| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1800 W |
| Operating Frequency | 20 kHz (±0.5 kHz) |
| Sample Volume Capacity | 900 mL |
| Sample Throughput | 1 tube per cycle (rotating holder supports single-tube continuous rotation) |
| Temperature Control | Integrated jacketed cup with external chiller compatibility (4–10 °C typical operational range) |
| Cooling Interface | Dual-layer borosilicate glass cup with external recirculating coolant port |
| Minimum Sample Volume | 5 µL |
| Acoustic Isolation | Built-in acoustic enclosure with transparent viewing window |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-1000J |
| Temperature Range | 0–99.9 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 1000 W (adjustable in 1% increments) |
| Duty Cycle | 0.1–99.9% |
| Sample Volume Capacity | 10–200 mL |
| Alarm Functions | Overtemperature, Overload, and Timer Alert |
| Transducer Material | TC4 Titanium Alloy (Grade 5 Ti-6Al-4V) |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Range | 50–1200 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking & adaptive) |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 50–1200 mL |
| Multi-sample Processing Capability | Yes |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-16TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Power Output | 2400 W |
| Sample Volume per Tube | 1–20 mL |
| Parallel Processing Capacity | 16 samples |
| Cooling Mode | Integrated temperature-controlled rack (ambient to ~15 °C recommended) |
| Pulse Mode | Adjustable on/off duty cycle |
| Protection Features | Overtemperature, overload, and system self-diagnosis |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-24TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Total Ultrasonic Output Power | 2400 W |
| Sample Volume per Tube | 100 µL – 5 mL |
| Parallel Processing Capacity | 24 samples |
| Cooling Method | Integrated Temperature-Controlled Rack (External Chiller Interface Supported) |
| Pulse Mode | Adjustable Duty Cycle (Continuous / Intermittent) |
| Programmable Protocols | Up to 20 user-defined methods |
| Safety Features | Overtemperature & Overload Protection, Real-time System Diagnostics |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-48TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Maximum Ultrasonic Power | 2400 W |
| Sample Volume per Tube | 100 µL – 4 mL |
| Parallel Processing Capacity | 48 Samples |
| Temperature Control | Not Specified (External Cooling Required) |
| Pulse Mode | Adjustable Continuous or Duty-Cycle Mode |
| Programmable Protocols | Up to 20 User-Defined Methods |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-4TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Output Power | 2400 W |
| Sample Volume per Channel | 1–20 mL |
| Number of Simultaneous Samples | 4 |
| Cooling Method | Integrated Temperature-Controlled Jacket (External Circulator Required) |
| Pulse Mode | Adjustable Continuous or Intermittent (Duty Cycle Programmable) |
| Control Interface | Touchscreen with Onboard Memory for Up to 20 User-Defined Protocols |
| Safety Features | Real-time Overtemperature & Overload Detection, Auto-Shutdown, Fault Diagnostics |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Range | 5–650 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking & adaptive) |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 100 µL–500 mL |
| Multi-sample Processing Capability | Yes |
| Safety Features | Overtemperature, overload, and time-out alarms |
| Control Interface | Remote network connectivity (Ethernet/RS232) |
| Design | Stackable benchtop configuration with transparent front access panel and internal LED illumination |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-650J |
| Design | Integrated Benchtop System |
| Transducer Material | TC4 Titanium Alloy (Grade 5 Ti-6Al-4V) |
| Power Adjustment | 1–100% in 1% increments |
| Time Resolution | 0.1 s (ultrasonication & interval) |
| Operating Modes | Continuous & Pulse (duty cycle programmable) |
| Safety Features | Overload, overtemperature, and timeout alarms |
| Acoustic Enclosure | Multi-layer acoustic damping panels (STC-rated) |
| Control Interface | Programmable digital controller with remote lift actuation |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-650L |
| Cooling | Built-in Refrigeration System |
| Power Adjustment | 1–100% in 1% increments |
| Time Resolution | 0.1 s (ultrasonication & interval) |
| Operating Modes | Continuous & Pulse (with test mode) |
| Safety Protections | Overload, overtemperature, and time-out alarms |
| Horn Material | TC4 Titanium Alloy (Grade 5, ASTM B348) |
