BrandTecan
OriginSwitzerland
ModelF50
Function TypeMultimode
Automation LevelSemi-Automated
Detection MethodAbsorbance (Photometric)
Wavelength Range400–750 nm
Absorbance Range0–4.00 OD
Linearity Range0.000–2.000 Abs
Optical Channels8-Channel Simultaneous Detection
Wavelength Accuracy±2 nm
Absorbance Resolution0.0001 OD
Read Speed<10 sec per 96-well plate (single wavelength)
Light SourceHigh-Stability LED Array
Plate Formats6–384-well microplates, cuvettes (optional)
ComplianceISO 13485:2016, FDA 21 CFR Part 11 (with Magellan Tracker), EU IVD Directive 98/79/EC, RoHS & WEEE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBerthold
OriginGermany
ModelTristar² S LB 942
Detection ModesAbsorbance, Luminescence, Fluorescence (top/bottom read), Time-Resolved Fluorescence (TRF), Homogeneous Time-Resolved Fluorescence (HTRF®), Fluorescence Polarization (FP), Bioluminescence Resonance Energy Transfer (BRET/BRET²/NanoBRET), Fluorescence Resonance Energy Transfer (FRET)
DetectorLow-noise, high-speed single-photon counting PMT and photodiode
Absorbance Range0–4 OD
Absorbance Linearity<0.1%
Wavelength Accuracy±1 nm
Wavelength Scanning Speed0.1 s per data point
Absorbance Precision<0.3%
Luminescence Sensitivity<6 amol ATP/well (96-well, glow assay)
Fluorescence Sensitivity<0.2 fmol fluorescein/well (96-well)
TRF Sensitivity<5 amol europium/well
Dynamic Range>6 decades
Well-to-Well Crosstalk<5×10⁻⁶
Injector OptionsUp to 3 programmable injectors (10–100 µL, 1 µL increment)
Temperature ControlAmbient +5 °C to 45 °C (optional) with cooled PMT
Compatible Plate Formats6–384-well microplates, Eppendorf µPlate GO.5, Terasaki plates, Petri dishes
Excitation SourceXenon flash lamp
MonochromatorDual grating (4–22 nm bandwidth, 1 nm increment) for absorbance/fluorescence excitation
Filter CapacityUp to 30 high-transmission (>80%) interference filters (excitation & emission)
SoftwareICE™ (Instrument Control & Evaluation), compliant with 21 CFR Part 11 audit trail and electronic signature requirements
CertificationsCE, RoHS, ISO 13485–aligned design
Operating Environment15–35 °C, 10–85% RH (non-condensing)
Storage0–40 °C
Power Supply110–240 V AC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTecan
OriginSwitzerland
ModelSunrise
TypeAbsorbance Microplate Reader
Automation LevelFully Automated
Measurement MethodsSingle-/Multi-wavelength, Kinetic Assays
Wavelength Range340–750 nm
Absorbance Range0–3.0 OD (340–399 nm), 0–4.0 OD (400–750 nm)
Linearity0.000–2.0 OD
Detection SpeedFull-plate scan in 5 seconds (12-channel parallel detection)
Optical Resolution0.001 OD
Filter Options4-position, 6-position, or continuous monochromator (400–700 nm)
ComplianceFDA 21 CFR Part 11 (Magellan Tracker), EU IVD Directive 98/79/EC (Magellan Clinical)
Software PlatformMagellan™ (PC & embedded Windows CE versions)
Integration CapabilityCompatible with Freedom EVO® and Freedom EVOlyzer® automated platforms
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ModelFC
Detection MethodAbsorbance (Photometric)
FunctionalitySingle-mode
Automation LevelSemi-automated
Measurement ModeEndpoint Scanning
Curve FittingPolynomial, Linear, Log-Log, 4-Parameter Logistic (4PL), and Other Standard Functions
Detector TypeUV-Visible Photodiode Array
Wavelength Range340–850 nm
Absorbance Range0–6 ABS
Linear Range0–3 ABS (at 405 nm, 96-well, standard mode)
Wavelength Selection Speed6 s per wavelength (96-well plate, fast mode)
Accuracy±1% (0–3 ABS), ±2% (3–4 ABS) at 405 nm
Precision (CV)≤0.2% (0–3 ABS), ≤1.0% (3–4 ABS), standard mode
Optical Resolution0.001 ABS
Filter Wheel8-position, standard filters: 405 nm, 450 nm, 620 nm
optional filters available (FWHM3–9 nm)
