| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | CFU-750W-M2 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 20 kHz ± 1 kHz |
| Ultrasonic Power Output | 750 W |
| Sample Throughput | 5–50 L/h |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | DNU-1020 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 8–12 °C |
| Operating Frequency | 20 kHz |
| Ultrasonic Power Output | 30 W |
| Sample Volume Capacity | 500 µL – 1000 µL |
| Sample Throughput | Single-tube processing per cycle |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 30–40 kHz |
| Total Ultrasonic Power | 4 × 50 W (200 W total) |
| Sample Volume per Tube | 500 µL – 1000 µL |
| Throughput | 24 samples per run |
| Temperature Control Range | 4–10 °C (Peltier-based cooling) |
| Compatible Tube Format | Standard 2 mL microcentrifuge tubes |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | JY88-IIN |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–99.9 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 250 W (adjustable from 1% to 100%) |
| Sample Volume Capacity | 10–200 mL |
| Display | 7-inch Touchscreen Interface |
| Duty Cycle Range | 0.1–99.9% |
| Standard Probe | 6 mm titanium alloy (TC4) horn |
| Optional Probes | 2 mm, 3 mm, 10 mm |
| Safety Features | Overtemperature, overload, and timer alarms |
| Dimensions (Main Unit) | 430 × 245 × 300 mm |
| Weight (Unit + Transducer) | 8.5 kg |
| Optional Acoustic Enclosure Dimensions | 345 × 345 × 535 mm |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 250 W |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | 0–99.9 °C |
| Sample Volume Capacity | 10–200 mL |
| Sample Throughput | Single-sample processing |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 900 W (adjustable from 1% to 99%) |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 0.5–600 mL |
| Sample Throughput | Single-sample processing |
| Transducer Material | Titanium Alloy |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | JY92-IIN |
| Ultrasonic Power Output | 650 W (adjustable from 1% to 99%) |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 100 μL–500 mL |
| Sample Throughput | Single-sample processing per cycle |
| Transducer Material | Titanium Alloy Horn Assembly |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 150 W |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | 0–99.9 °C |
| Sample Volume Capacity | 10–100 mL |
| Sample Throughput | Single-sample processing |
| Compliance | CE-marked design |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SCIENTZ-650J |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–99.9°C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 650 W (adjustable from 1% to 100% in 1% increments) |
| Sample Volume Capacity | 100 µL – 250 mL |
| Display | 7-inch capacitive touchscreen |
| Probe Options | Standard 6 mm tapered probe |
| optional probes | 2, 3, 8, 10, and 13 mm diameter |
| Probe Material | TC4 titanium alloy (aerospace-grade α+β titanium alloy) |
| Cooling Mode | External circulating chiller compatible / internal temperature monitoring with auto-shutdown |
| Safety Features | Overload protection, overtemperature cutoff (user-definable threshold), real-time thermal monitoring, timed operation with ±0.1 s resolution |
| Control Modes | Continuous and pulsed ultrasonication (pulse on/off ratio programmable) |
| Enclosure | Acoustically damped steel chassis with integrated sound-absorbing panels |
| Dimensions (W×D×H) | 312 × 334 × 510 mm |
| Weight | Approx. 28 kg |
| Internal Illumination | LED lighting for sample chamber visibility |
| Sanitization | UV-C lamp integrated into lid assembly (optional activation cycle) |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-950E |
