Cell Disruptor
Filter
Showing 61–90 of 202 results
| Brand | Hanuo |
|---|---|
| Model | HN-3000 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Output Power | 3000 W |
| Operating Frequency | 20–25 kHz with Automatic Frequency Tracking |
| Sample Volume Capacity | 1000 mL |
| Temperature Control Range (Optional) | −5 °C to 100 °C |
| Programmable Storage | 20 Presets |
| Display | 4.3″ TFT Touchscreen |
| Pulse Mode Interval | 0.1–99.9 s Adjustable |
| Optional Accessories | Circulating Chiller, Magnetic Stirrer, Dual-Layer Thermostatic Reactor Vessels (50–2000 mL), Replaceable Horn Probes (Φ28 mm to Φ35 mm and Multi-Stage Extended Configurations) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-500 |
| Ultrasonic Output Power | 500 W |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | −5 to 100 °C |
| Maximum Sample Volume | 500 mL |
| Probe Material | Titanium Alloy (Grade 5) |
| Control Interface | 4.3″ TFT Touchscreen |
| Programmable Memory | 20 Presets |
| Pulse Mode Interval | 0.1–99.9 s Adjustable |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN92-II |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 650 W |
| Operating Frequency | 20–25 kHz |
| Temperature Range | −5 to 100 °C |
| Maximum Sample Volume | 650 mL |
| Number of Samples per Run | 1 |
| Probe Material | Titanium Alloy |
| Duty Cycle Adjustment | 1–99.9% |
| Automatic Frequency Tracking | Yes |
| Amplitude Stability Control | Yes |
| Integrated Temperature Monitoring & Protection | Yes |
| Brand | Hanuo |
|---|---|
| Model | HN92-IID |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 20–900 W (adjustable) |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | Ambient to 90 °C |
| Maximum Sample Volume | 1000 mL |
| Probe Diameter | Φ6 mm or Φ10 mm (included) |
| Duty Cycle | 1–99.9% |
| Sample Capacity Range | 0.2–600 mL |
| Temperature Protection Threshold | ≤90 °C |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Control System | Microprocessor-Based with Digital Interface |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN92-IIDL |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 900 W (adjustable, 20–900 W range) |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | 0–90 °C |
| Sample Volume Capacity | 0.2–600 mL |
| Probe Diameter Options | Φ6 mm or Φ10 mm |
| Integrated Overtemperature Protection | Yes (triggers at ≥90 °C) |
| Display | LCD (upgraded large-screen interface) |
| Probe Material | Medical-grade titanium alloy (Ti-6Al-4V) |
| Amplitude Stability | Auto-compensated under variable load conditions |
| Duty Cycle & Pulse Mode | Programmable on/off intervals |
| Acoustic Enclosure | Sound-dampened chamber with certified acoustic insulation (≥35 dB attenuation at 25 kHz) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN96-II |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 10–150 W |
| Operating Frequency | 20–25 kHz |
| Standard Probe | Φ6 mm |
| Sample Volume Capacity | 0.2–150 mL |
| Optional Probes | Φ2, Φ3, Φ8, Φ10 mm |
| Duty Cycle Range | 1–99.9% |
| Temperature Control Range | −5 to 100 °C |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Control System | Microprocessor-based, continuous power adjustment |
| Safety Features | Real-time temperature monitoring with thermal cutoff, automatic frequency tracking, fault diagnostics |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN96-II |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 10–150 W |
| Operating Frequency | 20–25 kHz |
| Temperature Range | Ambient to 90 °C |
| Sample Volume Capacity | 0.2–150 mL |
| Number of Samples per Run | 1 |
| Standard Probe Diameter | Φ6 mm |
| Optional Probe Diameters | Φ2, Φ3, Φ8, Φ10 mm |
| Duty Cycle | 1–99.9% |
| Integrated Temperature Monitoring & Control | Yes |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Microprocessor-Controlled Operation | Yes |
| Adjustable Amplitude with Load Compensation | Yes |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN98-I |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | Ambient to 90 °C |
| Sample Volume | (0.1–2) mL × 4 |
| Duty Cycle | 1–99.9% |
| Input Voltage | 220/110 V, 50/60 Hz |
| Cooling Interface | Yes (external chiller compatible) |
| Sample Throughput | Up to 4 tubes per cycle |
