Pri-eco
Filter
Showing 1–30 of 86 results
| Brand | PRI-ECO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | G-Flask |
| Pricing | Available Upon Request |
| Brand | Pri-eco |
|---|---|
| Origin | France |
| Manufacturer | Hprobe SAS (distributed by Pri-eco) |
| Category | Import |
| Model | Speed-Up Wafer-level Magnetic Test |
| Pricing | Upon Request |
| (brand | Pri-eco |
|---|---|
| origin | Beijing, China |
| manufacturer | Pri-eco |
| type | benchtop isotope ratio mass spectrometer |
| model | Isotope5 CNS |
| measurement range | δ¹³C, δ¹⁵N, δ³⁴S, δ³²S |
| resolution | >75 at m/z 29) |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PRI-2012 |
| Pricing | Available Upon Request |
| Chamber Type | Dark (Aluminum) / Transparent (Acrylic) |
| External Dimensions | 44 × 26 × 26 cm (L×W×H) |
| Chamber Internal Diameter | 20 cm |
| Chamber Height | 13 cm (adjustable |
| Measurement Volume | 4500 cm³ (customizable) |
| Measurement Area | 350 cm² (customizable) |
| Operating Principle | Dynamic Pressure-Balanced Flow-Through Method |
| Actuation | Stepper Motor |
| Control Unit | Embedded Microcontroller |
| Interface | Aviation Connector (MIL-DTL-5015 compliant) |
| Weight | ~5.0 kg (including handle) |
| Environmental Rating | IP65-equivalent (curved housing, dust- and water-resistant design) |
| Remote Operation | Bluetooth/WiFi-enabled mobile app (iOS/Android) |
| Brand | Pri-eco |
|---|---|
| Model | PRI-8300 Plus |
| Origin | Beijing, China |
| Manufacturer | Pri-eco |
| Power Consumption | 100 W |
| Input Voltage | 110–220 VAC, 50–60 Hz |
| Dimensions (H×W×D) | 43.2 × 17.8 × 44.5 cm |
| Weight | 18 kg |
| Gas Analytes | CO₂, CH₄, N₂O, H₂O |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) coupled with hydrophobic gas-permeable membrane diffusion |
| Sampling Method | Multi-depth closed-loop diffusion profiling |
| Standard Depth Channels | 6 (configurable) |
| Membrane Material | Polypropylene |
| Membrane Wall Thickness | 1.55 mm |
| Inner Diameter | 5.5 mm |
| Burst Pressure | ≥116 psi |
| Intraluminal Burst Pressure | ≥36 psi |
| Permeation Rate | 1.4 mL/(min·cm²·bar) @ 23°C (isopropanol) |
| Saturation Pressure | 15.5 psi @ 23°C (isopropanol) |
| Sampling Temperature Range | −10 to +45 °C (extendable to −30 °C) |
| Sample Flow Rate | 0.050 L/min at 760 Torr |
| Operating Pressure Range | 700–1000 Torr (40–133 kPa) |
| CO₂ Range | 0–10% vol |
| CH₄ Range | 0–1% vol |
| N₂O Range | 0–500 ppmv |
| H₂O Range | 0–7% vol |
| CO₂ Precision (1 s) | ±0.2 ppmv |
| CH₄ Precision (1 s) | ±1 ppbv |
| N₂O Precision (1 s) | ±0.2 ppbv |
| H₂O Precision (1 s) | ±50 ppmv |
| CO₂ Precision (5 min) | ±0.04 ppmv |
| CH₄ Precision (5 min) | ±0.2 ppbv |
| N₂O Precision (5 min) | ±0.03 ppbv |
| H₂O Precision (5 min) | ±10 ppmv |
| Calibration Options | 3-channel automated calibration module (optional, customizable) |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Pri-eco |
| Country of Origin | Domestic (China) |
| Model | PRI-8400 |
| Price | Upon Request |
| Brand | Pri-eco |
|---|---|
| Model | AirPlus |
| Detection Principle | Mid-Infrared Laser Absorption Spectroscopy (MIRLAS) |
| Measured Gases | CO₂, N₂O, H₂O |
| CO₂ Range | 0–3500 ppm |
| N₂O Range | 0–500 ppb |
| H₂O Range | 0–3% |
| Precision (1s) | 0.25 ppm CO₂, 0.25 ppb N₂O, 50 ppm H₂O |
| Precision (5s) | 0.12 ppm CO₂, 0.12 ppb N₂O, 40 ppm H₂O |
| Precision (5 min) | 0.012 ppm CO₂, 0.012 ppb N₂O, 10 ppm H₂O |
| Sample Flow Rate | ~180 mL/min (optional 1000 mL/min pump) |
| Operating Temperature | −10 to +45 °C |
| Relative Humidity Limit | <99% RH, non-condensing |
| Power Consumption | 15 W (steady-state) |
