- All
- Favorite
- Popular
- Most rated
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | M80 |
| Zoom Ratio | 8:1 |
| Magnification Range | 7.5×–60× (with 1× objective and 10× eyepieces) |
| Resolution | 309 lp/mm (at 60×, 1× objective) |
| Working Distance | 83.4 mm (with Plan Apochromat 1× objective) |
| Field of View | Ø98 mm (max, dependent on optical configuration) |
| LED Illumination | 6500 K color temperature, 50,000 h lifetime, fanless thermal management |
| Optical Design | Parallel optical path (Common Main Objective, CMO), multi-coated optics, lead-free housing |
| Electrostatic Dissipation | Surface resistivity 2×10¹¹ Ω/mm², discharge time <2 s (1000 V → 100 V) |
| Modular Interface | 8-position zoom detent slots for repeatable magnification settings |
| Objective Options | Achromatic (0.32×–2.0×), Plan Apochromat (0.8×–1.6×) |
| Eyepiece Options | Widefield 10×, 16×, 25×, 40× with adjustable eye cups and interpupillary distance |
| Ergonomic Modules | ErgoTube® and ErgoModules® with tilt angle 10°–50° |
| Software Compatibility | Leica Application Suite (LAS) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | M50 |
| Zoom Ratio | 5:1 |
| Magnification Range (with standard optics) | 6.3×–40× |
| Max. Total Magnification | 320× |
| Objective Types | Achromatic (0.32×–2.0×), Plan Achromatic (0.8×–1.6×) |
| Working Distance Range | 27.4 mm – 303 mm |
| Field of View Diameter | 5.75 mm – 116.8 mm |
| Resolution (at 40×) | 225 lp/mm |
| Numerical Aperture (1× objective) | 0.15 |
| Ergonomic Viewing Angle | 10°–50° |
| ESD Compliance | Surface Resistivity 2×10¹¹ Ω/mm², Discharge Time <2 s (1000 V → 100 V) |
| Optical Design | Common Main Objective (CMO), Parallel Light Path |
| Coating | Multi-layer anti-reflective coatings |
| Eyepieces | Wide-field 10×, 16×, 25×, 40× with adjustable eyecups and click-stop positioning |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | EZ4HD |
| Zoom Ratio | 4.4:1 |
| Magnification Range | 8×–35× |
| Objective Zoom Range | 0.8×–3.5× |
| Eyepieces | 10×/20 mm field of view |
| Working Distance | 100 mm |
| Illumination | 7-LED modular system (incident, transmitted, oblique) |
| Camera | Integrated 3 MP CMOS sensor (2048 × 1536 resolution) |
| Software | Leica LAS EZ (with measurement, annotation, focus stacking modules) |
| Compliance | CE, RoHS, ISO 9001 manufacturing environment |
| Lifetime LED Source | >20,000 hours |
| Origin | Chongqing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SMZ-T4 |
| Price | USD 495 (FOB Chongqing) |
| Zoom Ratio | 1:6.5 |
| Magnification Range | 7×–45× |
| Objective Zoom Range | 0.7×–4.5× |
| Eyepieces | Widefield WF10×/22 mm (High-Eyepoint) |
| Working Distance | 110 mm |
| Interpupillary Adjustment | 54–76 mm |
| Diopter Adjustment | ±5 D |
| Observation Head | 45° Inclined, 360° Rotatable |
| Illumination | Dual LED — Adjustable Brightness Reflected & Transmitted |
| Input Voltage | 220 V AC, 50 Hz |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | S8 APO |
| Zoom Ratio | 8:1 |
| Magnification Range | 10×–80× |
| Viewing Angle | 38° |
| Eyepiece | 10× widefield |
| Objective | 1× apochromatic (APO) |
| Resolution (max) | 300 lp/mm at 80× |
| Resolution (2× objective option) | up to 600 lp/mm |
| Working Distance | 75 mm |
| Imaging Interface | C-mount |
| Optical Design | Greenough stereoscopic principle |
| Color Correction | Apochromatic (APO) light path |
| Photo/Video Path | 100% light split for simultaneous imaging and observation |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | SZ51 |
| Total Magnification | 40× |
| Zoom Ratio | 5:1 |
| Working Distance | 110 mm |
| Objective Type | 1× |
| Illumination | LED |
| Depth of Field | Compatible with C-mount camera systems |
| Eyepiece Angle | 45° |
| Interpupillary Adjustment Range | 52–76 mm (with WHSZ10× eyepieces) |
| LED Lifespan | 6,000 hours |
| Power Input | 100–120 V / 200–240 V AC, 50/60 Hz |
| Weight (Zoom Body) | 1.3 kg |
| Optical System | Greenough design |
