Empowering Scientific Discovery

Beijing Laiboruijie Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Cabinet TypeClass II, Type B2 (Total Exhaust)
External Dimensions (L×W×H)1500 × 790 × 2050 mm
Internal Work Area (L×W×H)1300 × 600 × 620 mm
Filter EfficiencyHEPA ≥99.995% @ 0.3 µm
Downflow Velocity0.35 m/s
Inflow Velocity0.35 m/s
Noise Level≤58 dB(A)
Power SupplyAC 220 V, 1Φ, 50 Hz
Max. Rated Power2.1 kVA
Weight300 kg
Lighting36 W × 2 fluorescent lamps
UV Lamp20 W × 1
Illuminance≥800 lx
Biological Protection Performance≤10 CFU/plate (impact sampler), ≤5 CFU/plate (slit sampler)
Product Protection≤5 CFU/plate
Cross-contamination Protection≤2 CFU/plate
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelBHC-1300IIA/B3
Instrument ClassClass II A2 Biological Safety Cabinet (30% Exhaust)
External Dimensions (L×W×H)1500 × 815 × 2270 mm
Internal Work Area (L×W×H)1300 × 600 × 640 mm
Filter EfficiencyHEPA ≥99.995% @ 0.3 µm
Downflow Velocity (Center)0.27 m/s
Inflow Velocity≥0.5 m/s
Noise Level≤58 dB(A)
Power Consumption2.1 kW
Weight340 kg
Lighting30 W × 2 Fluorescent Lamps + 30 W UV Lamp
Illumination≥650 lx
Airflow ConfigurationLeft/Right/Top Exhaust Options
Certified Protection LevelsPersonnel Protection (≤10 CFU/plate, impact sampler), Product Protection (≤5 CFU/plate), Cross-Contamination Protection (≤2 CFU/plate)
ComplianceMeets ISO 14644-1 Class 5 (ISO Class 5, formerly “100”), EN 12469:2000, and GB/T 16292–16294 (Chinese Pharmacopoeia & GMP requirements)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHD-Lab (HDL)
OriginBeijing, China
ModelBSC-1100 II A2
Cabinet ClassNSF/ANSI 49–2022 & EN 12469:2000 Compliant Class II Type A2
External Dimensions (L×W×H)1080 × 790 × 2150 mm
Internal Work Area (L×W×H)915 × 600 × 680 mm
ULPA Filter Efficiency≥99.9995% @ 0.1–0.2 µm
Filter Penetration Rate≤0.005%
Inflow Velocity≥0.5 m/s
Downflow Velocity0.25–0.5 m/s
Noise Level≤62 dB(A)
Illumination≥700 lux
Power Supply220 V AC, 50 Hz
Max. Power Consumption1.85 kW
Net Weight290 kg
ComplianceYY 0569–2005, NSF/ANSI 49–2022, EN 12469:2000, ISO 14644–1 Class 5 (ISO Class 5 Equivalent)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic (China-Made)
ModelBHC-1300IIA2
Cabinet TypeClass II, Type A2 (30% Exhaust / 70% Recirculated)
External Dimensions (L×W×H)1500 × 815 × 2270 mm
Internal Work Area Dimensions (L×W×H)1300 × 600 × 640 mm
Filter EfficiencyHEPA ≥99.995% @ 0.3 µm
Downflow Velocity0.33 m/s
Inflow Velocity0.55 m/s
Noise Level≤58 dB(A)
Lighting Intensity≥650 lux
Power SupplyAC 220 V, 50 Hz
Total Power Consumption2.0 kW (including dedicated GFCI outlets)
Net Weight340 kg
LightingTwo 30 W fluorescent lamps + one 20 W UV lamp
Exhaust OptionsLeft, right, or top discharge
User CapacityDual-operator configuration
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product CategoryClass II, Type B2 (Total Exhaust) Biosafety Cabinet
ModelBHC-1300IIB2
External Dimensions (L×W×H)1525 × 830 × 2300 mm
Internal Work Area Dimensions (L×W×H)1300 × 600 × 640 mm
Filter EfficiencyHEPA ≥99.995% @ 0.3 µm
Downflow Velocity0.30 m/s
Inflow Velocity0.55 m/s
Noise Level≤58 dB(A)
Power SupplyAC 220 V, 1Φ, 50 Hz
Total Power Consumption2.0 kW (including auxiliary socket)