| Dimensions | 29 cm × 20 cm × 9.5 cm |
| Weight | 2.75 kg |
| Response Rate | 1 or 2 Hz |
| Data Interfaces | Wi-Fi, USB, RS-232 |
| Optional Outputs | Analog (4–20 mA), GPS module |
| Battery Life | 6 hours (internal Li-ion) |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AirScan 2000 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) coupled with Single-Photon Avalanche Diode (SPAD) detection and 3D scanning lidar architecture |
| Detection Scope | OGMP 2.0 Tier 4 & Tier 5 compliant site-level continuous monitoring and component-level leak localization |
| Measurement Range | 360° panoramic field-of-regard, up to 200 m detection distance |
| Limit of Detection | ≥90% Probability of Detection (PoD) under representative atmospheric conditions |
| Quantification Accuracy | ±2× uncertainty (1-sigma) dependent on wind speed and direction |
| False Positive Rate | 0% when using factory-validated data processing algorithms and recommended client configuration |
| Laser Safety Class | Class 1M |
| Operating Temperature | –40 °C to +50 °C |
| IP Rating | IP67 |
| Dimensions | 43 × 18 × 18 cm |
| Weight | 8 kg (including pan-tilt mount) |
| Power Supply | 24 VDC, 30 W |
| Communication Interfaces | Ethernet, Wi-Fi, mobile API endpoint |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AMBA C123+N |
| Price | Upon Request |
| Measurement Principle | Mid-infrared quantum cascade laser absorption spectroscopy coupled with high-speed gas chromatography and micro-combustion |
| δ¹³C Precision (C₁–C₄) | <0.4‰ (1σ) |
| Sampling Frequency | 1 Hz |
| Cycle Time per Sample | ≤3 min (including C₁, C₂, C₃, and C₄ isotopic analysis) |
| Measurement Chamber Volume | <1 mL |
| Operating Pressure | 50 Torr |
| Concentration Range | CH₄ >0.5% v/v |
| Operating Temperature | 0–35 °C (above dew point) |
| Relative Humidity | <100% RH |
| Dimensions (Isotope Analyzer) | 740 × 465 × 357 mm (H) |
| Dimensions (Fast GC Module) | 675 × 558 × 370 mm (H) |
| Power Requirement | 110/220 V AC, 50/60 Hz |
| Peak Power | 3 kW |
| Average Power | 1 kW |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AMBA i3211 |
| Pricing | Available Upon Request |
| Measurement Principle | Mid-Infrared Hollow Waveguide Absorption Spectroscopy |
| Sample Chamber Volume | ~1 mL |
| δ¹³C Precision | <0.08‰ (1σ, 60 s) |
| CO₂ Concentration Range | 380–5000 ppm |
| Sampling Frequency | 4 Hz (high-speed mode), 1 Hz (standard mode) |
| Sample Flow Rate | 15 mL/min (standard), 5 mL/min (low-flow mode) |
| Sample Cell Volume | 0.1 mL |
| Operating Temperature | −10 to +45 °C |
| Vacuum Pump Capacity | 100 sccm at 50 Torr |
| Operating Pressure | 50–133 kPa |
| Relative Humidity Tolerance | <99% RH (non-condensing at ≤40 °C, no drying required) |
| Calibration | Fully Automated Online Calibration |
| Data Interfaces | RS-232, Ethernet, USB |
| Inlet/Outlet Fittings | 1/8″ Swagelok® Compression Ferrules |
| Dimensions (W×D×H) | 483 × 800 × 476 mm (19″ × 31.5″ × 18.75″) |
| Weight | 25 kg |
| Power Supply | 100–240 VAC, <350 W (startup), ~200 W (steady-state) |
| Brand | Pri-eco |
|---|---|
| Model | Canary |
| Type | Multi-parameter Soil Sensor Network System |
| Origin | Beijing, China |
| Manufacturer | Pri-eco |
| Power Supply | 6–15 VDC |
| Operating Temperature Range | −25 to +50 °C |
| Data Acquisition Channels | 8 per node |
| Sensor Compatibility | Canary-001 (moisture-only), Canary-002 (moisture + temp), Canary-003 (moisture + temp + EC) |
| Moisture Accuracy | ±3% vol (±<3% with site-specific calibration) |
| Temp Accuracy | ±0.4 °C |
| EC Accuracy | ±15% @ 0–1 S/m |
