Cell Disruptor
Filter
Showing 31–60 of 202 results
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-4SKII |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 18–1800 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Number of Simultaneous Samples | 4 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Auto-compensated under variable load |
| Data Storage Capacity | 20 user-defined protocols |
| Display | 7-inch TFT capacitive touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Safety Protections | Overtemperature, over-power, and overtime cutoffs |
| Communication Interface | RS-232 or USB (optional) |
| Footswitch Support | Optional |
| Cryogenic Compatibility | Integrated Peltier-cooled sample rack with external chiller port |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-8S |
| Ultrasonic Power | 20–2000 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Number of Simultaneous Samples | 8 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic Load-Compensated |
| Data Storage | 20 Preset Protocols |
| Display | 7-inch TFT Touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz |
| Safety Protections | Overtemperature, Overpower, Overtime |
| Brand | Daxluot |
|---|---|
| Model | Dxluot-4SKI |
| Origin | Shanghai, China |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 12–1200 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Sample Volume per Channel | 1–10 mL |
| Number of Simultaneous Samples | 4 |
| Temperature Control Range | −5 to 100 °C |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic load-compensated |
| Programmable Parameters | 20 user-defined protocols |
| Ultrasound On/Off Time | 0.1–99.9 s (adjustable) |
| Total Cycle Duration | 0.1 s – 99 h 59 min 59 s |
| Safety Protections | Overtemperature, Overpower, Overtime |
| Display | 7-inch TFT capacitive touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Communication Interface | RS-232 or USB (optional) |
| Footswitch Support | Optional |
| Data Logging | Timestamped protocol execution history |
| Cooling Integration | Integrated Peltier-assisted cold block with recirculating thermal management |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | DLT-2400 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Power Output | 2400 W (continuously adjustable from 1% to 100%) |
| Sample Volume Capacity | 500–2000 mL |
| Temperature Control Range | 0–99.9 °C |
| Duty Cycle Adjustment | 0.1–99.9% |
| Display | 7-inch TFT capacitive touchscreen |
| Probe Material | TC4 titanium alloy |
| Standard Horn Diameter | Φ25 mm (optional horns: Φ3, 6, 10, 15, 20, 22, 25, 28 mm) |
| Safety Features | Overcurrent, overvoltage, overtemperature, and timer fault protection |
| Cooling | Integrated NTC thermistor-based sample temperature monitoring |
| Configuration | Separated main unit + acoustic isolation chamber with motorized lift stage and LED illumination |
| Optional Upgrades | UV sterilization module |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | Bioruptor Pico |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 300 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 4 °C to ambient |
| Sample Volume | 5 µL – 2 mL |
| Maximum Sample Capacity | 18 tubes (depending on adapter) |
| Cooling System | Integrated electromagnetic valve-controlled recirculating chiller |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | Pico |
| Ultrasonic Power | 25–210 W |
| Operating Frequency | 20–60 kHz |
| Temperature Range | −20 °C to 40 °C |
| Sample Volume Capacity | 5 µL – 12 mL (dependent on adapter selection) |
| Maximum Simultaneous Samples | 12 |
| Cooling System | Integrated solenoid-valve-controlled recirculating chiller |
| Fragment Size Range (DNA) | 100 bp – 1 kb |
| Adapter Standard | 0.5 mL tube holder with mechanical locking mechanism |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | Bioruptor Plus |
| Instrument Type | Non-contact ultrasonic cell disruptor |
| Sample Capacity | 6–12 tubes (0.5 mL to 50 mL) |
| Cooling | Integrated 4 °C water bath with optional recirculating chiller |
| Control Interface | Digital LCD timer & power selector (Low/High) |
| Safety | Fully sealed tube processing, acoustic shielding enclosure, overheat protection |
| Compliance | Designed for GLP-compliant chromatin shearing and DNA fragmentation workflows per EN ISO 13485-aligned manufacturing standards |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | UCD-300 (Plus) |
| Instrument Type | Non-contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 160–320 W |
| Operating Frequency | 40 kHz (typical, fixed-frequency transducer array) |
