SETARAM
Filter
Showing 31–60 of 61 results
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Microcalvet |
| Instrument Type | Reaction Calorimeter |
| Measurement Principle | 3D Calorimetric Sensor with Joule Calibration |
| Temperature Range | −45 °C to 120 °C |
| Accuracy | ±0.15% |
| Sample Capacity | Variable (micro-to-milligram scale) |
| Pressure Capability | Up to 1000 bar (with optional high-pressure cells) |
| Compatibility | Vacuum, inert atmosphere, reactive gas environments |
| Thermal Control | Peltier-based 3-axis symmetric heating/cooling |
| Interface | Modular coupling with BET analyzers, gas sorption systems, humidity generators, and high-pressure gas controllers |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Microcalvet Ultra |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Isothermal & Scanning Calorimetry |
| Temperature Range | –20 °C to 170 °C |
| Sensitivity | Sub-microwatt (µW) thermal power resolution |
| Sample Environment | Compatible with high-pressure (up to 400 bar), vacuum, gas-controlled, and stirred/mixed configurations |
| Interfacing Capability | Integrated coupling with BET surface analyzers, physicochemical adsorption systems, humidity generators, and high-pressure/vacuum gas controllers |
| Calibration Method | Joule calibration with 3D Calvet sensor architecture |
| Sample Cell Options | Interchangeable, chemically resistant, easy-clean crucibles for solids, powders, gels, liquids, and slurries |
| Compliance | Designed for GLP/GMP environments |
| Brand | SETARAM |
|---|---|
| Origin | USA |
| Model | PCT Pro E&E |
| Instrument Type | Physical & Chemical Sorption Analyzer |
| Temperature Range | –269 °C to 500 °C |
| Pressure Range | Vacuum to 200 bar |
| Pressure Accuracy | ±1% FS |
| Detection Limit | 3 µg (equivalent to 0.3 wt% gas uptake on 1 mg sample) |
| Integrated Pressure Sensors | 4 (auto-switching dual-range) |
| Gas Compatibility | H₂, CO₂, CH₄, NH₃ |
| Sample Cell Options | 6 types (standard, high-temp, liquid, thin-film, cryogenic, micro-dosing) |
| Safety Systems | Combustible gas detection, multi-point T/P monitoring, inert-gas purged transfer pathway |
| Software Platform | LabVIEW-based with real-time data acquisition, automated sequence execution, and audit-trail-capable operation |
| Brand | Setaram |
|---|---|
| Origin | USA |
| Model | PCTPro-Evo |
| Temperature Range | –269 °C to 500 °C |
| Pressure Range | Vacuum to 200 bar |
| Pressure Accuracy | ±1% |
| Detection Limit | 3 µg (equivalent to 0.3 wt% gas uptake on 1 mg sample) |
| Gas Compatibility | H₂ only |
| Sensor Configuration | Four auto-switching pressure transducers with dual-range capability |
| Sample Cell Options | Six interchangeable cells (standard, high-temperature, liquid, thin-film, cryogenic, micro-dosing) |
| Safety Systems | Integrated combustible gas detection, multi-point temperature/pressure monitoring, inert-gas purged transfer pathway |
| Software Platform | LabVIEW-based real-time control and analysis suite |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Sensys DSC High-Pressure Calvet Microcalorimeter |
| Temperature Range | −120 to +830 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–30 K/min |
| Maximum Pressure | 500 bar at 600 °C |
| Pressure Monitoring Limit | 400 bar at 600 °C |
| DSC Sample Volume | up to 320 μL |
| DSC Detection Limit | 5 μW |
| DSC Resolution | 0.4 μW |
| TGA Max Sample Mass | 35 g |
| TGA Resolution | 0.03 μg |
| Gas Lines | 3 carrier + 1 reactive/auxiliary |
| Atmosphere Compatibility | Oxidizing, reducing (H₂, CO), corrosive (H₂S, NH₃), steam |
| Auto-sampler Capacity | 48 positions |
| Software | Calisto v5.x with Cp measurement module |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys Evo TG-DSC |
| Temperature Range | –120 to 830 °C |
| Heating/Cooling Rate | 0.01–30 °C/min |
| Temperature Stability | ±0.02 °C |
| Max Sample Mass | 3 g |