| Moisture Resolution | 0.1% vol |
| Temp Resolution | 0.1 °C |
| EC Resolution | 1 mS/m |
| Moisture Range | 0–70% vol |
| Temp Range | −55 to +120 °C |
| EC Range | 0.000–1 S/m |
| Probe | Dual 50 mm × 3 mm stainless steel rods |
| Housing | PVC tube, Ø20 mm |
| Cable Length | 1.5–10 m |
| RF Frequency | 70 MHz |
| Communication | Wireless (modular RF or LoRaWAN-ready) |
| Cloud Integration | Yes |
| Brand | Pri-ECO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | CC-50 |
| Chamber Dimensions | 50(L) × 50(W) × 40(H) cm |
| Net Weight | ~15 kg |
| Chamber Volume | 90.5 L (customizable) |
| Measurement Area | 0.1936 m² (customizable) |
| Optical Transmission | 93% (polycarbonate panel) |
| Light Control | Removable aluminized foil overlay for dark-adapted measurements |
| Window Actuation | Motorized linear actuators (top window: 90° rotation |
| side window | 45° rotation) |
| Sealing Mechanism | Precision pneumatic-assisted compression seal |
| Internal Mixing | Low-turbulence axial fan with adjustable RPM |
| Structural Material | Anodized aluminum frame + UV-stabilized optical-grade polycarbonate |
| Temperature Monitoring Range | –40 °C to +85 °C |
| Temp. Sensor Accuracy | ±2% FS |
| Power Supply | 12 V DC / 50 W nominal |
| Control Interface | Industrial-grade PLC + 7-inch resistive touchscreen HMI |
| Compliance | Designed for ISO 14064-3 field verification workflows and ASTM D6866–22 compatible δ¹³C flux partitioning protocols |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CRS-2000C |
| Price | Upon Request |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | CRS-2000S |
| Pricing | Upon Request |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | DMS-600 |
| Temperature Accuracy | ±0.3 °C |
| Relative Humidity Accuracy | ±3 % RH |
| Operating Temperature Range | −40 °C to +80 °C |
| Spectral Channels | 18 |
| Center Wavelengths (nm) | 410, 435, 460, 485, 510, 535, 560, 585, 610, 645, 680, 705, 730, 760, 810, 860, 900, 940 |
| Bandwidth | 20 nm per channel |
| Field of View | 41° |
| Optical Sensor Type | Diffuse irradiance (cosine-corrected) |
| Number of Spectral Sensor Units | 3 |
| Power Supply | Rechargeable Li-polymer battery (5000 mAh) |
| Operating Current | 80 mA |
| Sleep Current | 180 μA |
| Weight | 600 g |
| Data Transmission | NB-IoT |
| Remote Access | Web-based cloud platform and dedicated mobile application |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | EA-HWG |
| Price | Upon Request |
| δ¹³C Precision (1σ) | <0.1–0.2 ‰ |
| CO₂ Measurement Range | 380–10,000 ppmv |
| Measurement Frequency | 4 Hz |
| Sample Flow Rate | 0.5 mL/s |
| Measurement Cell Volume | <1 mL |
| Operating Temperature | −10 to 45 °C |
| Miniature Vacuum Pump | 100 sccm @ 50 Torr |
| Sampling Pressure | 50–133 kPa |
| Carrier Gas | Ultra-High-Purity N₂ or He |
| Combustion Gas | Ultra-High-Purity O₂ |
| Relative Humidity Tolerance | <99% RH (non-condensing at 40 °C) |
| Calibration | Fully Automated Online Calibration |
| Interface Options | RS-232, Ethernet, USB |
| Inlet/Outlet Fittings | 1/8″ Swagelok |
| Dimensions (CO₂ Analyzer) | 483 × 800 × 476 mm (W×D×H) |
| Weight | 25 kg |
| Dimensions (Elemental Analyzer) | 813 × 394 × 508 mm |
| Weight | 68 kg |
| Power Requirement | 100–240 VAC |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | EA-IRMS-SCAR |
| Pricing | Upon Request |
| 14C Measurement Precision | 1–1.5 pMC @ 10 min |
| Measured Isotopes | ¹³C, ¹⁴C, ¹⁵N |
| Resolution (Central Collector) | 80 |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | EA-MIR |
| Pricing | Upon Request |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | EA-SCAR 14CO₂ |
| Quotation | Upon Request |
| Measurement Precision | 1–1.5 pMC @ 10 min |
| Isotope Measured | ¹⁴C in CO₂ |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | Element5 610 |
| Detection Elements | C, H, N, S, O |
| Principle | Dumas Flash Combustion + Gas Chromatographic Separation |
| Furnace Configuration | Dual-Furnace (Oxidation + Reduction) |
| Detector | Self-Calibrating TCD |
| Sample Mass Range | 0.01–100 mg |
| Detection Range | 200 ppm – 100% |
| Accuracy | < 0.2% (vs. certified reference materials) |
| Precision | < 0.1% RSD (vs. certified reference materials) |
| LOD/LOQ | 1–5 µg |
| Oxidation Temp | 800–1100 °C |
| Reduction Temp | 600–1100 °C |
| Analysis Time (CHNS) | ~15 min |
| GC Column | 2 m packed column (CN separation) |
| Calibration Models | Linear, Quadratic, Cubic |
| Software | EAS CLARITY |
| Carrier Gas | Helium (99.999%, 3–5 bar) |
| Oxygen Supply | Ultra-High-Purity O₂ (99.999%, 3–5 bar) |
| Power | 230 VAC ±10%, 1–10 A |
| Dimensions (L×W×H) | 760 × 350 × 700 mm |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | Element5 624 |
| Detection Elements | C, H, N, S, O |
| Principle | Dumas flash combustion coupled with gas chromatographic separation |
| 炉 Design | Single-furnace (oxidation and reduction in one furnace) |
| Detector | TCD with auto-calibration |
| Sample Mass Range | 0.01–100 mg |
| Detection Range | 200 ppm – 100% |
| Accuracy | < 0.2% (vs. certified reference materials) |
| Precision | < 0.1% RSD (vs. certified reference materials) |
| LOD | 1–5 µg |
| Combustion/Reduction Temperature | 800–1100 °C |
| Analysis Time (CHNS) | ~15 min |
| GC Column Length | 2 m |
| Calibration Models | Linear, quadratic, cubic |
| Software | EAS CLARITY |
| Carrier Gas | Helium (99.999%, 3–5 bar) |
| Oxidant | Oxygen (99.999%, 3–5 bar) |
| Power Supply | 230 VAC ±10%, 1–10 A |
| Dimensions (L×W×H) | 760 × 350 × 700 mm |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | Element5 820 |
| Detection Elements | C, H, N, S, O |
| Sample Introduction | Pneumatic Auto-sampler (147 positions), Electric Auto-sampler (32/50/100 positions), Manual Sampler |
| Analysis Time | CN: 5 min |
| CHN | 8 min |
| CHNS | 10–25 min |
| O | 4 min |
| Measurement Range | C: 0.002–20 mg |
| H | 0.002–5 mg |
| N | 0.002–20 mg |
| S | 0.002–6 mg |
| O | 0.002–2 mg |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision | <0.1% (certified reference materials, purity >99.9%) |
| Furnace Configuration | Dual independent high-temperature furnaces (max. 1100 °C each) |
| Separation Oven Temp. | up to 110 °C |
| Carrier Gas | Ultra-high-purity helium (99.999%, 3–5 bar) |
| Oxidant Gas | Ultra-high-purity oxygen (99.999%, 3–5 bar) |
| Auxiliary Gas | Oil-free compressed air |
| GC Column | 0.8–4 m capillary separation column |
| Detector | High-sensitivity TCD with auto-calibration (no reference gas required) |
| Flow Control | Electronic mass flow regulation |
| Leak Detection | Fully automated self-diagnostic leak test |
| Oxygen Delivery | Intelligent, sample-mass-dependent dosing |
| Software | EAS Clarity (supports linear, quadratic, and cubic calibration models) |
| Sample Mass Range | 0.1–500 mg (up to 1000 mg for soil) |
| Sample Cups | High-purity tin or silver capsules |
| Dimensions | 810 × 500 × 370 mm |
| Weight | 68 kg |
| Power Supply | 230 V, 50/60 Hz |
| Max. Power Consumption | 1100 W, 5 A |
| Touchscreen Interface | Integrated industrial-grade display |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | Element5 822 |
| Detection Elements | C, N |
| Sample Forms | Solid and Liquid |
