ISOTECH
Filter
Showing 1–30 of 52 results
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 525Isis |
| Temperature Range | −100 °C to +40 °C |
| Cooling Time (to −100 °C from ambient) | 90 min |
| Stability at 0 °C | ±0.03 °C (30 min) |
| Stability at 90 °C | ±0.02 °C (30 min) |
| Radial Uniformity | 0.01 °C |
| Axial Gradient | 0.1 °C at 0 °C, 0.2 °C at −90 °C |
| Calibration Well Dimensions | Ø35 mm × 160 mm depth |
| Standard Insert | Six-hole sleeve set (9.5 mm, 8.0 mm, 6.4 mm, 6.4 mm, 4.5 mm, 4.5 mm) |
| Power Input | 200 W, 100–240 VAC, 50/60 Hz |
| Dimensions (H×W×D) | 215 × 420 × 640 mm |
| Weight | 22.7 kg |
| Brand | ISOTECH |
|---|---|
| Origin | USA |
| Model | Bridge Switching Unit |
| Channel Capacity | 3 standard (expandable to 90 channels) |
| Accuracy | <0.07 ppm full-scale, <0.017 ppm ratio accuracy (ratio range: 0–0.25 & 0.95–1.05) |
| Resolution | 0.001 ppm / 0.001 mK |
| Internal Standards | 25 Ω, 100 Ω, 400 Ω |
| Standard Stability | TCR < 0.05 ppm/°C |
| Excitation Current | 0.1–1 mA (±0.4% of reading ±0.7 µA |
| Resistance Range | 0–100 kΩ |
| Measurement Speed | <1 s (resistance), <2 s (temperature) |
| Input Compatibility | PRTs, thermistors, thermocouples |
| Display | 6.4″ VGA (640×480) color TFT LCD with capacitive touch |
| Interface | GPIB, RS-232, USB, Ethernet |
| Operating System | Embedded Windows CE |
| Switching Technology | Solid-state semiconductor switching |
| Connector Type | “Cable Pod” modular interface (accepts 4 mm banana plugs, flat-blade terminals, and bare wire) |
| Contact Material | Gold-plated tellurium-copper |
| ADC Architecture | Low-noise sigma-delta converter with low-noise preamplifier |
| Environmental Spec | 15–30 °C / 50–85 %RH (specification conditions) |
| Power | 88–264 VAC, 47–63 Hz, ≤20 W, ≤1.5 A RMS |
| Brand | ISOTECH |
|---|---|
| Origin | USA |
| Model | E4520 & V4951 & C4953 |
| Temperature Range | −45 °C to 250 °C |
| Stability | ±0.01 °C (E4520/V4951), ±0.02 °C (C4953) |
| Temperature Resolution | 0.001 °C (E4520/V4951), 0.01 °C (C4953) |
| Heating Time | 15 min (−30 °C → 140 °C |
| Cooling Time | 15 min (140 °C → 0 °C), 25 min (250 °C → 30 °C) |
| Dimensions (D×W×H) | 312 mm × 212 mm × 384 mm |
| Calibration Well | Ø35 mm × 160 mm depth |
| Horizontal Uniformity (Dry-Block Mode) | <0.008 °C (E4520/V4951), <0.02 °C @ 250 °C (C4953) |
| Vertical Uniformity (Dry-Block Mode, 40 mm below top) | <0.040 °C (E4520/V4951), <0.25 °C (C4953) |
| Input Compatibility | Thermocouples (E/J/K/N/R/S/T), RTDs (Pt100/Pt1000), CJC Accuracy: ±0.35 °C |
| Interface | Ethernet + USB |
| Power | 220 VAC, 50/60 Hz, 150–300 W |
| Weight | 8–14 kg |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Product Type | Portable Temperature Verification and Calibration System |
| Core Components | TTI-10 Dual-Channel Precision Thermometer & Fast Cal Series Dry-Block Calibrator |
| Measurement Accuracy | ±10 mK (±0.01 °C) |
| Resolution | 0.001 °C |
| Data Logging Capacity | Up to 4,000 points (min/max/avg) |
| Sampling Interval | 1 s to 30 min |
| Interface | USB 2.0 |
| Software Compatibility | ISOTECH Cal Notepad v3.x |
| Compliance | Designed for traceable calibration per ISO/IEC 17025 requirements |
