| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | F50 |
| Function Type | Multimode |
| Automation Level | Semi-Automated |
| Detection Method | Absorbance (Photometric) |
| Wavelength Range | 400–750 nm |
| Absorbance Range | 0–4.00 OD |
| Linearity Range | 0.000–2.000 Abs |
| Optical Channels | 8-Channel Simultaneous Detection |
| Wavelength Accuracy | ±2 nm |
| Absorbance Resolution | 0.0001 OD |
| Read Speed | <10 sec per 96-well plate (single wavelength) |
| Light Source | High-Stability LED Array |
| Plate Formats | 6–384-well microplates, cuvettes (optional) |
| Compliance | ISO 13485:2016, FDA 21 CFR Part 11 (with Magellan Tracker), EU IVD Directive 98/79/EC, RoHS & WEEE |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | Tristar² S LB 942 |
| Detection Modes | Absorbance, Luminescence, Fluorescence (top/bottom read), Time-Resolved Fluorescence (TRF), Homogeneous Time-Resolved Fluorescence (HTRF®), Fluorescence Polarization (FP), Bioluminescence Resonance Energy Transfer (BRET/BRET²/NanoBRET), Fluorescence Resonance Energy Transfer (FRET) |
| Detector | Low-noise, high-speed single-photon counting PMT and photodiode |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | <0.1% |
| Wavelength Accuracy | ±1 nm |
| Wavelength Scanning Speed | 0.1 s per data point |
| Absorbance Precision | <0.3% |
| Luminescence Sensitivity | <6 amol ATP/well (96-well, glow assay) |
| Fluorescence Sensitivity | <0.2 fmol fluorescein/well (96-well) |
| TRF Sensitivity | <5 amol europium/well |
| Dynamic Range | >6 decades |
| Well-to-Well Crosstalk | <5×10⁻⁶ |
| Injector Options | Up to 3 programmable injectors (10–100 µL, 1 µL increment) |
| Temperature Control | Ambient +5 °C to 45 °C (optional) with cooled PMT |
| Compatible Plate Formats | 6–384-well microplates, Eppendorf µPlate GO.5, Terasaki plates, Petri dishes |
| Excitation Source | Xenon flash lamp |
| Monochromator | Dual grating (4–22 nm bandwidth, 1 nm increment) for absorbance/fluorescence excitation |
| Filter Capacity | Up to 30 high-transmission (>80%) interference filters (excitation & emission) |
| Software | ICE™ (Instrument Control & Evaluation), compliant with 21 CFR Part 11 audit trail and electronic signature requirements |
| Certifications | CE, RoHS, ISO 13485–aligned design |
| Operating Environment | 15–35 °C, 10–85% RH (non-condensing) |
| Storage | 0–40 °C |
| Power Supply | 110–240 V AC, 50/60 Hz |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | Sunrise |
| Type | Absorbance Microplate Reader |
| Automation Level | Fully Automated |
| Measurement Methods | Single-/Multi-wavelength, Kinetic Assays |
| Wavelength Range | 340–750 nm |
| Absorbance Range | 0–3.0 OD (340–399 nm), 0–4.0 OD (400–750 nm) |
| Linearity | 0.000–2.0 OD |
| Detection Speed | Full-plate scan in 5 seconds (12-channel parallel detection) |
| Optical Resolution | 0.001 OD |
| Filter Options | 4-position, 6-position, or continuous monochromator (400–700 nm) |
| Compliance | FDA 21 CFR Part 11 (Magellan Tracker), EU IVD Directive 98/79/EC (Magellan Clinical) |
| Software Platform | Magellan™ (PC & embedded Windows CE versions) |
| Integration Capability | Compatible with Freedom EVO® and Freedom EVOlyzer® automated platforms |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | FC |
| Detection Method | Absorbance (Photometric) |
| Functionality | Single-mode |
| Automation Level | Semi-automated |
| Measurement Mode | Endpoint Scanning |
| Curve Fitting | Polynomial, Linear, Log-Log, 4-Parameter Logistic (4PL), and Other Standard Functions |
| Detector Type | UV-Visible Photodiode Array |
| Wavelength Range | 340–850 nm |
| Absorbance Range | 0–6 ABS |
| Linear Range | 0–3 ABS (at 405 nm, 96-well, standard mode) |
| Wavelength Selection Speed | 6 s per wavelength (96-well plate, fast mode) |
| Accuracy | ±1% (0–3 ABS), ±2% (3–4 ABS) at 405 nm |
| Precision (CV) | ≤0.2% (0–3 ABS), ≤1.0% (3–4 ABS), standard mode |
| Optical Resolution | 0.001 ABS |
| Filter Wheel | 8-position, standard filters: 405 nm, 450 nm, 620 nm |
| optional filters available (FWHM | 3–9 nm) |
| Plate Formats | 96-well and 384-well microplates |
