Jianhu
Filter
Showing 121–150 of 440 results
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor & OEM Partner |
| Country of Origin | China |
| Model | JH-2026 |
| Price Range | USD 850–8,500 (FOB Shanghai) |
| Temperature Range | −70 °C to +150 °C |
| Refrigeration Method | Dual-stage Mechanical Compression System |
| Explosion-Proof Configuration | Available (ATEX/IECEx-compliant variant) |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C (per IEC 60068-3-5) |
| Temperature Deviation | ±2.0 °C (at load center) |
| Heating Rate | ≤60 min (−70 °C → +150 °C) |
| Cooling Rate | ≤45 min (25 °C → −70 °C), ≤60 min (150 °C → −70 °C), ≤80 min (full thermal shock cycle per MIL-STD-810H Method 503.5) |
| Interior Dimensions | Custom-engineered (standard base: W600 × D600 × H600 mm |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor & OEM Partner |
| Country of Origin | China |
| Model | JH-2026 |
| Price Range | USD 850 – 8,500 (FOB Shanghai) |
| Temperature Range | -70°C to +150°C |
| Refrigeration Method | Dual-Stage Mechanical Compression System |
| Explosion-Proof Certification | Ex d IIB T4 Gb / Ex tb IIIC T135°C Db (IEC 60079-0, -1, -31) |
| Temperature Fluctuation | ±0.5°C (at setpoint, steady state) |
| Temperature Uniformity | ±2.0°C (per IEC 60068-3-5) |
| Temperature Deviation | ±2.0°C (per IEC 60068-3-10) |
| Heating Rate | ≤60 min (from -40°C to +150°C, empty chamber) |
| Cooling Rate | ≤45 min (from +150°C to -40°C), ≤60 min (-40°C to -70°C), ≤80 min (full thermal span) |
| Interior Dimensions | Custom-engineered per user specification (L×W×H in mm) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor & OEM Partner |
| Product Category | Optical Property Testing Instrument |
| Model | JH-2026 |
| Price Range | USD 700 – 7,000 |
| Compliance | ISO 13468-1, ISO 14782, ASTM D1003, GB/T 2410, JJG 696 |
| Brand | Jianhu |
|---|---|
| Model | JH-250F |
| Temperature Range | 0–60 °C |
| Humidity Range (with humidification) | 60–90 %RH |
| Humidity Range (without humidification) | 10–45 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Fluctuation | ±5–8 %RH |
| Power Supply | 220 V, 50 Hz |
| Input Power | 680 W |
| Inner Chamber Dimensions (W×D×H) | 52×46×105 cm |
| Outer Dimensions (W×D×H) | 62×69×159 cm |
| Standard Shelves | 2 pcs |
| Timer Range | 1–9999 min |
| Optional Features | Independent Over-Temperature Alarm System |
| Brand | Jianhu |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JH-350F |
| Temperature Range | RT+10°C to 200°C (optional 300°C) |
| Temperature Uniformity | ±1% |
| Temperature Control | PID + SCR with LED Digital Display |
| Sensor | PT-100 Platinum Resistance Thermometer (0.1°C resolution) |
| Air Exchange Rate | 0–200 cycles/hour (adjustable via calibrated knob, with digital wattmeter for power and airflow correlation) |
| Internal Dimensions (Standard) | 450 × 450 × 450 mm |
| External Dimensions (Standard) | 1070 × 1440 × 690 mm |
| Compliance | GB/T 2951, ISO 188, ASTM D573, ASTM D865, UL 1581, EN 60811, CEN/TS 15371 |
| Brand | Jianhu |
|---|---|
| Model | JH-501A |
| Type | Circulating Water Bath (Internal & External Loop) |
| Temperature Range | RT+5°C to 100°C |
| Stability | ±0.5°C |
| Resolution | 0.1°C |
| Power Input | 550 W |
| Chamber Volume | 11 L |
| Chamber Dimensions (W×D×H) | 420×180×150 mm |
| External Dimensions (W×D×H) | 570×270×260 mm |
| Material | Stainless Steel Interior & Exterior |
| Control | Digital Microprocessor with Timer (1–999 min) |
| Safety | Over-Temperature Audio-Visual Alarm |
| Compliance | Designed for GLP-aligned lab environments |
| Origin | Zhejiang, China |
| Distribution | Authorized Distributor |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-6017 |
| Max. Test Load | 65 kgf |
