Cell Disruptor
Filter
Showing 91–120 of 202 results
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY92-II |
| Ultrasonic Frequency | 20–25 kHz with automatic frequency tracking |
| Output Power | 650 W |
| Pulse Mode | Adjustable on-time (1–99 s) and off-time (1–99 s) |
| Cycle Count | 1–99 cycles |
| Standard Probe Diameter | Φ6 mm |
| Optional Probe Diameters | Φ2, Φ3, Φ8, Φ10, Φ15 mm |
| Sample Volume Range | 0.2–500 mL |
| Duty Cycle | 1–99% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY92-IID |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 900 W |
| Pulse Mode | Adjustable On/Off duration (0.1–99 s) |
| Total Processing Time | 0.1–99 min |
| Temperature Monitoring Range | 0–99 °C |
| Standard Probe Diameter | Φ6 mm |
| Optional Probes | Φ2, Φ3, Φ8, Φ10, Φ15 mm |
| Sample Volume Capacity | 0.2–600 mL |
| Duty Cycle | 0.1–99.9% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY92-IIDN |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 900 W (touch-key continuous adjustment) |
| Pulse Mode | On-time 0.1–99.9 s / Off-time 0.1–99.9 s / Total Duration 0.1–99 min |
| Duty Cycle | 0.1–99.9% |
| Temperature Monitoring Range | 0–100 °C |
| Standard Probe Diameter | Φ6 mm |
| Optional Probes | Φ2, Φ3, Φ8, Φ10, Φ15 mm |
| Sample Volume Capacity | 0.2–600 mL |
| Input Voltage | 220/110 V, 50/60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY92-IIN |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 650 W (touch-key continuous adjustment) |
| Pulse Mode | On-time 0.1–99.9 s, Off-time 0.1–99.9 s |
| Total Operating Time | 0.1–99 min |
| Temperature Monitoring Range | 0–100 °C |
| Standard Probe Diameter | Φ6 mm |
| Optional Probes | Φ2, Φ3, Φ8, Φ10, Φ15 mm |
| Sample Volume Capacity | 0.2–500 mL |
| Duty Cycle | 1–99% |
| Power Supply | 220/110 V, 50/60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY96-II |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 150 W |
| Pulse Duty Cycle | 10–90% (adjustable) |
| Interval Duty Cycle | 10–90% (adjustable) |
| Total Operation Time | 1–99 min |
| Standard Probe Diameter | Φ6 mm |
| Optional Probe Diameters | Φ2, Φ3, Φ2–Φ15, Φ18–Φ25 mm |
| Sample Volume Range | 0.2–100 mL |
| Duty Ratio | 1–99% |
| Power Supply | 220/110 V, 50/60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY96-IIN |
| Ultrasonic Frequency | 20–25 kHz with automatic frequency tracking |
| Output Power | 150 W (touch-key adjustable, continuous) |
| Pulse Mode | Duty Cycle 0.1–99.9% |
| Sonication Time | 0.1–99.9 s |
| Interval Time | 0.1–99.9 s |
| Total Operating Time | 0.1–99 min |
| Standard Probe Diameter | Φ6 mm |
| Optional Probes | Φ2, Φ3, Φ2–Φ15, Φ18–Φ25 mm |
| Sample Volume Capacity | 0.2–100 mL |
| Input Voltage | 220/110 V, 50/60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY98-III |
| Ultrasonic Frequency | 20–25 kHz with Automatic Frequency Tracking |
| Output Power | 1200 W |
| Pulse Mode | Adjustable On-Time (1–99 s) and Off-Time (1–99 s) |
| Cycle Count | 1–99 cycles |
| Standard Probe Diameter | Φ20 mm |
| Optional Probe Diameters | Φ15, Φ22, Φ25 mm |
| Sample Volume Capacity | 50–1000 mL |
| Duty Cycle | 1–99% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY98-IIID |
| Ultrasonic Frequency | 20–25 kHz with automatic frequency tracking |
| Output Power | 1200 W |
| Pulse Mode | Adjustable on-time (0.1–99 s) and off-time (0.1–99 s) |
| Total Operating Time | 0.1–99 min |
| Temperature Monitoring Range | 0–99 °C |
| Standard Probe Diameter | Φ20 mm |
| Optional Probe Diameters | Φ15, Φ22, Φ25 mm |
| Sample Volume Capacity | 50–1000 mL |
| Duty Cycle | 0.1–99.9% |