| Portability | Handheld thermometer + lightweight dry-well (<4.5 kg typical) |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | FC Series |
| Instrument Type | Dry-Block Temperature Calibrator |
| Temperature Ranges | −35°C to 140°C |
| Stability | ±0.02°C (FC140/FC350), ±0.03–0.05°C (FC650) |
| Display Accuracy | ±0.15°C (FC140), ±0.2°C (FC350), ±0.5°C (FC650) |
| Heating Time | 15 min (−30°C → 140°C), 20 min (50°C → 350°C), 20 min (50°C → 650°C) |
| Cooling Time | 15 min (140°C → 0°C), 40 min (350°C → 100°C), 20 min (650°C → 300°C) |
| Calibration Well Dimensions | Ø25 mm × 148 mm depth |
| Power Consumption | 150 W (FC140), 750 W (FC350/FC650) |
| Dimensions (D×W×H) | 228 mm × 248 mm × 143 mm |
| Weight | 6.60 kg (FC140), 6.35 kg (FC350/FC650) |
| Traceability | UKAS-accredited calibration certificate available |
| Optional Interfaces | 4–20 mA input, RS232/USB communication, PC software for automated calibration routines, temperature switch testing, ramp-and-soak profiling |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 993, 996 |
| Instrument Type | Blackbody Calibrator |
| Temperature Range | −10 °C to 550 °C |
| Stability | ≤ 0.1 °C |
| Temperature Resolution | 0.01 °C |
| Warm-up Time | 40 min (from ambient to 80 °C) |
| Cool-down Time | 45 min (from ambient to −10 °C) |
| Operating Ambient Temperature | −29 °C to 50 °C |
| Cavity Aperture | 50 mm (Model 993), 65 mm (Model 996) |
| Emissivity | > 0.995 |
| Temperature Uniformity | ≤ ±0.15 °C or ±0.15% of reading (whichever is greater) |
| Enclosure Rating | IP56 |
| Interface | RS-232 |
| Internal Cavity Dimensions | 355 mm × 279 mm × 406 mm |
| External Dimensions (D×W×H) | 355 mm × 279 mm × 406 mm |
| Mass | 18.1 kg |
| Compliance | MIL-PRF-28800F, BS EN 60068-2-1:2007, BS EN 60068-2-14:2009, ISO 3744:2010 |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 786 / 787 |
| Instrument Type | Dry-Block Temperature Calibrator |
| Environmental Operating Range | −29 °C to +50 °C |
| IP Rating | IP56 |
| Calibration Well Dimensions (Model 786) | Ø29.4 mm × 203 mm depth |
| Calibration Well Dimensions (Model 787) | Ø25.4 mm × 152 mm depth |
| Stability (Model 786, A-type sensor) | ±0.008 °C |
| Stability (Model 787, B/S-type sensor) | ±0.01 °C to ±0.05 °C |
| Horizontal Uniformity (Model 786) | <0.008 °C |
| Vertical Uniformity (Model 787) | <0.5 °C |
| Heating Time (786 | −40 °C → 140 °C): 30 min |
| Heating Time (787 | −50 °C → 650 °C): 30 min |
| Cooling Time (787 | 650 °C → 100 °C): 90 min |
| Power Supply (786) | 85–264 V AC, 50/60 Hz, 360 W |
| Power Supply (787) | 110/230 V AC, 50/60 Hz, 800 W |
| Weight (786) | 16.8 kg |
| Weight (787) | 18 kg |
| Compliance | MIL-PRF-28800F, BS EN 60068-2-1 & -2-14, ISO 3744:2010 |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | ISOTECH Fixed-Point Blackbody Series (Indium, Zinc, Aluminum, Silver, Copper Points) |
| Cavity Diameter | 10 mm |
| Cavity Depth | 90 mm |
| Emissivity | >0.999 |
| Plateau Duration | >3 hours |
| Temperature Range | 156.60 °C (In) to 1084.62 °C (Cu) |
| High-Temperature Operation | Requires inert gas purge (N₂ or Ar) for Al/Ag/Cu points |
| R999 Mid-Temperature Reference Source | 30–550 °C, Cavity Ø45 mm × 285 mm depth |
| R426 High-Temperature Calibration Furnace | Sodium heat-pipe design, axial temperature gradient <0.01 °C/cm |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model Numbers | 17701, 17703, 465 |
