SETARAM
Filter
Showing 1–30 of 61 results
| Brand | SETARAM |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China (Manufactured in Taiwan) |
| Model | SCF Series |
| Temperature Range | +5 °C to +35 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Capacity (at 20 °C) | 934–5740 W |
| Flow Rate | 14 L/min @ 3.5 kg/cm² (optional: 20 L/min @ 5.5 kg/cm²) |
| Reservoir Volume | 3.8 L |
| Dimensions (Reservoir) | 10 × 20 × 19 cm (W×D×H) |
| Overall Dimensions (SCF-25 to SCF-100) | 33×49×60 cm to 54×62×71 cm |
| Power Supply | 110/220 V, 50/60 Hz, 4–10 A |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | 96 Line |
| Temperature Range | RT to 1750 °C (upgradable to 2100 °C) |
| Heating Rate | 0–100 K/min |
| TG Sample Capacity | 100 g |
| Max. TG Sample Dimensions | Ø20 mm × H80 mm |
| TG Resolution | 0.3 µg |
| Calorimetric Sample Volume | 5700 µL (Ø14.5 mm × H35 mm) |
| Specific Heat Accuracy | ±1% (relative) |
| TMA Stroke Range | ±6 mm |
| TMA Resolution | 1.6 nm |
| TMA Max. Sample Dimensions | Ø18 mm × H50 mm |
| Sensor Architecture | 3D microcalorimetric sensor with Drop method implementation |
| Modular Configurations | TG, TG-DSC, TG-DTA, TMA, 3D calorimetry |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | 96line High-Temperature Specific Heat Analyzer |
| Temperature Range | Ambient to 2000 °C |
| Temperature Accuracy | ±0.5 °C (typical for high-temperature DSC-grade calibration) |
| Heating/Cooling Rate | 0.001–99 K/min |
| Sample Capacity (Calorimetry) | 5.7 mL (Ø14.5 mm × H35 mm) |
| Specific Heat Measurement Uncertainty | ≤1% (per ASTM E1269 & ISO 11357-4) |
| TGA Max Load | 100 g |
| TGA Resolution | 0.3 µg |
| TMA Range | ±6 mm |
| TMA Resolution | 1.6 nm |
| Modular Configurations | Simultaneous TG-DSC, TG-DTA, TMA, 3D Heat-Flow Calorimetry |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | 96line TMA |
| Instrument Type | Thermomechanical Analyzer |
| Temperature Range | Ambient to 2100 °C |
| Displacement Range | ±2 mm |
| Maximum Force | 1.5 N (electromagnetically controlled) |
| Sample Dimensions | L = 50 mm, Ø = 18 mm (recommended Ø = 15 mm) |
| Displacement Resolution | 1.6 nm RMS |
| Displacement Noise | 10 nm RMS |
| Specific Noise | 0.2 × 10⁻⁶ |
| Probe Types | Al₂O₃ (up to 1750 °C), Graphite (≥1750 °C) |
| Probe Geometry | Spherical-tip compression probe |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Alexsys 800 / Alexsys 1000 |
| Calorimetry Principle | Isothermal Heat-Flow Calvet |
| Temperature Range | 500–800 °C (Alexsys 800) / 800–1000 °C (Alexsys 1000) |
| Sample Crucible Count | 2 |
| Crucible Volume | 28 mL / 20 mL (dual configuration) |
| Temperature Accuracy | ±0.1% of reading |
| Calorimetric Accuracy | ±1% |
| Heat Flow Resolution | 12.5 µW |
| Dimensions (W × H) | 800 mm × 880 mm |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | BT2.15 |
| Temperature Range | –196 to +200 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–1 K/min |
| Detection Principle | 3D Calvet-type Heat Flow Calorimetry |
| Operating Modes | Isothermal & Non-Isothermal |
| Sample Environment | Open or Controlled-Atmosphere (including pressurized & mixing cells) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | C600 |
| Temperature Range | Ambient to 600 °C |
| Heating Rate | 0.01–2.000 °C/min |
| Calorimetric Resolution | 0.1 µW |
| Isothermal Stability (40 °C) | ±0.001 °C |
| Temperature Accuracy | ±0.1 °C |
| Calorimetric Accuracy | ±0.1% |
| Enthalpy Accuracy | ±1% |
| Reaction Cell Volume | 8.5–12.5 mL |
| RMS Noise | 1 µW |
| Sensitivity (Joule Effect at 30 °C) | 30 µW/mW |
| Dynamic Range | ±660 mW / ±2000 mW |
| Pressure Capability | Up to 1000 bar (14,500 psi) |
| Sample Form | Solid, Liquid, Powder, Thin Film, or Fiber |
| Dimensions (H×W×D) | 60×25×31 cm |
| Weight | 30 kg |
| Power Supply | 230 V, 50/60 Hz |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | C80 |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.05 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% |
| Heat Flow Resolution | 0.10 µW |
| Maximum Sample Volume | 12.5 mL |
| Pressure Rating | Up to 1000 bar |
| Sensor Type | 3D Calvet Thermopile Array |
| Sample Cell Materials | Stainless Steel, Hastelloy C, or Custom Alloys |