| Acoustic Enclosure | Integrated 3D Sound-Dampening Chamber |
| Control | Motorized Vertical Lift with Remote Handheld Controller |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-6TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Output Power | 2400 W |
| Sample Volume per Tube | 1–50 mL |
| Number of Simultaneous Samples | 6 |
| Cooling Method | Integrated Temperature-Controlled Jacket (External Circulator Required) |
| Pulse Mode | Adjustable Continuous or Intermittent (Duty Cycle Programmable) |
| Control Interface | Touchscreen with Embedded Microprocessor |
| Program Storage | Up to 20 User-Defined Protocols |
| Safety Features | Real-Time Overtemperature & Overload Monitoring, Auto-Shutdown, Fault Diagnostics |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-8TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Output Power | 2400 W |
| Sample Volume per Tube | 1–20 mL |
| Parallel Channels | 8 |
| Cooling Mode | Integrated Temperature-Controlled Jacket (External Circulator Required) |
| Control Interface | Touchscreen with Programmable Protocol Storage (20 Presets) |
| Pulse Mode | Adjustable Duty Cycle (Continuous / Intermittent) |
| Safety Features | Overtemperature & Overload Protection, Real-Time System Diagnostics |
| Compliance | Designed to Support GLP/GMP-Compliant Workflows (Audit Trail Ready via Optional Software) |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Range | 5–950 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking & self-adaptive) |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 100 µL–600 mL |
| Multi-sample Processing Capability | Yes |
| Safety Features | Overtemperature, overload, and time-out alarms |
| Control Interface | Remote network control (RS485/Ethernet) |
| Mechanical Design | Motorized vertical lift stage |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-96TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Total Ultrasonic Output Power | 2400 W |
| Sample Volume per Well | 100 µL – 0.5 mL |
| Parallel Processing Capacity | 96 samples |
| Cooling Method | Integrated Peltier-based temperature control (operating range: 0–40 °C, programmable) |
| Pulse Mode | Adjustable on/off duty cycle (continuous or pulsed) |
| Power Regulation | 1–100% stepless digital control |
| Data Logging | Timestamped operation records with parameter traceability |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Scientz-IID |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–99.9 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 20–1000 W |
| Sample Volume Capacity | 100 μL to 600 mL |
| Sample Throughput | Single-sample processing per cycle |
| Transducer Material | Titanium Alloy |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | SCINETZ-08 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 2400 W |
| Operating Frequency | 15 kHz |
| Batch Sample Volume | 1–5 L per cycle |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Model | Q125 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Maximum Output Power | 125 W |
| Operating Frequency | 20 kHz |
| Adjustable Pulse Duration | 1 s – 60 s |
| Sample Volume Range | 0.2–50 mL |
| Dimensions (W × D × H) | 20.3 × 35 × 14.6 cm |
| Standard Probe | 1/8" (3.2 mm) tapered microtip |
| Optional Accessories | Non-contact cup horn (Cat. #4608), 8-position probe holder (Cat. #4602), Acoustic Enclosure (Cat. #432A) |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Model | Q125 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 125 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 1–121 °C |
| Sample Volume Capacity | 5 µL – 100 mL |
| Number of Samples per Run | 1 |
| Pulse Duration Adjustment | 1 s – 60 s |
| Continuous Operation Limit | Up to 10 hours |
| Dimensions (W×D×H) | 20 × 35 × 15 cm |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Model | Q2000 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 2000 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 0–120 °C |
| Maximum Batch Sample Volume | 5 L |
| Flow-Through Capability | Yes (with Flocell chamber) |
| Amplitude Adjustment Range | 20–100% |
| Pulse Mode | Adjustable (1 s–1 min on/off cycles) |
| Continuous Operation Time | 1 s–10 hr |
| Dimensions (H × W × D) | 178 × 380 × 463 mm |
| Standard Probe | 4677 (1/2″ diameter) |
| Optional High-Capacity Probe | 4777 (1.5″ / 38 mm diameter, 25.4 cm length, 100 µm amplitude) |
| Flow Cell | Flocell with 1/2″ NPT ports, optional water-jacketed cooling and acoustic enclosure |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Model | Q500 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 500 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 1–121 °C |