| Temperature Range | −20 °C to +40 °C (with optional chiller integration) |
| Sample Volume Capacity | 5 µL – 20 mL (dependent on adapter configuration) |
| Throughput | 1–12 samples per run (6–12 standard with rotating rack |
| Cooling Method | External recirculating chiller or integrated Peltier-assisted bath temperature control |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | Bioruptor Plus |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 400–700 W |
| Operating Frequency | 20 kHz |
| Temperature Control | Ambient (with optional water-cooling system) |
| Sample Volume Range | 5 µL – 20 mL |
| Maximum Parallel Samples | 12 |
| Compatible Tube Formats | 0.5 mL, 1.5 mL, 15 mL, 50 mL centrifuge tubes |
| Safety | Closed-tube, non-contact, aerosol-free operation |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO/IEC 17025 laboratory practices |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | new pico |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 300 W |
| Operating Frequency | 40 kHz |
| Temperature Range | 4 °C to ambient |
| Maximum Sample Capacity | 16 tubes |
| Sample Volume Range | 20 µL – 2 mL |
| Cooling System | Integrated solenoid-valve-controlled recirculating chiller |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | UCD300 |
| Operating Frequency | 20 kHz |
| Ultrasonic Power Output | 155 W / 310 W (dual-step adjustable) |
| Sample Volume Range | 5 µL – 20 mL |
| Maximum Throughput | ≥24 samples per run |
| Processing Chamber Volume | 750 mL |
| Dimensions (Controller) | 150 × 300 × 195 mm (W×D×H) |
| Dimensions (Processing Chamber) | 350 × 260 × 150 mm (W×D×H) |
| Weight | 20 kg |
| Timer Range | 0–60 sec or 0–15 min (on/off cycles) |
| Compatible Vessels | PCR tubes, 1.5 mL, 10 mL, 15 mL, and 50 mL centrifuge tubes |
| Fragmentation Range (DNA) | 2 kb – <500 bp |
| Rotation Speed | Programmable constant-speed rotation during sonication |
| Compliance | CE-marked |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MX-C |
| Instrument Type | Vortex-Based Mechanical Cell Disruptor |
| Sample Throughput | 8 × 2 mL Tubes |
| Motion Mode | High-Speed Orbital Vortexing & Oscillation |
| Orbit Diameter | 4 mm |
| Speed Range | 0–3000 rpm (Adjustable) |
| Speed Display | Analog Scale |
| Power Input | 60 W |
| Voltage | 100–120 V / 200–240 V AC |
| Frequency | 50/60 Hz |
| Dimensions (L × W × H) | 127 × 130 × 160 mm |
| Weight | 2.0 kg |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Model | MX-C |
| Temperature Range | 0–60 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 0–300 W |
| Sample Volume per Tube | 0.5–50 mL |
| Throughput | 8 samples (max. 2 mL/tube) |
| Vortex Motion | Orbital shaking with 4 mm orbit diameter |
| Speed Range | 0–3000 rpm (adjustable) |
| Power Input | 60 W |
| Voltage | 100–120 V / 200–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 127 × 130 × 160 mm |
| Weight | 2.0 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GM11 |
| Price Range | USD 14,000 – 72,000 |
| Instrument Type | High-Pressure Cell Disrupter |
| Ultrasonic Power | 2000 W |
| Operating Frequency | 50 Hz |
| Temperature Range | 0 °C to Ambient |
| Sample Volume | 3500 mL |
| Throughput | Single-batch processing |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Hannuo-1200EW |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | Ambient to 90 °C |
| Sample Volume Capacity | 10–1000 mL (with interchangeable probes) |
| Probe Standard | Φ20 mm titanium alloy horn |
| Optional Probes | Φ10, Φ15, Φ22 mm |
| Pulse Mode | 0.1–99.9 s on/off adjustable |
| Duty Cycle | 0.1–99.9% |
| Control Interface | 7-inch TFT touch screen |
| Data Storage | 20 user-defined protocols |
| PC Connectivity | RS232/USB interface with data export & remote control capability |
| Safety Features | Overtemperature, overload, no-load, and time-out alarms |
| Power Supply | 220 V ±5%, 50 Hz (110 V option available) |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Model | Hannuo-950EW |
| Ultrasonic Power | 950 W |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | Ambient to 90 °C |
| Sample Volume Capacity | 0.2–700 mL (with interchangeable probes) |
| Probe Diameter (Standard) | Φ6 mm |
| Pulse Mode | 0.1–99.9 s ON/OFF adjustable |
| Duty Cycle | 0.1–99.9% |
| Power Adjustment Range | 1–99% (10–950 W) |
| Display | 7-inch TFT touch screen |
| Data Storage | 20 user protocols |
| Communication Interface | RS-232/USB for PC connectivity |
| Safety Features | Overtemperature, overload, no-load, and self-diagnostic alarms |