| Drop Height Range | 45–200 cm |
| Drive System | Motorized Vertical Lift |
| Drop Release | Electromagnetic Holding & Instant Free-Fall |
| Impact Surfaces | Flat Face, Edge (Line), and Corner |
| Height Display | Digital LED Indicator |
| Base Construction | Solid Steel Base with Four Adjustable Leveling Feet |
| Safety Protection | Upper/Lower Limit Microswitches |
| Accessories | 250 cm Calibration Tape with Scale Pointer |
| Compliance | Designed for ISO 2233, ASTM D5276, ISTA 1A/2A/3A, GB/T 4857.5 |
| Brand | Jianhu |
|---|---|
| Origin | Chongqing, China |
| Model | JH-6030A |
| Instrument Type | Vacuum Oven |
| Temperature Range | +5 °C to 40 °C (Operating Ambient) / RT+10 °C to 250 °C (Chamber Setpoint) |
| Temperature Uniformity | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Achievable Vacuum Level | 133 Pa |
| Internal Chamber Dimensions (W×D×H) | 320 mm × 320 mm × 300 mm |
| External Dimensions (W×D×H) | 630 mm × 490 mm × 450 mm |
| Input Power | 2000 W |
| Power Supply | 220 V, 50 Hz |
| Door Seal | Integrated Silicone Gasket |
| Viewing Window | Dual-Layer Tempered Glass |
| Inert Gas Port | Standard Fitting |
| Chamber Material | Stainless Steel (304) |
| Shelf Quantity | 4 pcs |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Jianhu |
|---|---|
| Origin | Chongqing, China |
| Model | JH-6090 |
| Instrument Type | Forced-Air Drying Oven |
| Temperature Range | RT+10°C to 200°C |
| Temperature Uniformity | ±1°C (at 100°C) |
| Temperature Fluctuation | ±0.1°C (short-term stability) |
| Internal Chamber Dimensions | 450 × 450 × 450 mm (W×D×H) |
| External Dimensions | 610 × 680 × 1460 mm (W×D×H) |
| Chamber Material | Mirror-Finish Stainless Steel (SUS304) |
| Door Configuration | Double-Door with Dual-Layer Heat-Resistant Glass Window |
| Sealing | High-Performance Silicone Gasket |
| Heating System | Embedded Coiled Tubular Electric Heaters |
| Air Circulation | Centrifugal Low-Noise Blower, Forced Convection |
| Controller | Digital Microprocessor-Based PID Temperature Controller with Timer Function |
| Safety Features | Independent Over-Temperature Protection Circuit |
| Brand | Jianhu |
|---|---|
| Model | JH-60T |
| Type | Electromechanical Universal Testing Machine |
| Load Capacity | 5 kN |
| Force Sensor Standard | 2 kg (20 N), optionally upgradable with additional sensors |
| Force Accuracy Class | 0.2 |
| Force Measurement Range | 0.4–100% FS |
| Force Resolution | ±1/300,000 of full scale, unsegmented throughout range |
| Deformation Measurement Range | 0.2–100% FS |
| Deformation Error | < ±0.2% of reading |
| Deformation Resolution | ±1/300,000 of maximum deformation |
| Displacement Accuracy | ±0.2% of reading |
| Displacement Resolution | 0.02 µm |
| Crosshead Speed Range | 0.001–200 mm/min |
| Speed Control Accuracy | ±0.2% of set value |
| Strain Rate Range | 0.001–2% FS/min |
| Strain Rate Control Accuracy | ±0.2% of set value |
| Effective Test Width | 370 mm or 210 mm (configurable) |
| Max Tensile Travel | 700 mm or 1200 mm (configurable) |
| Max Compression Stroke | 700 mm |
| Control System | Full PC-based closed-loop control |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 0.4 kW |
| Machine Weight | 160 kg |
| Dimensions (W×D×H) | 800 × 410 × 1600 mm |
| Compliance | GB/T 228.1, ISO 6892-1, ASTM E8/E21, JIS Z2241, DIN 50125 |
| Brand | Jianhu |
|---|---|
| Model | JH-7035-UB |
| Origin | Beijing, China |
| Light Source | UV fluorescent lamp (UVA-340 or UVB-313 configurable) |
| Internal Chamber Dimensions | 460 × 300 × 875 mm / 500 × 500 × 1500 mm |
| External Dimensions | 650 × 400 × 1125 mm / 1000 × 650 × 3500 mm |
| Temperature Range | Ambient to 200 °C |
| UV Irradiance | Adjustable via electronic controller |
