Empowering Scientific Discovery

Beijing Perfectlight Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
ModelLabsolar-6A Online Photocatalytic Analysis System
Reaction Vessel Count1
Reaction Volume65 mL
Vacuum Tightness≤1 μmol/24 h (O₂)
Gas Mixing Time (H₂/O₂/CH₄/CO)<10 min
Quantitative Loop Options0.6 mL or 2 mL
System Tubing Volume65 mL
Absolute Vacuum Level≤1.5 kPa
Operating Pressure Range0 kPa to atmospheric
Valve Count7
Tubing MaterialHigh-Borosilicate Glass
Temperature Control Range (Tubing & Sampling Lines)Up to 200 °C (10-segment programmable, ±0.1 °C accuracy)
Detection Limits (�mol): H₂: 0.05
O₂0.1
CH₄/CO0.0005
Repeatability (RSD)<3% for quadruplicate injections
Linearity (H₂, 100 �L–10 mL): R² > 0.9995
Exhaust Volume per Cycle6 mL
Pump TypePassive Magnetic-Drive Plunger Pump (wire-free, no H₂ evolution risk, unidirectional flow)
Sampling MethodFixed-volume loop integrated in multi-port glass sampling valve (non-chromatographic)
CondenserSpherical or coiled type
EnclosureMetal safety cabinet with portable light-shielding hood
Software32-bit control suite + 4.5″ TFT color touchscreen
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfetLight
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelPLS-STAS-I Series
PriceUSD 1 (FOB Inquiry Required)
Tracking MethodHybrid Optical + Astronomical Time-Based Tracking
Elevation Range0–90°
Azimuth Range−110° to +110° (0° = True South)
Optical Tracking Accuracy< 0.3°
Time-Based Tracking Accuracy< 1.0°
Fresnel Lens Area0.2 m²
Minimum Focal Spot Area7 cm²
Concentration Ratio278×
Operating Temperature Range−25°C to +55°C
Ambient PressureAtmospheric
Gas Collection Capacity300 mL / 500 mL gas sampling bags
Incident Photon Flux Density Monitoring≤10 W/cm² (photochemical irradiance at reaction plane)
Environmental MonitoringDirect/Global Solar Irradiance, Ambient Temperature, Relative Humidity, Barometric Pressure, Wind Speed
IP RatingIP67
Wind Resistance ClassBeaufort Scale Level 6
Safety FeaturesEnd-Position Limit Switches, Wind-Induced Auto-Stow Protocol, Rain Detection & Hibernation Mode
Control ArchitectureIntegrated PLC with GPS Geolocation & Real-Time Ephemeris Calculation
Data LoggingTimestamped Elevation/Azimuth Angles, Irradiance Values, Environmental Parameters, Derived Solar Positional Metrics
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfecLight
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelWLK-1000
PricingAvailable Upon Request
Light Source Wavelength Range255–760 nm (Multi-wavelength Selectable)
Optical Power Output10–120 W (Adjustable)
Temperature Control Range−20 to +80 °C (Precision Thermostatic Regulation)
Reaction Volume per Chip Unit5 µL / 10 µL
Liquid Flow Rate0.1–70 mL/min
Compatible PhasesLiquid–liquid (homogeneous & heterogeneous)
Chip Substrate MaterialsFused Silica, Borosilicate Glass, PDMS, Polymer
Footprint620 mm × 540 mm × 430 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
ModelPLR-50
Reaction Volume50 mL (customizable: 25/100 mL)
Operating TemperatureRT+10°C to 300°C (up to 380°C transient)
Operating Pressure1–10 MPa
Gas Inlets3 independent channels
Total Gas Flow Range1–60 mL/min
Safety Relief Valve SetpointAdjustable up to 7 MPa
Integrated High-Pressure Gas Mixing Chamber1 L
Flow MonitoringElectronic Soap Film Flowmeter (10–60 mL/min)
Optical WindowThick-wall fused quartz, UV–Vis–NIR transparent (190–2500 nm)
Safety EnclosureIntegrated blast-resistant cabinet with interlocked access