| Temperature Range | 0–99°C |
| Operating Frequency | 20–25 kHz (auto-tracking & adaptive) |
| Ultrasonic Power Output | 5–950 W (adjustable) |
| Sample Volume Capacity | 100 µL – 600 mL (probe-dependent) |
| Brand | SCIENTZ |
|---|---|
| Origin | Zhejiang, China |
| Model | UP-250 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 19–25 kHz |
| Ultrasonic Output Power | 250 W |
| Sample Volume Capacity | 0.5–10 mL |
| Display | 4.3-inch Touchscreen |
| Control Modes | Automatic & Manual (footswitch optional) |
| Pulse Duration | 0.1–99 s (on/off) |
| Total Sonication Time | 0.1–99 min |
| Horn Diameter | 3 mm |
| Dimensions (UP-250) | 270 × 245 × 116 mm |
| Power Supply | 220 V / 50 Hz |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | UP-250 |
| Ultrasonic Power | 250 W |
| Operating Frequency | 19–25 kHz |
| Sample Volume Capacity | 100 µL – 10 mL |
| Battery Runtime (UP-250S variant) | Up to 4 h continuous operation |
| Temperature Monitoring | Integrated sensor with over-temperature alarm |
| Operation Modes | Manual (foot-switch compatible) and Automatic |
| Portability | Fully handheld, battery-powered (UP-250S), no external power required |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 250 W |
| Operating Frequency | 19–25 kHz |
| Sample Volume Range | 100 µL – 100 mL |
| Power Source | Integrated Rechargeable Lithium Battery (4 h continuous operation) |
| Control Modes | Manual (foot switch) and Automatic |
| Temperature Monitoring | Real-time display with over-temperature alarm |
| Sample Compatibility | Microtubes, PCR tubes, 96-well plates (direct immersion), vials up to 10 mL capacity |
| Adjustable Parameters | Output amplitude (0–100%), pulse duration (0.1–9.9 s), cycle time (0.1–9.9 s) |
| Brand | Sonics |
|---|---|
| Origin | Belgium |
| Model | NEW BIORUPTOR PICO |
| Ultrasonic Power | 300 W |
| Operating Frequency | 40 kHz |
| Temperature Range | 4–25°C (ambient) |
| Sample Volume | 20 µL–2 mL |
| Throughput | Up to 16 samples per run |
| Sample Vessel Compatibility | 0.2 mL, 0.65 mL, 1.5 mL, and 15 mL microcentrifuge tubes |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VC255 / VC505 / VC800 |
| Output Power | 800 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 250 µL to several liters |
| Dimensions (H×W×D) | 235 × 190 × 340 mm |
| Weight | 6.8 kg |
| Transducer Type | CV334 Sealed Piezoelectric Converter (PZT) |
| Probe Standard | Φ13 mm Titanium Alloy (Ti-6Al-4V), 136 mm length, 340 g |
| Timer Range | 0–99 min 59 sec (microprocessor-controlled) |
| Pulse Mode | Adjustable 1–59 sec ON/OFF cycles |
| Remote Control Capability | Yes |
| Input Voltage | 220–240 V, 50/60 Hz |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VC800/VCX800 |
| Ultrasonic Output Power | 800 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 1–100 °C |
| Sample Volume Capacity | 250 µL to several liters |
| Number of Samples per Run | 1 |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VCX130AT |
| Instrument Type | Ultrasonic Cell Disruptor |
| Power Output | 130 W |
| Operating Frequency | 20 kHz |
| Maximum Nebulization Rate | 16 L/hr |
| Droplet Size | 45 µm |
| Max. Fluid Viscosity | 60 cP |
| Nebulization Mode | Pressure-Free |
| Probe Replacement Cost | Low |
| Ambient Contamination | Minimal |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VCX130PB (Hand-Triggered Pulse) & VCX130FSJ (Foot-Switch Pulse) |
| Output Power | 130 W |
| Frequency | 20 kHz |
| Dimensions (H×W×D) | 115 × 250 × 320 mm |
| Weight | 3.0 kg (VCX130PB), 3.2 kg (VCX130FSJ) |
| Transducer Models | CV188 (VCX130PB), CV18 (VCX130FSJ) |
