HuaShengPuXin (HSPX)
Filter
Showing 1–30 of 32 results
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 350 °C |
| Secondary Desorption Temp Range | Ambient to 350 °C |
| Valve Inlet Temp Range | Ambient to 220 °C |
| Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp Range | −30 °C to 50 °C |
| Temperature Control Accuracy | ±1 °C |
| Temperature Resolution | 1 °C |
| Sample Capacity | 30 positions |
| Desorption Recovery Rate | >98% (compound-dependent) |
| Cold Trap Cooling Rate | ≥2500 °C/min |
| Purge Flow Rate | 0–500 mL/min (continuously adjustable) |
| Dimensions | 520 × 520 × 500 mm (W × H × D) |
| Weight | ~45 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Dual-Channel Low-Temperature Cryo-Trap, 40-Position |
| Automation Level | Fully Automated |
| Desorption Temperature Range | 150–380 °C |
| Valve Injection Zone Temperature Range | Ambient to 240 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cryo-Trap Temperature Range | −30 to 50 °C (1 °C increments) |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >95% |
| Sample Capacity | 40 adsorption tubes |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Secondary Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Zone Temperature Range | Ambient to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 240 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cold Trap Temperature Range | −30 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >95% |
| Sample Capacity | 20 adsorption tubes (dual-channel configuration) |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-3600A |
| Temperature Control Range | Ambient to 400 °C |
| Heating Rate | 0.1–40 °C/min |
| Cooling Rate | 400 °C to 50 °C in ~5 min |
| Carrier Gas Flow Range | 0–60 mL/min |
| Carrier Gas Pressure Range | 0–0.6 MPa |
| Injector Max Temp | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Sample Positions | 20 |
| Cold Trap Temp Range | −30 °C to +50 °C |
| Temp Accuracy | <±0.1 °C |
| Temp Gradient Uniformity | <±0.1 °C |
| Transfer Line & Valve Zone Temp Control | Ambient to 220 °C |
| Desorption Ramp Rate | >2000 °C/min |
| Purge Flow | 0–400 mL/min |
| Dimensions | 450 × 360 × 510 mm |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Temperature Control Accuracy | ±0.1 °C |
| Analyte Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | ≥10 positions |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Primary Desorption Temp Range | Ambient to 350 °C |
| Valve Inlet Temp Range | Ambient to 220 °C |
| Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp Range | −35 °C to 50 °C |
| Temperature Control Accuracy | ±1 °C |
| Desorption Recovery Rate | >98% |
| Sample Position Capacity | 1 |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | 50–400 °C |
| Valve Injection Zone Temp Range | Ambient to 200 °C |
| Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp Range | −35 to 50 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Desorption Recovery Efficiency | ≥98% |
| Sample Capacity | 50 positions |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Single-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Sample Zone Temperature Range | Ambient to 400 °C |
| Valve Injection System Temperature Range | Ambient to 180 °C |
| Transfer Line Temperature Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Desorption Recovery Rate | ≥95% |
| Sample Position Capacity | 1 |
| Dimensions | 170 × 390 × 400 mm |
| Weight | ~10 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-6210T Dedicated for Formaldehyde Dimethyl Acetal |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Medical Device Sterilization Validation & Clinical Diagnostics |
| Temperature Control Range | Ambient +4 °C to 450 °C (1 °C increment, ±0.01 °C accuracy) |
| Oven Ramp Rate | 0.1–39 °C/min (standard), 0.1–80 °C/min (high-speed option) |
| Cooling Rate | 450 °C → 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Programmable Temperature Ramping | Up to 16 steps |
| External Event Inputs | 6 channels |
| Auxiliary Control Outputs | 2 channels |
| Injector Compatibility | Packed column, capillary column, 6-port gas valve, automated thermal desorption, purge-and-trap, and headspace sampling (HS-20A, HS-10A, or HS-12A optional) |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petroleum Refining & Fuel Quality Control |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC6210 |
