| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | 6A |
| Valve Material | High-Borosilicate Glass |
| Actuation | Pneumatic/Electric Auto-Actuators |
| Gas Mixing Time | <10 min (H₂, O₂, CH₄, CO) |
| Calibration Linearity | R² > 0.9995 (H₂: 100 μL–10 mL) |
| Repeatability | RSD < 3% (n = 4) |
| Sampling Volume | 0.6 mL or 2.0 mL (selectable) |
| System Dead Volume | 65 mL |
| Vacuum Tightness | ≤1 μmol O₂/24 h |
| Absolute Vacuum Limit | ≤1.5 kPa |
| Operating Pressure Range | 0 kPa (vacuum) to ambient pressure |
| Pump Type | Oil-Free Magnetic-Drive Piston Pump (no electrical wiring in gas path) |
| Flow Direction Control | Integrated Unidirectional Valve Architecture |
| Temperature Control | 10-Stage Programmable, ±0.1 °C accuracy, up to 200 °C (loop & injection lines) |
| Condenser | Spherical or Coiled Glass Cold Trap (standard), Optional Cryogenic Cold Trap |
| Detection Limits (� | mol): H₂: 0.05 |
| O₂ | 0.1 |
| CH₄/CO | 0.0005 |
| Software | 32-bit Embedded Control Suite + 4.5″ TFT Touchscreen |
| Compliance | ASTM E2500, ISO/IEC 17025-aligned architecture, GLP-ready audit trail logging |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR RVTF-POX |
| Reaction Pressure Range | 0.2 (gauge) – 6 MPa |
| Reaction Temperature Range | 80 – 600 °C |
| Catalyst Bed Volume | 0.2 – 0.8 mL |
| Reactor Type | Quartz fixed-bed with metallic outer jacket and integrated light-conducting optics |
| Heating Configuration | Dual-channel, three-zone furnace with 16-segment programmable ramp/soak profiles |
| Gas Flow Control | Three independent mass flow controllers (500/200/200 mL/min, 4–100% FS, ±1% FS accuracy) |
| Liquid Flow Rate | 0.001–4.999 mL/min (water-compatible) |
| Preheating Temp Range | 50–400 °C (16-segment program) |
| Trace Heating | 150–240 °C |
| Total System Volume | ~1.2 L |
| Dual Separation Vessels | 350 mL each (max 300 mL liquid holdup per vessel) |
| Dimensions | 1300 × 700 × 1800 mm |
| Power Supply | 220 V AC / 32 A, ≤6.5 kW (including light source) |
| Interface | Metric 3 mm Swagelok®-compatible fittings |
| Brand | PerfectLight (PerfekLight) |
|---|---|
| Origin | Beijing, China |
| Model | PLR-PTSR II |
| Reaction Pressure | 1.6 MPa (gauge) |
| Maximum Reaction Temperature | 550 °C |
| Catalyst Bed Volume | 12 mL |
| Reactor Material | 304 Stainless Steel |
| Optical Window Transmission Range | 0.19–5 μm |
| Optical Window Diameter | Ø35 mm |
| Gas Volume (Differential Mode) | ~35 mL |
| Gas Volume (Integral Mode) | ~27 mL |
| Liquid Loading Capacity | ≤1.5 mL |
| Catalyst Forms | Powder-on-membrane or porous disc (Ø51 mm, ≤5.5 mm thick) |
| Membrane Support Size | Ø37–Ø50 mm, effective area ≥Ø35 mm |
| Mass Flow Control Range | 3–60 mL/min, ±1% FS |
| Pressure Control Range | 0.3–1.6 MPa (gauge), ±0.25% FS |
| Temperature Control Range | Ambient to 550 °C (N₂), resolution ±0.1 °C |
| Heating Modes | Electric, Photoirradiation, or Coupled Photothermal |
| Temperature Program | Up to 8 segments (isothermal, constant-power, or ramped profiles) |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR-QY1000 |
| Light Source | 405 nm Laser Diode (standard), optional wavelengths available |
| Reaction Volume | ~150 mL internal headspace (calibration-dependent) |
| Liquid Sample Volume | 100 mL (adjustable range) |
| Pressure Range | 20–130 kPa (absolute) |
| Purge Gas | N₂, delivery pressure 0.4–0.45 MPa |
| Purge Cycles | 0–255 programmable |
| Residual O₂ | ≤100 ppm after purge |
| Stirring Speed | 250–1250 rpm |
| Temperature Control | 0–60 °C (via external circulating chiller) |
| Humidity & Temperature Monitoring | Integrated in-situ sensors |
| Quantum Yield Range | 0.05%–100% |
| Data Export | USB flash drive interface |
| Compliance | Designed for ISO/IEC 17025-aligned photocatalytic testing workflows |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 6A Liquid-Phase |
| Pricing | Upon Request |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | μGAS1000 |
| Vacuum Integrity | ≤0.5 kPa (absolute) |
| System Volume | 440 mL |
| Reactor Volume | 210 mL (recommended working volume: 40–80 mL) |
| Gas Loop Volume | 230 mL |
| Tubing Material | Borosilicate glass (3 mm ID narrow sections) |
| Valve Count | 6 |
| Vacuum Grease | Apiezon H (−10 °C to +200 °C) |
| Gas Mixing Time (H₂/O₂/CO₂) | <10 min |
| Linearity (R²) | >0.999 |
| Repeatability (RSD, n=4) | <3% |
| Pressure Resolution | 1 Pa |
| Temperature Resolution | 0.01 °C |
| Max Carrier Gas Pressure | >0.5 MPa |
| Heating Capability | Up to 120 °C (loop & sampling lines) |