Plate Formats96-well and 384-well microplates
Incubation (optional)RT +4°C to 50°C
ShakingLinear shaking with three speed settings
Display480 × 272 pixel color LCD touchscreen
Onboard Memory100 protocols + 100 result sets (96-well)
Interfaces3× USB (PC, printer, USB storage)
ComplianceRoHS, CE (2002/96/EC), FCC Part 15 Subpart B Class B, IEC 61010-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBerthold
OriginGermany
ModelMithras² LB 943
Function TypeMultimode
Automation LevelSemi-Automatic
Assay MethodsEndpoint, Kinetic, Long-Term Kinetic, Well-Scanning
Curve FittingLinear, Non-Linear, Logarithmic
Detector TypesPMT (3), Photodiode (1)
Wavelength Range200–850 nm (standard), up to 1000 nm (optional)
Absorbance Range0–4 OD
Absorbance Linearity<0.1%
Wavelength Accuracy±1 nm
Precision (CV)<0.3%
Luminescence Sensitivity<2 amol ATP/well (96-well, Glow)
Fluorescence Sensitivity<0.1 fmol Fluorescein/well (96-well)
TRF Sensitivity<2 amol Europium/well (96-well)
HTRF® Dynamic Range>600% ΔF
FP Sensitivity<4 mP
AlphaScreen® Detection Limit<12 ng
Crosstalk<5×10⁻⁶
Excitation SourcesHalogen lamp, Xenon flash lamp, Laser (optional)
MonochromatorDual grating (excitation & emission), bandwidth 4–22 nm adjustable in 1 nm steps, optical density >10⁶
Reading ModesTop & Bottom Read (all modalities)
Plate Formats6–1536-well microplates, Petri dishes, Terasaki plates
Temperature ControlAmbient +5 °C to 45 °C (optional)
CertificationsCE, UL, CSA
Power Supply110–240 V AC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA (assembled in Shanghai)
ModelMK3
Function TypeMultifunctional
Automation LevelSemi-Automatic
Measurement MethodScanning
Curve FittingMathematical Functions
Detector TypeUV-Vis Photomultiplier Tube (PMT)
Wavelength Range340–850 nm
Absorbance Range0–4.0 ABS
Linearity Range0–2.0 ABS
Wavelength Switching Time6 s
Photometric Accuracy±1% (0–2.0 ABS)
Precision (CV)<0.5% (0–1.5 ABS)
Resolution0.001 ABS
Plate Read Time≤5 s per 96-well plate
Optical SystemMulti-channel fiber-optic detection
Filter CapacityUp to 8 positions, motorized filter wheel
Built-in ShakerLinear, 3 adjustable speeds
Dimensions140 × 420 × 320 mm
Weight11 kg
Power Supply220–240 V, 50/60 Hz
Light SourceTungsten-halogen lamp with spare bulb included
InterfaceRS-232 serial port, parallel printer port
Onboard Display2 × 20 character LCD
Keyboard30-key tactile membrane keypad
Data Storage64 programmable protocols and calibration curves
SoftwareWindows-based MK3 Control & Analysis Suite (included)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelAMR-100
Function TypeMultimode
Automation LevelFully Automated
Measurement PrincipleFilter-Based Absorbance Detection
Wavelength Range400–750 nm
Absorbance Range0.000–4.000 Abs
Linearity±1% (0–2.000 Abs), ±2% (2.000–4.000 Abs)
Accuracy (405 nm)±1% (0–3 Abs), ±2% (3–4 Abs)
Precision (CV, 405 nm)≤0.2% (0–3 Abs), ≤1.0% (3–4 Abs)
Detection Speed<6 s/96-well (single wavelength), <9 s/96-well (dual wavelength)
Optical System8-channel high-precision fiber-optic path with automatic well-centering
Filter Capacity8-position filter wheel (standard filters: 405, 450, 490/492, 630 nm)
Display7-inch color TFT touchscreen (800 × 480 px)
Plate CompatibilityStandard 96-well microplates and strip formats
Onboard Storage200 protocols + 100,000 assay results (96-well format)
Interfaces3 × USB (PC, printer, USB drive), Wi-Fi
Power SupplyAC 100–240 V, 50–60 Hz
Lamp TypeLong-life halogen lamp (≥4000 h)
Built-in DiagnosticsReal-time self-check of optical path, mechanical positioning, plate loading, and filter alignment
Shaking FunctionAdjustable speed and duration
Safety MechanismMotorized door with obstacle-detection reversal