| Optional Accessories | Cryogenic cooling module, motorized probe lift, acoustic isolation chamber |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-1500 |
| Ultrasonic Output Power | 1500 W |
| Operating Frequency | 22 kHz (auto-frequency tracking) |
| Temperature Control Range | 0–99 °C (optional extended range: −5 to 100 °C with chiller) |
| Sample Volume Capacity | 600 mL |
| Maximum Sample Load | 1 vessel |
| Pulse Mode Interval | 0.1–99.9 s adjustable |
| Total Processing Time | up to 99 h 59 min 59 s |
| Display | 4.3″ TFT touchscreen |
| Data Storage | 20 programmable protocols |
| Probe Material | Titanium alloy (Ti-6Al-4V) |
| Input Power | AC 220 V ±5%, 50 Hz |
| Compliance | CE-marked design principles |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN-2000 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Output Power | 2000 W |
| Operating Frequency | 20 kHz (auto-frequency tracking) |
| Temperature Control Range | −5 °C to 100 °C |
| Maximum Sample Volume | 2000 mL |
| Sample Capacity | Single-vessel processing |
| Control Interface | 4.3″ TFT Touchscreen |
| Programmable Memory | 20 Presets |
| Pulse Mode Interval | 0.1–99.9 s adjustable |
| Continuous/Pulse Operation Mode | Selectable |
| Probe Material | Ti-6Al-4V Titanium Alloy |
| Cooling Compatibility | Integrated interface for external recirculating chiller |
| Safety Features | Over-temperature, over-load, and fault auto-detection with audible/visual alerts |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN98-IIIB |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 3500 W |
| Operating Frequency | 19–30 kHz |
| Temperature Range | −5 °C to 100 °C (expandable with external chiller) |
| Sample Volume per Tube | 0.1–2 mL |
| Parallel Sample Capacity | 4–32 tubes |
| Display & Control | Touchscreen Interface |
| Communication Options | RS232/RS485 port (optional) |
| Cooling Interface | Integrated water-circulation coupling port (chiller compatible) |
| Duty Cycle | 1–99.9% adjustable |
| Power Supply | 220 V / 110 V, 50 Hz / 60 Hz |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | Dalxuot-300M |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 28–30 kHz |
| Ultrasonic Power Output | 30–300 W (adjustable) |
| Sample Volume Capacity | 0.1–300 mL |
| Sample Throughput | Single-sample processing |
| Input Power | 100–230 V AC, 50–60 Hz or 12–24 V DC |
| Weight | 0.5 kg |
| Dimensions (L×W) | 300 × 43 mm |
| Transducer Material | 7075 Aluminum Alloy |
| Horn Material | TC4 Titanium Alloy |
| Housing Material | ABS + Flame-Retardant Additive |
| Operating Temperature | 5–30 °C |
| Relative Humidity | ≤70% RH |
| Standard Probe Diameter | Ø6 mm |
| Optional Probes | Ø2 mm (0.1–5 mL), Ø6 mm (5–100 mL), Ø8 mm (50–300 mL) |
| Continuous Sonication Duration | <40 min |
| Control Mode | Manual push-button activation (momentary contact) |
| Display | DC input voltage only |
| Optional Accessory | Adjustable transducer support stand (300 × 225 × 320 mm) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-400 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 4–400 W (adjustable in 1% increments) |
| Operating Frequency | 19–25 kHz |
| Temperature Range | Ambient to 90 °C (optional low-temperature circulator support up to 100 °C) |
| Sample Volume Capacity | 0.1–300 mL (dependent on horn probe selection) |
| Probe Options | Φ2, Φ3, Φ5, Φ6, Φ8 mm titanium alloy horns |
| Display | 4.3-inch true-color capacitive touchscreen |
| Control System | Embedded microcontroller with TFT touch interface |
| Data Storage | 20 programmable protocols |
| Safety Features | Overload, no-load, overtemperature, and time-out alarms |
| Power Supply | 220 V / 110 V, 50 / 60 Hz |
| Optional Accessories | Cooling jacket, acoustic isolation chamber, foot switch, RS232/USB data export, thermal printer |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | Hannuo-6000 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Output Power | 6000 W |
| Operating Frequency | 19 kHz (frequency-tracking) |
| Sample Volume Capacity | 5 L (continuous flow) |
| Temperature Control Range | 0–100 °C |
| Pulse Duration | 0.1–99.9 s (ultrasonic/on–off interval) |
| Total Process Time | 0–99 h 59 min 59 s |
| Display | 4.3-inch TFT touchscreen |
| Protection | Overload, overtemperature, and fault auto-detection |
| Power Supply | AC 220 V ±5%, 50 Hz (110 V optional) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-1000 |
| Ultrasonic Output Power | 1000 W |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | –5 °C to 100 °C (with optional chiller) |
| Maximum Sample Volume | 1000 mL |