| Sampling Quantitation Options | 0.5 / 1 / 2 / 3 / 5 mL loops |
| Detection Compatibility | GC-integrated, software-controlled auto-sampling and background gas injection |
| Software | PC-based control with real-time logging, ASTM/ISO-compliant data export (.xlsx), GLP-ready audit trail, automated dynamic leak testing, preheat function to prevent valve seizure |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PEC2000 |
| Reaction Pressure | Ambient (0 bar gauge) |
| Reaction Temperature | Room Temperature (20–25 °C) |
| Catalyst Loading Capacity | Not Applicable (Flow-through / Immobilized Electrode Configuration) |
| Light Source Power | 300 W (Adjustable 150–300 W) |
| Illumination Uniformity | ≤3% |
| Long-term Intensity Drift | ≤2% |
| Spectral Range | 350–800 nm |
| Effective Irradiation Area | 10×10 to 50×50 mm² |
| Irradiance | Up to 3000 mW/cm² |
| Optical Power Measurement Range | 0–20 W (Accuracy: ±1 mW) |
| Chopping Interval | 1 s – 30 min |
| X-axis Translation Range (Chamber) | 0–80 mm |
| Y-axis Translation Range (Turntable) | 0–10 mm |
| Electrochemical Compatibility | Three-electrode configuration (working, counter, reference), integrated gas-tight lid |
| Reactor Volume | 180 mL (Effective Liquid Volume ≈90 mL) |
| Photodetector Spectral Response | 0.2–11 μm |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | μGAS1001 |
| Pressure Range | 0 kPa to ambient pressure (gauge) |
| Temperature Control Accuracy | ±0.01°C |
| System Total Volume | 440 mL |
| Reactor Volume | 210 mL (recommended working volume: 40–80 mL) |
| O₂ Leak Rate | ≤0.1 μmol/h |
| Quantitative Loop Options | 0.5, 1, 2, 3, 5 mL |
| Maximum Sampling Ratio | 1:88 |
| Vacuum Base Pressure | ≤0.5 kPa (absolute) |
| Tubing Material | High-borosilicate glass |
| Valve Technology | Patented all-glass, metal-free rotary valve island |
| Circulation Pump | Contactless magnetic-drive fan impeller pump (intrinsically safe for H₂ environments) |
| GC Interface | Fully automated, bidirectional TTL/RS-485 control of GC and vacuum pump |
| Brand | PerkinElmer (Note: “泊菲莱/PerfectLight” is a Chinese brand |
|---|---|
| Origin | Beijing, China |
| Model | PLR RVTF-PM |
| Reaction Pressure Range | 0.1 (gauge) – 5.5 MPa |
| Reaction Temperature Range | 180 – 1050 °C (externally controlled, stability ≤ ±1 °C) |
| Catalyst Bed Volume | 0.1 – 0.5 mL (bed height: 1–5 mm) |
| System Footprint | 900 × 600 × 1000 mm |
| Power Supply | 220 V AC / 16 A, ≤ 3 kW |
| Gas Inlets | 2 standard (expandable to 4), max flow 100 mL/min per channel |
| Backpressure Control | Integrated 6 MPa sensor (0.2% FS accuracy, 1 kPa resolution) |
| Reactor Type | Top-illuminated high-pressure photo-thermal fixed-bed reactor with quartz liner & light-guiding column |
| Heating Zone | Ceramic fiber furnace |
| Condensate Separator Volume | 60 mL |
| Total System Volume | ~200 mL |
| Optional Features | 100-segment flow programming, Wi-Fi-enabled remote monitoring & PLC firmware updates, intelligent IoT remote operation |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | Labsolar-6A Gas-Phase |
| Construction Material | Borosilicate Glass (Duran®-grade) |
| Gas Circulation Time | <10 min for H₂, O₂, CH₄, CO |
| Oxygen Leakage Rate | ≤0.1 μmol/h |
| Detection Limits (� | mol): H₂: 0.05 |
| O₂ | 0.1 |
| CH₄/CO | 0.0005 |
| Quantitative Loop Options | 0.6 mL or 2 mL |
| System Volume | 65 mL |
| Operating Pressure Range | 0 kPa (vacuum) to ambient pressure |
| Vacuum Degree | ≤1.5 kPa (absolute) |
| Temperature Control | 10-segment programmable, ±0.1°C accuracy, up to 200°C |
| Valve Count | 7 |
| Sealing Medium | Dow Corning® High-Vacuum Grease (-40–200°C) |
| Compliance | Designed for GLP-compliant catalyst evaluation under ASTM E2500 and ISO/IEC 17025-aligned workflows |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | PLR-SYTC |
| Reaction Pressure Range | 0–0.15 MPa (gauge) |
| Reaction Temperature Range | Ambient to 400 °C |
| Catalyst Bed Volume | 50 mL (customizable: 25/100/200 mL) |
| Reactor Body Material | 304 Stainless Steel |
| Optical Window | Ø47.5 mm JGS1 Fused Silica (Transmittance >97% from 190–2500 nm) |
| Heating Method | Integrated Resistive Heating Element with PID Feedback Control |
| Temperature Sensing | Type K Thermocouple, ±0.1 °C Accuracy |
| Temperature Stability | ±0.5 °C |
| Gas Interface | High-Pressure Metal Push-to-Connect Fittings (Inlet/Outlet/Vacuum/Manual Sampling) |
| Power Monitoring | Real-time Electrical Energy Consumption Logging |