Biological Microscope/In Vivo Imaging
Filter
Showing 241–270 of 424 results
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | RM21™ Microscope Platform |
| Instrument Type | Inverted Fluorescence Microscope |
| Excitation Source | Metal Halide Lamp |
| Eyepiece Compatibility | Standard 23.2 mm or 30 mm Mounts |
| Objective Compatibility | Standard RMS or M25 Thread Mounts |
| Fluorescence Configuration | Epi-illumination (Reflected Light) |
| Illumination Flexibility | Compatible with Broadband, LED, and Laser Sources |
| Observation Geometry | Inverted Optical Layout |
| Z-Axis Travel | 50 mm (2 in) with 95 nm Step Resolution |
| XY Positioning | Manual or Motorized Micropositioner (Optional) |
| Encoder Option | Closed-Loop Encoders Available for X, Y, and Z Axes |
| Integration Ready | Fully Compatible with Nano-Cyte® 3D Stability System, Nano-LPS/Nano-LPQ Linear Positioners, Nano-OP/Nano-F Objective Positioners, and LCC-Focus™ Autofocus Modules |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TIRF Lock™ |
| Instrument Type | Inverted Fluorescence Microscope Add-on Module |
| Excitation Source | Metal Halide Lamp |
| Eyepiece | Standard |
| Objective | Standard |
| Fluorescence Configuration | Epi-Fluorescence |
| Compatible Light Sources | Any Illumination Source |
| Observation Head | Inverted |
| Wavelength Range | 400–1000 nm |
| Peak Responsivity | 0.4 A/W @ 635 nm, 0.67 A/W @ 900 nm |
| Recommended Input Beam Diameter | 300 µm – 1.5 mm |
| Sensor Active Area | 2.4 mm × 2.4 mm |
| Clear Aperture | 12.5 mm (0.5 inch) |
| Aperture Threading | SM05 (0.535-40) |
| Detector Head Mounting Thread | 8-32 or M4 |
| Base Mounting Thread | 1/4-20 or M6 (magnetic base & clamping fork included) |
| Detector Cable Length | 1.83 m (6 ft) |
| Power Supply | 90–260 V AC |
| Controller Dimensions | 212.7 mm × 88.9 mm × 304.8 mm (8.375″ × 3.5″ × 12″) |
| PC Interface | USB 2.0 |
| OS Compatibility | Windows XP Pro / Vista / 7 / 8 (32- or 64-bit) |
| Brand | Lifecanvas Technologies |
|---|---|
| Origin | USA |
| Model | MegaSPIM |
| Illumination Geometry | 45° Unilateral Light Sheet Generation with Axial Sweeping (Patent US10989661B2) |
| Sample Chamber Dimensions | >200 mm × 200 mm (X–Y), 50 mm Z-Travel for Specimen Positioning |
| Detection Objective EFL | 180 mm Tube Lens |
| Standard Objective | 3.6×, Large-Field-of-View |
| Optional Objectives | 1.8×, 9×, 15×, 22× |
| Camera | 2048 × 2048 sCMOS, Rolling Shutter Synchronized with Light Sheet Sweep, QE = 82%, Max Frame Rate: 80 fps |
| Dual-Camera Acquisition | Optional, Independently Focused |
| Laser Lines | Standard 3, Expandable to 7 (405–785 nm) |
| Acquisition Workstation | Intel® Core™ i9-12900K (16C/24T), 128 GB Quad-Channel DDR5 RAM, 32 TB Storage (4 × 8 TB Samsung 870 QVO SATA III SSD), Windows 10 Pro, 4K Display |
| Software | MegaSPIM Acquisition & Post-Processing Suite (Real-Time Tile Correction, Stripe Artifact Suppression, GPU-Accelerated 3D Volume Reconstruction, Block-Based Registration) |
| Analysis Workstation (Optional) | AMD Ryzen™ Threadripper PRO 3995WX (64C/128T), 512 GB Quad-Channel DDR4 RAM, 32 TB RAID 0 (4 × 8 TB 7200 RPM HDD), Windows 10 Pro |
