| Brand | PerkinElmer (licensed from PerfectLight) |
|---|---|
| Model | PLS-MRRS |
| Temperature Range | Up to 800 °C |
| Pressure Range | Up to 3.0 MPa |
| Reactor Stages | Up to 4 cascaded units |
| Gas Inlets | 4 independent channels |
| Liquid Inlet | 1 precision syringe pump path |
| Preheating Temp | Up to 600 °C |
| Tubing Trace Heating | Up to 250 °C |
| Control Interface | 10.2″ touchscreen with embedded SCADA software |
| Safety Compliance | Dual hardware/software interlock, flame arrestors, leak detection, over-temp/over-pressure shutdown |
| Brand | PerfecLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR-SMCR1000 |
| Pressure Rating | ≥0.6 MPa |
| Optical Path Depth | 0.1–10 mm |
| Liquid Flow Range | 0.5–8.0 mL/min |
| Gas Flow Range | 0–20 mL/min |
| Residence Time | 0.625–20 min |
| LED Wavelength Range | 255–760 nm |
| LED Power | 10–120 W |
| Overall Heat Transfer Coefficient | ≥250 kW/(m³·K) |
| Temperature Control Range | −10°C to +80°C |
| Brand | PerfectLight |
|---|---|
| Model | PL-SPV/IPCE1000 |
| Measurement Principle | Steady-state surface photovoltage (SPV) and incident photon-to-current efficiency (IPCE) spectroscopy |
| Wavelength Range | 300–1000 nm |
| Spectral Resolution | 2 nm |
| Minimum Detectable Photovoltage | >100 nV |
| Minimum Detectable Photocurrent | >100 pA |
| Phase Detection Range | ±180° |
| Optical Configuration | Monochromator-coupled lock-in detection with reference photodiode calibration |
| Brand | Perfetlight |
|---|---|
| Model | Labsolar-IIIAG |
| Origin | Beijing, China |
| Construction | All-glass vacuum-sealed reactor system |
| Gas Circulation | Passive magnetic-drive high-speed loop (≥4000 rpm) |
| Sampling | Manual online sampling with 1.5 mL borosilicate glass quantitative loop |
| Vacuum Performance | ≤0.1 MPa absolute pressure, leak rate ≤1 kPa/24 h |
| Compliance | Designed for ISO/IEC 17025-aligned photocatalytic testing environments |
| Software Interface | Standalone hardware control (no embedded software) |
| Regulatory Context | Supports GLP-compliant experimental documentation when integrated with audit-trail-enabled chromatography data systems (e.g., Chromeleon, OpenLab CDS) |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IPCE 1000 |
| Pricing | Upon Request |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLC-GDHC I |
| Flow Control Range | 3–100 mL/min (1 gas inlet standard) |
| Temperature Range | 5–80 °C (thermostatic bath controlled) |
| Pressure Rating | 0.2 MPa (gauge) |
| Pressure Measurement Range | −1 to 1 MPa (gauge), ±0.25% F.S. |
| Pressure Control Range | −0.08 to 0.3 MPa |
| Pressure Stability | ±0.01 MPa |
| Light Source | Integrated white LED (400–800 nm), motorized vertical adjustment |
| Optical Window Transmission | 0.19–5 μm, Ø35 mm |
| Reactor Gas Volume | 120 mL |
| Max Liquid Fill Volume | 10 mL |
| Catalyst Loading | Powder catalysts evenly spread on hydrophobic porous gas diffusion layer (GDL), GDL diameter: Φ35 mm (effective), Φ37–Φ40 mm (overall) |
| Main Body Material | High-temp powder-coated metal chassis |
| Gas Diffusion Chamber | Anodized aluminum |
| Inlet Chamber | Borosilicate glass |
| [Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR-RP Series |
| Configuration Options | Vertical/Horizonal Furnace |
| Max. Temp. | 650–1050 °C (configurable) |
| Max. Pressure | 3–10 MPa (gauge, configurable) |
| Light Delivery | Quartz Column–Based Axial Illumination & Annular Illumination Reactors |
| Catalyst Loading Capacity | Up to 9 mL (annular mode) |
| Temperature Control | 16-Stage Programmable Ramp/Soak |
| Compliance | Designed for ASTM E2934, ISO 18750, and GLP-aligned experimental traceability] |