| Incubation (optional) | RT +4°C to 50°C |
| Shaking | Linear shaking with three speed settings |
| Display | 480 × 272 pixel color LCD touchscreen |
| Onboard Memory | 100 protocols + 100 result sets (96-well) |
| Interfaces | 3× USB (PC, printer, USB storage) |
| Compliance | RoHS, CE (2002/96/EC), FCC Part 15 Subpart B Class B, IEC 61010-1 |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | Mithras² LB 943 |
| Function Type | Multimode |
| Automation Level | Semi-Automatic |
| Assay Methods | Endpoint, Kinetic, Long-Term Kinetic, Well-Scanning |
| Curve Fitting | Linear, Non-Linear, Logarithmic |
| Detector Types | PMT (3), Photodiode (1) |
| Wavelength Range | 200–850 nm (standard), up to 1000 nm (optional) |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | <0.1% |
| Wavelength Accuracy | ±1 nm |
| Precision (CV) | <0.3% |
| Luminescence Sensitivity | <2 amol ATP/well (96-well, Glow) |
| Fluorescence Sensitivity | <0.1 fmol Fluorescein/well (96-well) |
| TRF Sensitivity | <2 amol Europium/well (96-well) |
| HTRF® Dynamic Range | >600% ΔF |
| FP Sensitivity | <4 mP |
| AlphaScreen® Detection Limit | <12 ng |
| Crosstalk | <5×10⁻⁶ |
| Excitation Sources | Halogen lamp, Xenon flash lamp, Laser (optional) |
| Monochromator | Dual grating (excitation & emission), bandwidth 4–22 nm adjustable in 1 nm steps, optical density >10⁶ |
| Reading Modes | Top & Bottom Read (all modalities) |
| Plate Formats | 6–1536-well microplates, Petri dishes, Terasaki plates |
| Temperature Control | Ambient +5 °C to 45 °C (optional) |
| Certifications | CE, UL, CSA |
| Power Supply | 110–240 V AC, 50/60 Hz |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA (assembled in Shanghai) |
| Model | MK3 |
| Function Type | Multifunctional |
| Automation Level | Semi-Automatic |
| Measurement Method | Scanning |
| Curve Fitting | Mathematical Functions |
| Detector Type | UV-Vis Photomultiplier Tube (PMT) |
| Wavelength Range | 340–850 nm |
| Absorbance Range | 0–4.0 ABS |
| Linearity Range | 0–2.0 ABS |
| Wavelength Switching Time | 6 s |
| Photometric Accuracy | ±1% (0–2.0 ABS) |
| Precision (CV) | <0.5% (0–1.5 ABS) |
| Resolution | 0.001 ABS |
| Plate Read Time | ≤5 s per 96-well plate |
| Optical System | Multi-channel fiber-optic detection |
| Filter Capacity | Up to 8 positions, motorized filter wheel |
| Built-in Shaker | Linear, 3 adjustable speeds |
| Dimensions | 140 × 420 × 320 mm |
| Weight | 11 kg |
| Power Supply | 220–240 V, 50/60 Hz |
| Light Source | Tungsten-halogen lamp with spare bulb included |
| Interface | RS-232 serial port, parallel printer port |
| Onboard Display | 2 × 20 character LCD |
| Keyboard | 30-key tactile membrane keypad |
| Data Storage | 64 programmable protocols and calibration curves |
| Software | Windows-based MK3 Control & Analysis Suite (included) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-100 |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Measurement Principle | Filter-Based Absorbance Detection |
| Wavelength Range | 400–750 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Linearity | ±1% (0–2.000 Abs), ±2% (2.000–4.000 Abs) |
| Accuracy (405 nm) | ±1% (0–3 Abs), ±2% (3–4 Abs) |
| Precision (CV, 405 nm) | ≤0.2% (0–3 Abs), ≤1.0% (3–4 Abs) |
| Detection Speed | <6 s/96-well (single wavelength), <9 s/96-well (dual wavelength) |
| Optical System | 8-channel high-precision fiber-optic path with automatic well-centering |
| Filter Capacity | 8-position filter wheel (standard filters: 405, 450, 490/492, 630 nm) |
| Display | 7-inch color TFT touchscreen (800 × 480 px) |
| Plate Compatibility | Standard 96-well microplates and strip formats |
| Onboard Storage | 200 protocols + 100,000 assay results (96-well format) |
| Interfaces | 3 × USB (PC, printer, USB drive), Wi-Fi |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Lamp Type | Long-life halogen lamp (≥4000 h) |
| Built-in Diagnostics | Real-time self-check of optical path, mechanical positioning, plate loading, and filter alignment |
| Shaking Function | Adjustable speed and duration |
| Safety Mechanism | Motorized door with obstacle-detection reversal |