| Transducer Specs | Ø32 mm × 146 mm, 340 g, cable length 1.5 m (VCX130PB), 1.8 m (VCX130FSJ) |
| Standard Probe | Ø3 mm titanium alloy (Ti-6Al-4V), 138 mm length, volume range 250 µL–10 mL, part #630-0422 |
| Input Power | 220 V, 50/60 Hz |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VCX1500 |
| Output Power | 1500 W |
| Operating Frequency | 20 kHz |
| Maximum Continuous Flow Rate | 100 L/h (with optional flow-through chamber) |
| Standard Probe Tip Diameter | 25 mm |
| Probe Material | Titanium Alloy (Grade 5) |
| Cooling | Air-Cooled Transducer |
| Control System | Microprocessor-Based with Real-Time Parameter Display |
| Timer & Pulse Mode | Yes |
| Amplitude Adjustment | Variable (0–100%) |
| Input Power Requirement | 200 V, 50/60 Hz |
| Dimensions (H×W×D) | 279.4 × 380 × 463.5 mm |
| Net Weight | 9.5 kg |
| Transducer Model | CV294 |
| Transducer Dimensions | Ø76.2 mm × 158.7 mm |
| Transducer Weight | 900 g |
| Cable Length | 3 m |
| Compliance | CE, UL Listed |
| Standard Configuration | Host unit, 25 mm probe, tool kit, operator manual |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VCX150PB / VCX150 |
| Output Power | 150 W |
| Frequency | 20 kHz |
| Sample Volume Range | 150 µL – 150 mL |
| Display | Digital Power Readout |
| Control | Microprocessor-Based |
| Pulse Mode | Manual or Programmable (1–59 s ON/OFF, up to 10 h timer) |
| Transducer | CV188 (VCX150PB) / CV18 (VCX150) |
| Probe Options | φ2 mm, φ3 mm, φ6 mm, φ13 mm (Ti-6Al-4V alloy) |
| Dimensions (H×W×D) | 115 × 250 × 320 mm (VCX150PB), 115 × 250 × 320 mm (VCX150) |
| Weight | 3.0 kg (VCX150PB), 3.2 kg (VCX150) |
| Input Voltage | 220–240 V, 50/60 Hz |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VCX255 / VCX500 / VCX800 |
| Ultrasonic Output Power | 255 W / 500 W / 800 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 250 µL to several liters |
| Temperature Control Range | 1–100 °C |
| Dimensions (H×W×D) | 235 × 190 × 340 mm |
| Weight | 6.8 kg |
| Transducer Type | CV334 Piezoelectric Converter (PZT) |
| Probe Standard | Φ13 mm Titanium Alloy (Ti-6Al-4V), 136 mm length, 340 g |
| Power Input | 220–240 V, 50/60 Hz |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VCX500/VCX800 |
| Output Power | 500 W / 800 W |
| Dimensions (H×W×D) | 235 × 190 × 340 mm |
| Weight | 6.8 kg |
| Timer Range | 1 s – 10 h |
| Pulse Mode | Independent ON/OFF switch |
| Standard Probe | Φ13 mm threaded, replaceable tip, length 138 mm, sample volume 10–250 mL |
| Amplitude | 124 µm (Φ13 mm), 61–89 µm (larger probes) |
| Sample Volume Capacity | 0.01–1000 mL |
| Compliance | CE, UL, RoHS |
| Software Interface | None (standalone microprocessor control) |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 04711-35 (500 W), 04711-45 (750 W) |
| Instrument Type | Ultrasonic Cell Disruptor |
| Power Output | 500 W / 750 W |
| Frequency | 20 kHz |
| Sample Volume Range | 250 µL – 1000 mL |
| Continuous Flow Rate | up to 19 L/h |
| Temperature Control Range | 1–100 °C |
| Timer Range | 1 s – 10 h |
| Pulse Cycle | On/Off adjustable from 0.1 s to 10 s |
| Probe Material | Ti-6Al-4V titanium alloy |
| Transducer | CV33 PZT ceramic, sealed housing |
| Dimensions (Generator) | 235 × 190 × 340 mm |
| Weight (Generator) | 7 kg |
| Input Power | 220 V / 50 Hz |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 04711-65 (750 W), 04711-75 (500 W) |
| Output Power | 500 W / 750 W |
| Frequency | 20 kHz |
| Probe Tip Diameter Options | 2, 3, 6, 13, 19, 25 mm |
| Sample Volume Range | 250 µL – 1000 mL (batch) |
| Timer Range | 1 s – 10 h |
| Pulse Mode | On/Off duration adjustable from 0.1 s to 10 s |
