HOGON
Filter
Showing 31–60 of 202 results
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | AKF-CH6 |
| Price | USD 9,500 (approx.) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Coulometric Karl Fischer Moisture Analyzer |
| Detection Principle | Coulometric Titration (Karl Fischer) |
| Sensitivity | 0.1 µg H₂O |
| Temperature Control Range | 30–200 °C |
| Blank Value Stability | ≤553 µg |
| Repeatability (RSD) | <2% |
| Compliance | ASTM D6304, ISO 760, GB/T 7139 |
| Sample Form | Solid films, granules, powders, resins |
| Application Scope | PVB, adhesives, coatings, thermoplastics, epoxy resins |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | AKF-CH6 |
| Price | USD 9,500 (FOB Shanghai) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Integrated Coulometric Karl Fischer Moisture Analyzer with Heated Oven |
| Measurement Principle | Coulometric Karl Fischer Titration (ASTM E203, ISO 15512, USP <921>) |
| Detection Range | 1 µg – 200 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±2 µg (for <100 µg), ±0.2% (for >100 µg) |
| Sample Heating Temperature | 50–300 °C (adjustable in 1 °C increments) |
| Carrier Gas Flow Rate | 20–200 mL/min (N₂, dry and oil-free) |
| Electrode System | Dual-platinum indicator electrodes + diaphragm-separated generator electrode |
| Cell Design | Fully enclosed, moisture-tight titration cell with PTFE-coated seals |
| Compliance | GLP-compliant data logging, 21 CFR Part 11 ready (audit trail, electronic signatures, user access control) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Coulometric Moisture Analyzer |
| Model | AKF-CH6 |
| Price | USD 9,500 (approx.) |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Detection Method | Polarization Current Detection |
| Electrode Configuration | Dual Platinum Microelectrodes |
| Titration Cell | Sealed, Dry-Gas Purged Coulometric Cell |
| Typical Analysis Time | ≤7 min per sample |
| Sample Mass Range | 0.25–0.28 g |
| Water Quantification Range | 1–500 µg H₂O |
| Resolution | 0.1 µg H₂O |
| Compliance | ASTM E203, ISO 760, USP <921>, EP 2.5.12, GLP-ready architecture |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Type | CH6 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Detection Range | 1 µg – 100 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±2 µg (for <100 µg), ±0.2% (for >100 µg) |
| Electrode System | Dual-platinum indicator electrode + Membrane-separated generator electrode |
| Sample Heating | Adjustable up to 250 °C (default 120 °C for lactide) |
| Carrier Gas Flow | 5–100 mL/min (preset 20 mL/min for lactide) |
| Stirring Speed | 1–10 level (preset level 5) |
| Blank Value Compensation | Yes (e.g., 55 µg typical background) |
| Compliance | ASTM E203, ISO 760, USP <921>, EP 2.5.12, GLP-compliant data audit trail capability |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AKF-CH6 Coulometric |
| Price | USD 9,500 (FOB Shanghai) |
| Category | Coulometric Moisture Analyzer / Electrochemical Instrument / Karl Fischer Titrator |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | AKF-CH6 |
| Price | USD 9,500 (approx.) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-CH6 |
| Detection Principle | Coulometric Karl Fischer Titration |
| Carrier Gas Flow Rate | 25 mL/min |
| Heating Temperature Range | Up to 150 °C |
| Electrolysis Mode | Auto-ranging |
| Stirring Speed | Adjustable (5-level) |
| Blank Value | ≤40 µg H₂O |
| Electrode Configuration | Dual Platinum Indicator Electrodes + Membrane-separated Generator Electrode |
| Titration Cell | Sealed, Safety-optimized Coulometric Cell |
| Compliance | ASTM E203, ISO 8533, USP <921>, EP 2.5.12 |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | AKF-CH6 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Heating Temperature Range | Up to 140 °C (adjustable) |
| Detection Limit | < 1 µg H₂O |
| Typical Analysis Time | ~7 min per sample |
| Compliance | GLP-compliant data handling, ASTM E203, ISO 8533, USP <921>, EP 2.5.12 |
| Brand | Hogon |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | AKF-CH6 |
| Price | USD 9,500 (approx. ¥68,000) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | AKF-CH6 |
| Detection Principle | Coulometric Karl Fischer Titration |
| Electrode Configuration | Dual Platinum Indicator Electrodes + Membrane Separated Generator Electrode |
| Heating Temperature | 150 °C (programmable, ±0.5 °C stability) |
| Measurement Range | 1 µg – 200 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±0.3% of reading (for samples ≥10 µg H₂O) |
| Repeatability | RSD < 0.5% (n=6, typical carbon-coated Al foil) |
| Sample Throughput | ≤10 min per test (including heating, purging, and titration) |
| Environmental Protection | Sealed titration cell with desiccant-protected reagent reservoir |