| Display | LCD |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN98-IB |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Tube | 0.2 / 0.5 / 1.5 / 2.0 mL |
| Sample Capacity | 4 or 6 tubes simultaneously |
| Duty Cycle | 1–99.9% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Display | Large LCD (touchscreen optional) |
| Cooling Interface | Optional water-circulation port for external chiller |
| Communication | RS232/RS485 optional |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN98-IB |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Tube | 0.2 / 1.5 / 2.0 mL |
| Sample Capacity | 4 or 6 tubes simultaneously |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN98-IIB |
| Instrument Type | Cup-Horn Ultrasonic Cell Disruptor |
| Ultrasonic Power | 2500 W |
| Operating Frequency | 19 kHz |
| Sample Volume per Tube | 0.1–2 mL |
| Maximum Simultaneous Samples | 8 |
| Temperature Control | Ambient (with optional external chiller interface) |
| Duty Cycle Range | 1–99.9% |
| Input Voltage | 220 V / 50 Hz (standard) |
| Compliance | CE-marked design principles |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN98-IIB |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Frequency | 20 kHz |
| Maximum Ultrasonic Power | 1200 W |
| Temperature Range | 0–99 °C |
| Sample Volume per Tube | 0.1–2 mL |
| Number of Simultaneous Samples | 4 or 6 |
| Duty Cycle | 1–99.9% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Cooling Interface | Yes (for external chiller connection) |
| Display | Large LCD |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN98-IIID |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1200 W |
| Operating Frequency Range | 19–23 kHz |
| Temperature Control Range | 0–90 °C |
| Maximum Sample Volume | 1000 mL |
| Sample Throughput | Single-sample batch processing |
| Transducer Material | Titanium alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic load-compensated adjustment |
| Display | Backlit LCD with real-time parameter monitoring |
| Data Storage | 50 programmable protocols |
| Safety Features | Overtemperature alarm, frequency tracking failure detection, acoustic enclosure with certified sound attenuation (>35 dB reduction at 1 MHz) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN98-IIIDL |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | Ambient to 90 °C |
| Sample Volume Capacity | 1000 mL |
| Sample Throughput | Single sample per cycle |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN99-IIDL |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1800 W |
| Operating Frequency | 19–23 kHz |
| Temperature Range | 0–90 °C |
| Sample Volume Capacity | 1500 mL |
| Number of Samples per Run | 1 |
| Brand | Hechuang |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HC-1500T |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–120 °C |
| Operating Frequency | 25 kHz |
| Ultrasonic Power Output | 1500 W |
| Sample Volume Capacity | 0.2–2000 mL |
| Control Interface | 7-inch capacitive touchscreen |
| Pulse Mode | Adjustable from 0.1 s to 999.9 s (on/off) |
| Amplitude Compensation | Auto-compensated |
| Transducer Material | PZT ceramic (lead zirconate titanate) |
| Probe Material | ASTM-grade TC4 titanium alloy (Ti-6Al-4V) |
| Standard Probe Diameter | 15 mm (optional: 8/10/12/20 mm) |
| Integrated Cooling Compatibility | Yes |
| Enclosure | Powder-coated steel frame with polymer housing |
| Dimensions (W×D×H) | 350 × 300 × 500 mm |
| Built-in Stainless Steel Vertical Stage | Yes |
| Brand | Hechuang |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HC-2000E |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–120 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 2000 W |
| Sample Volume Capacity | 0.2–2000 mL |
| Control Interface | 7-inch capacitive touchscreen |
| Pulse Mode Timing | 0.1 s to 999 min (on/off cycles independently configurable) |
| Probe Material | ASTM F136 TC4 titanium alloy |
| Transducer | PZT-4 piezoelectric ceramic (CV33-grade) |
| Amplitude Adjustment | 0–100% continuous |
| Real-time Display | Amplitude %, frequency (Hz), cumulative operating time, temperature (if external probe connected) |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 80 W (HPU-100) / 400 W (HPU-400A) |
| Operating Frequency | Adjustable |
| Temperature Range | 0–100 °C |
| Sample Volume | 150 µL (minimum) |
