field number 20 mm), optional CFI 15×/12 mm |
| Objectives | CFI E Plan Achromat 4× (NA 0.10), 10× (NA 0.25), 40× (NA 0.65), 100× oil (NA 1.25) |
| Nosepiece | Internal quadruple revolving nosepiece |
| Stage | Rectangular mechanical stage (216 × 150 mm), X–Y travel 78 × 54 mm, low-position coaxial controls, auto-return focusing mechanism |
| Condenser | E2 Abbe condenser (NA 1.25) with iris diaphragm and objective position markers |
| Illumination | 6 V / 20 W halogen lamp, centerable and height-adjustable |
| Focus Mechanism | Coarse focus (37.7 mm per revolution), fine focus (0.2 mm per revolution, 2 µm graduation), adjustable coarse torque, built-in stage stop for high-magnification protection |
| Compliance | Designed for ISO 10993-5 biocompatibility of user-contact components |
| Origin | Jiangsu, China |
|---|---|
| Cabinet Type | Class II, Type B2 (Total Exhaust) |
| External Dimensions (L×W×H) | 1500 × 790 × 2050 mm |
| Internal Work Area (L×W×H) | 1300 × 600 × 620 mm |
| Filter Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity | 0.35 m/s |
| Inflow Velocity | 0.35 m/s |
| Noise Level | ≤58 dB(A) |
| Power Supply | AC 220 V, 1Φ, 50 Hz |
| Max. Rated Power | 2.1 kVA |
| Weight | 300 kg |
| Lighting | 36 W × 2 fluorescent lamps |
| UV Lamp | 20 W × 1 |
| Illuminance | ≥800 lx |
| Biological Protection Performance | ≤10 CFU/plate (impact sampler), ≤5 CFU/plate (slit sampler) |
| Product Protection | ≤5 CFU/plate |
| Cross-contamination Protection | ≤2 CFU/plate |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DZ2000 |
| Price | USD 2,650 (FOB) |
| Optical System | UCIS Infinity-Corrected, Parfocal, Positive-Image Path |
| Magnification Range | 40×–400× (expandable to 960× with optional 60× objective) |
| Eyepieces | Widefield PL10×/20 mm (high-eye-point, reticle-compatible) |
| Objectives | Infinity Long Working Distance (LWD) Plan Achromatic: 4×, 10×, 20×, 40× |
| Phase Contrast | 10×, 20×, 40× LWD |
| Condenser | N.A. 0.70, WD 72 mm / 120 mm, removable, with aperture diaphragm |
| Focusing | Coaxial coarse/fine focus |
| Stage | Mechanical XY stage, 80 × 50 mm travel |
| Illumination | 6 V / 30 W halogen lamp with aspheric collector lens |
| Fluorescence Module | Rotating filter turret for dual-band (B/G) or quad-band (UV/V/B/G) excitation |
| Camera Port | Trinocular port with 80:20 beam splitter ratio |
| Compliance | Designed per ISO 10934-1 (Microscopes — Nomenclature of components), IEC 61010-1 (Safety requirements for electrical equipment), and GLP-aligned documentation architecture |
| Brand | TECAN |
|---|---|
| Origin | Switzerland |
| Model | HydroFlex |
| Instrument Type | Multifunctional Microplate Washer |
| Wash Head Configuration | 8-channel or dual 8-channel (16-channel equivalent) |
| Wash Fluid Channels | 1, 2, or 4 selectable |
| Soaking Time | Programmable |
| Wash Cycles | 1–10 |
| Residual Volume per Well | ≤1.8 µL |
| Orbital Shaking | Linear, 3 adjustable speeds |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZK-96 |
| Price Range | USD 28,000 – 42,500 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automated Platform |
| Throughput | 1–96 Samples per Run |
| Sample Volume Range | 30 µL – 1000 µL |
| Processing Time per Batch | 20–60 min |
| Magnetic Bead Recovery Efficiency | >98% |
| Heating Temperature Range (Lysis/Elution) | Ambient to 110 °C |
| Oscillation | Multi-Speed & Multi-Amplitude Programmable |
| Air Filtration | Dual HEPA + UV-C Sterilization |
| Control Interface | 7-inch Capacitive Touchscreen (Chinese UI) |
| Connectivity | Wi-Fi Enabled |
| Remote Monitoring | Mobile App Supported |
| Dimensions (W×D×H) | 780 × 440 × 500 mm |
| Weight | 42 kg |
| Power Supply | AC 110–220 V, 50/60 Hz |
| Operating Environment | 10–40 °C, <80% RH (non-condensing) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Product Category | Domestic |
| Model | HYG-A |
| Price | USD 3,500 (approx.) |
| Instrument Type | Air-Bath Constant-Temperature Orbital Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–280 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 5°C to 60°C (at ambient 25°C) |
| Temperature Accuracy | ±0.1°C |
| Temperature Uniformity | ±0.5°C |
| Shelf Count | 2-tier |
| Tray Dimensions | 710 × 450 mm |
| Capacity per Shelf | 15 × 1000 mL or 24 × 500 mL or 35 × 250 mL Erlenmeyer flasks |
| Display | LED digital |
| Input Power | 1200 W |
| Overall Dimensions (W×D×H) | 900 × 750 × 1530 mm |
| Net Weight | 180 kg |
| Power Supply | 220 V, 50 Hz |
| Interior Lighting | 20 W |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Laboratory Animal Housing Equipment |
| Model | A-Type/16 |
| Dimensions | 1350 × 400 × 1500 mm (W × D × H) |
| Cage Capacity | 16 cages (4 tiers × 4 cages per tier) |
| Cage Material | AISI 304 stainless steel |
| Water Bottles | 500 mL, stainless steel-mounted |
| Feeders | AISI 304 stainless steel, 16 units |
| Waste Trays | Polypropylene (PP), 16 units |
| Base Frame | AISI 304 stainless steel with four swivel casters |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | F50 |
| Function Type | Multimode |
| Automation Level | Semi-Automated |
| Detection Method | Absorbance (Photometric) |
| Wavelength Range | 400–750 nm |
| Absorbance Range | 0–4.00 OD |
| Linearity Range | 0.000–2.000 Abs |
| Optical Channels | 8-Channel Simultaneous Detection |
| Wavelength Accuracy | ±2 nm |
| Absorbance Resolution | 0.0001 OD |
| Read Speed | <10 sec per 96-well plate (single wavelength) |
| Light Source | High-Stability LED Array |
| Plate Formats | 6–384-well microplates, cuvettes (optional) |
| Compliance | ISO 13485:2016, FDA 21 CFR Part 11 (with Magellan Tracker), EU IVD Directive 98/79/EC, RoHS & WEEE |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MX100-4A |
| Instrument Type | Microplate Shaker |
| Timer Range | 99 h 59 min |
| Oscillation Frequency | 200–1500 rpm (standard), 300–1000 rpm (full load) |
| Oscillation Amplitude | 3 mm horizontal orbital |
| Temperature Control | Ambient only |
| Plate Capacity | 4 standard microplates (96-well, 384-well, 24-/48-well plates) |
| Dimensions | 280 × 270 × 110 mm |
| Weight | 7 kg |
| Motor Type | Brushless DC motor |
| Display | LED digital display |
| Alarm | Audible end-of-program signal |
| Optional Accessory | 1.5/2.0 mL centrifuge tube holder |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DM1000 |
| Pricing | Available Upon Request |
| Brand | Hisense |
|---|---|
| Model | HBC-4L160 |
| Temperature Range | 4 ± 1 °C |
| Capacity | 160 L |
| Shelves | 4 adjustable wire shelves (3 blood bag baskets per shelf) |
| Dimensions (W×D×H) | 600 × 620 × 1600 mm |
| Net Weight | 106 kg |
| Power Supply | 220 V / 50 Hz |
| Compressor | International brand, R134a refrigerant |
| Defrosting | Automatic electric heating defrost |
| Display | High-brightness LED with real-time temperature and status indication |
| Sensors | 6 high-precision PT100 temperature sensors |
| Alarm Functions | High/low temperature, door open, power failure (≥48 h backup), sensor fault |
| Insulation | Microcellular polyurethane foam with uniform cell structure |
| Door | Dual inner doors + tempered glass observation window with anti-condensation heating |
| Safety | Independent mechanical lock, voltage range 187–242 V, low-noise operation (<42 dB(A)), four swivel casters, external temperature monitoring port |
| Compliance | Designed to meet ISO 13485, WHO PQS, and GB/T 28003–2011 requirements for blood storage equipment |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Wellwash |
| Instrument Type | Multifunctional Microplate Washer |
| Wash Head Configuration | 8-channel or 12-channel |
| Rinse Head Design | Single |
| Wash Solution Channels | 1 |
| Soak Time Range | 0–10 min |
| Wash Cycles | 1 |
| Residual Volume per Well | <1.5 µL |
| Plate Shaking Function | Yes |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | UVJLY-1 |
| Price | ¥12,800 |
| Instrument Type | Benchtop |
| Wavelength Options | 254 nm (standard), optional 312 nm and 365 nm |
| UV Lamp Configuration | Five 10 W low-pressure mercury lamps |
| Total Power Consumption | 60 W |
| Exposure Time Range | 0–999.9 min |
| Energy Dose Range | 0–99.99 J/cm² |
| Exposure Chamber Dimensions | 34 × 26 × 15 cm |
| External Dimensions | 36 × 34 × 31 cm |
| Display | Backlit Chinese LCD with non-volatile memory |
| Control Interface | Touch-sensitive keypad with UV-blocking viewing window |
| Chamber Material | Stainless steel |
| Brand | DS |
|---|---|
| Origin | Beijing, China |
| Model | BH203 |
| Microscope Type | Upright Biological Microscope |
| Head Configuration | Trinocular |
| Optical System | LIOS Infinity-Corrected Achromatic Optical System |
| Magnification Range | 40×–1600× |
| Eyepieces | Wide-field, high-eyepoint plan eyepieces (10×, FN 20 mm |
| Objectives | Infinity-corrected achromatic objectives — 4×, 10×, 40× (spring-loaded), 100× oil (spring-loaded) |
| Interpupillary Adjustment | 48–75 mm (FN 20) / 48–76 mm (FN 22) |
| Nosepiece | Internal-facing, center-locating quadruple nosepiece (quintuple optional) |
| Focus Mechanism | Coaxial coarse/fine focus — coarse travel 26 mm, fine focus graduation 2 µm per division, 0.2 mm per revolution, upper limit stop and tension adjustment |
| Stage | Mechanical stage (142 × 133 mm), precision triangular guide rails, X/Y travel 76 × 52 mm, vernier scale 0.1 mm, dual-specimen clip, steel-wire X-axis drive, adjustable upper stop to prevent objective–specimen collision |
| Condenser | Abbe condenser, NA 1.25, iris diaphragm, vertical travel 12 mm |
| Illumination | 3 W LED cold light source (100–240 V AC input), continuously variable brightness, non-heat-emitting, high CRI, >25,000 h lifetime |
| Optional Accessories | Darkfield stop, polarizing kit (polarizer + analyzer), trinocular port with C-mount adapter for CMOS/CCD cameras (1×, 0.5×, 0.35× reduction options) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SHA-C |
| Price | USD 720 (FOB) |
| Temperature Range | Ambient to 100 °C |
| Temperature Uniformity | ±0.5 °C |
| Motion Mode | Reciprocal Oscillation |
| Display | LED Digital Control Panel for Temperature and Speed |
| Brand | Hisense |
|---|---|
| Origin | Shandong, China |
| Model | HCD-25L210 |
| Type | Upright Dual-Zone Lab Refrigerator-Freezer |
| Effective Capacity | 210 L |
| Internal Dimensions (W×D×H) | 500 × 550 × 1600 mm |
| External Dimensions (W×D×H) | 545 × 596 × 1663 mm |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power Consumption | 400 W |
| Energy Consumption | ≤0.62 kW·h/24h |
| Refrigerant | Hydrocarbon (R600a) |
| Temperature Ranges | Refrigeration Zone: +2 °C to +8 °C (±1 °C setpoint accuracy) |
| Freezing Zone | −15 °C to −25 °C |
| Compliance | Medical Device Registration Certificate (Guangdong FDA, No. Yue Xie Zhu Zhun 20182221052), ISO 9001, ISO 14001, ISO 13485, OHSAS 18001 (GB/T 28001) |
| Brand | Nikon |
|---|---|
| Origin | Germany |
| Model | TS2 |
| Microscope Type | Inverted Microscope |
| Eyepiece Configuration | Trinocular |
| Optical System | CFI60 Infinity-Corrected |
| Focusing Mechanism | Coaxial Coarse/Fine Adjustment |
| Working Distance | Up to 75 mm (with LWD condenser) |
| Condenser Options | Long Working Distance (NA 0.3, WD 75 mm) and Hoffman Modulation Contrast (NA 0.4, WD 44 mm) |
| Fluorescence Capability | Optional Epi-Fluorescence Attachment (up to two filter cubes, 50 W mercury lamp) |
| Camera Port | Standard C-mount compatible port for Nikon digital cameras and third-party imaging systems |
| Ergonomic Design | 45° inclined trinocular head, 400 mm eye-point height, adjustable interpupillary distance (50–75 mm) |
| Stage Height | 195 mm above bench surface |
| Stage Clearance | 190 mm between stage and condenser |
| Phase Contrast | Equipped with Nikon ADL (Apodized Diffraction-Limited) Phase Contrast Objectives |
| Compliance | Designed for GLP-compliant documentation workflows |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BHC-1300IIA/B3 |
| Instrument Class | Class II A2 Biological Safety Cabinet (30% Exhaust) |
| External Dimensions (L×W×H) | 1500 × 815 × 2270 mm |
| Internal Work Area (L×W×H) | 1300 × 600 × 640 mm |
| Filter Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity (Center) | 0.27 m/s |
| Inflow Velocity | ≥0.5 m/s |
| Noise Level | ≤58 dB(A) |
| Power Consumption | 2.1 kW |
| Weight | 340 kg |
| Lighting | 30 W × 2 Fluorescent Lamps + 30 W UV Lamp |
| Illumination | ≥650 lx |
| Airflow Configuration | Left/Right/Top Exhaust Options |
| Certified Protection Levels | Personnel Protection (≤10 CFU/plate, impact sampler), Product Protection (≤5 CFU/plate), Cross-Contamination Protection (≤2 CFU/plate) |
| Compliance | Meets ISO 14644-1 Class 5 (ISO Class 5, formerly “100”), EN 12469:2000, and GB/T 16292–16294 (Chinese Pharmacopoeia & GMP requirements) |
| Brand | Jiayuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water Bath Constant-Temperature Orbital Shaker |
| Model | THZ-82A |
| Timing Range | 0–120 min |
| Oscillation Frequency | 0–300 rpm |
| Oscillation Amplitude | 20 mm |
| Temperature Control Range | Ambient to 100 °C |
| Number of Shelving Plates | 1 |
| Temperature Accuracy | ±0.5 °C |
| Heating Power | 1880 W |
| Input Voltage/Frequency | AC 220 V, 50 Hz |
| Internal Chamber Dimensions | 390 × 440 × 360 mm (W × D × H) |
| External Dimensions | 700 × 550 × 480 mm (W × D × H) |
| Chamber Material | Stainless Steel (SUS304) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DHZ-DA |
| Price | USD 3,750 (FOB Jiangsu) |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–280 rpm |
| Oscillation Amplitude | 26 mm |
| Temperature Range | 0–60 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Accuracy | ±0.1 °C |
| Platform Quantity | 1 |
| Platform Dimensions | 880 × 540 mm |
| Max Load Capacity | 3000 mL × 8 (Erlenmeyer flasks), or 1000 mL × 24, or 500 mL × 40, or 250 mL × 60 |
| Display | LED Digital |
| Input Power | 750 W |
| Overall Dimensions (W×D×H) | 1200 × 700 × 990 mm |
| Net Weight | 180 kg |
| Power Supply | 220 V, 50 Hz |
| Illumination | 20 W LED Interior Light |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HZQ-F100 |
| Instrument Type | Air-Bath Constant-Temperature Orbital Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–280 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 5°C to 60°C |
| Temperature Uniformity | ±0.5°C |
| Temperature Control Accuracy | ±0.1°C |
| Chamber Configuration | Dual-Shelf Vertical Design |
| Shelf Dimensions | 420 × 300 mm (per shelf) |
| Standard Load Capacity | 8 × 500 mL or 12 × 250 mL Erlenmeyer flasks (spring wire mesh tray) |
| Display | LED Digital Interface |
| Power Input | 220 V, 50 Hz |
| Rated Power | 700 W |
| Illumination | 8 W LED Interior Light |
| Overall Dimensions (W×D×H) | 600 × 530 × 1300 mm |
| Net Weight | 90 kg |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | MSC-100 |
| Timer Range | 0–99 h 59 min |
| Oscillation Speed | 300–1500 rpm |
| Orbit Diameter | 3 mm (horizontal rotation) |
| Temperature Range | 0–100 °C |
| Temperature Uniformity | ≤ ±0.3 °C |
| Temperature Stability | ±0.3 °C |
| Display Resolution | 0.1 °C |
| Cooling Rate | ≥7 °C/min (from 100 °C to 20 °C), ≥1.2 °C/min (from ambient to ambient −20 °C at 30 °C ambient) |
| Heating Time | <15 min (20 °C to 100 °C) |
| Power Consumption | 200 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 8.3 kg |
| Plate Configuration | Single interchangeable heating/cooling plate |
| Compliance | CE-marked, conforms to IEC 61010-1 for laboratory equipment safety |
| Brand | HD-Lab (HDL) |
|---|---|
| Origin | Beijing, China |
| Model | BSC-1100 II A2 |
| Cabinet Class | NSF/ANSI 49–2022 & EN 12469:2000 Compliant Class II Type A2 |
| External Dimensions (L×W×H) | 1080 × 790 × 2150 mm |
| Internal Work Area (L×W×H) | 915 × 600 × 680 mm |
| ULPA Filter Efficiency | ≥99.9995% @ 0.1–0.2 µm |
| Filter Penetration Rate | ≤0.005% |
| Inflow Velocity | ≥0.5 m/s |
| Downflow Velocity | 0.25–0.5 m/s |
| Noise Level | ≤62 dB(A) |
| Illumination | ≥700 lux |
| Power Supply | 220 V AC, 50 Hz |
| Max. Power Consumption | 1.85 kW |
| Net Weight | 290 kg |
| Compliance | YY 0569–2005, NSF/ANSI 49–2022, EN 12469:2000, ISO 14644–1 Class 5 (ISO Class 5 Equivalent) |
Show next