| Environmental Compliance | Lead-free optical components |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | M205 |
| Total Magnification | 1280× |
| Zoom Ratio | 7.8×–160× |
| Working Distance | 61.5 mm (with 1× Plan Apochromat objective) |
| Objective Type | Plan Apochromat |
| Illumination | LED5000RL Ring Light |
| Field of View | Ø59 mm (max), 1.44 mm (min) |
| Numerical Aperture | 0.35 |
| Resolution | 1050 lp/mm (max, with optimized optical configuration) |
| Viewing Angle | 30° trinocular tube |
| FusionOptics™ Technology | Standard (M205C/M205A) |
| Depth of Field Optimization | Dual-channel independent depth/resolution balancing |
| Encoding | Motorized or manual magnification encoding (model-dependent) |
| Optical Architecture | Common Main Objective (CMO), parallel beam path, lead-free housing (<2 s discharge time, surface resistivity 2×10¹¹ Ω/mm²) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | SMZ-B2 |
| Price | USD 395 (FOB) |
| Magnification Range | 2.1×–225× (with auxiliary lenses & eyepieces) |
| Zoom Ratio | 1:6.5 (0.7×–4.5× objective zoom) |
| Working Distance | 36 mm – 316 mm |
| Eyepieces | WF10×/20 mm, WF10×/22 mm, WF15×, WF20×, WF25×, 10× reticle |
| Auxiliary Objectives | 0.3×, 0.5×, 0.75×, 1.5×, 2× |
| C-Mount Adapters | 0.35×, 0.5×, 1× |
| Camera Interfaces | Nikon F-mount, Olympus OM-mount, Pentax PK, Minolta MD, Canon FD (via adapter) |
| Digital Imaging Options | DV130 (1.3 MP), DV200 (2.0 MP) USB cameras |
| Illumination | 12 V / 15 W adjustable halogen epi-illuminator with reflector bowl |
| Trinocular Port | 20% / 80% beam splitter, simultaneous visual and imaging output |
| Interpupillary Adjustment | 54–76 mm |
| Diopter Compensation | ±5 D |
| Head Inclination | 45°, rotatable 360° |
| Power Supply | 220 V AC, 50 Hz |
| Brand | Leica |
|---|---|
| Model | S4E |
| Optical System | Greenough |
| Zoom Ratio | 4.8:1 |
| Magnification (Standard) | 6.3×–30× |
| Field of View Diameter | 36.5 mm |
| Working Distance (Standard) | 110 mm |
| Eyepiece Angle | 38° |
| Numerical Aperture (Max) | 0.124 |
| Resolution (Max) | 372 lp/mm |
| ESD Protection | Surface Resistivity 2×10¹¹ Ω/sq, Discharge Time <2 s (1000 V → 100 V) |
| Interpupillary Distance | 55–75 mm |
| Eyepieces | 10×/23, 16×/16, 20×/12, 25×/9.5, 40×/6 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SMP-POL |
| Price | USD 3,050 (FOB Beijing) |
| Optical System | Parallel-Beam Zoom Architecture |
| Zoom Ratio | 1:6.6 (0.68× – 4.5× objective magnification) |
| Eyepieces | Widefield High-Eye-Point WFH10×/22 mm |
| Working Distance | 92 mm (max. 333 mm) |
| Field of View | 4.8 mm – 33 mm (max. 118 mm diameter) |
| Focus Travel | 45 mm |
| Interpupillary Adjustment | 52–80 mm |
| Diopter Compensation | ±6 D |
| Viewing Angle Adjustment | 0°–30° continuous tilt |
| Total Magnification Range | 2.1× – 281× (with optional auxiliary lenses and eyepiece combinations) |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | SZ61 |
| Total Magnification Range | 0.67×–4.5× (with 10× eyepieces: 6.7×–45×) |
| Zoom Ratio | 6.7:1 |
| Working Distance | 110 mm |
| Objective Type | 1× |
| Illumination | Integrated LED (reflected & transmitted, optional) |
| Depth of Field | Compatible with C-mount digital imaging systems (0.5× built-in adapter) |
| Eyepiece Angle | 45° inclined binocular tube |
| Interpupillary Adjustment | 52–76 mm (with WHSZ series eyepieces) |
| Optical System | Greenough stereoscopic design |
| Compliance | RoHS-compliant, lead-free optical components |
| LED Lifetime | ≥6,000 hours |
| Power Input | 100–120 V / 200–240 V AC, 50/60 Hz |
| Weight | 1.3 kg (zoom body only) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | M60 |
| Zoom Ratio | 6.3:1 |
| Working Distance | 27.4 mm (at 2.0×) to 303 mm (at 0.32×) |
| Field of View | Ø5.75 mm – Ø116.8 mm |
| Max Magnification | 320× (with 2.0× objective + 40× eyepieces) |
| Resolution | 225–450 lp/mm (dependent on objective and eyepiece combination) |