| Combustion Configuration | Dual-Furnace (Oxidation + Reduction) |
| Detection Principle | Dumas Flash Combustion Coupled with Gas Chromatographic Separation and Thermal Conductivity Detection (TCD) |
| Automation Features | Automated Leak Detection, Intelligent Oxygen Dosage Control, Electronic Flow Regulation, Self-Calibrating TCD |
| Sample Capacity | Up to 147 positions (Pneumatic Autosampler) |
| Analysis Time per CN Run | ~5 min |
| Measurement Range | C/N: 0.002–20 mg |
| Accuracy | <0.2% (Certified Reference Materials, Purity >99.9%) |
| Precision (RSD) | <0.1% (n ≥ 10, CRM) |
| Furnace Temp | Up to 1100 °C (Dual Independent Zones) |
| Separation Oven Temp | Up to 110 °C |
| Carrier Gas | Ultra-High-Purity Helium (99.999%, 3–5 bar) |
| Reactant Gas | Ultra-High-Purity Oxygen (99.999%, 3–5 bar) |
| Auxiliary Gas | Oil-Free Compressed Air |
| GC Column | 3 m Packed Capillary Column |
| Software | EAS Clarity v3.x (Compliant with FDA 21 CFR Part 11 Audit Trail & User Access Control) |
| Dimensions | 810 × 500 × 370 mm |
| Weight | 68 kg |
| Power Supply | 230 V, 50/60 Hz, 5 A, 1100 W |
| Sample Container | High-Purity Tin or Silver Cups |
| Optional Accessories | Analytical Balance Integration, Consumables Kits (Tubes, Cups, Reagents), Isotope Ratio Interface (IRMS-ready) |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Element5 824 |
| Detection Elements | C, N |
| Sample Form | Solid (soil), liquid |
| Combustion System | Dual-furnace Dumas flash combustion |
| Separation Method | GC column (3 m) |
| Detection | High-sensitivity TCD (reference-gas-free self-calibration) |
| Autosampler Options | Pneumatic (147-position), electric (32/50/100-position), manual |
| Analysis Time (C/N) | ≤5 min |
| Measurement Range | C/N: 0.002–20 mg |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision | <0.1% RSD (certified reference materials, purity >99.9%) |
| Furnace Temp | Up to 1100 °C (left & right), separation oven up to 110 °C |
| Carrier Gas | Ultra-high-purity He (99.999%, 3–5 bar) |
| Oxidant | Ultra-high-purity O₂ (99.999%, 3–5 bar) |
| Auxiliary Gas | Oil-free compressed air |
| Power Supply | 230 V, 50/60 Hz, 5 A, 1100 W |
| Dimensions | 810 × 500 × 370 mm |
| Weight | 68 kg |
| Software | EAS Clarity (linear, quadratic, cubic calibration |
| Compliance | Designed for GLP/GMP environments |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | Element5 840 |
| Detection Elements | C, H, N, S, O |
| Sample Introduction | Single-furnace Dumas combustion with catalytic reduction for oxygen |
| Measurement Principle | High-temperature flash combustion (Dumas method) coupled with gas chromatographic separation and thermal conductivity detection (TCD) |
| Automation Features | Auto leak detection, electronic flow control, intelligent O₂ dosing, self-calibrating TCD |
| Sample Capacity | 0.1–500 mg (up to 1000 mg for soil), solid/liquid |
| Analysis Time | C/N: 5 min |
| C/H/N | 8 min |
| C/H/N/S | 10–25 min |
| O | 4 min |
| Detection Range | C: 0.002–20 mg |
| H | 0.002–5 mg |
| N | 0.002–20 mg |
| S | 0.002–6 mg |
| O | 0.002–2 mg |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision | <0.1% RSD (same reference materials) |
| Furnace Temp | up to 1100 °C |
| Separation Oven | ≤110 °C |
| Carrier Gas | Ultra-high-purity He (99.999%, 3–5 bar) |
| GC Column | 0.8–4 m packed capillary column |
| Detector | High-sensitivity, reference-gas-free TCD |
| Software | EAS Clarity (supports linear, quadratic, cubic calibration |
| Dimensions | 510 × 500 × 370 mm |
| Weight | 53 kg |
| Power | 230 V, 50/60 Hz, 4 A, 900 W |