| Application | High-Accuracy Temperature Fixed-Point Realization (In, Sn, Zn, Al) |
| Construction | Stainless Steel Core Tube with Parallel Wound Heating Element |
| Axial Temperature Gradient | <0.1 °C/cm in Working Zone |
| Plateau Duration | ≥20–40 h (dependent on cell type and thermal mass) |
| Control System | PID-Based Automatic Temperature Stabilization |
| Safety | Integrated Power-Fail Protection Circuitry |
| Compliance | Designed for use in accordance with ITS-90 realization protocols |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Type | Sealed or Open-Style Fixed-Point Cell |
| Certified Uncertainty | ±0.000070 °C (k = 1) |
| Purity | ≥99.99999% Ga (7N) |
| Compliance | Traceable to NPL and CIPM MRA |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 17402B |
| Operating Duration | 12–16 h |
| Cooling Initiation | Bottom-up thermal control |
| Compliance | Designed for ITS-90 fixed-point calibration workflows |
| Regulatory Context | Supports GLP-compliant temperature calibration traceability |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | Gemini4857-550/700 |
| Temperature Range | 35°C to 550°C / 50°C to 700°C |
| Stability | ±0.01°C @ 100°C, ±0.015°C @ 300°C, ±0.03°C @ 550°C |
| Temperature Resolution | 0.01°C |
| Heating Time (30°C → 550°C) | 35 min (standard), 60 min (LRIN) |
| (50°C → 700°C) | 110 min (standard), 120 min (LRIN) |
| Cooling Time (550°C → 275°C) | 35 min (standard), 132 min (LRIN) |
| (550°C → 60°C) | 345 min (standard), 420 min (LRIN) |
| Calibration Well Dimensions | Ø64 mm × 160 mm depth |
| External Dimensions (D×W×H) | 312 mm × 212 mm × 384 mm |
| Weight | 8.5 kg (standard), 14 kg (LRIN) |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | H4936 and D4934 |
| Instrument Type | Dry-Block Temperature Calibrator |
| Temperature Range | –20 °C to 142 °C (H4936), 30 °C to 250 °C (D4934) |
| Stability (Liquid Bath & Dry-Block Modes) | ±0.005 °C |
| Temperature Resolution | 0.001 °C (full scale) |
| Heating Time | –20 °C to 140 °C in 40 min (H4936) |
| Cooling Time | 140 °C to 20 °C in 90 min (H4936) |
| Horizontal Uniformity (Bath Mode) | <0.009 °C (H4936), <0.007 °C (D4934) |
| Vertical Uniformity (40 mm zone, Bath Mode) | <0.011 °C (H4936), <0.013 °C (D4934) |
| Calibration Well Dimensions | Ø65 mm × 160 mm depth |
| Input Channels | Thermocouples (E/J/K/N/R/S/T), RTDs (Pt100/Pt1000), (4–20) mA process signals, switch inputs |
| CJC Accuracy | ±0.35 °C |
| Display Resolution | 0.01 °C (–19.99 °C to 99.99 °C), 0.1 °C elsewhere |
| Display Accuracy | ±0.15 °C |
| Power Supply | 220 VAC, 50/60 Hz, 200 W (H4936), 1000 W (D4934) |
| Dimensions (H×W×D) | 384 × 212 × 312 mm |
| Weight | 12 kg (H4936), 8 kg (D4934) |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | ISOTower |
| Fixed-Point Options | Indium (156.5985 °C), Tin (231.928 °C), Zinc (419.527 °C), Aluminum (660.323 °C), Silver (961.78 °C) |
| Immersion Depth | 290 mm |
| Thermal Siphon Technology | Yes |
| Temperature Plateau Duration | ≥30 h |
| Ramp Time to Setpoint | ~2 h |
| Cell Purity | 99.9999% (6N) |
| Construction | Integrated crucible-furnace monoblock architecture |