| Transducer | CV33 PZT ceramic, sealed housing, 63.5 mm Ø × 183 mm L, 900 g |
| Standard Probe | 13 mm Ti-6Al-4V titanium alloy, 136 mm L, 340 g |
| Dimensions (Generator) | 235 × 190 × 340 mm |
| Weight (Generator) | 7 kg |
| Input Power | 220 V, 50 Hz |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Supmile |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KBS-650 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 20 kHz |
| Maximum Ultrasonic Power Output | 650 W |
| Adjustable Power Range | 0–100% |
| Sample Volume Capacity | 0.5–500 mL |
| Processing Volume per Cycle | Up to 600 mL |
| Probe Diameter Options | Φ2, Φ3, Φ8 (standard), Φ10, Φ12, Φ15 mm |
| Duty Cycle Adjustment | 1–999 s |
| Timer Range | 0–24 h |
| Transducer Material | TC4 Titanium Alloy |
| Safety Features | Overload Protection, Audible/Visual Alarm, LED Illuminated Touch Interface, Motorized Vertical Probe Positioning with Wireless Remote Control |
| Structural Design | Modular Stackable Assembly (Optional Integrated or Separated Generator–Transducer Configuration) |
| Brand | SYC (Sycs) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SCQ-1000F |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1000 W |
| Operating Frequency | 20 kHz or 25 kHz (selectable) |
| Temperature Range | Ambient |
| Sample Volume Capacity | 0.5–1000 mL |
| Sample Throughput | Up to 500 samples per batch |
| Timer Range | 1 s – 9 h 59 min 59 s (programmable in 1-s increments) |
| Probe Tip Diameters Available | 5, 8, 10, 15, 20, 25, 30 mm (user-selectable) |
| Input Voltage | 220 V AC ±10% |
| Protection Features | Overvoltage, overcurrent, and output short-circuit protection |
| Display | Digital LCD with real-time power and current monitoring |
| Control Architecture | Microprocessor-based with IGBT power stage |
| Sweep Frequency Function | Enabled for uniform energy distribution |
| Warranty | 12 months for main unit |
| Brand | SYC Sycs |
|---|---|
| Origin | Shanghai, China |
| Model | SCQ-1500F |
| Ultrasonic Power | 1500 W |
| Operating Frequency | 20 kHz / 25 kHz (switchable) |
| Sample Volume Range | 0.5–1500 mL |
| Probe Tip Diameters Available | 5, 8, 10, 15, 20, 25, 30 mm |
| Timing Range | 1 s – 9 h 59 min 59 s |
| Temperature Control | Ambient only |
| Probe (Horn) Warranty | 6 months |
| Main Unit Warranty | 1 year |
| Service | Lifetime technical support and repair |
| Brand | SYC Sycs |
|---|---|
| Origin | Shanghai, China |
| Model | SCQ-3000F |
| Ultrasonic Power | 3000 W |
| Operating Frequency | 20 / 25 kHz (switchable) |
| Sample Volume Range | 0.5–3000 mL |
| Horn Tip Diameters Available | 5, 8, 10, 15, 20, 25, 30 mm |
| Timer Range | 1 s – 9 h 59 min 59 s |
| Temperature Control | Optional heating module (600 W, ambient to 60 °C) |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | SYC Sycs |
|---|---|
| Origin | Shanghai, China |
| Model | SCQ-4000F |
| Ultrasonic Power Output | 4000 W |
| Frequency | 20 kHz or 25 kHz (user-selectable) |
| Probe Tip Diameters Available | 5, 8, 10, 15, 20, 25, 30 mm |
| Sample Volume Range | 0.5–4000 mL |
| Timer Range | 00:00:01 to 99:59:59 (hh:mm:ss) |
| Heating Function | 600 W (optional, integrated) |
| Temperature Control Range | Ambient to 99 °C (with optional heating module) |
| Warranty | 1 year for main unit |
| Brand | SYCS |
|---|---|
| Origin | Shanghai, China |
| Model | SCQ-1200F |
| Ultrasonic Power Output | 1200 W |
| Frequency | 20 kHz / 25 kHz (switchable) |
| Probe Tip Diameters Available | 5–30 mm (selectable) |
| Sample Volume Range | 0.5–1200 mL |
| Timer Range | 1 s to 9 h 59 min 59 s (programmable) |
| Warranty | 1 year (main unit), 6 months (ultrasonic probe) |