| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V8.0 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (145 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Display | 10-inch true-color touchscreen |
| Enclosure Rating | IP54 |
| Weight | 12 kg |
| Dimensions (L×W×H) | 480 × 300 × 190 mm |
| Compliance | CE certified, compliant with EU GMP Annex 1, USP <1207>, EP 5.1.1, FDA 21 CFR Part 11, ISO 13408-2 |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V8.0 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (145 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Display | 10-inch true-color touchscreen |
| Data Storage Capacity | >300,000 test records |
| Ingress Protection Rating | IP54 |
| Dimensions | 480 × 300 × 190 mm |
| Weight | 12 kg |
| Interface Options | RS232, USB, configurable industrial bus (optional), wireless communication (optional) |
| Regulatory Compliance | CE certified, FDA 21 CFR Part 11 compliant, GMP-aligned audit trail and electronic signature support |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V8.0 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (max. 145 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Display | 10-inch true-color touchscreen |
| Enclosure Rating | IP54 |
| Dimensions | 480 × 300 × 190 mm |
| Weight | 12 kg |
| Compliance | CE certified, FDA 21 CFR Part 11 compliant, GMP-aligned |
| Data Interface | RS232, USB, configurable industrial bus & wireless options (optional) |
| Maximum Test Configuration | 12-cartridge, 20-inch filter housing |
| Sensor Accuracy | High-precision pressure transducers with <±0.5% FS deviation |
| Audit Trail | Built-in, time-stamped, immutable event logging with user attribution |
| Language Support | English / Chinese |
| Pressure Units | mbar, kPa, psi, kgf/cm² |
| User Management | Four-tier role-based access control with customizable permissions and electronic signature support |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | V1.1 |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| Operating Pressure Range | 500–6900 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±75 mbar |
| Dimensions (W×D×H₁×H₂) | 400 × 380 × 100 × 235 mm |
| Display | 73 × 39 mm monochrome LCD |
| Ambient Operating Conditions | 5–35 °C, 10–80% RH |
| Test Duration (Rapid Bubble Point) | 9 ± 2 min |
| Test Duration (Bubble Point Scan) | 20 ± 2 min |
| Data Storage | 20 test records |
| Print Output | Integrated thermal printer (English language support) |
| Compliance | Designed to meet USP <1207>, ASTM F838-22, ISO 13408-2, and FDA 21 CFR Part 11 requirements for audit trail and electronic record integrity |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V1.2 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar (115 psi) |
| Bubble Point Accuracy | ±75 mbar |
| Diffusion Flow Accuracy | ±4% |
| Bubble Point Range | 590–6900 mbar |
| Diffusion Flow Range | 1–180 mL/min |
| Display | 3.2″ monochrome LCD |
| Data Storage | 20 test records |
| Dimensions (L×W×H) | 400 × 240 × 270 mm (main unit) + 220 mm (height with printer) |
| Weight | 7.5 kg |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Compliance | FDA, USP <1207>, ISO 13408-2, Annex 1 (2022), and Chinese Pharmacopoeia (ChP) 2020 Edition |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V3.0 |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| Dimensions (W×D×H) | 400 × 380 × 235 mm (height includes dual-level chassis design) |
| Test Pressure Range | 100–8000 mbar (1.5–116 psi) |
| Bubble Point Accuracy | ±50 mbar |
| Diffusion Flow Accuracy | ±4% |
| Net Volume Measurement Accuracy | ±4% |
| Test Duration (typical) | Bubble Point: 15 ±2 min |
| Enhanced Bubble Point | 20 ±2 min |
| Diffusion Flow | 10 ±2 min |
| Net Volume Determination | 5 ±2 min |
| Operating Environment | 5–35 °C, 10–80% RH |
| Data Storage | 500 test records with full pressure-time curves |
| Display | 5.7" monochrome TFT LCD with backlight |
| Interface | RS232 serial port |
| Language Support | English, Chinese |
| Compliance | Meets requirements of USP <1207>, ISO 13408-2, ASTM F838-22, and EU GMP Annex 1 for sterile filtration validation |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | Integtest™ V4.0 Portable |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| Operating Pressure Range | 100–6900 mbar |
| Pressure Resolution | ±1.0 mbar |
| Bubble Point Accuracy | ±75 mbar |
| Test Duration (Rapid Bubble Point) | 8 ± 2 min |
| Test Duration (Bubble Point Scan) | 20 ± 2 min |
| Ambient Operating Conditions | 5–35 °C, 10–80% RH |
| Display | Monochrome LCD, 73 × 39 mm with backlight |
| Data Storage | 20 test records |
| Print Output | Integrated Chinese-language thermal printer |
| Dimensions (W × D × H₁ × H₂) | 400 × 380 × 100 × 235 mm |
| Weight | Approx. 8.2 kg |
| Compliance | Designed to support FDA 21 CFR Part 11 readiness, USP <1207>, ISO 13408-2, and Annex 1 (2022) requirements for sterile filtration validation |
| Brand | NeuronBC |
|---|---|
| Model | JWG-7A |
| Measurement Principle | Laser Light Obscuration (Single-Particle Counting) |
| Detection Range | 1–500 µm |
| Channel Configurations | ≥5 µm, ≥10 µm, ≥25 µm, 15–25 µm, 25–50 µm, 51–100 µm, >100 µm (user-definable up to 16 channels) |
| Minimum Sample Volume | ≥0.1 mL |
| Particle Count Capacity | 0–9,999,999 particles per sample |
| Concentration Range | 0–10,000 particles/mL |
| RSD | ≤2% (for NIST-traceable standard latex particles ≥1000 particles/mL) |
| Accuracy | ±5% of reference value |
| Channel Resolution | ≥95% (≥10 µm channel) |
| Sampling Time | <10 s for 5 mL |
| Stirring Speed | 0–2000 rpm (adjustable glass propeller stirrer) |
| Operating Temperature | 0–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤90 W |
| Dimensions | 390 × 350 × 470 mm |
| Compliance | GB 8368–2005, GB 8368–2018, GB 8368–1998 (Medical Devices & Pharmaceutical Packaging Materials), ISO 21501-4, USP <788> and <789> (with method validation), FDA 21 CFR Part 11-ready (JWG-7DS variant) |
| Brand | NeuronBC |
|---|---|
| Model | JWG-8A |
| Origin | Beijing, China |
| Compliance | Chinese Pharmacopoeia (2015 Edition), USP <788>, USP <789>, ISO 21501-4 |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Sample Volume Range | 0.1–25 mL (adjustable via interchangeable high-pressure syringe pumps) |
| Laser Source | Imported stabilized diode laser (650 nm, Class 1) |
| Particle Size Range | 2–100 µm (calibrated with NIST-traceable polystyrene latex standards) |
| Sensitivity | ≥90% counting efficiency for particles ≥10 µm |
| Flow Cell Material | 316L stainless steel + PTFE-wetted path |
| Stirring System | Variable-speed glass paddle stirrer (0–300 rpm, ±2 rpm control accuracy) |
| Display | 10.1″ capacitive color touchscreen (1280×800) |
| Data Storage | Internal SSD (≥64 GB), supports CSV/PDF export |
| Software | NeuronBC PartiView™ v3.2 (audit-trail enabled in “S” variant), 21 CFR Part 11 compliant modules available |
| Connectivity | USB 3.0, Ethernet, RS-232 |
| Environmental Operation | 5–40 °C, 20–85% RH, altitude-independent performance (0–5000 m ASL) |
| Regulatory Support | IQ/OQ/PQ documentation package available |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | MFT-1000 |
| Detection Principles | Vacuum Decay & Pressure Decay |
| Compliance | USP <1207>, ASTM F2338-22, FDA 21 CFR Part 11, GMP Annex 1 (2022), ISO 15378:2017 |
| Test Range | −0.1 to 1.0 MPa (selectable ranges) |
| Differential Pressure Sensor | ±2 kPa, accuracy ≤0.5% FS, resolution 0.1 Pa |
| Minimum Detectable Equivalent Orifice Diameter | 1–2 µm |
| Display | 10-inch color capacitive touchscreen |
| Power | AC 100–240 V, 50/60 Hz, ≤200 W |
| Enclosure Rating | IP54 |
| Data Retention | ≥10 years (audit trail + event logs) |
| User Management | 4-tier role-based access control with customizable permissions |
| Output Interfaces | 4–20 mA, RS485, Ethernet, USB, 12 V alarm |
| Data Export | Raw test data, metadata, configuration files via USB |
| Optional Connectivity | Wireless module (Wi-Fi/Bluetooth), OPC UA, MQTT support |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | MFT-900 |
| Detection Principle | Vacuum Decay / Differential Pressure |
| Compliance | USP <1207>, ASTM F2338-22, FDA Guidance on CCIT |
| Max Test Pressure Range | -0.1 to 1.0 MPa |
| Minimum Detectable Leak Size | 2 µm equivalent hole diameter |
| Pressure Sensor Accuracy | ±0.5% F.S. (differential), ±1% F.S. (test pressure) |
| Differential Pressure Resolution | 0.1 Pa |
| Touchscreen | 10-inch color LCD |
| Power | AC 100–240 V, 50/60 Hz, ≤200 W |
| Audit Trail Retention | ≥5 years |
| User Access Levels | 4-tier role-based authentication |
| Data Export | USB flash drive |
| Communication Interfaces | Ethernet, RS485, 4–20 mA analog output, 12 V alarm signal |
| Optional Accessories | Certified reference leak standards (NIST-traceable), custom test chambers, method validation support services |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | MFT-900 |
| Detection Principle | Vacuum Decay / Differential Pressure |
| Compliance | USP <1207>, ASTM F2338-22, FDA Guidance on Container Closure Integrity Testing (CCIT) |
| Test Range | −0.1 to 1.0 MPa (selectable), Differential Pressure Sensor: ±2 kPa, Accuracy ≤0.5% F.S., Resolution: 0.1 Pa |
| Minimum Detectable Leak Equivalent Hole Diameter | 2 µm |
| Touchscreen | 10-inch Color TFT LCD |
| Power | AC 100–240 V, 50/60 Hz, ≤200 W |
| Audit Trail Retention | ≥5 years |
| User Access Control | 4-tier Role-Based Authentication |
| Data Export | USB drive, CSV format |
| Communication Interfaces | Ethernet, RS485, 4–20 mA analog output, 12 V alarm signal |
| Optional Accessories | Certified Standard Leak Reference Vials (NIST-traceable), Custom Test Chamber Kits, Method Validation Support Services |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | MFT-900 |
| Detection Principle | Vacuum Decay / Differential Pressure Method |
| Compliance | USP <1207>, ASTM F2338-22, FDA Guidance on Container Closure Integrity Testing (CCIT) |
| Automation Level | Semi-Automatic |
| Detection Sensitivity | Equivalent to ≥2 µm defect aperture |
| Pressure Range | −0.1 to 1.0 MPa (selectable ranges: −0.1–0.2 MPa / −0.1–0.7 MPa / −0.1–1.0 MPa) |
| Differential Pressure Sensor | ±2 kPa, Accuracy ≤0.5% FS, Resolution: 0.1 Pa |
| Test Pressure Sensor Accuracy | ≤±1% FS |
| Display | 10-inch color capacitive touchscreen |
| Data Storage | ≥5 years audit-trail-enabled event logs & test records |
| User Management | 4-tier role-based access control (RBAC), password-authenticated login |
| Regulatory Support | Full 21 CFR Part 11 compliance (electronic signatures, audit trail, data integrity) |
| Interface Options | Ethernet, USB, RS485, 4–20 mA analog output, 12 V alarm signal |
| Power Supply | AC 100–240 V, 50/60 Hz, ≤200 W |
| Data Export | USB flash drive backup |
| Optional Peripherals | External thermal printer |
| Brand | Neuronbc |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NBC-1002 |
| Price | USD 28,000 (FOB Beijing) |
| Excitation Wavelength | 785 nm |
| Laser Power | ≤500 mW (adjustable) |
| Spectral Range | 200–3200 cm⁻¹ |
| Spectral Resolution | ≤8 cm⁻¹ |
| Detector | TE-cooled CCD |
| Battery Life | ≥6 hours (continuous operation) |
| Connectivity | Wi-Fi 5 (802.11ac), Bluetooth 5.0, USB-C |
| Data Storage | Internal 64 GB + cloud-sync capable |
| Compliance | Meets ISO/IEC 17025 calibration traceability requirements |
| Brand | NeuronBC |
|---|---|
| Model | NBTB |
| Material | Sintered Titanium Powder |
| Filtration Accuracy | 1–50 µm (standard options: 1, 2, 3, 5, 10, 15, 30, 50 µm) |
| Porosity | 35–45% |
| Air Permeability Coefficient | 5×10⁻⁷ – 1×10⁻⁴ L/cm²·min·Pa |
| Minimum Burst Strength | ≥4 MPa |
| End Cap Configurations | Threaded, 222, 226, Flat-Plate |
| Outer Diameter | 30–80 mm |
| Length | 5", 10", 20", 30", 40" |
| Origin | Beijing, China |
| Regulatory Compliance | Designed for USP <788>, ISO 4074, and GMP-compliant bioprocessing environments |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | NEH-10 |
| Price | USD 495 (FOB Beijing) |
| Brand | NeuronBC |
|---|---|
| Model | NL |
| Filter Material | Nylon 6 / Nylon 66 |
| Pore Sizes | 0.1 µm, 0.22 µm, 0.45 µm, 0.65 µm, 0.8 µm, 1.2 µm |
| Filtration Area | 0.60 m² |
| Bubble Point (0.22 µm) | ≥ 0.28 MPa |
| Bubble Point (0.45 µm) | ≥ 0.18 MPa |
| Max Operating Pressure (Forward) | 0.42 MPa @ 25°C |
| Max Service Temperature | ≤ 65°C @ 0.21 MPa |
| Steam Sterilization | 121°C, 0.1 MPa, 30 min per cycle (up to 30 cycles) |
| Delta-P Replacement Threshold | 0.20 MPa |
| Housing & Endcaps | Polypropylene (PP) |
| Core Support | 304 or 316 Stainless Steel |
| Internal Support Layer | Imported Polyester Nonwoven |
| Seal Materials | Silicone or Fluoroelastomer (FKM) |
| Pure Water Flow Rate (ΔP = 0.01 MPa) | 3.3 L/min (0.22 µm), 5.1 L/min (0.45 µm) |
| Bacterial Retention | ≥ 10⁷ CFU/cm² |
| Integrity Test Method | Forward Flow / Bubble Point |
| Compliance | GMP-compliant manufacturing, pre-sterilized options available, fully traceable lot documentation |
| Brand | NeuronBC |
|---|---|
| Model | NSTS-1000 |
| Origin | Beijing, China |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 120 W |
| Pump Speed Range | 20–300 rpm |
| Height of Suspension Assembly | 45 cm |
| Net Weight | 18 kg |
| Construction Material | Electropolished Stainless Steel (316L-grade compatible) |
| Motor Type | Brushless DC Motor with Continuous Speed Control |
| Display | High-Resolution Color Touchscreen Interface |
| Safety Protections | Overcurrent, Overvoltage, Overload, Stall Detection, Adjustable Pressure-Limit Protection |
| Tubing Clamping | One-Touch Linear Pump Head with Quick-Release Cap |
| Compliance | Designed to support USP <71>, EP 2.6.1, and ISO 11737-1 workflows |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | PTFE |
| Filtration Rating (Liquid) | 0.22 µm & 0.45 µm |
| Filtration Rating (Gas) | 0.01 µm |
| Bubble Point | ≥ 0.08 MPa (95% IPA) |
| Diffusion Flow | ≤ 5.5 mL/min (60:40 IPA:Water at 0.064 MPa) |
| Gas Flow Rate (Hydrophobic, 0.01 µm) | ≥ 6 m³/min (ΔP = 0.015 MPa at 0.13 MPa inlet) |
| Water Flow Rate (Hydrophilic, 0.22 µm) | ≥ 6.89 L/min (ΔP = 0.01 MPa at 0.13 MPa inlet) |