| Sample Tray | Motor-driven rotating turntable (360° continuous rotation) |
| Timer | Digital electronic timer (0–999.9 h) |
| Power Supply | 220 V AC, 50 Hz |
| Net Weight | 15 kg / 140 kg (depending on configuration) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-8000 Series |
| Load Capacity | 0–500 kgf to 30,000 kgf (configurable by model) |
| Load Accuracy | ±0.25% (servo models) or ±1% (economy/microcomputer models) |
| Test Speed Range | 0.001–1000 mm/min (model-dependent) |
| Crosshead Travel | 150–1000 mm (selectable) |
| Effective Width | 400–500 mm |
| Drive System | Panasonic AC servo motor (JH-8000, JH-8000A, JH-8010) or AC frequency inverter motor (JH-8003/04/07/08) |
| Control Interface | Dell PC with proprietary software (high-end models) or large LCD + dual digital display (economy/microcomputer models) |
| Frame Type | Dual-column portal (JH-8000/JH-8000A/JH-8001) or single-column (JH-8010/JH-8002/JH-8003–JH-8007) or horizontal/desktop (JH-8006/JH-8008) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Domestic Distributor |
| Product Origin | China |
| Model | JH-8006 |
| Pricing | Upon Request |
| Capacity | 50 kgf |
| Resolution | 1/200 |
| Stroke | 150 mm |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-8006 |
| Max. Specimen Weight | 300 kg |
| Drop Height Range | 0–2000 mm |
| Max. Specimen Dimensions | 1000 × 1000 × 800 mm |
| Test Orientations | Face, Edge, Corner |
| Power Supply | 380 V / 50 Hz |
| Drive System | Motor-driven with Pneumatic Acceleration & Electromagnetic Release |
| Impact Plate Material | Solid 45# Steel Plate |
| Height Display | Digital LCD with Programmable Setpoint |
| Height Indication | Calibrated Scale Bar |
| Guiding Mechanism | Imported Taiwan Linear Slides + Bronze Bushings |
| Drop Arm Frame | Welded Square Tubular 45# Steel Structure |
| Acceleration Mechanism | Pneumatic Assist |
| Release Mechanism | Electromagnetic Trigger |
| Safety Protection | Dual Inductive Sensors (Upper/Lower Limit) |
| Damping System | High-Efficiency Shock Absorbers |
| Net Weight | ~1500 kg |
| Rated Power | 5 kW |
| Compliance Standard | GB/T 1019–2008 |
| Brand | Jianhu |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JH-8126 |
| Power Supply | 220 V / 50 Hz |
| Fuel Source | Town Gas or Liquefied Petroleum Gas (LPG) |
| Combustion Chamber Dimensions | 385 mm (L) × 204 mm (D) × 360 mm (H) |
| Ventilation | 10 × Ø19 mm floor holes + 13 mm perimeter slot near top |
| Burner Nozzle ID | 9.5 mm |
| Flame Impingement Height | 19 mm below free end centerline of specimen |
| Timer Range | 0–99.99 s/min/h |
| Temperature Probe Port | Centered 20 mm from rear inner wall at top surface |
| Combustion Support | Four 10 mm-height stainless steel feet |
| Test Accessory Specifications | Metal comb ≥110 mm long, 7–8 smooth round teeth per 25 mm |
| Ventilation Hood Requirement | Volume = 20–110× combustion chamber volume |
| Brand | Jianhu |
|---|---|
| Model | JH-9008 |
| Drop Height Range | 300–1500 mm |
| Height Display | Digital |
| Height Accuracy | ±10 mm |
| Max Specimen Weight | 10 kg |
| Support Plate Dimensions | 220 × 200 × 12 mm |
| Impact Base Plate Dimensions | 550 × 650 × 20 mm |
| Overall Dimensions (approx.) | 650 × 560 × 2260 mm |
| Control Cabinet Dimensions (approx.) | 350 × 350 × 1000 mm |
| Height Adjustment | Motorized Drive |
| Drop Orientation | Face, Edge, Corner (Pneumatic Release) |
| Operating Pressure | ~0.8 MPa (8 bar) |
| Net Weight (approx.) | 70 kg |
| Power Supply | 220 VAC ±10% |
| Compliance Standard | GB/T 2423.8 |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-9050 |
| Heating Method | Water-jacketed |
| Inner Chamber Dimensions (W×D×H) | 350 × 350 × 410 mm |
| Outer Dimensions (W×D×H) | 510 × 500 × 700 mm |