| Power Supply | 220 V / 110 V, 50 Hz / 60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY98-IIIDN |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 1200 W (touch-key continuous adjustment) |
| Sonication Time Range | 0.1–99 s |
| Interval Time Range | 0.1–99 s |
| Total Working Time | 0.1–99 min |
| Temperature Monitoring Range | 0–100 °C |
| Standard Probe Diameter | Φ20 mm |
| Optional Probe Diameters | Φ15, Φ22, Φ25 mm |
| Sample Volume Capacity | 50–1000 mL |
| Duty Cycle | 0.1–99.9% |
| Input Voltage | 220/110 V, 50/60 Hz |
| Frequency | 20–25 kHz (auto-tracking) |
|---|---|
| Power Output | 1200 W (touch-key continuous adjustment) |
| Pulse Mode | 0.1–99.9 s on / 0.1–99.9 s off |
| Total Operation Time | 0.1–99 min |
| Temperature Monitoring Range | 0–100 °C |
| Standard Probe Diameter | Φ20 mm |
| Optional Probes | Φ15, Φ22, Φ25 mm |
| Sample Volume Capacity | 50–1000 mL |
| Duty Cycle | 1–99% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY99-IID |
| Ultrasonic Frequency | 20–25 kHz with automatic frequency tracking |
| Output Power | 1800 W |
| Pulse Mode | On-time 0.1–99 s, Off-time 0.1–99 s |
| Total Operating Time | 0.1–99 min |
| Temperature Monitoring Range | 0–99 °C |
| Standard Probe Diameter | Φ25 mm |
| Optional Probe Diameters | Φ15, Φ22, Φ25, Φ28 mm |
| Sample Volume Capacity | 50–1200 mL |
| Duty Cycle | 0.1–99.9% |
| Power Supply | 220/110 V, 50/60 Hz |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY99-IIDN |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 1800 W (touch-key continuous adjustment) |
| Pulse Mode | On-time 0.1–99 s / Off-time 0.1–99 s |
| Total Operating Time | 0.1–99 min |
| Temperature Monitoring Range | 0–100 °C |
| Standard Probe Diameter | Φ25 mm |
| Optional Probes | Φ15, Φ22, Φ25, Φ28 mm |
| Sample Volume Capacity | 50–1200 mL |
| Duty Cycle | 0.1–99.9% |
| Input Voltage | 220/110 V AC, 50/60 Hz |
| Brand | JNBIO |
|---|---|
| Model | JN-10C |
| Type | High-Pressure Homogenizer (Continuous-Flow) |
| Max Operating Pressure | 207 MPa (2070 bar) |
| Flow Rate at Max Pressure | 10 L/h |
| Cooling Capacity | Integrated Chiller System |
| Ultrasonic Power Input | 1.1 kW |
| Sample Throughput | 1.5 L/h |
| Electrical Supply (Main Unit) | 380 V, 50/60 Hz, 2.25 kW |
| Electrical Supply (Chiller) | 220 V, 50/60 Hz, 1.1 kW |
| Net Dimensions (W×D×H, mm) | Host Unit: 680 × 585 × 1167 |
| Chiller Unit | 525 × 750 × 940 |
| Transport Dimensions (W×D×H, mm) | Host Unit: 750 × 750 × 1250 |
| Chiller Unit | 640 × 875 × 1125 |
| Origin | Guangdong, China |
| Regulatory Classification | CE-compliant design for laboratory use under IEC 61010-1 |
| Brand | JNBIO (Guangzhou JNBIO) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JN-2.5C |
| Instrument Type | High-Pressure Homogenizer / Cell Disruptor |
| Operating Pressure Range | 0–207 MPa (0–2070 bar) |
| Maximum Flow Rate at Max Pressure | 2.5 L/h (42 mL/min) |
| Minimum Sample Volume | 5 mL |
| Power Supply | 220 V AC |
| Main Motor | 1.5 kW, Refrigeration Compressor: 0.75 kW |
| Integrated Chilled Circulation Bath | Maintains sample path at 4–6 °C throughout feed, homogenization, and discharge stages |
| Dimensions (mm) | Host Unit: W560 × D580 × H872 |
| Chiller Unit | W525 × D635 × H870 |
| Net Weight | Host ~148 kg, Chiller ~148 kg |
| Construction | Mirror-Polished 316L Stainless Steel Fluid Path |
| Valve Material | Industrial-Grade Diamond-Coated Homogenization Valve |
| Control System | PLC-Based with 7-inch Touchscreen HMI |
| Data Logging | Real-time pressure curve, operational logs (7-day retention), alarm history (7-day retention), user-accessible audit trail |
| Compliance Features | CIP/SIP Capable, GMP-Aligned Operation Log & User Authentication, Emergency Stop, Pressure Overload Protection, Password-Protected Access Levels |