| Pressure Range (HP-DSC) | up to 500 bar (controlled up to 400 bar) |
| Atmosphere Compatibility | inert, oxidizing, reducing, corrosive (e.g., H₂S, NH₃), humidified, vacuum, steam |
| Balance Resolution | 0.002 µg |
| DSC Sensitivity | < 0.035 µW |
| TG Baseline Drift | < 10 µg (full-scale scan) |
| TG Baseline Repeatability | ±1 µg |
| Gas Control | integrated mass flow controllers, 3 carrier + 1 reactive gas channels |
| Sample Holder Options | TG-DSC and TG-DTA dual-mode crucibles |
| Optional Features | ASC auto-sampler (48 positions), humidity control module, FT-IR/MS/GC coupling interfaces |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys Evolution |
| Temperature Range | –120 to 830 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–30 °C/min |
| Mass Range | 3000 mg |
| Vacuum Level | <10⁻¹ mbar |
| TG Resolution | 0.002 µg |
| Atmosphere Options | Inert, Oxidizing, Reducing, Static/Dynamic, Vacuum, Corrosive (e.g., H₂S, NH₃), Humidified Steam |
| Gas Control | Integrated 3-channel mass flow controller (2 carrier + 1 reactive gas), programmable mixing ratio (1:99 to 50:50) |
| TG Baseline Drift | <10 µg over full scan |
| TG Baseline Repeatability | ±1 µg |
| Evolved Gas Analysis Compatibility | MS, FT-IR, GC |
| Optional Autosampler | 48-position ASC |
| Thermal Stability | ±0.001 to ±0.00001 °C (isothermal) |
| Sample Chamber Volume | 320 µL |
| Sensor Architecture | Calvet-type 3D thermopile sensor |
| Software | Calisto v6.x (21 CFR Part 11 compliant, GLP/GMP audit trail enabled) |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys Evolution |
| Temperature Range | -120 to +830 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–30 K/min |
| Maximum Sample Cell Pressure | 500 bar (at 600 °C) |
| Pressure Monitoring Range | Up to 400 bar (at 600 °C) |
| DSC Detection Limit | 5 µW |
| DSC Resolution | 0.4 µW |
| Sample Volume Capacity | 250 µL (up to 320 µL with extended cell) |
| TG Compatibility | Yes (up to 35 g sample, 0.03 µg resolution) |
| Atmosphere Options | Oxidizing, reducing (H₂, CO), corrosive (H₂S, NH₃), steam, mixed gases (1–99% ratio) |
| Autosampler | 48-position |
| Software | Calisto v5.x (GLP-compliant, audit trail enabled) |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys-evo |
| Instrument Type | High-Pressure Chemisorption Calorimeter |
| Temperature Range | −120 to +830 °C |
| Temperature Repeatability | ±0.1% |
| Programmable Scan Rate | 0.01–30 °C/min |
| Heat Flow Resolution | 0.4 μW |
| Detection Limit | 5 μW |
| Maximum Sample Cell Pressure | 500 bar at 600 °C |
| Controlled/Measured Pressure Range | up to 400 bar at 600 °C |
| Sample Chamber Volume | 250 μL |
| Gas Channels | 3 carrier + 1 reactive/auxiliary |
| Atmosphere Compatibility | oxidizing, reducing (H₂, CO), corrosive (H₂S, NH₃), steam |
| Automated Sampler Capacity | 48 positions |
| Optional Coupling | TGA (35 g max, 0.03 μg resolution), FT-IR, MS, GC, humidity controller |
| Brand | Setaram |
|---|---|
| Origin | Beijing, China (jointly developed by Chinese, French & Swiss teams) |
| Model | Setline DSC |
| Temperature Range | −170 to 700 °C |
| Programmable Heating/Cooling Rate | 0.01–100 °C/min |
| Temperature Accuracy | ±0.1 °C (vs. standard metals) |
| Temperature Precision | ±0.05 °C |
| DSC Signal Range | ±6000 mW |
| Heat Flow Resolution | 0.1 µW |
| Temperature Stability | ±0.1 °C (standard metal) |
| Sample Capacity | Single-position |
| Cooling Options | Manual/auto liquid nitrogen (−170 to 400 °C), He/Ar/dry air gas-cooling (−70 to 400 °C) |
| Gas Control | Dual-channel programmable gas switching |
| Software | Calisto 2.0 (data acquisition & processing with audit trail, user permissions, macro automation, Cp calculation) |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (Manufactured under French R&D supervision) |
| Model | Setline DSC+ |
| Temperature Range | −170 °C to 700 °C |
| Temperature Accuracy | ±0.1 °C (vs. certified standards) |