| Numerical Aperture | 0.15 (at 1×) |
| Fixed Zoom Stops | 7 positions |
| Ergonomic Viewing Angle | 10°–50° |
| Tube Type | CMO (Common Main Objective) optical design |
| Surface Resistivity | 2×10¹¹ Ω/mm² |
| Discharge Time | <2 s (1000 V → 100 V) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | S6E |
| Zoom Ratio | 6.3:1 |
| Magnification Range | 6.3×–40× |
| Field of View Diameter | 36.5 mm |
| Working Distance (standard) | 110 mm |
| Viewing Angle | 38° |
| Eyepiece Options | 10×/23, 16×/16, 20×/12, 25×/9.5, 40×/6 |
| Interpupillary Distance Adjustment | 55–75 mm |
| Objective Types | Achromatic (0.32×, 0.5×, 0.63×, 0.75×, 1.6×, 2.0×) |
| Numerical Aperture (max) | 0.144 |
| Resolution (max) | 432 lp/mm |
| ESD Protection | Surface resistivity 2×10¹¹ Ω/sq, discharge time <2 s (1000 V → 100 V) |
| Optical Design | Greenough-type, lead-free optics |
| Video/Photo Port | Coaxial output, switchable |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | M125 |
| Total Magnification Range | 8×–100× |
| Zoom Ratio | 12.5 : 1 |
| Field Diameter | 28.8 mm (at 8×) to 2.3 mm (at 100×) |
| Working Distance | 61.5 mm (with 1× Plan Apo Chromat objective) |
| Objective Type | 1× Plan Apo Chromat (standard) |
| Numerical Aperture | 0.288 |
| Depth of Field Control | Dual adjustable aperture |
| Viewing Angle | 30° trinocular tube |
| Resolution | Up to 864 lp/mm (with optimal optical configuration) |
| Eyepiece Options | 10×/23 mm, 16×/15 mm, 25×/9.5 mm, 40×/6 mm wide-field eyepieces |
| Diopter Adjustment | ±5° per eyepiece |
| Compatible Objectives | 0.5×, 0.63×, 0.8×, 1×, 1.6×, 2× Plan Apo Chromat and Plan Achromat objectives |
| Illumination | LED or cold-light sources (optional) |
| Imaging Interface | C-mount compatible for CCD/camera systems |
| Software Compatibility | Supports Leica Application Suite (LAS), LAS X, and third-party image analysis platforms compliant with TWAIN/DirectShow |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | SZ700TR |
| Price | USD 2,200 (FOB Beijing) |
| Zoom Ratio | 8.8:1 (0.8×–7.0× Objective Zoom) |
| Standard Total Magnification Range | 8×–70× (with 10× Eyepieces) |
| Working Distance | 108 mm (standard), down to 35 mm with 2.0× Auxiliary Objective |
| Eyepiece | SWH10× (23 mm Field Number, High-Eye-Point, Widefield) |
| Interpupillary Adjustment | 52–76 mm (linked) |
| Diopter Compensation | ±6 D per eyepiece |
| Inclination | 35° Tilting Binocular/Triocular Tube |
| Rotation | 360° Swivel Head |
| Focusing Travel | 100 mm (vertical column) |
| Stage Diameter | Ø95 mm |
| Pillar Diameter | Ø25 mm |
| Center-to-Center Distance (Pillar to Bracket) | 140 mm |
| Bracket Mounting Diameter | Ø76 mm |
| Illumination Options | Adjustable 6 V / 10 W Halogen Reflector Lamp |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | M165C |
| Total Zoom Ratio | 16.5:1 |
| Magnification Range | 7.3×–120× (with 10× eyepieces and 1× objective) |
| Field Diameter | 61.5 mm |
| Working Distance | 61.5 mm (with 1× Plan Apochromat objective) |
| Objective Type | Plan Apochromat |
| Illumination | Halogen |
| Viewing Angle | 30° trinocular tube |
| Numerical Aperture | 0.302 |
| Depth of Field Control | Encoded dual variable aperture |
| ESD-Safe Housing | Surface resistivity <2×10¹¹ Ω/mm², discharge time <2 s (1000 V → 100 V) |
| Compatibility | Digital cameras, C-mount adapters, fluorescence filter cubes with encoded position feedback |
| Software Integration | Leica Application Suite (LAS X), supports FDA 21 CFR Part 11 compliant audit trails and GLP/GMP metadata tagging |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | S6 |
| Zoom Ratio | 6.3:1 |
| Magnification Range | 6.3× to 40× |
| Viewing Angle | 60° (S6 standard), 38° (S6 E variant) |
| Working Distance | 110 mm |
| Eyepiece Field of View | 23 mm (with 10× eyepieces), up to 36.5 mm maximum |
| Electrostatic Dissipation | 10⁶ Ω/square (S6 T variant) |
| Imaging Interface | 100% photo/video port with 100% light path toggle (S6 D variant) |
Show next