- All
- Favorite
- Popular
- Most rated
| Origin | Jiangsu, China |
|---|---|
| Cabinet Type | Class II, Type B2 (Total Exhaust) |
| External Dimensions (L×W×H) | 1500 × 790 × 2050 mm |
| Internal Work Area (L×W×H) | 1300 × 600 × 620 mm |
| Filter Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity | 0.35 m/s |
| Inflow Velocity | 0.35 m/s |
| Noise Level | ≤58 dB(A) |
| Power Supply | AC 220 V, 1Φ, 50 Hz |
| Max. Rated Power | 2.1 kVA |
| Weight | 300 kg |
| Lighting | 36 W × 2 fluorescent lamps |
| UV Lamp | 20 W × 1 |
| Illuminance | ≥800 lx |
| Biological Protection Performance | ≤10 CFU/plate (impact sampler), ≤5 CFU/plate (slit sampler) |
| Product Protection | ≤5 CFU/plate |
| Cross-contamination Protection | ≤2 CFU/plate |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BHC-1300IIA/B3 |
| Instrument Class | Class II A2 Biological Safety Cabinet (30% Exhaust) |
| External Dimensions (L×W×H) | 1500 × 815 × 2270 mm |
| Internal Work Area (L×W×H) | 1300 × 600 × 640 mm |
| Filter Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity (Center) | 0.27 m/s |
| Inflow Velocity | ≥0.5 m/s |
| Noise Level | ≤58 dB(A) |
| Power Consumption | 2.1 kW |
| Weight | 340 kg |
| Lighting | 30 W × 2 Fluorescent Lamps + 30 W UV Lamp |
| Illumination | ≥650 lx |
| Airflow Configuration | Left/Right/Top Exhaust Options |
| Certified Protection Levels | Personnel Protection (≤10 CFU/plate, impact sampler), Product Protection (≤5 CFU/plate), Cross-Contamination Protection (≤2 CFU/plate) |
| Compliance | Meets ISO 14644-1 Class 5 (ISO Class 5, formerly “100”), EN 12469:2000, and GB/T 16292–16294 (Chinese Pharmacopoeia & GMP requirements) |
| Brand | HD-Lab (HDL) |
|---|---|
| Origin | Beijing, China |
| Model | BSC-1100 II A2 |
| Cabinet Class | NSF/ANSI 49–2022 & EN 12469:2000 Compliant Class II Type A2 |
| External Dimensions (L×W×H) | 1080 × 790 × 2150 mm |
| Internal Work Area (L×W×H) | 915 × 600 × 680 mm |
| ULPA Filter Efficiency | ≥99.9995% @ 0.1–0.2 µm |
| Filter Penetration Rate | ≤0.005% |
| Inflow Velocity | ≥0.5 m/s |
| Downflow Velocity | 0.25–0.5 m/s |
| Noise Level | ≤62 dB(A) |
| Illumination | ≥700 lux |
| Power Supply | 220 V AC, 50 Hz |
| Max. Power Consumption | 1.85 kW |
| Net Weight | 290 kg |
| Compliance | YY 0569–2005, NSF/ANSI 49–2022, EN 12469:2000, ISO 14644–1 Class 5 (ISO Class 5 Equivalent) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-Made) |
| Model | BHC-1300IIA2 |
| Cabinet Type | Class II, Type A2 (30% Exhaust / 70% Recirculated) |
| External Dimensions (L×W×H) | 1500 × 815 × 2270 mm |
| Internal Work Area Dimensions (L×W×H) | 1300 × 600 × 640 mm |
| Filter Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity | 0.33 m/s |
| Inflow Velocity | 0.55 m/s |
| Noise Level | ≤58 dB(A) |
| Lighting Intensity | ≥650 lux |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 2.0 kW (including dedicated GFCI outlets) |
| Net Weight | 340 kg |
| Lighting | Two 30 W fluorescent lamps + one 20 W UV lamp |
| Exhaust Options | Left, right, or top discharge |
| User Capacity | Dual-operator configuration |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Class II, Type B2 (Total Exhaust) Biosafety Cabinet |
| Model | BHC-1300IIB2 |
| External Dimensions (L×W×H) | 1525 × 830 × 2300 mm |
| Internal Work Area Dimensions (L×W×H) | 1300 × 600 × 640 mm |
| Filter Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity | 0.30 m/s |
| Inflow Velocity | 0.55 m/s |
| Noise Level | ≤58 dB(A) |
| Power Supply | AC 220 V, 1Φ, 50 Hz |