| Heating/Cooling Rate | 0.01–100 K/min |
| Heat Flow Resolution | 0.1 µW |
| Heat Flow Range | ±6000 mW |
| Calorimetric Accuracy | ±0.8% (vs. standard metals) |
| Calorimetric Precision | ±0.1% |
| Atmosphere Control | Dual independent gas flow channels with software-programmed auto-switching |
| Sensor Type | Flat-plate NiCr–Constantan thermopile |
| Cooling Options | Manual/automated LN₂ (−170 °C to 400 °C), He gas cryo-cooling (−70 °C to 200 °C), dry air/N₂/Ar (−50 °C to 400 °C) |
| Crucible Options | Al₂O₃, Al (30 & 100 µL), Incoloy high-pressure (30 µL, up to 500 bar at 600 °C), 316L stainless steel (optional) |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (Manufactured under France-China joint development) |
| Model | Setline TGA |
| Temperature Range | Ambient to 1100 °C |
| Temperature Accuracy | ±0.3 K |
| Temperature Precision | ±0.1 °C |
| Heating/Cooling Rate | 0.01–50 K/min |
| Dynamic Mass Range | ±20 mg / ±200 mg |
| Balance Sensitivity | 0.0023 µg |
| Mass Accuracy | 0.01% |
| Mass Precision | 0.005% |
| Maximum Sample Mass | 0.3 g |
| Baseline Drift | 25 µg |
| Baseline Repeatability | ±5 µg |
| Atmosphere Options | Inert (N₂, Ar, He) or Oxidizing (air, O₂) |
| Gas Flow Rate | 10–100 mL/min |
| Crucible Materials | Al, Al₂O₃, Pt, Quartz (130–250 µL volume) |
| Cooling | Integrated water-cooled furnace |
| Software | CALISTO 2.0 Thermal Analysis Suite |
| Power Supply | 230 V, 50/60 Hz |
| Dimensions (H×W×D) | 650(850)×400×500 mm |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys EVO |
| Temperature Range | −150 °C to 1750 °C (upgradable to 2400 °C) |
| Heating Rate | 0–100 K/min (full range) |
| Max. TG Sample Capacity | 35 g / 100 g |
| TG Resolution | 0.002 µg / 0.02 µg |
| TG Baseline Repeatability | <10 µg (RT to 1750 °C) |
| DSC Resolution | 1 µW |
| DTA Resolution | 0.4 µW |
| Gas Lines | 3 carrier + 1 auxiliary/reactive gas, controlled via MFCs and solenoid valves |
| Atmosphere Options | inert, oxidative, reductive, steam, corrosive gases |
| Vacuum System | up to 10⁻⁴ mbar (10⁻² torr) |
| EGA Compatibility | MS, FT-IR, GC |
| Optional Modules | Wetsys humidity control, H₂-safe operation kit, corrosive gas kits (SO₂, NH₃, H₂S) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys Evo TMA |
| Temperature Range | −150 °C to 2400 °C |
| Heating/Cooling Rate | 0–100 °C/min |
| Displacement Resolution | 0.2 nm |
| Displacement Noise | 5 nm |
| Force Range | 0–3.5 N (controllable) |
| Sample Length | 0–20 mm |
| Sample Diameter | ≤10 mm |
| Maximum Displacement Range | ±2 mm |
| Load Capacity | −150 g to +350 g |
| Measurement Modes | Compression, Penetration, 3-Point Bending, Tensile, Dilatometric, Volumetric Expansion |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys Evo16 / Evo18 / Evo24 |
| Temperature Range | –150 °C to 1750 °C (upgradable to 2400 °C) |
| Heating Rate | 0–100 K/min (full range) |
| Max. TG Sample Capacity | 35 g / 100 g |
| TG Resolution | 0.002 µg / 0.02 µg |
| TG Baseline Repeatability | <10 µg (RT to 1750 °C) |
| DSC Resolution | 1 µW |
| DTA Resolution | 0.4 µW |
| Gas Channels | 3 carrier + 1 auxiliary/reactive gas, all MFC-controlled |
| Atmosphere Options | Inert, oxidative, reductive, steam, corrosive gases |
| Vacuum Level | ≤1×10⁻⁴ mbar |
| EGA Compatibility | MS, FT-IR, GC interfaces standard |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys Evolution |
| Temperature Range | RT to 2400 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.03–0.3 µg |
| Heating/Cooling Rate | 0–100 K/min |
| Atmosphere Options | Inert, Oxidizing, Reducing, Steam, Corrosive Gases |
| Vacuum Capability | Down to 10⁻⁴ mbar |
| Modular Compatibility | DTA, DSC, TMA |
| Gas Mixing | Dual purge + protective gas with mass flow control (50/50 to 1/99 ratio) |
| Humidity Integration | Optional RH-controlled module |