| Price Range | USD 4,200 – 7,000 |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 400 °C → 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detection Limits (as per GB/T 17623) | H₂ ≤ 2 ppm, CO ≤ 5 ppm, CH₄ ≤ 0.1 ppm, CO₂ ≤ 5 ppm, C₂H₂ ≤ 0.1 ppm, C₂H₆ ≤ 0.1 ppm, C₂H₄ ≤ 0.1 ppm |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Capacity | 12 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Oven Temperature Range | Ambient to 220 °C |
| Valve & Loop Temperature Range | Ambient to 180 °C |
| Sample Transfer Line Temperature Range | Ambient to 200 °C |
| Quantitative Loop Volume | 1–2 mL (adjustable) |
| Temperature Control Accuracy | < ±0.5 °C |
| Temperature Uniformity (Gradient) | < ±0.5 °C |
| Dimensions (W×D×H) | 400 × 200 × 380 mm |
| Weight | 15.5 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Capacity | 150-position or 100-position vial carousel |
| Compliance | ASTM D6866, ISO 17025-aligned operation, GLP/GMP-ready data handling |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 20 positions |
| Vial Sizes Supported | 10 mL and 20 mL standard crimp-top headspace vials |
| Valve & Loop Temperature Range | Ambient to 200 °C |
| Quantitative Loop Volume | 1 mL |
| Temperature Control Accuracy | < ±0.1 °C |
| Sample Zone Temperature Range | Ambient to 260 °C |
| Transfer Line Temperature Range | Ambient to 200 °C |
| Power Supply | 220–240 V AC, 50–60 Hz |
| Operating Environment | 10–35 °C, 10–90% RH (non-condensing) |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HS-30A |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 30 positions |
| Vial Size Options | 10 mL or 20 mL standard headspace vials |
| Oven Temperature Range | Ambient to 240 °C (1 °C increment, ±0.1 °C accuracy, ~400 W heating power) |
| Valve & Transfer Line Temperature Range | Ambient to 240 °C (1 °C increment, ±0.1 °C accuracy |
| valve | ~100 W, transfer line: ~200 W) |
| Dimensions (W×D×H) | 460 × 450 × 520 mm |
| Weight | ~38 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Heating Range | 20°C to 200°C |
| Valve & Transfer Line Temperature Control Range | 20°C to 240°C |
| Sample Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.1°C |
| Vial Capacity | 40 positions |
| Vial Format | 20 mL standard headspace vials |
| Dimensions (W×D×H) | 530 × 680 × 655 mm |
| Weight | ~50 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Baijiu (Chinese Liquor) Analysis |
| Temperature Control Range | 20 °C to 450 °C |
| Temperature Ramp Rate | 0.1–80 °C/min |
| Cooling Rate | Up to 39.9 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Temperature Accuracy | ±0.01 °C |
| Minimum Temperature Increment | 1 °C |
| Programmable Temperature Program | Multi-step (≥8 stages) |
| External Event Inputs | 6 channels |
| Auxiliary Outputs | 2 channels |
| Injector Options | Packed column, capillary column, 6-port gas valve, automatic thermal desorption, purge-and-trap, and headspace sampling |
| Detector Capacity | Up to 3 detectors simultaneously |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | Baijiu-Specific |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Clinical Toxicology & Forensic Medical Testing |
| Temperature Control Range | Ambient + 5°C to 400°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Cool-down Time | ~6 min (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Temperature Accuracy | ±0.01°C |
| Max Programmed Ramp Stages | 16 |
| External Event Inputs | 6 channels |
| Auxiliary Outputs | 2 channels |
| Detector Capacity | Up to 3 simultaneous detectors (FID, TCD, ECD, FPD, NPD configurable) |
| Injector Options | Packed column, capillary column, 6-port gas valve, automated headspace, purge-and-trap, thermal desorption |
| Software | Dual-language (English/Chinese) GC workstation with audit trail, method validation support, and CFR Part 11–compliant data integrity features |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry Dedicated |