| Compliance Support | ASTM E203, ISO 8533, USP <921>, GLP-compliant audit trail (optional software module) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Type | Coulometric Karl Fischer Moisture Analyzer |
| Detection Principle | Coulometric Karl Fischer Titration |
| Measurement Range | 1 µg – 200 mg H₂O |
| Detection Limit | <0.1 µg H₂O |
| Resolution | 0.1 µg |
| Temperature Control Range | Ambient to 300 °C (adjustable in 0.1 °C increments) |
| Heating Accuracy | ±0.5 °C |
| Gas Compatibility | High-purity N₂ or Ar (flow rate: 0–500 mL/min, controllable) |
| Electrode System | Dual-platinum generator and detector electrodes with polarization current monitoring |
| Data Output | H₂O mass (µg), concentration (ppm or %), and statistical summary (n ≥ 3) |
| Compliance | ASTM E203, ISO 760, USP <921>, EP 2.5.12, GLP-compliant audit trail (optional firmware module) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer with Integrated Heating Oven |
| Water Content Range | 3 µg – 199 mg H₂O (0.01 µg resolution) |
| Measurement Accuracy | ≥99.7% at 1000 µg H₂O |
| Repeatability | ≤0.3% RSD |
| Linearity Correlation Coefficient | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Titration Control Precision | 0.01 µg H₂O |
| Electrode Type | Electrolytic Electrode |
| Power Supply | 300 W, 220 V / 50 Hz |
| Data Storage | Internal non-volatile memory with timestamped method and result logging |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Combined Coulometric Karl Fischer Moisture Analyzer with Integrated Sample Evaporator |
| Water Content Range | 3 µg – 199 mg H₂O (0.01 µg resolution) |
| Measurement Accuracy | ≥99.7% at 1000 µg H₂O |
| Repeatability | RSD ≤0.3% |
| Linearity Correlation Coefficient | ≥0.999 |
| Polarization Voltage Adjustment Range | ±10% |
| Titration Control Precision | 0.01 µg H₂O |
| Electrode Type | Dual-platinum electrolysis electrode |
| Power Supply | 110–240 V AC, 50–62 Hz |
| Data Storage | Internal non-volatile memory with timestamped audit trail |
| Sample Introduction | Heated headspace evaporation with dry carrier gas (N₂ or air), dual-mode sampling (puncture-seal + screw-cap vial handling) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-CH6 |
| Titration Mode | Fully Automatic Coulometric Titration |
| Water Content Range | 3 µg – 199 mg |
| Resolution | 0.01 µg |
| Accuracy | ≤0.3% |
| Minimum Electrolytic Delivery | Electrolytic Mode Only |
| Repeatability | ≥99.7% |
| Linearity (R²) | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Titration Electrode | Dual Platinum Electrolysis Electrode |
| Titration Control Precision | 0.1 µg |
| Power Requirement | 300 W |
| Data Interface | RS232 / USB |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer with Integrated Sample Evaporator |
| Measurement Resolution | 0.01 µg H₂O |
| Water Content Range | 3 µg – 199 mg H₂O |
| Accuracy | ≥99.7% (at 1000 µg H₂O) |
| Minimum Sample Injection | 3 µg H₂O |
| Repeatability | ≤0.3% RSD |
| Linearity (r²) | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Titration Electrode | Dual-platinum electrolysis electrode |
| Titration Current Control Precision | 0.1 mA |
| Power Supply | 300 W, 220 V / 50 Hz |
| Data Storage | Internal non-volatile memory with timestamped method and result logging |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.01 µg H₂O |
| Water Content Range | 3 µg – 199 mg H₂O |
| Accuracy | ≥99.7% (at 1000 µg H₂O) |
| Minimum Sample Injection | 3 µg H₂O |
| Repeatability | ≤0.3% RSD |
| Linearity (r²) | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Electrode Type | Electrolytic Electrode |
| Titration Control Precision | 0.01 µg H₂O |
| Power Supply | 300 W, 220 V / 50 Hz |
| Data Storage | Supported |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer with Integrated Sample Evaporator |
| Water Content Range | 3 µg – 199 mg H₂O (0.01 µg resolution) |
| Measurement Accuracy | ≥99.7% at 1000 µg H₂O |
| Repeatability | ≤0.3% RSD |
| Linearity Correlation Coefficient | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Electrolysis Electrode Configuration | Dual-electrode coulometric cell |
| Titration Control Precision | 0.01 µg H₂O |
| Power Supply | 220 V / 50 Hz, 300 W |
| Data Storage | Internal non-volatile memory with timestamped method and result logging |
| Sample Introduction | Heated headspace evaporation with dry carrier gas (N₂ or air), dual-mode sampling (puncture-seal + screw-cap vial) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer with Integrated Heating Oven |
| Water Content Range | 3 µg – 199 mg H₂O (0.01 µg resolution) |
| Measurement Resolution | 0.01 µg H₂O |
| Accuracy | ≥99.7% at 1000 µg H₂O |
| Minimum Sample Injection | 3 µg H₂O |
| Titration Control Precision | 0.01 µg H₂O |
| Titration Mode | Fully Automated Coulometric Titration |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Moisture Range | 1 ppm to 100% (w/w) |