| Cell Types | Ampoule, Flip-Mix, Membrane-Mix, Fluid Circulation, Liquid Heat Capacity, Vacuum, Adsorption, High-Pressure Pressure-Monitoring, and Safety Cells |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | C80 |
| Operating Modes | Isothermal & Scanning |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 0.001–2 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.05 °C |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% |
| Heat Flow Resolution | 0.10 µW |
| Maximum Sample Volume | 12.5 mL |
| Cell Materials | Stainless Steel or Hastelloy C |
| Maximum Pressure Rating | 1000 bar |
| Cell Types | Ampoule, Flip-Mix, Membrane-Mix, Fluid Circulation, Liquid Heat Capacity, Vacuum, Adsorption, High-Pressure Manometric, Safety Cells |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | C80 Microcalorimeter |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Calorimetric Resolution | 0.10 µW |
| Maximum Sample Volume | 12.5 mL |
| Maximum Pressure Rating | 1000 bar |
| Sensor Principle | Calvet-type 3D-sensor |
| Thermal Enthalpy Accuracy | ±1% |
| Calorimetric Accuracy | ±0.1% |
| Temperature Precision | ±0.05 °C |
| Sample Cell Materials | Stainless Steel or Hastelloy C |
| Operating Modes | Isothermal and Scanning |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | CALVET C80 |
| Measurement Principle | 3D Heat-Flow Calorimetry (Calvet-type) |
| Temperature Range | Ambient to 300 °C |
| Temperature Precision | ±0.15 °C |
| Sample Capacity | Microscale (µg–mg range) |
| Operating Modes | Isothermal & Temperature-Scanning |
| Pressure Capability | Up to 1000 bar (with custom cells) |
| Vacuum Compatibility | Yes |
| Gas/Liquid Flow Integration | Yes |
| Compliance | ASTM E698, ISO 11357-4, USP <1031>, GLP/GMP-ready data audit trail (via C80 software) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Calvet CRYO |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Heat Flow (3D Calvet Principle) |
| Temperature Range | –196 °C to 200 °C |
| Temperature Resolution | 0.1 μW (heat flow resolution) |
| Sample Environment | Vacuum-jacketed, configurable for high pressure (up to 1000 bar), vacuum, inert gas, or reactive atmospheres |
| Sensor Architecture | Dual cylindrical thermopile arrays (480 thermocouples per array), fully surrounding sample and reference zones |
| Compliance | Designed for GLP/GMP environments |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | CALVET HT |
| Temperature Range | RT to 600 °C |
| Temperature Precision | ±0.5 °C |
| Measurement Principle | 3D Symmetrical Heat-Flow Calorimetry |
| Maximum Operating Pressure | 400 bar |
| Sample Configuration | Customizable high-pressure, vacuum-compatible, stirred, or gas-flow-integrated cells |
| Cooling | External recirculating water bath |
| Compliance | Designed for GLP/GMP-aligned workflows and ASTM E698, ISO 11358, and UN Test Series 3 compatibility |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Calvet HT (formerly C600) |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | 3D Calvet Calorimetry |
| Temperature Range | Ambient to 600 °C |
| Temperature Resolution | 0.5 μW (heat flow resolution) |
| Pressure Capability | Up to 400 bar |
| Sample Configuration | Dual-zone 3D thermopile sensor array |
| Compliance | Designed for GLP/GMP environments, compatible with ASTM E698, ISO 11357-4, and USP <1031> thermal stability protocols |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Calvet LV |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Isothermal |
| Temperature Range | Ambient to 200 °C |
| Sample Capacity | Up to 100 mL (e.g., two D-cell batteries) |
| Sensor Architecture | 2- or 4-channel 3D Calvet thermopile (up to 1,316 thermocouples per stack) |
| Pressure Capability | Up to 350 bar |
| Vacuum Compatibility | High vacuum |
| Optional Functions | In-situ stirring, gas flow control, electrochemical cycling (battery charge/discharge), pressure regulation & monitoring |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Calvet Pro |
| Instrument Type | Reaction Calorimeter |
| Measurement Principle | 3D Calvet-type Heat-Flow Calorimetry |
| Sample Mass Range | mg-scale |
| Temperature Range | –120 °C to 830 °C |
| Pressure Capability | Up to 500 bar (with optional high-pressure module) |
| Vacuum Compatibility | Yes |
| Cp Accuracy | High-precision absolute heat capacity measurement |
| Operating Modes | Isothermal, Dynamic Scanning, and Stepwise Temperature Programs |
| Sensor Architecture | Symmetric 3D thermopile array surrounding the sample and reference positions |
| Calibration Method | Joule-effect electrical calibration |
| Sample Environment Control | Integrated pressure regulation, monitoring, and control |
| Brand | SETARAM |
|---|---|
| Origin | USA |
| Model | CryoPro-2009 |
| Operating Temperature Range | –269 °C to 100 °C |
| Pressure Range | Vacuum to 200 bar (3000 psi / 100 psi dual-range transducers) |
| Cooling Medium | Liquid Helium or Liquid Nitrogen |
| Construction Material | 316 Stainless Steel |
| Sealing Method | Metal-Gasketed Arc-Welded Joints |
| Control System | LabVIEW-Based Automated Platform |
| Safety Features | Integrated Hydrogen Leak Detection and Flame Suppression System |
| Compliance | Designed for GLP/GMP-aligned workflows with full audit trail capability |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | DRC |
| Type | Laboratory-scale differential reaction calorimeter with dual-jacketed vessels, isothermal operation mode, and real-time ΔT monitoring via platinum resistance thermometers |
| Measurement Principle | Differential temperature-based heat flow quantification using Joule-effect calibration |
| Key Outputs | Reaction enthalpy (ΔHᵣₓₙ), mixing enthalpy (ΔHₘᵢₓ), adiabatic temperature rise (ΔTₐd), time-to-maximum-rate (tₘₐₓ), heat capacity (Cₚ), kinetic profiling |
| Compliance | Designed for GLP-compliant thermal safety assessment per ISO 11358, ASTM E698, and ICH Q1A(R2) guidelines |
| Software | CALISTO™ v5.0 with 21 CFR Part 11–compliant audit trail, raw data export (CSV, ASCII), and customizable reporting templates |
| Sample Compatibility | Liquid–liquid, liquid–gas, and heterogeneous slurries (max. working volume: 500 mL per vessel) |
| Temperature Control | Dual-circulating bath integration (±0.02 °C stability) |
| Sensor Resolution | ±0.001 °C ΔT detection limit |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | DRC evo |
| Type | Benchtop Differential Reaction Calorimeter |
| Operating Principle | Isothermal Micro-Differential Calorimetry (Based on Dual-Bath Temperature Difference Measurement) |
| Temperature Control | Dual Jacketed Reactor Vessels with External Circulating Bath |
| Detection | High-Precision Pt100 Differential Thermometry |
| Data Output | ΔT vs. t, Q vs. t, dQ/dt vs. t |
| Compliance | Designed for GLP/GMP-aligned thermal safety screening per ASTM E698, ISO 11358, and ICH Q1A(R2) guidance |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | DSC131 Evo |
| Temperature Range | −170 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.05 °C |
| Enthalpy Accuracy | ±2% |
| Heat Flow Precision | ±0.5% |
| Noise Level (at 200 °C) | 1.5 μW |
| Sensitivity (Indium Fusion) | 3 μV/mW |
| Dynamic Heat Flow Range | ±6000 mW |
| Time Constant | 3 s |
| Gas Control | Dual-gas switching capability |
| Pressure Rating (uncontrolled) | up to 500 bar (7255 psi) at 600 °C |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | DSC131 Evo |
| Temperature Range | −170 to 700 °C (LN₂ mode) / −80 to 500 °C (mechanical cooling) |
| Heating/Cooling Rate | 0–100 K/min |
| Dynamic Heat Flow Range | ±6000 mW |
| Gas Channels | 2 independent, software-controlled carrier gas lines |
| Pressure Rating | up to 500 bar with high-pressure crucibles |
| Sensor Type | removable heat-flux DSC sensor |
| Standard Software | CALISTO v5.x |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Flexi Hyco |
| Hydrogen Generation Principle | Water Electrolysis |
| Output Flow Rate | Up to 0.8 N·L/min or up to 1.6* N·L/min |
| Output Pressure | 10–200 bar (145–2900 psi) |
| Hydrogen Purity | 6.0–7.0 (v/v, ppm impurities) |
| Power Consumption | ~100 W |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Flexi WET200 |
| Instrument Type | Humidity Generator |
| Temperature Range | Ambient to 70 °C |
| Relative Humidity Range | 5–95% RH |