| Total Power Consumption | 2.0 kW (including auxiliary socket) |
| Weight | 340 kg |
| Lighting | 2 × 36 W fluorescent lamps |
| UV Lamp | 1 × 30 W |
| Illuminance | ≥650 lx |
| Duct Port Diameter | Ø250 mm |
| Safety Certification Compliance | EN 12469:2000, NSF/ANSI 49-2022, GB 50346-2011 |
| Brand | HDL (Harbin Donglian) |
|---|---|
| Origin | Beijing, China |
| Model | BSC-1100-L II B2 |
| Cabinet Type | Class II, Type B2 (100% Exhaust, Zero Recirculation) |
| External Dimensions (L×W×H) | 1382 × 790 × 2210 mm |
| Internal Work Area Dimensions (L×W×H) | 1220 × 600 × 680 mm |
| ULPA Filter Efficiency | ≥99.9995% for particles ≥0.1–0.2 µm |
| Filter Penetration Rate | ≤0.005% |
| Noise Level | ≤62 dB(A) |
| Inflow Velocity | >0.5 m/s |
| Downflow Velocity | 0.25–0.5 m/s |
| Vibration (RMS) | ≤3 µm |
| Illuminance | ≥700 lx |
| Power Supply | 220 V AC / 50 Hz |
| Rated Power Consumption | 1.95 kW |
| Max Power Consumption | 2.95 kW |
| Weight | 310 kg |
| Compliance | YY 0569-2005, NSF/ANSI 49-2002, EN 12469:2000 |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BSC-1300IIA2 |
| Price | USD 4,500 (FOB Jiangsu) |
| Certifications | EN 12469:2000, NSF/ANSI 49-2022 compliant |
| Airflow | Inflow velocity ≥ 0.65 m/s, Downflow velocity ≥ 0.35 m/s |
| Filtration | Dual HEPA (≥99.9995% @ 0.3 µm), Pre-filter + Exhaust HEPA + Supply HEPA |
| Noise Level | ≤58 dB(A) |
| Illumination | ≥1000 lux |
| UV Intensity | ≥80 µW/cm² |
| Work Surface Load Capacity | 25 kg |
| Electrical | 220 V ±20 V, 50 Hz, Ground Resistance ≤0.1 Ω |
| Leak Integrity | ≤10% pressure decay at 500 Pa for 30 min |
| Cleanliness Class | ISO Class 5 (100-grade) |
| Containment Performance | Personnel protection ≤10 CFU/plate (impact sampling), Product protection ≤4 CFU/plate, Cross-contamination ≤2 CFU/plate |
| Display | Full-function LCD with real-time monitoring of airflow velocities, filter differential pressure, temperature, humidity, UV status, door position, fan operation, timer, and service life tracking |
| Brand | AIRTECH (Suzhou Antai) |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Class II, Type B2 (Total Exhaust) Biosafety Cabinet |
| External Dimensions (L×W×H) | 1500 × 790 × 2050 mm |
| Internal Work Area Dimensions (L×W×H) | 1270 × 600 × 620 mm |
| HEPA Filter Efficiency | ≥99.995% @ 0.3 µm |
| ULPA Filter Efficiency | ≥99.9995% @ 0.12 µm |
| Downflow Velocity | 0.35 m/s |
| Inflow Velocity | 0.55 m/s |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 1.65 kW |
| Weight | 270 kg |
| Air Cleanliness Class | ISO 4 (equivalent to Federal Standard 209E Class 10) |
| Personnel Protection | ≤5 CFU/plate (slit sampler) |
| Product Protection | ≤2 CFU/plate |
| Cross-Contamination Protection | ≤5 CFU/plate (impact sampler), ≤5 CFU/plate (slit sampler) |
| Lighting | 24.5 W LED, ≥900 lx uniformity |
| UV Lamp | 25 W, germicidal |
| Exhaust Direction | Top-mounted ducted exhaust |
| Brand | AIRTECH (Suzhou Jintan Airtech) |
|---|---|
| Origin | Jiangsu, China |
| Model | BSC-1600IIA2 |
| Instrument Type | Class II, Type A2 Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1800 × 790 × 2050 mm |
| Internal Work Area Dimensions (L×W×H) | 1600 × 600 × 620 mm |
| Filtration Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity | 0.35 m/s |
| Inflow Velocity | 0.55 m/s |
| Noise Level | ≤62 dB(A) |
| Lighting Intensity | ≥800 lx |
| Power Consumption | 2.0 kW |
| Weight | 360 kg |
| Compliance | YY 0569–2011 (China), NSF/ANSI 49–2022 (USA) |
Show next