| Resolution | 0.01 µg H₂O |
| Accuracy | ≥99.7% at 1000 µg H₂O |
| Minimum Sample Injection | 3 µg |
| Repeatability | ≤0.3% RSD |
| Linearity (r²) | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Electrode Configuration | Dual Platinum Electrolysis Electrodes |
| Titration Control Precision | 0.01 µg H₂O |
| Power Supply | 220 V / 50 Hz, 300 W |
| Data Storage | Internal non-volatile memory with timestamped audit trail |
| Brand | HOGON |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Tester |
| Model | AKF-CH7 |
| Detection Limit | 0.1 µg (equivalent to 0.1 ppm in 100 mg sample) |
| Repeatability | RSD < 1.5% |
| Analysis Time | ≤10 min per sample |
| Sample Heating Temperature | Up to 180 °C |
| Carrier Gas Flow Rate | Adjustable up to 20 mL/min |
| Compliance | ISO 760, ASTM E203, USP <921>, EP 2.5.12 |
| Software Features | Touchscreen GUI, Pre-programmed CNT Mode, Audit Trail, Data Export (CSV/PDF), Cloud Sync Capability |
| Regulatory Support | 21 CFR Part 11-compliant user access control and electronic signature options available |
| Brand | HOGON |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AKF-CH7 Coulometric Karl Fischer Moisture Titrator |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Method | Coulometric Titration (Karl Fischer) |
| Detection Principle | Electrochemical generation of iodine via constant-current electrolysis |
| Detection Range | 1 µg – 200 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±2 µg (for <100 µg), ±0.2% (for >100 µg) |
| Sample Introduction | Heated oven coupling with carrier gas (N₂ or dry air) |
| Temperature Control | 50–300 °C (adjustable in 1 °C increments) |
| Electrolytic Cell | Dual-platinum electrode, sealed glass cell with molecular sieve drying tube |
| Compliance | ASTM E203, ISO 760, ISO 15512, USP <921>, EP 2.5.12, GLP-compliant data integrity features |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Method | Fully Automatic Coulometric Titration |
| Moisture Range | 1 ppm to 100% w/w |
| Measurement Resolution | ±0.1 µA |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Repeatability | ≥99.7% (n=6) |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage | Not applicable (coulometric mode) |
| Electrolysis Electrode | Integrated dual-platinum electrode system |
| Current Control Precision | 0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage | Internal non-volatile memory with timestamped records |
| Brand | HOGON |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-CH7 Multi-Station |
| Measurement Principle | Coulometric Karl Fischer Titration (Polarographic Current Detection) |
| Sample Heating Temperature | Up to 230 °C |
| Typical Analysis Time | ≤10 min per sample |
| Detection Limit | < 0.1 µg H₂O |
| Resolution | 0.1 µg |
| Compliance Basis | ASTM E203, ISO 8533, USP <921>, GB/T 11133, GB/T 6283 |
| Software Features | GLP-compliant audit trail, user permission levels, electronic signature support (21 CFR Part 11 ready) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Range | 1 ppm – 100% water content |
| Resolution | ±0.1 µA |
| Accuracy | ≤0.3% |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Titration Control Precision | 0.1 mA |
| Polarization Voltage | Not applicable (coulometric mode) |
| Electrolysis Electrode | Integrated dual-platinum electrode system |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage | Internal non-volatile memory with timestamped records |
| Sample Positioning | 8-position automated rotary sample carousel |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.01 µg |
| Water Mass Range | 3 µg – 199 mg |
| Measurement Precision | ±1 mV |
| Minimum Dispensing Increment | 1/2000 of Burette Volume |
| Repeatability | ≥99% |
| Linearity (R²) | 0.995 |
| Electrode Type | Electrolytic Electrode |
| Current Control Accuracy | ±1 mA |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage | Internal Non-Volatile Memory |
| Compliance | SH/T 1770–2010 |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric & Volumetric Karl Fischer Moisture Titrator |
| Measurement Resolution | 0.1 µg (H₂O mass) |
| Water Content Range | 3 µg – 199 mg (0.01 µg detection limit for water mass) |
| Accuracy | ≤0.3% |
| Minimum Dispense | 3 µg |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Titration Component | Electrolytic Electrode |
| Titration Control Precision | 0.1 µg |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 10 ppm – 100% w/w |
| Resolution | 0.1 mV |
| Accuracy | ±0.1 mV |
| Minimum Dispensing Volume | 0.5 µL |
| Repeatability | ±0.3% RSD |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage Range | 0–120 mV |
| Burette Capacity | 10 mL / 20 mL |
| Titration Precision | ±0.5 µL |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |