Optronic Laboratories
Filter
Showing all 27 results
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Price Range | USD 0 – 7,200 (est.) |
| Sphere Diameter | 2 m |
| Spectral Range | 400–1100 nm |
| Coating Reflectance | >98% (400–1100 nm) |
| Compliance | IES LM-79, CIE 127, LM-80 ready |
| Safety Features | Interlocked optical sensors, industrial-grade slip-clutch drive, safety foot pads |
| Cooling | Dual thermal fans + real-time temperature monitoring |
| Mounting Options | Suspension or upward support |
| Auxiliary Lamp | Integrated for self-absorption correction |
| Compatible Spectrometer | OL 770 series |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Model | OL-200 / OL-220 / OL-245 |
| Power Ratings | 1000 W / 200 W / 45 W |
| Spectral Range | 250–4500 nm |
| Calibration Uncertainty | ±0.5% (high-accuracy option) or ±1.0–1.5% (standard option) |
| Calibration Traceability | NIST via OL-750D double monochromator wavelength-by-wavelength transfer |
| Available Spectral Modes | UV-VIS (250–750 nm), NIR (750–2500 nm), Extended NIR (250–2500 nm), Full IR (250–4500 nm), VIS-only (380–780 nm), Photometric (luminous flux, V(λ)-weighted), Color Temperature (CCT), and Uncalibrated (seasoned) variants |
| Mounting Options | Adjustable calibration stand and fixed-mount fixture included |
| Compliance | Fully compatible with ASTM E308, ISO/CIE 11664, CIE S 014, USP <857>, and GLP/GMP traceability requirements for radiometric validation |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Model | OL 440-8 |
| Spectral Range | 200–400 nm |
| Configuration | Source Head + OL 46D Controller + Power Supply |
| Calibration Traceability | NIST-traceable |
| Optional | Uncertified Source Only |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OL 455 |
| Pricing | Upon Request |
| Sphere Diameters Available | 6", 8", 12", 18" |
| Light Source | 150 W Quartz Halogen Tungsten Lamp with Ellipsoidal Reflector |
| Brightness Control | Manual (OL 455-XA) or Motorized Aperture (OL 455-XSA) |
| Spectral Options | Standard Illuminants A, B, C, D65 via Interchangeable Bandpass Filters |
| Color Temperature Stability | Maintained Across Full Brightness Range |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OL 458-4 |
| Pricing | Upon Request |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | OL 46D |
| Pricing | Available Upon Request |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OL 480 |
| Pricing | Upon Request |
| Emissivity | 0.99 ± 0.01 |
| Temperature Range | 100–1200 °C |
| Temperature Uncertainty | ±2 °C (NIST-traceable PtRh thermocouple) |
| Aperture Wheel | 8-position, diameters: 0.4, 0.6, 1.2, 2.5, 5.1, 10.2, 15.2, 25.4 mm |
| Temperature Stability | ±0.05% of full scale (via microprocessor-based digital PID controller) |
| Optional Coupling | Compatible with O740-4P off-axis parabolic collimator for collimated IR beam generation |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Model | OL FEL |
| Spectral Range | 250–4500 nm |
| Nominal Total Irradiance | 32 mW/cm² |
| Nominal Illuminance | 800 fc |
| Transfer Uncertainty (vs. NIST) | ±1.0% (High-Accuracy), ±0.5% (Super High-Accuracy) |
| Operating Current | 8.00 A DC |
| Long-Term Stability | <0.06%/hour (standard) |
| Calibration Method | Wavelength-by-wavelength radiometric transfer from NIST primary standard lamps using OL750D double monochromator system |
| Mounting | NIST-traceable 6-axis adjustable mount with crosshair target alignment accessory |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OL Series |
| Calibration Traceability | NIST-traceable via OL 750D Double Monochromator |
| Pricing | Available Upon Request |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Model | OL UV-40 |
| Calibration Traceability | NIST |
| Spectral Range | 200–400 nm |
| Calibration Interval | 10 nm |
| Uncertainty | ±3–5% (250–400 nm), ±10% (200–250 nm) |
| Operating Current | 300 mA DC |
| Pre-Aging Duration | 24 h |
| Irradiance Stability | ±2% over 50 h |
| Calibration Area Diameter | ~0.3 mm |
| Typical Spectral Irradiance at 250 nm | ~5× that of a 1000 W tungsten standard |
| Optional Radiance Calibration | e.g., 12 W/(m²·nm·sr) at 250 nm |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Model | OL 426-S / OL 426-SA |
| Configuration | Dual-integrating-sphere optical head + standalone OL 400-CS controller (precision power supply & real-time luminance monitoring) |
| Sphere diameters available | 6", 8", 12", 18" |
| Output port diameters | 1.5", 2", 3", 6" |
| Luminance dynamic range | 10⁶ (with stable CCT maintenance) |
| Control mode | Manual (OL 426-S) or motorized, programmable (OL 426-SA) |
| Calibration traceability | NIST-traceable spectral radiance and luminance standards |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | OL459 |
| Pricing | Available Upon Request |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Model | OL770NVS |
| Spectral Range | 380–930 nm (standard), optional 380–1100 nm (NIR) |
| Luminance Range | 2×10⁻⁴ to 1500 cd/m² |
| Luminance Accuracy | <1% |
| Chromaticity Accuracy (u′v′) | <0.0003 |
| Chromaticity Repeatability | ±0.00015 (x), ±0.0002 (y) |
| Wavelength Accuracy | ±0.5 nm |
| Optical Bandwidth (FWHM) | 10 nm |
| Radiance Sensitivity | 1.0×10⁻¹² W·sr⁻¹·m⁻²·nm⁻¹ |
| Stray Light Level | <2.5×10⁻⁴ |
| Zero Drift | <0.01% |
| Integration Time | 0.02–60 s |
| Slit Width | 350 µm |
| Fiber Coupling | SMA 905, 600-µm core silica fiber, stainless steel jacket, standard length 1.5 m (2.0 m / 3.0 m optional) |
| Detector | Thermoelectrically Cooled CCD Array |
| Grating | Aberration-Corrected Concave Flat-Field |
| Compliance | MIL-STD-3009, MIL-L-85762A, NVIS Class A & B (Ga/Gb) Weighting |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | OL 100 |
| Trigger Mode | Steady-State |
| Total Irradiance (Nominal) | 136 mW/cm² |
| Irradiance at 1000 nm | 100 µW/cm²·nm |
| Luminous Exitance (Nominal) | 3 lm/cm² (3000 fc) |
| Long-Term Stability | 0.06% / hour |
| Spectral Irradiance Uncertainty | ±1–2% |
| Total Irradiance Uncertainty | ±1.5% |
| Luminous Exitance Uncertainty | ±1.5% |
| Effective Radiating Area | 3 cm × 5 cm |
| Uniformity (Central Region) | ±0.25% |
| Spectral Calibration Options | OL-100A (300–750 nm), OL-100B (750–2500 nm), OL-100C (300–2500 nm), OL-100P (Photometric), OL-100U (Uncalibrated, Seasoned) |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | OL 345 |
| Pricing | Upon Request |
| Spectral Irradiance @ 650 nm | 0.6 DW/cm²·nm (typical) |
| Spectral Radiance @ 650 nm | 0.45 DW/sr·cm²·nm (typical) |
| Illuminance @ 6.500 A | 24 fc (typical) |
| Luminance @ 6.500 A | 65 fL (typical) |
| Radiometric Accuracy | ±2% @ 650 nm, ±4% @ 250 nm |
| Photometric Accuracy | ±1% |
| Stability | ≤±1% drift over 50 hours |
| Lamp Power | 45 W (6.500 A) |
| Diameter | 5 inches |
| Spectral Range (Irradiance Mode) | 250–2500 nm |
| Spectral Range (Radiance/Luminance Mode) | 350–1100 nm |
| Uniform Area (with opal diffuser) | 15.5 cm² |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | OL 410 |
| Power Ratings | 150 W (OL 410-150), 200 W (OL 410-200), 1000 W (OL 410-1000) |
| Current Accuracy | ±0.02% of reading |
| Current Resolution | 0.001 A |
| Short-Term Stability | ≤10 ppm |
| Temperature Coefficient | ≤25 ppm/°C |
| Ramp Control | Programmable current rise/fall profiles |
| Lamp Memory | 10 independent lamp profiles with calibration metadata and elapsed-time tracking |
| Calibration Mode | Three-point low-current correction |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Model | OL 752-10 / OL 752-12 |
| Spectral Range (OL 752-10) | 250–2500 nm |
| Spectral Range (OL 752-12) | UV-dominated, optimized for 200–400 nm |
| Lamp Type | Tungsten-halogen (OL 752-10), Deuterium (OL 752-12) |
| Mounting | Integrated, factory-aligned collimated output with protective shutter cap |
| Compliance | NIST-traceable calibration certificates supplied per unit |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OL 756 |
| Pricing | Available Upon Request |
| Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±0.15 nm |
| Wavelength Resolution | 0.025 nm |
| Wavelength Repeatability | ±0.05 nm |
| Optical Half Bandwidth (FWHM) | 0.4–10 nm |
| Stray Light Level | <10⁻⁸ @ 285 nm (typ.) |
| Spectroradiometric Accuracy (k=2) | 1% (UVA–Vis), 3% (UVB–UVC) |
| Measurement Modes | Manual, Normal, Quickscan |
| Max Scan Speed | 200 nm/sec (Quickscan) |
| Noise Equivalent Irradiance | 1.7×10⁻⁷ W/m²·nm @ 300 nm, 1.0×10⁻⁷ W/m²·nm @ 500 nm, 5.6×10⁻⁷ W/m²·nm @ 700 nm |
| Detector | TE-cooled S-20 response photomultiplier tube (PMT) |
| High Voltage Range | 0–1100 V |
| Interface | USB / RS-232 |
| Operating Temperature | 10–40 °C |
| Power | 12 VDC / 3 A max, or 115 VAC / 1.2 A, or 230 VAC / 0.6 A |
| Dimensions | 12.75″ × 11″ × 8.75″ |
| Weight | 25 lbs |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Model | OL-3m |
| Sphere Diameter | 3 meters (customizable from 0.5 m to 3 m) |
| Coating Options | PTFE (for small spheres), Optolon 2 (standard for mid-to-large spheres), Avian-D (domestic housing + imported coating variant) |
| Mounting | Motorized lid actuation available for spheres ≥2 m |
| Compliance | Designed to meet ASTM E1337, CIE S 025/E:2015, and ISO/CIE 19476:2014 requirements for photometric calibration and luminous flux measurement |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Model | OL750 |
| Spectrometer Type | Dual-grating monochromator |
| Wavelength Range | 200 nm – 30 µm |
| Spectral Resolution | 0.25 nm – 10 nm (adjustable) |
| Dispersion | 2 nm/mm |
| F/# | F/4 |
| Wavelength Accuracy | ±0.01% of reading |
| Stray Light | ≤10⁻⁸ |
| Optical Configuration | Modular scanning monochromator system |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | OL750 / OL756 |
| Price Range | USD 110,000 – 138,000 |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | OL750D |
| Price Range | USD 110,000 – 135,000 |
| Grating Spectral Range | 200 nm – 30 µm |
| Wavelength Accuracy | ±0.05% |
| Wavelength Repeatability | ±0.01% |
| Reciprocal Linear Dispersion | 2 nm/mm |
| Bandwidth (FWHM) | 0.25–10 nm |
| Stray Light Level | ≤1×10⁻⁸ |
| Grating Size | 68 mm × 68 mm |
| Focal Length | 254 mm (f/4) |
| Chopper Frequency Range | 10–500 Hz |
| Control Interface | RS-422 |
| Nonlinearity Error | <0.1% |
| Silicon Detector (Spectral Range | 200–1100 nm |
| Lead Sulfide (PbS) Detector (Spectral Range | 1000–3200 nm |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Model | OL756 |
| Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±0.15 nm |
| Wavelength Resolution | 0.025 nm |
| Wavelength Repeatability | ±0.05 nm |
| FWHM | 0.4–10 nm |
| Stray Light | <1×10⁻⁸ @ 285 nm (typ.) |
| Dynamic Range | 10⁷ |
| Spectral Radiance Accuracy | ±1% (UVA–Vis), ±3% (UVB–UVC) |
| Scan Speed | 200 nm/s |
| Radiometric Noise (Irradiance Equivalent) | 1.7×10⁻⁷ W·m⁻²·nm⁻¹ @ 300 nm, 1×10⁻⁷ W·m⁻²·nm⁻¹ @ 500 nm |
| Power Supply | 12 VDC |
| Portability | Sum of L+W+H ≤ 85 cm |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | OL770 |
| Pricing | Upon Request |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OL770 |
| Pricing | Available Upon Request |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Optolon 2A / Avian-D / Avian-B |
| Price Range | USD $0–7,000 (varies by coating type, surface area, and application support) |
| Brand | Optronic Laboratories |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Optical Instrument Component |
| Model | UIS Series Integrating Sphere |
| Component Type | Custom-Configurable Integrating Sphere |
| Coating Options | Spectralon® (UV–VIS–NIR), Gold-Coated (MIR–FIR), Water-Washable PTFE-Based Coatings |
| Diameter Range | 25 mm (1″) to 2032 mm (80″), including standard sizes from 102 mm (4″) to 1930 mm (76″) |
| Configuration Flexibility | Adjustable port count, port geometry (collimated, fiber-coupled, baffle-integrated), internal baffle positioning, and coating selection per spectral band |
| Measurement Modes | 4π (total flux), 2π (hemispherical), and directional reflectance/transmittance |
| Compliance | NIST-traceable calibration support available |