| Sample Volume Capacity | 5 µL – 1000 mL (batch) / 0.5–20 L/min (flow-through) |
| Throughput | 1–384 samples per run |
| Pulse Duration Adjustment | 1 s – 1 min |
| Continuous Operation Limit | 10 hr |
| Probe Amplitude Range | 30–320 µm (model-dependent) |
| Standard Probe Diameter Options | 1.6 mm, 3.2 mm, 6.4 mm, 12.7 mm, 19.1 mm, 25.4 mm |
| Probe Types | Replaceable-tip, Solid-tapered, High-amplitude, Flow-through, and Cup-horn configurations |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Q500 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Maximum Output Power | 500 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 0.1–1000 mL (up to 0.5 L/min with flow cell) |
| Dimensions (W × D × H) | 20.3 × 38.7 × 22 cm |
| Continuous Operation Time | Up to 10 hr |
| Adjustable Pulse Duration | 1 s – 1 min |
| Amplitude Range | 20–100% (120 µm nominal at 1/2″ probe) |
| Display | Digital real-time readout of time, power, and energy |
| Safety | Integrated overload protection |
| Remote Control | Footswitch-compatible |
| Standard Kit | Host unit, transducer, 1/2″ tapered probe (part #4220), wrench set |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Model | Q55 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Maximum Output Power | 55 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 0.2–50 mL |
| Dimensions (W × D × H) | 20.3 × 19.0 × 14.6 cm |
| Standard Probe | 1/8" (3.2 mm) tapered microtip |
| Optional Probes | 4423 (0.2–5 mL, 2 mm, 200 µm amplitude), 4422 (0.5–15 mL, 3.2 mm, 180 µm), 4435 (5–50 mL, 6.4 mm, 120 µm) |
| Optional Accessory | 432A Acoustic Enclosure (50.8 × 30.5 × 30.5 cm) |
| Brand | Qsonica LLC |
|---|---|
| Country of Origin | USA |
| Model | Q700 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 700 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 1–121 °C |
| Sample Volume Capacity | 5 µL – 1000 L (via flow cell or microtip) |
| Throughput | 1–384 samples per run |
| Compliance | UL, CE, CSA, RoHS |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Q700 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Maximum Output Power | 700 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 0.1–1000 mL (batch) |
| Dimensions (W × D × H) | 20.3 × 38.7 × 22 cm |
| Programmable Memory Slots | 10 |
| Continuous Operation Time | Up to 72 hr |
| Pulse Duration Range | 1 s – 24 hr |
| Display | Full-color capacitive touchscreen |
| Temperature Monitoring | Real-time probe temperature sensing with thermal protection |
| Amplitude Control Range | 0–100% (digitally regulated, probe-specific calibration) |
| Brand | Qsonica LLC |
|---|---|
| Origin | USA |
| Model | Q800R3 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 750 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 2–45 °C |
| Sample Volume per Tube | < 50 µL |
| Maximum Sample Capacity | 36 tubes |
| Compatible Adapters | 8 × 1.5 mL, 12 × 0.5 mL, 18 × 0.2 mL |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | CFU-3000W |
| Operating Frequency | 20 kHz ± 1 kHz |
| Ultrasonic Power Output | 750 W |
| Sample Throughput | 5–50 L/h |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Continuous-Flow Ultrasonic Cell Disruptor |
| Operating Frequency | 20 kHz ± 1 kHz |
| Ultrasonic Power Output | 750 W |
| Flow Rate Capacity | 5–50 L/h |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Continuous-Flow Ultrasonic Cell Disruptor |
| Operating Frequency | 20 kHz ± 1 kHz |
| Ultrasonic Power Output | 750 W |
| Flow Rate Capacity | 5–50 L/h |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | CFU-750W-M1 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 20 kHz ± 1 kHz |
| Ultrasonic Power Output | 750 W |
| Temperature Control Range | −30 °C to 100 °C |
| Sample Throughput | 1–50 L/h |
| Reactor Material | SUS316 Stainless Steel |
| Transducer & Horn Material | Titanium Alloy (Grade 5) |
| Control Interface | 10-inch Capacitive Touchscreen |
| Data Logging | Internal storage with USB export |
| Communication Protocol | Modbus-TCP over RJ45 Ethernet |
| User Access Control | Three-tier permission system (Admin / Operator / Guest) |
| Sterilization Compatibility | In-situ steam sterilization (SIP) or offline autoclaving (121 °C, 2 bar, 30 min) |
| Cooling Architecture | Double-jacketed reactor with external chiller integration (e.g., DC-3006) |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | CFU-750W-M1 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 20 kHz ± 1 kHz |
| Ultrasonic Power Output | 750 W |
| Sample Throughput | 5–50 L/h |