| Evolved Gas Analysis (EGA) | Heated capillary transfer up to 200 °C for FTIR/MS/GC-MS coupling |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys STA 2400°C |
| Temperature Range | –150 to 2400 °C |
| Heating Rate | 0.01–100 K/min |
| Max. Sample Mass | 35 g (standard), 100 g (high-capacity option) |
| TG Resolution | 0.002 µg / 0.02 µg |
| TG Baseline Repeatability | <10 µg (RT to 1750 °C) |
| DSC Resolution | 1 µW |
| DTA Resolution | 0.4 µW |
| Atmosphere Control | Inert, oxidizing, reducing, steam, corrosive gases (static/dynamic) |
| Gas Configuration | 3 carrier + 1 auxiliary/reactive gas lines with MFCs and solenoid valves |
| Vacuum Level | ≤10⁻⁴ mbar |
| EGA Compatibility | Direct coupling ports for MS, FT-IR, GC |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS DUO (formerly TAG) |
| Temperature Range | Ambient to 1750 °C |
| Temperature Accuracy | ±0.25 K |
| Balance Sensitivity | 0.002 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Maximum Sample Mass | 35 g |
| Baseline Drift | ≤5 µg at 1750 °C |
| Simultaneous Sample Capacity | Multiple |
| Atmosphere Control | 3-channel mass-flow-controlled carrier gas (4–200 mL/min) + 1 auxiliary/reactive gas channel (0.3–16 mL/min) |
| Crucible Options | Al₂O₃, W, graphite, Pt, quartz, Al (55–1500 µL) |
| Sensor Configurations | TGA, DTA, and DSC rods (interchangeable) |
| Dimensions (H×W×D) | 170 × 60 × 55 cm |
| Weight | 145 kg |
| Power Supply | 230 V, 50/60 Hz |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themys Flash |
| Operating Environment | Ambient Pressure |
| Simultaneous Sample Capacity | Up to 5 |
| Instrument Type | Universal TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Dynamic Weighing Range | ±20 mg, ±200 mg |
| Balance Sensitivity | 0.0023 µg |
| Heating/Cooling Rate | Up to 600 K/min |
| Maximum Sample Mass | 35 g |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS H2 |
| Temperature Range | Ambient to 1000/1600/1750 °C |
| Heating Rate | 0.01–100 °C/min |
| Max Sample Mass | 35 g |
| Atmosphere | 3 Gas Lines (including dedicated H₂ line) |
| Safety | Dual H₂/O₂ Sensors, Interlocked Furnace & Balance, Emergency H₂ Shutoff, Vacuum- and High-Temp-Interlocked Access |
| Vacuum Level | < 5×10⁻² mbar |
| Resolution | 0.4 μW (DTA), 1 μW (DSC), 0.002 μg (TGA), 0.02 μg (microbalance), 0.2 nm (TMA) |
| Quantitative Accuracy | ±1.4% (DTA), ±0.9% (DSC), ±0.06% (TGA), ±0.08×10⁻⁶/°C (TMA expansion) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themys |
| Temperature Range | 0–1750 °C (up to 2400 °C in optional configurations) |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.00059 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Maximum Sample Mass | 100 g |
| Baseline Drift | ±3 µg |
| Simultaneous Measurement Capability | TGA, DTA, DSC, STA, TMA, EGA |
| Atmosphere Options | Inert, oxidizing, reducing, corrosive (e.g., H₂, NH₃, SO₂, H₂S), vacuum (primary <5×10⁻² mbar |
| Gas Control | Up to 3 independent mass flow controllers (MFCs), programmable gas switching, heated EGA interfaces (4×, up to 300 °C) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | THEMYS HP |
| Temperature Range | Ambient to 1200 °C |
| Pressure Range | Up to 150 bar |
| Sample Capacity | 35 g |
| Balance Sensitivity | 0.0023 µg |
| Baseline Drift | ±200 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Crucible Volume | 1300 µL |
| Gas Configuration | 3-channel mass flow controlled (2 MFCs standard with auxiliary gas option) |
| Vacuum Capability | <1 mbar (primary), <5×10⁻² mbar (forced) |
| Safety Compliance | EU PED 2014/68/EU, Group 2 gases |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS LV |
| Temperature Range | Room Temp to 2000 °C (TGA/DTA/TG-DTA), up to 1600 °C (TG-DSC/DSC/TMA) |
| Sample Capacity | Up to 100 g / 18.1 mL |
| Balance Sensitivity | 0.02 µg |
| Heating/Cooling Rate | 0.01–20 K/min |
| Maximum Crucible Volume | 18.1 mL |
| TMA Resolution | 1.6 nm |
| TMA Measurement Range | ±6 mm |