| Sample Capacity | Single sample per cycle |
| Pulse Duty Cycle | 1–99% (adjustable) |
| Timer Range | 1–99 min |
| Probe Options | 1/8″ (HPU-100), 1/2″ (HPU-400A) |
| Sample Volumes Supported | 1–100 mL (HPU-100) |
| Memory Presets | 5 user-defined protocols |
| Brand | Hielscher |
|---|---|
| Origin | Germany |
| Model | UP100H |
| Ultrasonic Power | 100 W |
| Operating Frequency | 30 kHz (auto-tuned) |
| Amplitude Control Range | 20–100% |
| Pulse Mode | 0–100% duty cycle |
| Sample Volume Capacity | 0.5–50 mL |
| Weight | 1.2 kg |
| Dimensions (L×W×H) | 180 × 130 × 50 mm |
| Power Supply | 230 V, 1 A, 50–60 Hz |
| Temperature Monitoring | Not integrated (external probe recommended for thermal-sensitive applications) |
| Brand | Hielscher |
|---|---|
| Origin | Germany |
| Model | UP200H |
| Ultrasonic Power | 200 W |
| Operating Frequency | 24 kHz (auto-tuned) |
| Amplitude Control Range | 20–100% (digital, continuous) |
| Pulse Mode | 0–100% duty cycle |
| Sample Volume Range | 0.1–1000 mL per batch |
| Flow Rate (continuous mode) | up to 2.5 L/h |
| Probe Material | Grade 5 titanium alloy (Ti-6Al-4V) |
| Dimensions (L×W×H) | 257 × 200 × 160 mm |
| Weight | 2.1 kg |
| Input Power | 230 V, 2 A, 50–60 Hz |
| Sterilization Compatibility | Autoclavable (121°C, 20 min, full probe assembly) |
| Brand | Hielscher |
|---|---|
| Origin | Germany |
| Model | UP200S |
| Ultrasonic Power | 200 W |
| Operating Frequency | 24 kHz |
| Amplitude Control Range | 20–100% |
| Pulse Mode Duty Cycle | 0–100% |
| Dimensions (L×W×H) | 290 × 210 × 100 mm |
| Weight | 2.3 kg |
| Input Voltage | 230 V, 2 A, 50–60 Hz |
| Sample Volume Capacity | 0.1–1000 mL (batch) |
| Probe Material | Grade 5 Titanium Alloy (Ti-6Al-4V) |
| Sterilization Compatibility | Autoclavable (121 °C, 20 min, 1 bar) |
| Cooling | Optional integrated coolant jacket for continuous-flow tubing |
| Brand | Hielscher |
|---|---|
| Origin | Germany |
| Model | UP400S |
| Ultrasonic Power | 400 W |
| Operating Frequency | 24 kHz |
| Amplitude Control Range | 20–100% (digitally adjustable) |
| Pulse Mode | 0–100% duty cycle |
| Sample Volume Capacity | 5–4000 mL (batch) |
| Continuous Flow Rate | Up to 50 L/h (with optional flow cell & cooling jacket) |
| Dimensions (L×W×H) | 280 × 210 × 150 mm |
| Weight | 3.2 kg |
| Input Power | 230 V, 4 A, 50–60 Hz |
| Probe Material | Grade 5 Titanium Alloy (Ti-6Al-4V) |
| Sterilization Compatibility | Autoclavable (121°C, 20 min, full probe assembly) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UP50H |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 50 W |
| Operating Frequency | 30 kHz |
| Amplitude Control Range | 20–100% |
| Pulse Mode | 0–100% duty cycle |
| Sample Volume Capacity | 0.1–500 mL |
| Dimensions (L×W×H) | 180 × 130 × 50 mm |
| Weight | 1.1 kg |
| Power Supply | 230 V, 0.63 A, 50–60 Hz |
| Probe Material | Grade 5 Titanium Alloy (Ti-6Al-4V) |
| Cooling Options | Optional jacketed flow cell or transparent acoustic enclosure |
| Brand | Hielscher |
|---|---|
| Origin | Germany |
| Model | UP50H |
| Ultrasonic Power | 50 W |
| Operating Frequency | 30 kHz (auto-tuned) |
| Amplitude Control Range | 20–100% (digital, real-time) |
| Pulse Mode | 0–100% duty cycle |
| Sample Volume Capacity | 0.1–500 mL |
| Dimensions (L×W×H) | 180 × 130 × 50 mm |
| Weight | 1.1 kg |
| Power Supply | 230 V, 0.63 A, 50–60 Hz |
| Probe Material | Grade 5 titanium alloy (Ti-6Al-4V) |
| Cooling Options | Optional recirculating chiller coupling or jacketed flow cell |
| Noise Level | <70 dB(A) at 10 cm |
| Compliance | CE, RoHS, IEC 61000-6-3/6-4 |
| Brand | HUXI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | HX-650 |
| Ultrasonic Power Range | 6.5–650 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | 0–100 °C (low-temperature circulator optional) |
| Sample Volume Capacity | 0.1–500 mL |
| Display | 7-inch full-color capacitive touchscreen |
| Pulse Mode | Ultrasonic on-time 0.1–99.9 s, off-time 0.1–99.9 s, total cycle time up to 99 h 59 min 59 s |
| Data Storage | 20 user-defined protocols |
| Probe Options | Standard Φ6 mm |
| Safety Features | Overtemperature, overload, no-load, and time-out alarms |
| Enclosure Material | Anodized aluminum + ABS injection-molded housing (main unit) |
| Dimensions (main unit) | 427 × 340 × 168 mm (D×W×H) |
| Net Weight | 11 kg |