| Compliance | Fully compatible with ITS-90 realization protocols |
| Brand | ISOTECH |
|---|---|
| Origin | USA |
| Model | Jupiter 4852 |
| Temperature Range | 35°C to 660°C |
| Stability | ±0.015°C @ 100°C, ±0.025°C @ 650°C |
| Temperature Resolution | 0.01°C (30–99.99°C), 0.1°C (other ranges) |
| Heating Time | <20 min (30°C to 650°C) |
| Cooling Time | <60 min (650°C to 150°C) |
| Calibration Well Dimensions | Ø35 mm × 148 mm depth |
| Well Insert Configuration | 6-hole standard block (2ר4.5 mm, 2ר6.4 mm, 1ר8.0 mm, 1ר9.5 mm |
| Display Units | °C, °F, K, %RH (via optional humidity module) |
| Input Channels | Dual sensor inputs + reference input |
| Thermocouple Support | E, J, K, N, R, S, T |
| RTD Support | Pt100, Pt1000 (2-/3-/4-wire) |
| Process Input | 4–20 mA (isolated) |
| CJC Accuracy | ±0.35°C |
| Power Supply | 220 VAC, 50/60 Hz, 1000 W |
| Dimensions (H×W×D) | 384 × 212 × 312 mm |
| Weight | 8.5 kg |
| Compliance | ASTM E2877, ISO/IEC 17025 (when used with accredited procedures), NIST-traceable calibration capability |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model Numbers | 785LA / 785MA / 785HA / 796LA / 796MA / 796HA / 813TPA / 820SRA |
| Temperature Range | −120 °C to +300 °C (model-dependent) |
| Stability | ±0.002 °C to ±0.015 °C |
| Uniformity | ≤0.002 °C to ≤0.015 °C |
| Calibration Volume | 15.0 L to 30.6 L (300 × 300 × 340 mm) |
| Noise Level | 48–62 dB(A) |
| Power Supply | 220 VAC, 50/60 Hz |
| Heating Power | 1.5–3.5 kW |
| Cooling Time (to min temp) | 30–240 min |
| Heating Time (to max temp) | 30–90 min |
| Interface | RS-232, USB |
| Display | Full-color programmable touchscreen |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 461 |
| Power Requirement | None |
| Operating Medium | Liquid Nitrogen (LN₂) |
| Construction | Stainless Steel Dewar Vessel with Insulated Lid |
| Calibration Reference Temperature | −196 °C (77 K) |
| Temperature Uniformity | ±0.05 °C (within central 25 mm axial zone, after thermal stabilization) |
| Probe Compatibility | Standard 6–8 mm diameter stem thermometers (glass, platinum resistance, thermocouple, or digital sensors) |
| Compliance | Designed in accordance with ISO/IEC 17025:2017 requirements for reference standards used in thermometer calibration |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | LTQC560 / HTQC550 |
| Temperature Range | −12 °C to 140 °C (LTQC560) / 30 °C to 350 °C (HTQC550) |
| Resolution | 0.1 °C (full scale) |
| Accuracy | ±0.1 °C to ±0.4 °C (comparative measurement) |
| Stabilization Time | 5 min |
| Heating Time | 9 min (0 °C → 100 °C for LTQC560 |
| Calibration Well Dimensions | Ø13 mm × 120 mm (LTQC560) / Ø25 mm × 120 mm (HTQC550) |
| Power Supply | 15 V DC or 100–240 V AC, 50/60 Hz (LTQC560) |
| Dimensions (H×W×D) | 65 mm × 152 mm × 175 mm |
| Weight | 1.5 kg |
| Interchangeable Well Inserts | LTQC560 — single Ø6.8 mm × 120 mm bore |
| HTQC550 — multi-bore | Ø8 mm × 115 mm, two Ø6.5 mm × 115 mm, two Ø4.5 mm × 115 mm |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | M510 & M511 |
| Temperature Range | 30–550 °C (M510), 50–700 °C (M511) |
| Stability (≥30 min) | ±0.03 °C (dry block mode), ±0.001 °C (ITS-90 fixed-point mode) |
| Calibration Well Dimensions | Ø45 mm × 285 mm depth |
| Standard Insert | 6 × Ø8 mm × 250 mm deep holes |