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelPQ256
PricingUpon Request
Reactor TypeTop-Illumination Photoreactor
Optical WindowJGS-2 Fused Quartz (Flat Plate or Double-Wall Quartz Jacket Options)
Reactor Body400 mL Borosilicate Glass
Effective Reaction Volume~250 mL
SealingFlanged Connection with Viton/EPDM O-Ring Seal
Gas Inlet/Outlet PortsEquipped with Precision Needle Valves
Liquid Sampling PortGlass External Thread + Silicone Septum (Non-Invasive Sampling)
Gas Purge CapabilityDual Inlet/Outlet for Inert/Reactive Atmosphere Control
Optional Add-onsStandard Tapered Ground-Joint Expansion Ports (e.g., 14/20, 24/29), Glass Ball Valves, Additional Sampling Valves, Custom-Mounted Thermocouple Wells
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
Model6A
Valve MaterialHigh-Borosilicate Glass
ActuationPneumatic/Electric Auto-Actuators
Gas Mixing Time<10 min (H₂, O₂, CH₄, CO)
Calibration LinearityR² > 0.9995 (H₂: 100 μL–10 mL)
RepeatabilityRSD < 3% (n = 4)
Sampling Volume0.6 mL or 2.0 mL (selectable)
System Dead Volume65 mL
Vacuum Tightness≤1 μmol O₂/24 h
Absolute Vacuum Limit≤1.5 kPa
Operating Pressure Range0 kPa (vacuum) to ambient pressure
Pump TypeOil-Free Magnetic-Drive Piston Pump (no electrical wiring in gas path)
Flow Direction ControlIntegrated Unidirectional Valve Architecture
Temperature Control10-Stage Programmable, ±0.1 °C accuracy, up to 200 °C (loop & injection lines)
CondenserSpherical or Coiled Glass Cold Trap (standard), Optional Cryogenic Cold Trap
Detection Limits (�mol): H₂: 0.05
O₂0.1
CH₄/CO0.0005
Software32-bit Embedded Control Suite + 4.5″ TFT Touchscreen
ComplianceASTM E2500, ISO/IEC 17025-aligned architecture, GLP-ready audit trail logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelLabsolar-IIIAG
PricingAvailable Upon Request
Vacuum Level≤0.1 MPa (absolute)
Operating Pressure Range0 kPa to ambient pressure
Gas Tightness≤1 kPa pressure change over 24 h
Tubing MaterialHigh-borosilicate glass
Minimum Tubing ID3 mm
Total System Volume150 mL
Sampling Loop Volume1.5 mL
Gas Storage Vessel250 mL
Condenser TypeSpherical condenser
Cold TrapIntegrated for low-boiling component separation
Vacuum PumpSingle-stage rotary vane pump, pumping speed ≥6 L/s
Magnetic Circulator Speed≥4000 rpm
H₂ Calibration LinearityR² > 0.999 in range 100 μL–10 mL
Repeatability (RSD)<3% for quadruplicate injections
Valve Count13
Valve MaterialHigh-borosilicate glass with precision lapped plug-and-body
Vacuum GreaseDow Corning high-performance vacuum grease (–40°C to 200°C, low vapor pressure, chemical resistant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPLR-GSPR
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
ModelPLR RVTF-POX
Reaction Pressure Range0.2 (gauge) – 6 MPa
Reaction Temperature Range80 – 600 °C
Catalyst Bed Volume0.2 – 0.8 mL
Reactor TypeQuartz fixed-bed with metallic outer jacket and integrated light-conducting optics
Heating ConfigurationDual-channel, three-zone furnace with 16-segment programmable ramp/soak profiles
Gas Flow ControlThree independent mass flow controllers (500/200/200 mL/min, 4–100% FS, ±1% FS accuracy)
Liquid Flow Rate0.001–4.999 mL/min (water-compatible)
Preheating Temp Range50–400 °C (16-segment program)
Trace Heating150–240 °C
Total System Volume~1.2 L
Dual Separation Vessels350 mL each (max 300 mL liquid holdup per vessel)
Dimensions1300 × 700 × 1800 mm
Power Supply220 V AC / 32 A, ≤6.5 kW (including light source)
InterfaceMetric 3 mm Swagelok®-compatible fittings