Weight340 kg
Lighting2 × 36 W fluorescent lamps
UV Lamp1 × 30 W
Illuminance≥650 lx
Duct Port DiameterØ250 mm
Safety Certification ComplianceEN 12469:2000, NSF/ANSI 49-2022, GB 50346-2011
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHDL (Harbin Donglian)
OriginBeijing, China
ModelBSC-1100-L II B2
Cabinet TypeClass II, Type B2 (100% Exhaust, Zero Recirculation)
External Dimensions (L×W×H)1382 × 790 × 2210 mm
Internal Work Area Dimensions (L×W×H)1220 × 600 × 680 mm
ULPA Filter Efficiency≥99.9995% for particles ≥0.1–0.2 µm
Filter Penetration Rate≤0.005%
Noise Level≤62 dB(A)
Inflow Velocity>0.5 m/s
Downflow Velocity0.25–0.5 m/s
Vibration (RMS)≤3 µm
Illuminance≥700 lx
Power Supply220 V AC / 50 Hz
Rated Power Consumption1.95 kW
Max Power Consumption2.95 kW
Weight310 kg
ComplianceYY 0569-2005, NSF/ANSI 49-2002, EN 12469:2000
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelBSC-1300IIA2
PriceUSD 4,500 (FOB Jiangsu)
CertificationsEN 12469:2000, NSF/ANSI 49-2022 compliant
AirflowInflow velocity ≥ 0.65 m/s, Downflow velocity ≥ 0.35 m/s
FiltrationDual HEPA (≥99.9995% @ 0.3 µm), Pre-filter + Exhaust HEPA + Supply HEPA
Noise Level≤58 dB(A)
Illumination≥1000 lux
UV Intensity≥80 µW/cm²
Work Surface Load Capacity25 kg
Electrical220 V ±20 V, 50 Hz, Ground Resistance ≤0.1 Ω
Leak Integrity≤10% pressure decay at 500 Pa for 30 min
Cleanliness ClassISO Class 5 (100-grade)
Containment PerformancePersonnel protection ≤10 CFU/plate (impact sampling), Product protection ≤4 CFU/plate, Cross-contamination ≤2 CFU/plate
DisplayFull-function LCD with real-time monitoring of airflow velocities, filter differential pressure, temperature, humidity, UV status, door position, fan operation, timer, and service life tracking
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRTECH (Suzhou Antai)
OriginJiangsu, China
Instrument TypeClass II, Type B2 (Total Exhaust) Biosafety Cabinet
External Dimensions (L×W×H)1500 × 790 × 2050 mm
Internal Work Area Dimensions (L×W×H)1270 × 600 × 620 mm
HEPA Filter Efficiency≥99.995% @ 0.3 µm
ULPA Filter Efficiency≥99.9995% @ 0.12 µm
Downflow Velocity0.35 m/s
Inflow Velocity0.55 m/s
Noise Level≤65 dB(A)
Power SupplyAC 220 V, 1φ, 50 Hz
Rated Power1.65 kW
Weight270 kg
Air Cleanliness ClassISO 4 (equivalent to Federal Standard 209E Class 10)
Personnel Protection≤5 CFU/plate (slit sampler)
Product Protection≤2 CFU/plate
Cross-Contamination Protection≤5 CFU/plate (impact sampler), ≤5 CFU/plate (slit sampler)
Lighting24.5 W LED, ≥900 lx uniformity
UV Lamp25 W, germicidal
Exhaust DirectionTop-mounted ducted exhaust
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRTECH (Suzhou Jintan Airtech)
OriginJiangsu, China
ModelBSC-1600IIA2
Instrument TypeClass II, Type A2 Biological Safety Cabinet
External Dimensions (L×W×H)1800 × 790 × 2050 mm
Internal Work Area Dimensions (L×W×H)1600 × 600 × 620 mm
Filtration EfficiencyHEPA ≥99.995% @ 0.3 µm
Downflow Velocity0.35 m/s
Inflow Velocity0.55 m/s
Noise Level≤62 dB(A)
Lighting Intensity≥800 lx
Power Consumption2.0 kW
Weight360 kg
ComplianceYY 0569–2011 (China), NSF/ANSI 49–2022 (USA)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0