| Brand | Micro-Field / Guangzhou Micro-field Optical Technology Co., Ltd. |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HM-SR-01 |
| Imaging Modality | dSTORM (direct Stochastic Optical Reconstruction Microscopy) & TIRF (Total Internal Reflection Fluorescence) |
| Objectives | Plan-Apochromat 40×/0.95 (WD: 0.25–0.16 mm) |
| Apochromat 100×/1.45 Oil (WD | 0.13 mm) |
| Excitation Lasers | 405 nm (60 mW), 432 nm (80 mW), 488 nm (20 mW), 561 nm (80 mW), 638 nm (60 mW) |
| Focus Stability | Active autofocus with ≤50 nm axial drift correction |
| Z-Stage | Closed-loop nanopositioning stage (150 µm travel, 0.8 nm resolution) |
| XY-Stage | Motorized stage (110 × 75 mm travel, ±1 µm repeatability) |
| Camera Interface | High-sensitivity scientific CMOS or EMCCD compatible |
| Dimensions | 840 × 345 × 750 mm |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SpectraMax MiniMax 300 Cell Imaging System |
| Instrument Type | Optical Imaging System |
| Compatibility | Designed exclusively for integration with SpectraMax i3x Multi-Mode Microplate Readers |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Momentum |
| Instrument Type | Tomographic Imaging |
| Energy Resolution | 1.4–5.3 mT |
| Spatial Resolution | 100 µm |
| Scan Speed | 10 s per volume |
| Field of View (FOV) | 6 cm × 6 cm × 12 cm |
| Sample Capacity | 1 animal |
| Brand | Motic |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MV200 |
| Instrument Type | Inverted Microscope |
| Optical Design | Plan Phase Contrast Objective with Multi-layer Broadband Coating |
| Tube Lens | Fully Achromatically Corrected |
| Illumination | Integrated 12 V / 3 W LED |
| Condenser | Adjustable Aperture Diaphragm (N.A. 0.1–0.3) |
| Digital Integration | Built-in Digital Imaging Options (MV200-B, MV200-D, MV200-i, MV200-S variants) |
| Application Focus | Live-cell Observation, Tissue Culture, Microbiology, Immunology, Medical Education |
| Brand | Nanolive |
|---|---|
| Origin | Switzerland |
| Model | 3D Cell Explorer / 3D Cell Explorer-fluo |
| Resolution | 400 nm (lateral), 500 nm (axial) |
| Field of View | 90 × 90 µm² (2D), 90 × 90 × 30 µm³ (3D volume) |
| Objective | Dry, 60×, NA 0.8 |
| Illumination | High-speed tunable laser source (multiple wavelengths, <1 ms switching) |
| Imaging Principle | Quantitative Phase Tomography (QPT) based on interferometric digital holography |
| Acquisition Speed | Full 3D tomogram in ≤2 seconds |
| Software Platform | STEVE v5.x (with cloud-synced analysis modules) |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model Variants | MTK-1/O1/O2/O3/N1/N2/N3/N4/Z1/Z2/L2 |
| Compatibility | Inverted Microscopes (Olympus IX70/IX71/IX73/IX83, Nikon TE2000/Ti/Ts2R/Ti2, Zeiss Axiovert 200/Observer 3–7/Axio Vert.A1, Leica DMi8) |
| Motion Control | Hydraulic (X/Y/Z/Rotation) |
| Positioning Resolution | X/Y/Z: 5 µm (fine), 250 µm (coarse) |
| Rotation | 20 µm (fine), 1000 µm (coarse) |
| Return-to-Origin Function | Mechanical + Hydraulic Memory |
| Angular Range | 15°–40° |
| Pipette Tip Retraction Margin | 50 mm |
| Weight | Control Unit ~1.9 kg |
| Hydraulic Tubing Length | 0.6 m |