| Display Resolution | 0.01 °C (setpoint), 0.1 °C (readout) |
| Warm-up Time | ≤90 min (30 → 550 °C), ≤90 min (50 → 700 °C) |
| Cool-down Time | ≤5 h (550 → 30 °C) |
| Power Supply | 220 V, 1000 W, 50/60 Hz |
| Dimensions (H×W×D) | 430 × 310 × 300 mm |
| Weight | 17 kg (M510), 25 kg (M511) |
| Compliance | ITS-90 traceable operation, suitable for GLP/GMP environments requiring documented thermal stability and audit-ready calibration workflows |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 17724 |
| Certified Uncertainty | ±0.000220 °C |
| Purity | ≥99.99999% (7N) Mercury |
| Housing | Austenitic Stainless Steel (316L) |
| Thermometer Well Depth | Adjustable (Standard Depth: 150 mm, Customizable per ITS-90 Calibration Protocol) |
| Compliance | Fully Traceable to NPL and BIPM Standards |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | microK |
| Measurement Principle | Four-Terminal Resistance Ratio Metrology with Alpha-Delta ADC Architecture |
| Primary Application | Primary and Secondary Thermometry Calibration (SPRT, PRT, Thermistors, Thermocouples) |
| Channel Capacity | 3 Parallel Input Channels (Expandable to 90 via External Multiplexers) |
| Display | 6.4" TFT Color Touchscreen Running Windows CE |
| Data Export | Native Excel (.xls) Format via USB Storage |
| Terminal Interface | Gold-Plated Tellurium-Copper CablePod™ Sockets Accepting 4 mm Banana, Flat Blade, and Bare Wire |
| Thermal EMF Performance | < 0.1 µV Typical Contact EMF |
| Stability | < 3 ppm/year Voltage Drift |
| Compliance | Designed for ISO/IEC 17025 Accredited Laboratories |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | microK² |
| Instrument Type | Precision Temperature Bridge for SPRT, Thermocouples & Thermistors |
| Accuracy | 0.03 ppm (equivalent to 7.5 µK at 273.16 K) |
| Channels | 4-wire resistance measurement with 4 independent measurement channels |
| Display | 10.1-inch capacitive touchscreen (1280 × 800 resolution) |
| Interfaces | Ethernet, dual RS-232, three USB ports |
| Software | ISOTECH BridgeControl™ v3.0 (FDA 21 CFR Part 11 compliant, audit trail enabled) |
| Compliance | Fully supports JJF 2189–2025, ISO/IEC 17025, ASTM E1137/E220, IEC 60751, and ITS-90 traceability requirements |
| Application Domain | Primary and secondary temperature calibration laboratories, national metrology institutes, pharmaceutical QC, aerospace thermal validation |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | milliK |
| Temperature Measurement Principle | Thermocouple (and RTD, Thermistor, 4–20 mA, mV) |
| Operating Temperature Range | −270 °C to +1820 °C |
| Display Units | °C, °F, K, Ω, mA, mV |
| Data Logging | Internal memory + USB export |
| Channel Capability | Simultaneous multi-channel measurement and display |
| Compliance | Designed for metrological traceability in calibration laboratories |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Product Type | Portable Dry-Block Temperature Calibration System |
| Primary Components | Millik Precision Thermometer + ISOTECH Dry-Block Furnace (Model B) |
| Temperature Range | −45 °C to 1200 °C |
| Measurement Channels | 3 independent inputs (simultaneous differential measurement supported) |