| Brand | JNBIO (Guangzhou JNBIO Biotech Co., Ltd.) |
|---|---|
| Origin | Guangdong, China |
| Model | JN-Mini Pro |
| Maximum Operating Pressure | 207 MPa (2070 bar) |
| Minimum Sample Volume | 3 mL |
| Temperature Control Range | 4–6 °C (integrated recirculating chiller required) |
| Flow Path Materials | 316L stainless steel |
| Disruption Valve | Diamond-coated |
| Drive System | Hydraulic |
| In-line CIP/SIP Capability | Yes |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Product Origin | Domestic (China) |
| Model | JY92-IIN |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 650 W |
| Operating Frequency | 22 kHz |
| Temperature Range | Ambient |
| Sample Volume | 0.5–600 mL |
| Sample Capacity | Single-sample processing |
| Duty Cycle | 0.1–99.9% |
| Input Voltage | 220 V / 110 V AC |
| Standard Probe | Φ6 mm titanium alloy horn |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-700 Series |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 40,000 psi |
| Max Flow Rate | 15.6 L/min |
| Inlet Temperature Range | Up to 75 °C |
| Power Supply | 3-Phase, 380 V, 15–50 HP |
| Air Supply | 50–150 psi, 1 SCFM @ 50 psi, Dew Point: 0–35 °F |
| Dimensions | 74 × 180 × 145 cm |
| Weight | 675–900 kg |
| Chamber Material | Diamond-Embedded Stainless Steel |
| Construction | Fully 316L Stainless Steel |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-110Y |
| Instrument Type | High-Pressure Cell Disruptor |
| Operating Pressure Range | 3,000–23,000 psi |
| Max. Flow Rate | 250–600 mL/min |
| Feed Temperature Range | –25°C to +75°C |
| Minimum Sample Volume | 14 mL |
| Compressed Air Requirement | 57 scfm at 120 psi, 15 hp (11 kW) |
| Dimensions | 28 × 41 × 76 cm |
| Weight | 25 kg |
| Interaction Chamber Material | Diamond or Ceramic |
| Wetted Parts | 300-series Stainless Steel (Chromium-Plated Piston) |
| Integrated Cooling Coil | 17 ft (13 mL volume) |
| Cleaning | CIP-capable (Clean-in-Place) |
| Certification | Explosion-Proof & Portable Design |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-110EH |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 30,000 psi (207 MPa) |
| Max Flow Rate | 450 mL/min |
| Inlet Temp. Range | ≤75°C |
| Power Supply | 3-Phase, 380 V, 5 HP (3.7 kW) |
| Fluid Path Volume | 100 mL |
| Compressed Air Requirement | 35–150 psi |
| Dew Point | 0–35°F |
| Minimum Sample Volume | 120 mL |
| Dimensions | 73 × 87 × 148 cm |
| Weight | 205 kg |
| IXC Chamber Material | Synthetic Diamond |
| Regulatory Compliance | CE Certified |
| Cleaning | CIP-Compatible |
| Sterilization | SIP-Capable (Steam or Hot Water) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HC-8000 |
| Price Range | USD $14,000–$70,000 |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 1,000–8,000 psi |
| Max Flow Rate | 1,000 mL/min |
| Feed Temperature Limit | 75 °C |
| Compressed Air Requirement | 57 SCFM at 50 psi, dew point −17.7 to 1.6 °C, 15 hp (11 kW) |
| Minimum Sample Volume | 250 mL |
| Dimensions | 58 × 38 × 58 cm |
| Weight | 26.7 kg |
| Construction Material | Electropolished 316 Stainless Steel |
| Cleaning | CIP-capable high-pressure fluid path |
| Drive Mechanism | Pneumatic, explosion-proof |
| Sterilization Compliance | Autoclavable and SIP-compatible components |
| Brand | Misonix |
|---|---|
| Origin | USA |
| Model | Sonicator 4000 |
| Output Power | 600 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 0.1–4000 mL |
| Pulse Duration Adjustable | 1 s–24 hr |
| Continuous Operation Capability | 72 hr |
| Dimensions (W × D × H) | 27.9 × 50.8 × 13.9 cm |
| Weight | 12.0 kg |
| Probe Types | Tapped & Stepped, Diameter Range: 1.6–25.4 mm |