| Included Accessories | Microscope-Specific Mounting Adapters, IP-Plate ×2, Hex Wrench, Anchor ×2, Pipette Ruler ×2 |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | PC-100 |
| Pulling Modes | Single- and Double-Pull |
| Tip Diameter Range | 0.1 µm (single-pull) to several–tens of µm (double-pull) |
| Capillary Compatibility | 1.0–1.5 mm OD glass capillaries |
| Heating Control | Digital voltage display with voltage stabilization |
| Preheating Function | Yes |
| Pulling Environment | Enclosed draft-free chamber |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Brand | Nexcope |
|---|---|
| Model | NSR950 |
| Technology | Structured Illumination Microscopy (SIM) |
| Laser Wavelengths | 405 nm, 488 nm, 561 nm, 640 nm |
| Lateral Resolution | ≤86 nm (TIRF-SIM), ≤115 nm (3D-SIM) |
| Field of View | Square inscribed in Φ22 mm |
| Imaging Speed | 120 fps |
| Eyepieces | 10× (25 mm field number), EP 17.5 mm, diopter adjustment range −5 to +5 |
| Objectives | 10×, 20×, 40×, 60×, 100× |
| Brand | NIKON |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | E100, EI |
| Instrument Type | Upright Microscope |
| Eyepiece Configuration | Binocular |
| Optical System | CFI Infinity-Corrected |
| Magnification Range | 40×–1500× |
| Illumination | 6 V / 20 W Halogen Lamp with Condenser |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment (Coarse Travel: 22 mm |
| Coarse Rotation | 37.7 mm/rev |
| Fine Rotation | 0.2 mm/rev |
| Minimum Graduation | 2 µm) |
| Eyepiece Tube | E2-TB Binocular (30° Inclination, 360° Rotatable, Interpupillary Distance: 47–75 mm) |
| Condenser | Abbe Condenser, NA 1.25, Filter Holder for 33 mm Filters (Including Standard Blue Filter) |
| Objective Turret | 4-Position, Mechanical Centering, Multi-Ball Bearing Rotation |
| Objectives | Plan Achromat 4×, 10×, 40×, 100× (Anti-Fungal Coating) |
| Stage | Dual-Layer Mechanical Stage (155 × 134 mm), Graduated Movable Slide Clips |
| Weight | ~7.3 kg |
| Power Consumption | 50 W |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Microscope Type | Upright Biological Microscope |
| Model | E200 |
| Optical System | CFI60 Infinity-Corrected |
| Magnification Range | 40×–1000× |
| Eyepiece Tube | E2-TB Binocular (hinged, 30° inclination) or E2-TF Trinocular (30° inclination, 360° rotation, interpupillary distance 47–75 mm) |
| Eyepieces | CFI E10×/20 mm (field number 20 mm), optional CFI 15×/12 mm |
| Objectives | CFI E Plan Achromat 4× (NA 0.10), 10× (NA 0.25), 40× (NA 0.65), 100× oil (NA 1.25) |
| Nosepiece | Internal quadruple revolving nosepiece |
| Stage | Rectangular mechanical stage (216 × 150 mm), X–Y travel 78 × 54 mm, low-position coaxial controls, auto-return focusing mechanism |
| Condenser | E2 Abbe condenser (NA 1.25) with iris diaphragm and objective position markers |
| Illumination | 6 V / 20 W halogen lamp, centerable and height-adjustable |
| Focus Mechanism | Coarse focus (37.7 mm per revolution), fine focus (0.2 mm per revolution, 2 µm graduation), adjustable coarse torque, built-in stage stop for high-magnification protection |
| Compliance | Designed for ISO 10993-5 biocompatibility of user-contact components |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Microscope Type | Upright Biological Microscope |
| Configuration | Binocular |
| Illumination | High-Efficiency White LED (60,000 hr lifetime) |
| Optical System | CFI60 Infinity-Corrected |
| Eyepiece Field Number | 20 mm (10×), 12 mm (15×) |
| Objective Mount | Inclined Quadruple Nosepiece |
| Condenser | E2 Abbe Condenser, NA 1.25 |
| Focusing | Coaxial coarse/fine focus, fine focus graduation: 2 µm, coarse travel per revolution: 37.7 mm, fine travel per revolution: 0.2 mm |
| Stage | Rectangular mechanical stage, 216 × 150 mm, 78 × 54 mm travel |
| Ergonomic Tilting Eyepiece Tube | 30° inclination, interpupillary adjustment 47–75 mm, eyepoint height adjustable up to +34 mm |
| Anti-Fungal Protection | Integrated anti-mold coating and desiccant strips, validated for continuous operation at 30°C / 80% RH for ≥36 months |
| Compliance | Designed to support ISO/IEC 17025-compliant documentation workflows |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ci-E |
| Optical System | CFI60 Infinity-Corrected |
| Illumination | High-Brightness White LED (Eco-Friendly) |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment (30 mm Travel, 9.33 mm/rev Coarse, 0.1 mm/rev Fine) |
| Eyepieces | CFI 10× (22 mm FOV), CFI 12.5× (16 mm FOV), CFI 15× (14.5 mm FOV), CFI UW 10× (25 mm FOV) |
| Nosepiece | Motorized 6-Position with Polarizer Slot |
| Stage | 78 × 54 mm X-Y Travel, Ergonomic Adjustable Handle |
| Condenser Options | Motorized CI-CE (NA 0.9 / 0.22), Abbe (NA 0.9), Achromatic (NA 0.8), Darkfield Oil (NA 1.2–1.43), Phase Contrast (NA 0.9), Apochromatic (NA 1.4), LWD Achromatic (NA 0.65) |
| Observation Modes | Brightfield, Epi-Fluorescence, Darkfield, Phase Contrast, Simple Polarization, Sensitive Color Polarization |
| Fluorescence Accessories | CI-FL (4-filter turret), D-FL (6-filter turret), ND4/ND8/ND16, Excitation Noise Suppression |
| Fluorescence Illuminators | C-LEDFI LED Epi-Illuminator, C-HGFI/HGFIE Fiber-Coupled 130 W Mercury Arc |
| Power Consumption | 6–38 W (Configuration-Dependent) |
| Weight | ~13.4–15.4 kg (Depending on Configuration) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | Eclipse Ci-L PLUS |
| Optical System | CFI60 Infinity-Corrected |
| Illumination | High-Efficiency LED (5.0 W) |
| Eyepiece Field of View | 22 mm (binocular), 25 mm (trinocular) |
| Eyepiece Tube Diameter | Φ30 mm |
| Focusing | Coaxial coarse/fine focus with 30 mm travel, 1 µm fine focus increment |
| Stage Travel | 78 × 54 mm (X–Y) |
| Stage Height Adjustment | Adjustable handle + optional shims |
| Ergonomic Tilting Head | 10°–30° inclination, 40 mm extension |
| Weight | 13.3 kg (binocular configuration) |
| Compliance | CE, ISO 13485 (design & manufacturing processes), RoHS-compliant components |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ci-L |
| Optical System | CFI60 Infinity-Corrected |
| Illumination | High-Brightness White LED (Eco-Friendly) |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment (30 mm Travel, 9.33 mm/rev Coarse, 0.1 mm/rev Fine) |
| Eyepieces | CFI 10× (22 mm FOV), CFI 12.5× (16 mm FOV), CFI 15× (14.5 mm FOV), CFI UW 10× (25 mm FOV) |