| Column Oven Temperature Range | Ambient + 5°C to 400°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Rate | 400°C to 50°C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HuaShengPuXin/HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | LPG-Dedicated |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Rate | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | GC-BA1000 |
| Price Range | USD 4,200–7,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Beverage Quality Control & Regulatory Compliance |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | From 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gaseous Oxygen & Liquid Oxygen Analysis |
| Temperature Control Range | 4 °C above ambient to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min (standard) |
| Cooling Rate | ~6 min from 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal (Mine Safety & Gas Monitoring) |
| Oven Temperature Range | Ambient +12 °C to 400 °C |
| Oven Ramp Rate | 0.1–39 °C/min (Standard) |
| Oven Cooling Rate | ~6 min from 450 °C to 50 °C |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detectors | TCD (MDL ≤9×10⁻⁶ mg/mL in H₂, n-C₁₆), FID (MDL ≤8×10⁻¹² g/s, n-C₁₆), ECD (MDL ≤0.1 pg, γ-BHC), FPD ([P] ≤1×10⁻¹² g/s, TBP |
| Column Configuration | Packed-column system with methanizer and automated 6-port valve for simultaneous O₂/N₂/CH₄/CO/CO₂ analysis |
| Detection Ranges | O₂ (20.9±5%), N₂ (78±10%), CH₄ (0.5 ppm–10%), CO (0.5 ppm–0.3%), CO₂ (1 ppm–0.5%), C₂H₆/C₂H₄/C₂H₂ (1 ppm–0.3%) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 1650 W |
| Net Weight | ~50 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China-made) |
| Model | Formaldehyde Dimethyl-Specific Gas Chromatograph |
| Price Range | USD 4,200 – 7,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Solvent Purity Analysis & Quality Control |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | From 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Oven Temperature Range | Ambient +5°C to 400°C |
| Temperature Ramp Rate | 0.1–40°C/min |
| Cooling Rate | 400°C → 50°C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Thermal Conductivity Detector (TCD) |
| TCD Sensitivity | ≥3000 mV·mL/mg (benzene) |
| TCD Baseline Drift | ≤3% of full scale per hour |
| Column | 3 mm ID × 6 m stainless steel packed column |
| Injection Mode | 6-port gas sampling valve |
| Display & Control | Microprocessor-controlled with backlit LCD and Chinese-language keypad |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | LC3000 |
| Price Range | USD 7,000 – 14,000 (FOB China) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Pump Type | Dual-Piston Reciprocating High-Pressure Solvent Delivery System (P3000 Series) |
| Detector Type | UV/VIS Absorbance Detector (UV3000) |
| Display | 320 × 240 dot-matrix LCD with adjustable blue backlight |
| Control Modes | Standalone front-panel operation & RS232 serial interface |
| Power Supply | 220 V ±10%, 50 Hz, 400 W (pump) |
| Dimensions (D×H×W) | 398 × 149 × 267 mm |
| Weight | 14 kg |
| GLP Data Logging | Lamp operating time, lamp ignition count, lamp replacement history, and instrument serial number |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | PT-3600A |
| Instrument Type | Water-and-Soil Integrated Purge and Trap System |
| Sample Tray Capacity | ≥30 positions |
| Trap Tube Temperature Range | Ambient to 350 °C |
| Sample Heating Temperature Range | Ambient to 90 °C |
| Water Trap Temperature Range | Ambient to 200 °C |
| Valve & Transfer Line Temperature Range | Ambient to 250 °C |
| Desorption Ramp Rate | >2000 °C/min |
| Temperature Control Accuracy | < ±0.5 °C |
| Temperature Uniformity Gradient | < ±1 °C |
| Vial Format | 40 mL |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | PT-3900A |
| Sample Tray Capacity | 84 positions |
| Temperature Control Accuracy | ±0.1°C |
| Trap Desorption Temperature Range | 100–350°C |
| Sample Heating Temperature (Purge Vessel) | up to 250°C |
| Sample Vial Cooling Temperature Range | 0–40°C |
| Water Removal Trap Temp Range | Ambient–200°C |
| Valve & Transfer Line Temp Range | Ambient–250°C |
| Trap Cryo-Focusing Temp Range | 0–40°C |
| Sample Oven Temp Range | Ambient–90°C |
| Hot Water Bath Temp Range | Ambient–90°C |
| Purge Tube Temp Range | Ambient–90°C |
| Desorption Ramp Rate | >2000°C/min |