| Control Interface | Full Digital Touchscreen |
| Compliance | Designed for GLP/GMP-adjacent workflows, supports audit-ready operation with optional temperature probe (TP4000) |
| Brand | Misonix |
|---|---|
| Origin | USA |
| Model | XL2000 |
| Maximum Output Power | 100 W |
| Operating Frequency | 22.5 kHz |
| Sample Volume Range | 0.2–50 mL |
| Dimensions (W × D × H) | 19.0 × 33.0 × 17.8 cm |
| Weight | 4.1 kg |
| Display | LCD Digital Interface |
| Operating Modes | Continuous & Pulse |
| Probe Options | P-1 (1/8″, 0.5–15 mL), P-2 (3/16″, 2–25 mL), P-3 (3/32″, 0.2–5 mL), P-4 (1/4″, 5–50 mL) |
| Optional Accessories | Acoustic Enclosure, Cup Horn (Non-contact Sonication) |
| Brand | New Chi / SCIENTZ |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-4TDL |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Output Power | 2400 W |
| Sample Volume per Channel | 0.5–15 mL |
| Number of Simultaneous Channels | 4 |
| Cooling Compatibility | Ice-bath or pre-chilled adapter (1.5–2 mL × 4 wells) |
| Control Mode | Programmable pulsed/continuous operation |
| Memory Capacity | Up to 50 user-defined protocols |
| Safety Features | Real-time temperature monitoring, overload protection, auto-diagnostic error reporting |
| Compliance | Designed for GLP-compliant labs |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DNU-8020 |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Operating Frequency | 35–40 kHz |
| Ultrasonic Power Output | 50 W |
| Sample Volume per Tube | 2 mL |
| Maximum Simultaneous Samples | 8 |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | JY88-PRO |
| Temperature Range | 0–99.9 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 4.5–450 W |
| Sample Volume Capacity | 10–200 mL |
| Sample Throughput | Single-sample mode |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1200 W |
| Operating Frequency | 19.5–20.5 kHz |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 50–1000 mL |
| Sample Throughput | Single-sample processing |
| Transducer Material | Titanium Alloy Probe |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1800 W |
| Operating Frequency | 19.5–20.5 kHz |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 50–1200 mL |
| Sample Throughput | Single-sample processing per cycle |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1800 W |
| Operating Frequency | 40 kHz |
| Sample Volume Capacity | 1.5 L (total) |
| Throughput | 8 or 16 samples per run |
| Cooling Interface | Integrated recirculating chiller port (4–10 °C operational range) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | SCIENTZ-08-II |
| Instrument Type | Non-contact ultrasonic cell disruptor (cup-horn system) |
| Operating Frequency | 40 kHz |
| Adjustable Ultrasonic Power | 1800 W |
| Sample Volume Range | 5 µL – 15 mL |
| Sample Capacity | 1–16 tubes |
| Power Adjustment Range | 1–99% |
| Timer Range | 1–999 min |
| Duty Cycle | 0.1–99.9% |
| Tank Volume | 1.5 L |
| Compatible Vessel Formats | 1–2 mL × 16 wells, 5 mL × 8 wells, 10–15 mL × 8 wells |
| Temperature Monitoring | Yes |
| Input Voltage | 220/110 V ±0.5%, 50/60 Hz |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 2200 W |
| Operating Frequency | 40 kHz |
| Sample Volume Capacity | 1–2 mL, 5 mL, or 10–15 mL per tube |
| Throughput | 17, 20, or 32 samples per run |
| Cooling System | Integrated recirculating chiller-compatible jacket (operating range: 4–10 °C) |
| Sample Container Compatibility | Standard microcentrifuge tubes (1.5/2.0 mL), PCR strips, and custom cryovials |
| Control Interface | Digital touchscreen with programmable protocols (time, amplitude, pulse mode, cycle count) |
| Safety Certification | CE-compliant design |