| Max Operating Pressure (Forward) | 0.42 MPa @ 25°C |
| Max Reverse Pressure | 0.21 MPa @ 25°C |
| Max Service Temperature | 65°C @ 0.21 MPa (Standard), 95°C @ 0.1 MPa (High-Temp Grade) |
| Sterilization | 142°C @ 0.276 MPa (Autoclave) |
| Online Steam | 135°C @ 0.1 MPa, 30 min per cycle (up to 160 cycles) |
| Max ΔP for Replacement | 0.20 MPa |
| Housing Material | Polypropylene (PP) |
| Core Support | PP, 304 SS, or 316 SS |
| End Cap & Connector | PP |
| Support Layer | Imported Polyester Nonwoven |
| Seal Materials | Food-Grade EPDM, Silicone, or FKM |
| Effective Filtration Area | 0.70 m² (10-inch format) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | PTFE-NWF |
| Filtration Rating | 0.2 µm (liquid), <0.01 µm (gas), <0.003 µm (dual-layer) |
| Max Operating Temperature | 90 °C @ 0.20 MPa |
| Sterilization | 121 °C, 30 min (≥50 cycles) |
| Forward Pressure Rating | 0.42 MPa @ 25 °C |
| Reverse Pressure Rating | 0.21 MPa @ 25 °C |
| Endotoxin Level | <0.25 EU/mL |
| Extractables | <10 mg per 10-inch cartridge (Φ69 mm) |
| Chemical Resistance | Broad compatibility with acids, bases, and organic solvents |
| Brand | NeuronBC |
|---|---|
| Model | PVDF |
| Filter Material | Polyvinylidene Fluoride (PVDF) Microporous Membrane |
| Filtration Area (10″) | 0.60 m² |
| Liquid Sterile Filtration Rating | 0.22 µm |
| Gas Filtration Rating | 0.01 µm |
| Bubble Point (Isopropanol, 0.22 µm) | ≥ 0.065 MPa |
| Air Flow Rate | ≥ 6 m³/min at ΔP = 0.015 MPa (inlet pressure 0.13 MPa) |
| Forward Pressure Drop | 0.42 MPa at 25 °C |
| Reverse Pressure Drop | 0.21 MPa at 25 °C |
| Operating Temperature | ≤ 65 °C (standard), ≤ 95 °C (high-temp grade, 0.1 MPa) |
| Steam Sterilization | 121 °C, 0.1 MPa, 30 min per cycle (validated for ≥ 100 cycles) |
| Housing & Endcap Material | Polypropylene (PP) or PVDF |
| Core Support | Imported Polyester Nonwoven |
| Seal Material | Silicone or FKM (Fluoroelastomer) |
| Chemical Compatibility | Broad resistance to strong acids, aliphatic/aromatic hydrocarbons, ketones, ethers, and halogenated solvents |
| Brand | Neuronbc |
|---|---|
| Origin | Beijing, China |
| Model | RIT-1000 |
| Compliance | FDA 21 CFR Part 11, EU Annex 11, GAMP 5 |
| Test Principle | Pressure Decay Method |
| Port Compatibility | Universal RTP interface (ISO 14644-3 compliant flange dimensions) |
| Sensitivity | ≤0.1 Pa/s pressure decay detection threshold |
| Operating Environment | ISO Class C/D cleanrooms |
| Form Factor | Portable benchtop unit with integrated pressure sensor and vacuum pump |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 |
| Instrument Type | Benchtop Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation (254 nm) |
| Measurement Range | 0.001–1.0 mg/L (1–1000 ppb) |
| Accuracy | ±3% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% RSD |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Sample Temperature Range | 1–99 °C |
| Audit Trail | 16-event log with timestamped entries |
| User Access Control | 4-tier role-based authentication |
| Data Export | USB flash drive support |
| Data Storage Capacity | >5000 test records |
| Display | Color capacitive touchscreen |
| Compliance | Meets Chinese Pharmacopoeia 2020 Edition (ChP) General Chapter <0682>, FDA 21 CFR Part 11 (electronic records & signatures), and GLP/GMP-aligned validation protocols (IQ/OQ/PQ support available) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photocatalytic Oxidation (with TiO₂-coated quartz tube) |
| Measurement Range | 0.001–1.0 mg/L (1–1000 ppb) |