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
ModelLabsolar-IIIAG
Temperature Range−40 °C to 200 °C
Reaction Vessel Count1
Reaction Volume150 mL
Vacuum Level≤0.1 MPa (absolute)
Gas Loop Flow Path ID3 mm
Quantitative Loop Volume1.5 mL
Gas Storage Bottle Capacity250 mL
Condenser TypeSpherical Reflux Condenser
Cold TrapIntegrated
Vacuum PumpSingle-Stage Rotary Vane, ≥6 L/s
Valve Count13
Sealing GreaseDow Corning High-Performance Vacuum Grease (−40 °C to 200 °C)
Construction MaterialBorosilicate Glass (3.3), Chemically Inert
Gas SamplingManual Online Sampling via Glass Multi-Position Valve with Quantitative Loop
Magnetic Drive Circulation PumpBrushless, Wire-Free, ≥4000 rpm
Linearity (H₂)R² > 0.999 (100 μL–10 mL)
Repeatability (RSD)<3% (n=4)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
Reactor TypeTubular Fluidized-Bed Photoreactor
Effective Reaction Volume~1 L (customizable)
Operating TemperatureAmbient
Operating PressureAtmospheric
Temperature ControlJacketed Water Bath
Solid Catalyst Loading CapacityUp to 100 g per run
Fluidization ControlAdjustable Flow Rate & Cycle Timing
Particle Size Range>3 mm (recommended)
Reservoir Tank Volume5 L
Light Source350 W UV-LED Array
Wavelength385 nm (optional wavelengths available)
Light Intensity Control10–99.99% stepless dimming
Cabinet Dimensions1000 × 700 × 1840 mm
Net Weight~100 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic Scientific Instrument
ModelPLR-SCR100A
PricingUpon Request
Max Operating Pressure3 MPa (≤300 °C) / 1 MPa (≤600 °C)
Max Temperature600 °C
Temperature Stability±1 °C
Pressure Accuracy±0.2 % F.S.
LED Wavelength Options365, 380, 405, 420, 760 nm (customizable)
Microwave Output~250 W (solid-state, real-time forward/reflected power monitoring)
Heating Rate (Joule)up to 100 °C/min
Thermal Equilibration Time~15 min
Gas Inlets3 standard (4 optional), 100 mL/min N₂ calibration flow
Liquid Inlet0–1 channel, 0.001–2 mL/min
Preheater Max Temp400 °C
Condenser Volume≤50 mL, detachable
Power Supply220 V/10 A, <2.2 kW, grounded
Dimensions (W×H×D)700 × 800 × 480 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
ModelPLR-SPR Series
TypeLaboratory-to-Industrial Flat-Plate Photoreactor
Reactor Area (PLR-SPRL)0.0025–0.0625 m²
Reactor Area (PLR-SPRF)0.1–0.5 m²
Reactor Area (PLR-SPRG)0.5–10 m²
Flow Rate Range0–120 L/min
Liquid Reservoir Capacity0.2–1000 L
Construction MaterialsPTFE, SS316, PP-R, PU
ComplianceDesigned for ISO/IEC 17025-aligned photoreactor validation and GLP-compliant solar fuel research
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
ModelPLR-MFPR-I
Temperature RangeAmbient to 180 °C
Temperature Control Accuracy±0.5 °C
Operating Pressure Range−50 kPa to 0.9 MPa (gauge), 50 kPa to 1.0 MPa (absolute)
Reaction Volume100 mL (total internal volume: 120 mL)
Sampling Volume100 µL per cycle
Minimum Sampling Interval3 min
Magnetic Stirring Speed200–1500 rpm, precision ±1 rpm
Optical WindowSapphire, transmission >97% from 190 nm to 5 µm, clear aperture 27.5 mm
Reactor ConstructionStainless steel outer body with chemically inert borosilicate glass liner rated for 0.9 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight (PerfekLight)
OriginBeijing, China
ModelPLR-PTSR II
Reaction Pressure1.6 MPa (gauge)
Maximum Reaction Temperature550 °C
Catalyst Bed Volume12 mL
Reactor Material304 Stainless Steel
Optical Window Transmission Range0.19–5 μm
Optical Window DiameterØ35 mm
Gas Volume (Differential Mode)~35 mL
Gas Volume (Integral Mode)~27 mL