| Nosepiece | Motorized 6-Position with Polarizer Slot |
| Stage | 78 × 54 mm X-Y Travel, Ergonomic Adjustable Handle |
| Condenser Options | CI-CE Motorized (NA 0.9 / 0.22), C-AB Abbe (NA 0.9), C-PH Phase Contrast, C-DO Oil Darkfield (NA 1.2–1.43), C-DD Dry Darkfield (NA 0.8–0.95), C-AA Achromat-Apochromat (NA 1.4) |
| Observation Modes | Brightfield, Epi-Fluorescence, Darkfield, Phase Contrast, Simple Polarization, Sensitive Color Polarization |
| Fluorescence Accessories | CI-FL (4-filter cube capacity), D-FL (6-filter cube capacity), ND4/ND8/ND16, Excitation Noise Suppression |
| Epi-Illuminators | C-LEDFI LED, C-HGFI/C-HGFIE Fiber-Coupled Mercury (130 W) |
| Power Consumption | 6–38 W (Config-Dependent) |
| Weight | ~13.4–15.4 kg (Configuration-Dependent) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ci-S |
| Optical System | CFI60 Infinity-Corrected |
| Illumination | High-Brightness White LED (Eco-Friendly) |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment (30 mm Travel, 9.33 mm/rev Coarse, 0.1 mm/rev Fine) |
| Eyepieces | CFI 10× (22 mm FOV), CFI 12.5× (16 mm FOV), CFI 15× (14.5 mm FOV), CFI UW 10× (25 mm FOV) |
| Nosepiece | Motorized 6-Position with Polarizer Slot |
| Stage | 78 × 54 mm X-Y Travel, Ergonomic Adjustable Handle |
| Condenser Options | CI-CE Motorized Dual-NA (0.9 / 0.22), C-AB Abbe (0.9), C-AR Achromatic (0.8), C-DO Oil Darkfield (1.2–1.43), C-DD Dry Darkfield (0.8–0.95), C-PH Phase Contrast (0.9), C-AA Apochromatic (1.4), C-SA Sliding Achromatic (2–100×), C-SW Swing-out Achromatic (1–100×), C-SWA Swing-out Achromatic (2–100×), C-LAR LWD Achromatic (0.65) |
| Observation Modes | Brightfield, Epi-Fluorescence, Darkfield, Phase Contrast, Simple Polarization, Sensitive Color Polarization |
| Fluorescence Accessories | CI-FL (4-filter cube capacity), D-FL (6-filter cube capacity), ND4/ND8/ND16, Excitation Noise Suppression |
| Epi-Fluorescence Light Sources | C-LEDFI LED Illuminator, C-HGFI/C-HGFIE Fiber-Coupled 130 W Mercury Arc |
| Power Consumption | 6–38 W (Configuration-Dependent) |
| Weight | ~13.4–15.4 kg (Depending on Configuration) |
| Brand | NIKON |
|---|---|
| Origin | Japan |
| Model | E100 |
| Microscope Type | Upright Biological Microscope |
| Eyepiece Configuration | Binocular |
| Optical System | CFI Infinity-Corrected Optics |
| Illumination | High-Efficiency LED (60,000 hr lifetime) |
| Objective Series | CFI BE Plan Achromat |
| Condenser | Abbe Condenser, NA 1.25 |
| Focus Mechanism | Coaxial Coarse/Fine Adjustment (2 µm fine graduation) |
| Stage | Dual-layer Mechanical Stage (155 × 134 mm) |
| Eyepiece Inclination | 30° |
| Interpupillary Distance Range | 47–75 mm |
| Eye-point Adjustment Range | 34 mm |
| Optional Accessories | Phase Contrast Rings (10×, 40×, 100×), Darkfield Annuli (10×, 20×, 40×), Filter Holder (33 mm) |
| Brand | NIKON |
|---|---|
| Origin | Japan |
| Model | E100 Trinocular |
| Optical System | CFI Infinity-Corrected |
| Observation Head | E2-TF Trinocular, 30° Inclination, Interpupillary Distance 47–75 mm |
| Eyepieces | CFI E 10×/18 (standard), optional CFI E 15×/12 |
| Objective Turret | Quadruple Nosepiece |
| Objectives | CFI BE Plan Achromat 4×, 10×, 40×, 100× (oil), optional 20×, 60× |
| Condenser | Abbe Condenser, NA 1.25, 33 mm Filter Holder |
| Focusing | Coaxial Coarse/Fine Focus, Fine Focus Graduation 2 µm, Coarse Travel 37.7 mm/rev, Fine Travel 0.2 mm/rev, Total Travel 22 mm |
| Stage | Double-Layer Mechanical Stage, 155 × 134 mm |
| Illumination | High-Efficiency White LED (60,000 h lifetime), Constant CCT across intensity range, IR-free, low heat, low power consumption |
| Accessories | Phase Contrast Annuli (10×, 40×, 100×), Darkfield Rings (10×, 20×, 40×), Pointer, Mirror, Power Cord Clip, Protective Packaging (Aluminum Case) |
| Anti-Fungal Treatment | Applied to eyepieces, objectives, and observation tube |
| Brand | NIKON |
|---|---|
| Origin | Japan |
| Model | E200 Trinocular |
| Optical System | CFI60 Infinity-Corrected |
| Observation Head | Trinocular (E2-TF), 30° Inclination, Interpupillary Distance 47–75 mm |
| Eyepieces | CFI 10×/20 mm Field Number (FN) |
| Objective Lenses | CFI E Plan Achromat 4×, 10×, 40×, 100× (anti-fungal coated) |
| Nosepiece | Inclined 4-position Revolving Nosepiece |
| Condenser | E2 Abbe Condenser, NA 1.25 |
| Focusing Mechanism | Coaxial Coarse/Fine Focus, Fine Focus Graduation 2 µm, Coarse Travel 37.7 mm/rev, Fine Travel 0.2 mm/rev |
| Stage | Rectangular Mechanical Stage, 216 × 150 mm, Travel Range 78 × 54 mm |
| Illumination | LED Light Source (60,000 hr lifetime), Constant CCT Across Intensity Range, IR-Free, Low Heat & Power Consumption |
| Anti-Fungal Protection | Internal Anti-Mold Coating + Desiccant Mold-Prevention Strips (validated for 3 years at 30°C / 80% RH) |
| Ergonomics | Adjustable Tilting Eyepiece Tube (±30°), Height-Optimized Stage Controls, Low-Profile Knob Placement |
| Compatibility | CFI60 Objective Mount, Full Eclipse Series Accessory Ecosystem (Phase Contrast, Fluorescence, Polarization, Digital Imaging) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ji |
| Optical System | CFI Infinity Optics |
| Microscope Type | Inverted Fluorescence Microscope |
| Observation Modes | Brightfield & Epi-Fluorescence |
| Field Number | 25 |
| Camera | 7.8 MP Monochrome CMOS Sensor |
| Bit Depth | 12-bit / 8-bit |
| Max Frame Rate | 18 fps |
| Output Resolution | 2800 × 2800 pixels |
| Focus Drive | Motorized PFS (Perfect Focus System) |
| Focus Travel | ~10 mm |
| Max Focus Speed | 2.5 mm/sec |
| PFS Method | Infrared Projection-Based Focus Maintenance |
| Stage Travel (X/Y) | ±59 mm / ±39.5 mm |
| Max Stage Speed | ~25 mm/sec |
| Objective Turret | 6-position, Motorized |
| Filter Cube Capacity | 6 positions (wide-field compatible) |
| Filter Turret Drive | Motorized |
| Light Source | D-LEDI2 LED Fluorescence Illuminator |
| Illumination | Köhler LED Transmitted Light |
| Interface | USB 3.0 (SuperSpeed), USB-B connector |
| Input Voltage | 100–240 VAC ±10%, 50/60 Hz |
| Power Consumption | 320 W |
| Compliance | UL, CE, RoHS |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | Nikon ECLIPSE Ni-E (Objective-Focusing Type) |
| Optical System | CFI60 and CFI75 Infinity-Corrected Optics |
| Focusing Mechanism | Motorized Objective Nosepiece Translation (±13 mm vertical travel) |