| Accuracy | ±3% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Sample Temperature Range | 1–99 °C |
| Data Storage | >5000 records |
| Audit Trail | 16-event log with timestamped traceability |
| User Access Control | 4-tier role-based authentication compliant with FDA 21 CFR Part 11 |
| Display | Color touchscreen interface |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photocatalytic Oxidation |
| Measurement Range | 0.001–1.0 mg/L (1–1000 ppb) |
| Accuracy | ±3% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Sample Temperature Range | 1–99 °C |
| Data Logging | 5000+ records |
| Audit Trail | 16-event log with timestamped entries |
| User Access Control | 4-tier password authentication compliant with FDA 21 CFR Part 11 |
| Display | Color touchscreen |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 OL Offline |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity |
| Oxidation Method | UV Photocatalytic Oxidation |
| Measurement Range | 1–1000 ppb C |
| Accuracy | ±3% of reading |
| Detection Limit | 1 ppb C |
| Resolution | 1 ppb C (full range) |
| Repeatability | ±3% RSD |
| Compliance | Designed to meet Chinese Pharmacopoeia 2020 Edition (ChP), USP <643>, and EP 2.2.44 requirements for offline water quality testing |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 Offline |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation (TiO₂-coated Quartz Tube) |
| Measurement Range | 1–1000 ppb (0.001–1.0 mg/L) |
| Accuracy | ±3% of reading |
| Resolution | 1 ppb (0.001 mg/L) |
| Detection Limit | 1 ppb (0.001 mg/L) |
| Repeatability | ≤3% RSD |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Sample Temp. Range | 1–99 °C |
| Data Storage | >5000 records |
| Audit Trail | 16-event log with timestamped traceability |
| User Access Control | 4-tier role-based authentication compliant with FDA 21 CFR Part 11 |
| Display | Color TFT touchscreen |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0/TOC |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 1–1000 ppb (as C) |
| Accuracy | ±3% of reading |
| Detection Limit | 1 ppb (as C) |
| Resolution | 1 ppb (as C) |
| Repeatability | ±3% RSD |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | ≤5 min per sample |
| Power Supply | 220 V AC |
| Display | Color TFT Touchscreen |
| Data Storage | Internal memory for ≥10,000 test records |
| Compliance | Meets Chinese Pharmacopoeia 2020 Edition (ChP) Chapter 0682 requirements for purified water and WFI |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 1–1000 µg/L (ppb) |
| Accuracy | ±3% of reading |
| Detection Limit | 1 µg/L |
| Resolution | 1 µg/L |
| Repeatability | ≤3% RSD |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | <5 minutes per sample |
| Display | Color TFT Touchscreen |
| Power Supply | 220 V AC |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.1 |
| Instrument Type | Benchtop Offline TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photocatalytic Oxidation (185/254 nm) |
| Measurement Range | 1–1000 ppb (0.001–1.0 mg/L) |
| Accuracy | ±3% of reading |
| Detection Limit | 1 ppb (0.001 mg/L) |
| Repeatability | ≤3% RSD |
| Resolution | 0.001 mg/L |
| Analysis Time | <5 minutes per sample |
| Sample Temperature Range | 1–99 °C |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Data Logging | ≥5000 records with time-stamped audit trail (16 event categories) |
| User Access Control | 4-tier password-protected authentication |
| Compliance | Designed to support FDA 21 CFR Part 11, USP <643>, EP 2.2.44, and ChP 2020 Edition General Chapter 0682 requirements |