Liquid Loading Capacity≤1.5 mL
Catalyst FormsPowder-on-membrane or porous disc (Ø51 mm, ≤5.5 mm thick)
Membrane Support SizeØ37–Ø50 mm, effective area ≥Ø35 mm
Mass Flow Control Range3–60 mL/min, ±1% FS
Pressure Control Range0.3–1.6 MPa (gauge), ±0.25% FS
Temperature Control RangeAmbient to 550 °C (N₂), resolution ±0.1 °C
Heating ModesElectric, Photoirradiation, or Coupled Photothermal
Temperature ProgramUp to 8 segments (isothermal, constant-power, or ramped profiles)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
ModelPLR-QY1000
Light Source405 nm Laser Diode (standard), optional wavelengths available
Reaction Volume~150 mL internal headspace (calibration-dependent)
Liquid Sample Volume100 mL (adjustable range)
Pressure Range20–130 kPa (absolute)
Purge GasN₂, delivery pressure 0.4–0.45 MPa
Purge Cycles0–255 programmable
Residual O₂≤100 ppm after purge
Stirring Speed250–1250 rpm
Temperature Control0–60 °C (via external circulating chiller)
Humidity & Temperature MonitoringIntegrated in-situ sensors
Quantum Yield Range0.05%–100%
Data ExportUSB flash drive interface
ComplianceDesigned for ISO/IEC 17025-aligned photocatalytic testing workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPufeiLai (PerfectLight)
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelULTRA-SONIC COUPLED DUAL-CHAMBER ELECTROLYSIS CELL
PriceUpon Request
Ultrasonic Frequency40 kHz
Ultrasonic Power Range0–60 W per channel (dual independent channels)
Temperature Monitoring Range0–80 °C
Timer Range0–99 min
Chamber ConfigurationDual-compartment, dual-electrode
Electrode Active Area (Standard)2 × 2 cm²
Housing Material2 mm anodized aluminum
Dimensions (W × D × H)155 × 365 × 330 mm
Operating EnvironmentNon-condensing, ambient pressure, ≤60 °C
Ultrasonic Transducer MountingThreaded stud + structural epoxy bonding
Fluidic InterfaceDual inlet/dual outlet (optional)
Optical CompatibilitySingle-chamber replaceable with quartz window + metal body for sonophotoelectrocatalysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelLabsolar-6A
Reactor Volume150 mL (excl. reactor cavity)
Construction MaterialBorosilicate glass
Operating Pressure Range0 kPa to atmospheric pressure
Ultimate Vacuum≤1.5 kPa (absolute)
Vacuum Leakage Rate≤1 μmol O₂/24 h
Gas Mixing Time<10 min (H₂, O₂, CH₄, CO)
Quantitative Loop Options0.6 mL or 2 mL
Circulation Line ID3 mm
Total System Dead Volume65 mL
Temperature Control RangeAmbient to 200 °C (10-segment programmable, ±0.1 °C accuracy)
Detection Limits (�mol): H₂: 0.05
O₂0.1
CH₄/CO0.0005
Repeatability (RSD)<3% (n=4)
Linearity (R²)>0.9995 (H₂: 100 μL–10 mL)
Displacement per Cycle6 mL
Pump TypePassive magnetic-drive piston pump (wire-free, no electrolytic H₂ interference)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight (PofeiLai)
OriginBeijing, China
ModelPLR-HGPR
Temperature RangeAmbient +10 °C to 300 °C (up to 380 °C)
Operating Pressure1–10 MPa
Reactor Volume50 mL (customizable: 25 mL or 100 mL)
Gas Inlets3 independent channels
Total Gas Flow Rate1–60 mL/min
Safety Relief Valve SetpointAdjustable up to 7 MPa
Gas Mixing Chamber Volume1 L
Flow MonitoringElectronic soap-film flowmeter (10–60 mL/min range)
Optical WindowThick fused-silica quartz, broadband transmission (190–2500 nm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
ModelPLR-HGPR
Temperature RangeAmbient +10 °C to 300 °C (up to 380 °C)
Operating Pressure1–10 MPa
Reactor Volume50 mL (customizable: 25 mL or 100 mL)
Gas Inlets3 independent channels