| Linear Encoder Resolution | 0.025 µm |
| Illumination | High-CRI LED (50,000 hr lifetime) or 12V/100W Halogen |
| Eyepiece FOV | 22 mm or 25 mm |
| Motorized Components | NI-N7-E 7-Position Objective Turret, NI-S-E XY Stage (0.1 µm resolution), NI-TT2-E Motorized Quad-Port Tilting Trinocular Tube |
| Compliance | Designed for GLP/GMP-compliant imaging workflows with audit-trail-ready control architecture |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ni-E |
| Optical System | CFI60 and CFI75 Infinity-Corrected |
| Focusing Mechanism | Motorized Stage (±13 mm total travel, 0.025 µm encoder resolution) |
| Illumination | 12V/100W Halogen or High-CRI LED (50,000 hr lifetime) |
| Objective Turret Options | NI-N7-E (7-port motorized), NI-ND6-E (6-port DIC motorized), NI-N7-I (7-port smart) |
| Stage Options | NIE-CSRR2 (manual ceramic-coated, 78 × 54 mm), NI-S-E (motorized XY, 0.1 µm resolution) |
| Condenser Options | NI-CUD-E (motorized dry, NA 0.88), C-AB (Abbe, NA 0.90), C-PH (phase contrast turret), D-CUO (DIC oil, NA 1.40) |
| Eyepieces | CFI 10X (22 mm FOV), CFI 12.5X (16 mm), CFI 15X (14.5 mm), CFI UW10X (25 mm) |
| Tube Options | C-TE2 (ergonomic binocular), NI-TT2-E (motorized quad-port, 15–35° tilt) |
| Power Consumption | ≤211 W (halogen + full motorization), ≤96 W (LED + full motorization) |
| Weight | 18–32 kg (configuration-dependent) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ni-L |
| Optical System | CFI60 and CFI75 Infinity-Corrected Optics |
| Focusing Mechanism | Motorized Stage and/or Motorized Nosepiece (Z-travel: up to 13 mm / down to 2 mm) |
| Z-Axis Resolution | 0.025 µm (linear encoder) |
| Illumination | 12V/100W Halogen or High-CRI LED (50,000 h lifetime) |
| Optional Components | NI-N7-E 7-Position Motorized Nosepiece, NI-S-E Motorized XY Stage (0.1 µm resolution), NI-TT2-E Motorized Tilting Quad-Port Tube, NI-RPZ-E Motorized Zoom Port (0.6×–2.0×), NI-CUD-E Motorized Universal Condenser (NA 0.88) |
| Compliance | Designed for GLP/GMP-compliant laboratories |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ni-U |
| Optical System | CFI60 Infinity-Corrected |
| Focusing Mechanism | Motorized Stage & Nosepiece |
| Illumination | 12V 100W Halogen / High-CRI LED (50,000 hr lifetime) |
| Objective Turret Options | NI-N7-E (7-port motorized), NI-ND6-E (6-port DIC motorized), NI-N7-I (7-port smart) |
| Stage Travel | 78 × 54 mm (manual), 0.1 µm resolution (NI-S-E motorized) |
| Encoded Z-Focus | 0.025 µm resolution |
| Condenser | NI-CUD-E (NA 0.88, motorized universal dry) |
| Eyepiece FOV | 22 mm or 25 mm |
| Port Options | C-mount, F-mount, variable zoom (0.6×–2.0×), DSC ports with magnification adapters |
| Power Consumption | ≤211 W (max halogen + full motorization) |
| Weight | 18–32 kg (configuration-dependent) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Si |
| Optical System | CFI60 Infinity-Corrected Optics |
| Illumination | High-Brightness White LED (Eco-Friendly) with Built-in Köhler Illumination via Fly’s Eye Lens |
| Filter Capacity | Two 45 mm Filters (Optional) |
| Light Intensity Management (LIM) | Yes |
| Focus Mechanism | Coaxial Coarse/Fine Focus (Dual-Side Controls) |