| Power Consumption | 460 W |
| Temperature Range | RT + 5 °C to 65 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Timer Range | 1–9999 min |
| Chamber Material | Mirror-finish stainless steel (AISI 304) |
| Exterior Finish | Powder-coated mild steel |
| Door Configuration | Dual-door (outer insulated door + inner tempered glass door) |
| Shelf Capacity | 2 adjustable stainless steel shelves |
| Power Supply | 220 V ±10%, 50 Hz ±0.5 Hz |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Compliance | Designed per general laboratory equipment safety and performance expectations for Class II incubators under GB/T 14710 (Chinese national standard for environmental adaptability of medical electrical equipment), with optional RS485 interface supporting Modbus RTU protocol for integration into centralized lab monitoring systems |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-ASS (Acetic Acid Salt Spray) |
| Spray Method | Continuous Atomization |
| Spray Rate | 1–2 mL/(80 cm²·h) |
| Nozzle Pressure | 0.7–1.0 kgf/cm² |
| Fog Removal | Pneumatic Air-Compression Exhaust |
| Salt Fog Deposition Rate | 1–2 mL/(80 cm²·h) |
| Test Chamber Temperature Range | 35 °C ±2 °C |
| Compliance | ASTM B117, ISO 9227, GB/T 2423.17, JIS Z2371 |
| Control System | Microprocessor-Based PID Controller with Touchscreen HMI |
| Chamber Construction | PVC-Coated Steel Frame with Transparent Acrylic Viewing Window |
| Internal Volume | ≥200 L (Standard Configuration) |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JH-ATL Series |
| Temperature Range | -70 °C to +150 °C |
| Refrigeration Method | Compressor-Based Cooling |
| Explosion-Proof Design | Yes |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Deviation | ±2.0 °C |
| Heating Rate | ≤60 min (from -40 °C to +85 °C) |
| Cooling Rate | ≤45–80 min (depending on test profile and chamber load) |
| Internal Chamber Dimensions | Customizable |
| Brand | Jianhu |
|---|---|
| Model | JH-B4C |
| Chamber Type | Two-Zone Horizontal Thermal Shock Chamber |
| Internal Dimensions (W×D×H) | 500 × 400 × 400 mm |
| High-Temperature Zone Range | +60 °C to +150 °C |
| Low-Temperature Zone Range | –10 °C to –65 °C |
| Temperature Transition Time (–55 °C ↔ +150 °C) | ≤15 s |
| Control System | PID-based Touchscreen Color LCD Controller |
| Compliance | Meets ASTM D5229, ISO 16750-4, MIL-STD-810H Method 503.5, GB/T 2423.22 |
| Third-Party Calibration | Verified by Shanghai Institute of Measurement and Testing Technology (SIMT) |
| CNAS Lab Deployment | Installed in >500 accredited laboratories nationwide |
| Sample Mounting | Static test specimen configuration with external wiring ports |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Jianhu JH-Battery Dual-Chamber High-Low Temperature Test Chamber |
| Price Range | USD 1,100 – 11,000 |
| Temperature Range | −70 °C to +150 °C |
| Refrigeration Method | Compressor-Based Cooling |
| Explosion-Proof Design | Yes |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Deviation | ±2.0 °C |
| Heating Rate | ≤60 min (−40 °C to +85 °C) |
| Cooling Rate | ≤45–80 min (room temp to −40 °C) |
| Interior Dimensions | Customizable (Standard Options: Upper Chamber 200 L / Lower Chamber 300 L) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JH-Battery Multi-Environment Composite Test Chamber |
| Temperature Range | -70 °C to +150 °C |
| Refrigeration Method | Compressor-based |
| Explosion-Proof Rating | ATEX Ex d IIB T4 certified |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Deviation | ±2.0 °C |
| Heating Rate | ≤60 min (from -40 °C to +85 °C) |
| Cooling Rate | ≤45–80 min (depending on configuration) |
| Chamber Dimensions | Customizable (Small / Medium / Large) |
| Brand | Jianhu |