| Gas Flow Rate | 20–50 mL/min |
| Humidity Stability | ±0.3% RH |
| Compatible Gases | He, Air, Ar, N₂, CO₂ |
| Heating Stem Temperature | Ambient to 85 °C |
| Control System | Eurotherm-based PID loop with integrated RH, T, and flow feedback |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | GASPRO |
| Measurement Principle | Sievert-type Volumetric Method |
| Temperature Range | –260 °C to 500 °C (customizable beyond) |
| Pressure Range | Vacuum to 200 bar |
| Ultimate Vacuum | Two-stage vacuum system |
| Pressure Sensing | Dual-sensor architecture — high-pressure sensor (vacuum–200 bar, < 0.025 % FS accuracy), low-pressure sensor (vacuum–15 bar, < 0.12 % RD accuracy) |
| Minimum Detectable Uptake | 3 μmol (with Microdoser option) |
| Sample Mass Capability | Down to < 100 mg (patented US8132476 Microdoser) |
| Calibration Volumes | 5 pre-calibrated buffer volumes (5 mL to 1.2 L) |
| Gas Compatibility | CO₂, CH₄, N₂, Ar, H₂, He, and other non-corrosive gases |
| Safety Systems | Combustible gas detection, emergency pressure relief port |
| Control Modes | Isothermal PCT, adsorption/desorption kinetics, cyclic stability testing |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11 ready (optional), GLP/GMP-supporting data integrity framework |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | H2 Circulating Water Bath |
| Nominal Cooling Capacity | 1600 W |
| Temperature Control Range | 5–35 °C |
| Temperature Stability | ±0.1 °C |
| Pump Head (Max/Rated) | 28/21 m |
| Flow Rate (Max/Rated) | 60/33 L/min |
| Stainless Steel Reservoir Volume | 16 L |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W×D×H) | 360 × 550 × 860 mm |
| Interface Options | RS232/RS485 Serial Communication, WP7/WP12 Parallel I/O for On/Off & Alarm Relay Outputs |
| Construction | Full Stainless Steel Reservoir & Pump, Centrifugal Low-Noise Pump, Hermetic Refrigeration Compressor, Thermal Bypass PID Control Architecture |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Labsys Evo Cp |
| Temperature Range | Ambient to 1600 °C (single furnace) |
| Heating/Cooling Rate | 0.01–100 K/min |
| Balance Max Load | 20 g |
| Balance Range | ±1000 mg |
| Balance Resolution | 0.02 µg |
| DSC Sensitivity | 0.4 µW (sensor-dependent) |
| Cp Measurement Uncertainty | <2% |
| Atmosphere Options | Inert, Oxidizing, Reducing, Static, Dynamic, Vacuum |
| Gas Control | 3 Mass-Flow-Controlled Carrier Gases + 1 Auxiliary/Reaction Gas |
| Optional Autosampler (ASC) | Up to 25 Positions |
| EGA Compatibility | Direct Coupling to MS, FT-IR, GC |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Labsys Evo STA |
| Heating Rate | 0–100 K/min |
| Temperature Range | Ambient to 1600 °C |
| Temperature Stability | ±0.05 °C |
| Maximum Sample Mass | 1000 mg |
| Atmosphere Compatibility | Inert, Oxidizing, Reducing, Steam, Corrosive Gases |
| Balance Resolution | 0.02 µg |
| DSC Sensitivity | 0.4 µW (sensor-dependent) |
| Cp Accuracy | <2% error |
| Gas Control | 3 mass-flow-controlled carrier gases + 1 auxiliary/reactive gas |
| EGA Interface | Standard MS/FT-IR/GC coupling ports |
| Optional Autosampler | 25-position ASC |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Labsys Evo-DSC |
| Temperature Range | Ambient to 1600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–100 K/min |
| Balance Max Capacity | 20 g |
| Balance Range | ±1000 mg |
| Balance Resolution | 0.02 µg |
| DSC Sensitivity | 0.4 µW (sensor-dependent) |
| Cp Measurement Uncertainty | <2% |
| Atmosphere Options | Inert, Oxidizing, Reducing, Static, Dynamic, Vacuum |
| Gas Control | 3 Mass-Flow-Controlled Carrier Gases + 1 Auxiliary/Reaction Gas |
| EGA Compatibility | MS, FT-IR, GC |
| Optional Autosampler | 25-position ASC |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Labsys Evo-TGA |
| Temperature Range | RT–1600 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.02 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | MICRO DSC7 |
| Temperature Range | −45 °C to 120 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Sample Cell Volume | 450 µL (intermittent mode) |
| Baseline Noise (RMS) | 0.4 µW |
| Minimum Detectable Heat Flow | 0.002 µW |
| Maximum Controllable Pressure | 1000 bar |