| Focus Travel | +2 mm (Above Top Position) / −13 mm (Below Top Position) |
| Coarse Focus | 37.7 mm per Revolution |
| Fine Focus | 0.2 mm per Revolution |
| Minimum Graduation | 2 µm |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ti2-A |
| Optical System | CFI60 Infinity-Corrected |
| Intermediate Magnification | 1.0× / 1.5× (field-replaceable to 2.0×) |
| Focus Mechanism | Motorized coarse/fine focus with 10 mm travel, minimum step size: 0.01 µm (encoder-controlled) |
| Condenser | Motorized turret (TI2-C-TC-E) supporting 7 positions (ø37 mm × 4, ø39 mm × 3), including LWD, ELWD, CLWD, HNA dry/oil, and NAMC objectives |
| Stage | Motorized XY stage (TI2-S-SE-E): ±57 mm X, ±36.5 mm Y, max speed 25 mm/s |
| Objective Turret | 6-position motorized nosepiece with Perfect Focus System (PFS) and DIC compatibility |
| Epi-Fluorescence Filter Turret | 6-position motorized filter cube turret (TI2-F-FLT-E) with integrated shutter |
| Illumination | LED-based transmitted illumination (TI2-D-LHLED), optional 100 W halogen or pre-centered D-LH/LC lamp housing |
| Software Integration | Compatible with NIS-Elements AR/VR/CV platforms |
| Environmental Rating | Indoor use only |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ti2-E |
| Type | Inverted Research Microscope with Motorized Precision Optomechanics |
| Optical System | CFI60 Infinity-Corrected, Field Number 22 (Eyepiece), Field Number 16 (Camera Port) |
| Intermediate Magnification | 1.0× / 1.5× (field-upgradable to 2.0×) |
| Focus Drive | Motorized coarse/fine focusing, 10 mm travel, minimum step size 0.01 µm (encoder-controlled) |
| Condenser Turret | Motorized 7-position (TI2-C-TC-E), supporting LWD, ELWD, CLWD, HNA dry/oil, and NAMC objectives |
| Objective Nosepiece | 5-position motorized with Perfect Focus System (PFS) and correction collar control |
| Epi-Fluorescence Filter Turret | 6-position motorized (TI2-F-FLT-E) with integrated shutter |
| Stage | Motorized XY stage (±57 mm X, ±36.5 mm Y), max speed 25 mm/s, magnetic sample holder |
| Illumination | LED-based transmitted illumination (TI2-D-LHLED), optional 100 W halogen or pre-centered D-LH/LC lamp |
| Software Compatibility | NIS-Elements AR/C/VR, supports FDA 21 CFR Part 11 compliance modules, GLP/GMP audit trail logging |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ti2-U |
| Optical System | CFI60 Infinity-Corrected |
| Intermediate Magnification | 1.0× / 1.5× (field-replaceable to 2.0×) |
| Focus Mechanism | Motorized coarse/fine focus with 10 mm travel, minimum step size: 0.01 µm (encoder-controlled) |
| Condenser | Motorized turret (7-position, supports LWD/ELWD/CLWD/HNA/NAMC objectives) |
| Stage | Motorized XY stage (±57 mm X, ±36.5 mm Y, max speed 25 mm/s) |
| Nosepiece | 6-position motorized objective revolver with Perfect Focus System (PFS) and DIC compatibility |
| Epi-Fluorescence Turret | 6-position motorized filter turret with integrated shutter |
| Illumination | LED-based transmitted illumination (TI2-D-LHLED) and fiber-coupled epi-fluorescence modules |
| Environmental Rating | 0–40 °C, ≤60% RH (non-condensing), indoor use only |