|---|---|
| Model | JH-BT Series |
| Temperature Range | -70°C to +150°C |
| Cooling Method | Compressor-based Refrigeration |
| Explosion-Proof Design | Yes |
| Temperature Fluctuation | ±0.5°C |
| Temperature Deviation | ±2.0°C |
| Temperature Uniformity | ±2.0°C |
| Transfer Time (Two-Zone Design) | ≤10 s |
| Stabilization Time | ≤5 min |
| Compliance | IEC 60068-2-14, IEC 60068-2-15, GB/T 2423.22, GB/T 2423.34 |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-BT Series |
| Temperature Range | -70 °C to +150 °C |
| Refrigeration Method | Compressor-based |
| Explosion-Proof Design | Yes |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Deviation | ±2.0 °C |
| Heating Rate | ≤60 min (from -40 °C to +85 °C) |
| Cooling Rate | ≤45–80 min (depending on test profile and load) |
| Chamber Dimensions | Customizable internal workspace |
| Control Response Time | Millisecond-level sensor feedback and actuator activation |
| Safety Architecture | Full-cycle closed-loop safety monitoring with real-time gas detection, emergency power cutoff, thermal runaway suppression, and remote IoT alerting |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-BT Series |
| Temperature Range | -70 °C to +150 °C |
| Refrigeration Method | Compressor-based Cooling |
| Explosion-Proof Design | Yes |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Deviation | ±2.0 °C |
| Heating Rate | ≤60 min (from -40 °C to +85 °C) |
| Cooling Rate | ≤45 min (from +85 °C to -40 °C) |
| Interior Dimensions | Customizable (Small / Medium / Large) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-BT-RTS Series |
| Temperature Range | -70 °C to +150 °C |
| Refrigeration Method | Compressor-based Cooling |
| Explosion-Proof Design | Yes |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Deviation | ±2.0 °C |
| Temperature Uniformity | ±2.0 °C |
| Heating Rate (Typical) | ≤60 min (from –40 °C to +85 °C) |
| Cooling Rate (Typical) | ≤45 min / ≤60 min / ≤80 min (depending on configuration and load) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Type | Neutral Salt Spray (NSS) Test Chamber |
| Spray Mode | Continuous Atomization |
| Fog Deposition Rate | 1–2 mL/(80 cm²·h) |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| De-fogging Method | Air-Pressure Exhaust |
| Temperature Control Range | 35 °C ±2 °C |
| Compliance | ISO 9227, GB/T 10125, ASTM B117 (NSS mode) |
| Construction | Industrial-grade stainless steel chamber with PID-controlled heating and corrosion-resistant internal components |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-CL5G |
| Temperature Range | -70 °C to +150 °C |
| Refrigeration Method | Compressor-based |
| Explosion-Proof Design | Yes |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Deviation | ±2.0 °C |
| Heating Rate | ≤60 min (from -40 °C to +85 °C) |
| Cooling Rate | ≤45–80 min (depending on setpoint and load) |
| Chamber Dimensions | Customizable internal workspace |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor & OEM Partner |
| Country of Origin | China |
| Model | JH-ClimatePro Series |
| Price Range | USD 480 – 4,800 |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-Composite Salt Spray Corrosion Test Chamber |
| Chamber Volume | 6 m³ |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–2 mL / 80 cm²·hr |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| Fog Removal Method | Air-Pressure Exhaust System |
| Construction Material | Interior – ASTM A240 Grade 316L Stainless Steel |
| Compliance | ISO 9227, ASTM B117, ASTM G85 (Annex A2–A5), IEC 60068-2-11, GB/T 2423.17, GB/T 2423.18 |
| Control Accuracy | Temperature ±0.1°C, Humidity ±2% RH |
| Configuration | Multi-Zone Independent Spray Control, Modular Environmental Simulation |