| Input Types | Thermocouples (all standard types), RTDs (Pt100, Pt1000), Thermistors (2-wire/3-wire/4-wire), and 4–20 mA current loops |
| Internal Reference | Built-in ITS-90 temperature conversion algorithms |
| Compliance | Designed for traceable calibration per ISO/IEC 17025, ASTM E2877, and IEC 60584 |
| Software Interface | USB and RS232 connectivity with optional ISOTECH CalSoft™ for automated calibration reporting and audit trails |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 17725 |
| Temperature Setpoint Range | −36 °C to −42 °C |
| Cooling Time to Setpoint | ≤60 min |
| Cooling Rate | up to 1 K/min |
| Heating Rate | up to 2 K/min |
| Construction | Laboratory-grade stainless steel housing with insulated cryogenic chamber |
| Control System | Digital PID temperature controller with ±0.01 °C stability (at setpoint) |
| Compliance | Designed for use with ITS-90 traceable mercury triple-point cells (234.3156 K) |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 414 |
| Maximum Operating Temperature | 1000 °C |
| Control System | Integrated Programmable Temperature Controller |
| Application | Annealing, Heat Treatment and Stabilization of Platinum Resistance Thermometers (PRTs) |
| Compliance | Designed for use in calibration laboratories adhering to ISO/IEC 17025, ASTM E1137/E2877, and IEC 60751 |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 459 |
| Temperature Range | −180 °C to −80 °C |
| Stability (30 min) | ±0.005 °C at −80 °C |
| Uniformity (between wells) | ±0.005 °C |
| Uniformity (axial, 50 mm from bottom) | ±0.005 °C at −80 °C |
| Immersion Depth | 560 mm |
| Well Diameter | 80 mm |
| Well Length | 480 mm |
| Number of Probe Wells | 4 |
| Neck Diameter | 120 mm |
| Vacuum Port Interface | RS-422 |
| Cooling Medium | Liquid Nitrogen |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 471 |
| Temperature Fixed Point | Argon Triple Point (−189.3442 °C) |
| Uncertainty (k=2) | 1.844 mK |
| Plateau Duration | ≥4 h |
| Accuracy | ±1 mK |
| Dimensions (H×W×D) | 1250 × 380 × 615 mm (Apparatus Height: 900 mm) |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 580 |
| Temperature Range | −25 °C to +140 °C |
| Accuracy | ±0.1 °C (standard mode), ±0.04 °C (high-stability mode) |
| Uniformity | ±0.05 °C |
| Stability (30 min) | ±0.03 °C (dry-block), ±0.025 °C (stirred liquid bath), ±0.001 °C (ice/water bath), ±0.3 °C (blackbody), ±0.5 °C (surface sensor), ±0.0002 °C (ITS-90 fixed points) |
| Calibration Well Dimensions | Ø50 mm × 300 mm depth |
| Standard Insert | 6-hole, Ø8.0 mm × 250 mm depth |
| Display Resolution | 0.01 °C (−19.99 to 99.99 °C), 0.1 °C (100.0 to 140.0 °C) |
| Communication Interface | RS232 |
| Power Supply | 208–240 V AC, 50/60 Hz, 300 W |
| Dimensions (H×W×D) | 430 × 310 × 300 mm |
| Weight | 17 kg |
| Cooling Time (20 °C → −10 °C) | 90 min |
| Heating Time (−10 °C → 80 °C) | 60 min |
| Units | °C, °F, K |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 820 |
| Temperature Range | 30 °C to 200 °C |
| Temperature Stability | ±0.01 °C |
| Tank Capacity | 36 L |
| Circulation Method | Propeller-driven forced convection |
| Fluid Compatibility | Water, silicone oil, and other low-volatility heat-transfer fluids |
| Compliance | Designed for ISO/IEC 17025-compliant calibration laboratories |