| Optional Accessories | Analytical balance, consumables (Sn/Ag capsules), isotope interface kit for IRMS coupling |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Element5 860 |
| Detection Principle | High-Temperature Catalytic Combustion (Dumas Method) with Gas Chromatographic Separation |
| Measured Elements | Total Nitrogen, Crude Protein (calculated) |
| Sample Forms | Solid and Liquid |
| Furnace Configuration | Dual-Furnace System (Oxidation + Reduction) |
| Carrier Gas | Ultra-High-Purity Helium (99.999%, 3–5 bar) |
| Reactant Gas | Ultra-High-Purity Oxygen (99.999%, 3–5 bar) |
| Detector | Self-Calibrating Thermal Conductivity Detector (TCD) |
| Automation Features | Auto-Leak Detection, Intelligent Oxygen Dosage Control, Electronic Flow Regulation, Auto-Flow Setup |
| Sample Capacity | Up to 147 positions (Pneumatic Autosampler) |
| Analysis Time per Sample | 4–8 min (N) |
| Nitrogen Measurement Range | 0.002–20 mg |
| Accuracy | <0.2% RSD (Certified Reference Materials, >99.9% purity) |
| Precision | <0.1% RSD (Same reference materials) |
| Furnace Temperature | Up to 1100 °C (each furnace) |
| Sample Mass Range | 0.1–400 mg |
| Power Supply | 230 V, 50/60 Hz, 5 A, 1100 W |
| Dimensions | 980 × 500 × 370 mm |
| Weight | 78 kg |
| Software | EAS Clarity (Compliant with FDA 21 CFR Part 11 Audit Trail & User Access Control) |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Element5 870 |
| Quotation | Upon Request |
| Principle | Adsorption/Desorption with Catalytic Oxidation & C-Quantum Selective Purification |
| Sample Type | Ambient Air |
| Output Purity | >99.99% CO₂ |
| Yield | 10–100 mg per run |
| Cycle Time | 10–60 min |
| Detection Compatibility | IRMS (δ¹³C), AMS or CRDS (¹⁴C) |
| Dual Combustion Furnaces | Left furnace max 500 °C, right furnace max 650 °C |
| Carrier Gas | Ultra-high-purity He (99.999%, 3–5 bar) |
| Auxiliary Gas | Ultra-high-purity CO₂ (99.999%, 3–5 bar) |
| Power Supply | 230 V, 50/60 Hz, 5 A, 1100 W |
| Dimensions | 800 × 500 × 370 mm |
| Weight | 50 kg |
| Display | Integrated Touchscreen Interface |
| Leak Detection | Automated Self-Test Routine |
| Operating Modes | Capture-only, Purification-only, Integrated Capture-Purification |
| Calibration | ISO Delta-compatible active calibration with electronic mass flow control |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ELF-600 |
| Detection Gases & Ranges | CO₂, N₂O, CH₄ (greenhouse gases), CO (combustion byproduct), H₂O (water vapor) |
| Max Takeoff Weight | 22.5 kg |
| Rotor Span (Diagonal) | 1.6 m |
| Max Speed | 45 km/h |
| Service Ceiling | 5000 m |
| Climb Rate | 5 m/s |
| Wind Resistance | Level 6 (Beaufort scale) |
| Control Link | 900 MHz RF |
| Navigation System | Dual-GNSS (GPS + BeiDou) |
| Endurance | 80 min (empty), 60 min (5 kg payload) |
| Control Radius | 20 km |
| Payload Options | Full-frame aerial survey camera (35 mm sensor, 42 MP), multispectral camera (VIS–NIR bands), GHG analyzer module, thermal imager, loudspeaker, spotlight, aerial payload dispenser |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | IPS-1000 |
| CO₂ Range | 0–3000 ppmv |
| δ¹³C Precision | <0.2 ‰ @ 1 s, 0.03 ‰ @ 60 s |
| δ¹⁸O Precision | <0.2 ‰ @ 1 s, 0.03 ‰ @ 60 s |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Isotope5 CN |
| Measurement Range | δ¹³C, δ¹⁵N |
| Resolution | >75 at m/z 29 |
| Detection System | Triple Faraday Collector for C/N/H/S/O |
| Mass Analyzer | 14 cm radius, 90° magnetic sector with permanent high-stability magnet |
| Vacuum System | Integrated low-power turbomolecular pump |
| Power Consumption | 240 W (typical) |
| Dimensions | 70 cm (L) × 30 cm (W) × 47 cm (H) |
| Weight | 45 kg |