| Soundproof Chamber Dimensions | 320 × 320 × 520 mm (L×W×H) |
| Net Weight | 13 kg |
| Power Supply | 220 V / 50 Hz or 110 V / 60 Hz (configurable) |
| Brand | HUXI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | HX-650E |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 6.5–650 W (continuously adjustable) |
| Sample Volume Capacity | 0.1–500 mL |
| Temperature Control Range | 0–100 °C (low-temperature circulator optional) |
| Display | 7-inch full-color capacitive touchscreen |
| Ultrasonic Pulse Duration | 0.1–99.9 s |
| Intermittent Interval | 0.1–99.9 s |
| Total Processing Time | 1 s–99 h 59 min 59 s |
| Data Storage | Up to 20 user-defined protocols |
| Standard Probe | Φ6 mm titanium alloy horn |
| Optional Probes | Φ2, Φ3, Φ6, Φ8, Φ10, Φ12 mm |
| Safety Features | Over-temperature, over-load, time-out, no-load, and door-interlock alarms |
| Enclosure Material | Corrosion-resistant steel + ABS injection-molded housing |
| Host Dimensions (D×W×H) | 427 × 340 × 168 mm |
| Host Weight | 11 kg |
| Soundproof Chamber Dimensions (L×W×H) | 320 × 320 × 520 mm |
| Soundproof Chamber Weight | 13 kg |
| Power Supply | 220 V / 50 Hz or 110 V / 60 Hz (configurable) |
| Brand | HUXI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JY92-IIN |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 10–650 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | 0–100 °C (low-temperature circulator optional) |
| Sample Volume Capacity | 0.1–500 mL (requires compatible titanium alloy probe selection) |
| Sample Throughput | Single-sample processing per cycle |
| Display Interface | 4.3″ capacitive TFT touchscreen (7″ optional) |
| Ultrasound Pulse Duration | 0.1–99.9 s |
| Interval Duration | 0.1–99.9 s |
| Total Process Time | Up to 99 h 59 min 59 s |
| Duty Cycle | 0.1–99.9% |
| Probe Options | Φ2, Φ3, Φ6 (standard), Φ8, Φ10, Φ12 mm titanium alloy (Grade 5, ASTM B348) |
| Overload, No-Load, and Overtemperature Protection | Yes |
| Audible Alarm System | Integrated voice alerts for operational faults, temperature excursions, and probe immersion errors |
| Data Storage | 20 user-defined protocols |
| Communication Interface | RS232 or USB (optional PC connectivity & print export) |
| Power Supply | 220 V / 110 V, 50 / 60 Hz |
| Host Dimensions (D×W×H) | 410 × 225 × 290 mm |
| Host Net Weight | 12 kg |
| Host Gross Weight | 16 kg |
| Soundproof Enclosure Gross Weight | 10 kg |
| Enclosure Dimensions (L×W×H) | 350 × 350 × 550 mm |
| Noise Reduction | >70% (A-weighted dB reduction with enclosure) |
| Brand | HUXI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | JY96-IIN |
| Ultrasonic Power Range | 1.5–150 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | 0–100 °C (low-temperature circulator optional) |
| Sample Volume Capacity | 0.1–150 mL (requires compatible probe selection) |
| Sample Throughput | Single-sample processing per cycle |
| Display | 4.3″ capacitive TFT touchscreen (7″ optional) |
| Pulse Mode | Ultrasonic on-time 0.1–99.9 s, off-time 0.1–99.9 s, total duration up to 99 h 59 min 59 s |
| Duty Cycle | 0.1–99.9% |
| Probe Options | Φ2, Φ3, Φ6 (standard), Φ8, Φ10 mm titanium alloy (Grade 5, ASTM B348) |
| Safety Features | Overload protection, no-load (dry-run) detection, real-time temperature monitoring with thermal cutoff, audible fault alerts |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY88-II |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 250 W |
| Duty Cycle | 1–99% |
| Pulse Mode | Adjustable On/Off ratio (10–90% for both ultrasonic and interval time) |
| Total Operating Time | 1–99 min |
| Standard Probe Diameter | Φ6 mm |
| Optional Probes | Φ2, Φ3, Φ2–Φ15, Φ18–Φ25 mm |
| Sample Volume Capacity | 0.2–200 mL |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Instrument Type | Ultrasonic Cell Disruptor |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | JY88-IIN |
| Ultrasonic Frequency | 20–25 kHz (auto-frequency tracking) |
| Output Power | 250 W (touch-key continuous adjustment) |
| Pulse Mode | Adjustable on-time (0.1–99.9 s) and off-time (0.1–99.9 s) |
| Total Operating Time | 1–99 min |
| Duty Cycle | 1–99% |
| Standard Probe | Φ6 mm titanium alloy horn |
| Optional Probes | Φ2, Φ3, Φ2–Φ15, Φ18–Φ25 mm |
| Sample Volume Range | 0.2–200 mL |
| Power Supply | 220/110 V AC, 50/60 Hz |