| Gas Control | 3-channel MFC-controlled gas lines (including optional corrosive gas path) |
| Vacuum Capability | Primary vacuum (< 5×10⁻² mbar), secondary vacuum optional |
| Balance Load Capacity | ±200 mg (low-load mode), ±2000 mg (high-load mode) |
| DSC/DTA Accuracy | ±2% (heat flow), ±1 °C (temperature, calibrated vs. metal standards) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themys One |
| Temperature Range | RT–1150°C / RT–1600°C |
| Heating Rate | 0.01–100 °C/min |
| Atmosphere | Inert or reactive gas |
| Compliance | ASTM E1131, ISO 11358, USP <1227>, ISO 17972 (Cp), GLP/GMP-ready software architecture |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS TMA |
| Instrument Type | Thermomechanical Analyzer (TMA) |
| Temperature Range | –150 to 2400 °C (configurable up to 2400 °C with high-temp furnace option) |
| Heating/Cooling Rate | 0–100 °C/min |
| Displacement Resolution | 0.2 nm |
| Displacement Noise | 5 nm |
| Force Range | 0–3.5 N (bidirectional, programmable) |
| Sample Length | 0–20 mm |
| Sample Diameter | ≤10 mm |
| Maximum Displacement Range | ±2 mm |
| Load Capacity | –150 to +350 g (equivalent force range) |
| Probe Options | Compression, Penetration, 3-Point Bending, Tensile, Dilatometric, and Volumetric probes |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | uSC |
| Temperature Range | -40 °C to 200 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.001–1.2 K/min |
| Calorimetric Channels | 4 (2 sample + 2 reference) |
| Sample Cell Volume | 850 µL |
| Baseline Noise | 0.2 µW RMS |
| Sensitivity (Joule effect at 30 °C) | 100 µV/mW |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% RMS |
| DSC Resolution | 0.02 µW / 0.002 µW |
| Pressure Range (measurable & controllable) | 400 bar (5800 psi) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Manufacturer | AlyXan (co-developed with SETARAM) |
| Model | VistoMS |
| Detection Principle | Fourier Transform Ion Cyclotron Resonance Mass Spectrometry |
| Mass Range | up to 300 u |
| Mass Accuracy | ≤ 0.01 u |
| Detection Limit | sub-ppm (parts per million) |
| Ionization Mode | Soft chemical ionization (e.g., H₃O⁺ reagent ions) |
| Vacuum Architecture | Dual-stage differential vacuum system (atmospheric pressure interface → primary vacuum → secondary high vacuum measurement region) |
| Sample Introduction | Direct coupling to thermal analyzer (TGA, DSC, or TGA-MS compatible platforms) |
| Measurement Duration per Scan | ~2 seconds |
| Environmental Control | Humidity-regulated gas atmosphere capability |
| Quantification | Calibration-free relative quantitation across full mass range |
| Compatibility | Real-time evolved gas analysis (EGA) for organic and polymeric materials |
| Brand | SETARAM |
|---|---|
| Model | Setline STA / Setline STA+ |
| Temperature Range | Ambient to 1100 °C |
| Heating Rate | 0.01–50 °C/min |
| Temperature Stability | ±0.05 °C |
| Max Sample Mass | 20 g |
| Atmosphere Options | Air, O₂, Inert (N₂, Ar) |
| Balance Resolution | 0.02 µg |
| TG Dynamic Range | ±200 mg / ±1000 mg |
| DSC Sensitivity | 1 µW |
| DSC Enthalpy Accuracy | ±1% |
| Optional Autosampler | 49-position |
| Cooling Method | Water-cooled furnace liner |
| Software | Calisto 2.0 (Data Acquisition & Processing) |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (assembled with French-imported core components) |
| Model | Setline-dsc |
| Temperature Range | –170 to 700 °C |
| Temperature Accuracy | ±0.1 °C (vs. certified metal standards) |
| Heating/Cooling Rate | 0.01–100 K/min |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Sigmameter |
| Sample Max Dimension | Ø30×20 mm |
| Magnetic Field Gap | 800 kA·m⁻¹ (10,000 Oe) |
| Sensitivity | 1 mg Co |
| Accuracy | ±1% |
| Measurement Time | 5 s |
| Units Supported | emu·g⁻¹ (Gauss·cm³·g⁻¹), SI (µT·m³·kg⁻¹), Co wt% |
| Automation | Fully Automated |
| Maintenance | Maintenance-Free Design |
| Compliance | Designed for ISO/IEC 17025-aligned QC labs |