Total Gas Flow Rate1–60 mL/min
Safety Relief Valve SetpointAdjustable up to 7 MPa
Gas Mixing Chamber Volume1 L
Flow MonitoringElectronic soap-film flowmeter (10–60 mL/min range)
Optical WindowThick fused-silica quartz, transmission range: 190–2500 nm
Pressure & Temperature DisplayIntegrated digital panel meters
EnclosureIntegrated safety-rated protective cabinet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
ModelPLR PTCS-31
Power SupplyAC 220 V, 50/60 Hz
Total Power1500 W (LED source: 900 W
Water cooling600 W)
Maximum Achievable Temperature≥500 °C (center zone, ±5 cm)
Reaction Tube DimensionsΦ10 × Φ7 × 400 mm (quartz glass standard
Collector Tube DimensionsΦ58 × Φ43 × 330 mm
Collector Tube MaterialHigh-borosilicate glass with selective solar-absorbing coating
Long-term Operating Temperature Range (collector)5–300 °C
Short-term Exposure Limitup to 500 °C (coating degradation risk above 300 °C)
Illumination Uniformity>90% across irradiated surface
Peak Irradiance≥300 mW/cm² (at 1-sun equivalent, initial condition)
Spectral ControlThree-zone independently adjustable LED array (UV–vis–NIR)
Temperature MonitoringMulti-point thermocouple interfaces along U-shaped reaction tube
CoolingIntegrated closed-loop water circulation system
Ambient Operating Conditions0–45 °C, non-condensing
Storage Conditions−10–60 °C, 30–85% RH (drain coolant before storage below 0 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
ModelPLR-SPRG
Reactor TypePlanar Flow-Through Photoreactor
Construction MaterialStainless Steel (316L)
Effective Illuminated Area per Unit0.5 m²
Scalable Array SizeUp to 100 m² (modular configuration)
Liquid Layer Thickness1–5 mm
Reactor Tilt Angle Adjustment0–90° continuous
Liquid Flow Rate0–200 mL/min
Carrier Gas Flow Rate4–100 mL/min
Operating Temperature RangeAmbient to 60 °C
Maximum Operating Pressure≤50 kPa (gauge)
Gas Recirculation Pump Capacity10–50 L/min
Wetted MaterialsPA66, PMMA, PP, Fluoroelastomer
Control SystemIntegrated PLC with HMI touchscreen interface
Monitoring ParametersFlow rate, pressure, pH, ORP, temperature, gas evolution volume
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
ModelPLR MFPR-I
Temperature RangeAmbient to 180 °C
Temperature Control Accuracy±0.5 °C
Operating Pressure Range−50 kPa to 0.9 MPa (gauge), i.e., 50–1000 kPa (absolute)
Reaction Vessel MaterialStainless Steel with Borosilicate Glass Liner
Effective Reaction Volume100 mL (total internal volume: 120 mL)
Automatic Gas Sampling Pressure Range80–900 kPa (absolute)
Minimum Sampling Interval3 min
Sample Volume per Injection100 μL
Gas Consumption per Sampling Cycle~0.5 mL
Magnetic Stirring Speed200–1500 rpm
Stirring Accuracy±1 rpm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerfectLight
OriginBeijing, China
ModelPLR OTPR-I
TypeIn-situ thermometric, gas-permeating photocatalytic reactor for solid-phase catalysts
CompatibilityDesigned for integration with Labsolar-6A all-glass automated micro-gas analysis system (OTPR-1 variant) or continuous-flow photo(thermal)catalytic setups (OTPR-2 variant)
Thermal ManagementIntegrated thermostatic jacket + non-contact IR temperature monitoring port
Gas Flow ModeForced-through (transmissive) configuration
Sample FormsPowder, porous thin films, and low-thickness monolithic catalysts
Primary FunctionReal-time surface temperature measurement during irradiation-driven gas-solid reactions
Compliance ContextEngineered for GLP-aligned photocatalysis research