| Pulse Mode Interval | 0.1–99.9 s adjustable |
| Total Processing Time | 0–99 h 59 min 59 s |
| Programmable Memory | 20 user-defined protocols |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Touchscreen Interface | 4.3″ TFT LCD |
| Input Voltage | AC 220 V ±5%, 50 Hz |
| Compliance | CE-marked design principles |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-1000CS |
| Ultrasonic Power | 1000 W (adjustable 10–1000 W) |
| Operating Frequency | 20 kHz (±0.5 kHz) |
| Temperature Range | Ambient to 90 °C (optional external chiller or Peltier module for −20 to 100 °C control) |
| Maximum Sample Volume | 1000 mL |
| Display | 7-inch capacitive TFT touchscreen |
| Ultrasonic Pulse Duration | 0.1–99.9 s |
| Interval Time | 0.1–99.9 s |
| Total Process Time | Up to 99 h 59 min 59 s |
| Data Storage | 20 programmable protocols |
| Communication Interfaces | RS232 and RS485 |
| Probe Material | Titanium alloy (Grade 5) |
| Standard Horn | Φ6 mm |
| Optional Horns | Φ2, Φ3, Φ10, Φ12, Φ15 mm |
| Safety Alarms | Overtemperature, overcurrent, no-load, overload, time-out |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-1000D |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 50–1000 W (continuously adjustable) |
| Operating Frequency | 20–30 kHz (auto-tuned, LCD-displayed) |
| Temperature Control Range | −5 to 100 °C (optional −120 to 300 °C) |
| Sample Volume Capacity | 50–600 mL (glass double-jacketed reactors: 50 / 100 / 250 / 500 mL) |
| Stirring Speed | 0–2400 rpm (magnetic, continuously adjustable) |
| Horn Diameter | Φ10 mm or Φ12 mm (titanium alloy, immersion-type) |
| Pulse Mode | Independent on/off control, adjustable pulse duration and automatic pulse counting |
| Sealing Interface | Standard ground-glass joints (e.g., 24/24, 50/50), custom configurations available |
| Cooling/Heating Medium | Circulating water or thermal oil via jacket |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN-1000Y |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1000 W |
| Operating Frequency | 22 kHz |
| Temperature Range | 0–99 °C |
| Sample Volume Capacity | 1000 mL |
| Sample Throughput | Single-sample operation |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN-1200Y |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1000 W (adjustable 1–100% duty cycle) |
| Operating Frequency Range | 19–23 kHz |
| Temperature Control Range | −5 °C to +100 °C |
| Maximum Sample Volume | 1000 mL |
| Single-Sample Processing Capacity | 1 unit per cycle |
| Standard Probe Diameter | Φ20 mm |
| Optional Probes | Φ10 mm, Φ15 mm, Φ22 mm |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-150Y |
| Ultrasonic Power | 150 W |
| Operating Frequency | 25 kHz |
| Temperature Range | Ambient to 90 °C |
| Sample Volume Capacity | 150 mL |
| Number of Samples per Run | 1 |
| Display | LCD |
| Programmable Protocols | 50 memory slots |
| Power Adjustment Range | 1–99% (5–150 W) |
| Standard Probe Diameter | Φ6 mm |
| Optional Probe Diameters | Φ2 mm, Φ3 mm |
| Temperature Protection Limit | Up to 99 °C |
| Automatic Power Tracking & Fault Alarm | Yes |
| Real-time Power Monitoring | Yes |
| Integrated Temperature Control | Yes |
| Brand | Hanuo |
|---|---|
| Model | HN-2500 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Output Power | 2500 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Sample Volume Capacity | 1000 mL |
| Temperature Control Range | Ambient to 90 °C (optional extended range: −5 °C to 100 °C with chiller) |
| Pulse Mode Interval | 0.1–99.9 s (adjustable) |
| Total Processing Time | 0–99 h 59 min 59 s |
| Data Storage | 20 programmable protocols |
| Probe Material | Ti-6Al-4V titanium alloy |
| Input Voltage | AC 220 V ±5%, 50 Hz |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Daxluot-250 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 2.5–250 W (adjustable in 1% increments) |
| Operating Frequency | 20–30 kHz (frequency-tracking microprocessor control) |
| Temperature Monitoring Range | 0–100 °C (with real-time digital display) |
| Sample Volume Capacity | 0.1–150 mL (dependent on horn probe selection) |
| Probe Options | Standard Φ3 mm or Φ5 mm titanium alloy horn |
| Display | 4.3-inch full-color capacitive TFT touchscreen |
| Sonication Time per Cycle | 0.1–99.9 s |
| Interval Time per Cycle | 0.1–99.9 s |
| Total Process Duration | Up to 99 h 59 min 59 s |
| Safety Alarms | Over-temperature, overload, no-load, and time-out |
| Data Storage | 20 programmable protocols |
| Power Supply | 220 V / 110 V, 50 / 60 Hz |
| Compliance | CE-marked design architecture |