Centrifuge
Filter
Showing 781–810 of 1064 results
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Unicen 21 |
| Type | Benchtop Centrifuge |
| Max. Speed | 4200 rpm |
| Max. RCF | 2938 × g |
| Max. Capacity | 4 × 100 mL |
| Dimensions (W×D×H) | 410 × 520 × 320 mm |
| Noise Level | <60 dB(A) |
| Power Supply | 220–230 V / 50–60 Hz (CE 126), 110–120 V / 50–60 Hz (CE 127) |
| Power Consumption | 280 W |
| Safety Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Vetcen |
| Type | Benchtop Centrifuge |
| Max Speed | 11,500 rpm |
| Max RCF | 12,716 × g |
| Max Capacity | 6 × 1.5 mL + 6 × capillary tubes (1.5 × 75 mm) |
| Dimensions (W×D×H) | 270 × 400 × 270 mm |
| Noise Level | <60 dB(A) |
| Acceleration/Deceleration | 3-step programmable (Fast, Soft, Free) |
| Timer Range | 1–99 min (1 min resolution) |
| Control | Microprocessor-based with LED display (RPM/RCF/time) |
| Safety | Automatic lid lock, imbalance detection, over-speed protection, stainless steel chamber, autoclavable rotors & adapters |
| Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | Plate-Smart |
| Instrument Type | Benchtop Plate Centrifuge |
| Max Speed | 2500 rpm |
| Max RCF | 650 × g |
| Capacity | 4 × 96-well microplates, or 2 × deep-well plates, or 2 × PCR plates |
| Drive System | High-torque disc motor, direct drive |
| Control | Microprocessor-based, digital time/speed display |
| Timer Range | 1–99 min + continuous mode |
| Speed Range | 500–2500 rpm |
| Power Supply | 110–230 V, 50 Hz, 150 W |
| Max Temperature Rise | <12 °C |
| Dimensions (W×D×H) | 310 × 380 × 300 mm |
| Net Weight | 12 kg |
| Safety | Automatic rotor stop upon lid opening, mechanical safety interlock |
| Brand | RWD |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | M1324 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Cooling Function | Refrigerated |
| Configuration | Fixed-Angle Rotor |
| Target Applications | Biomolecular Separation |
| Maximum Capacity | 24 × 2 mL tubes |
| Maximum Speed | 15,800 rpm |
| Maximum RCF | 23,444 × g |
| Dimensions (W×D×H) | 285 × 262 × 286 mm |
| Brand | RWD |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Centrifuge |
| Category | High-Speed Refrigerated Centrifuge (10,000–30,000 rpm) |
| Cooling Function | Active Refrigeration |
| Rotor Configuration | Fixed-Angle Rotor |
| Target Applications | Biomolecular Separation (Nucleic Acids, Proteins) |
| Maximum Capacity | 24 × 1.5/2.0 mL Tubes |
| Maximum Speed | 15,000 rpm |
| Maximum RCF | 21,130 × g |
| Dimensions (W×H×D) | 500 × 300 × 280 mm |
| Temperature Range | −10 °C to +40 °C |
| Display | 4.3″ Capacitive Touchscreen (800 × 480 px) |
| Pre-set Programs | 12 User-Defined Protocols |
| Noise Level | <54 dB(A) |
| Weight (with rotor) | <35 kg |
| Brand | RWD |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | M1416R |
| Instrument Type | Benchtop Centrifuge |
| Function | Refrigerated Centrifuge |
| Maximum Capacity | 4 × 400 mL |
| Maximum Speed | 18,000 rpm |
| Maximum RCF | 31,152 × g |
| Dimensions (W×D×H) | 620 × 670 × 400 mm |
| Temperature Range | −10 °C to +40 °C |
| Noise Level | 56 dB(A) |
| Acceleration/Deceleration Profiles | 9 acceleration / 10 deceleration settings |
| Program Storage | Up to 100 user-defined protocols (multi-step) |
| Weight (without rotors) | 96.5 kg |
| Brand | RWD |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MX30R |
| Instrument Type | Benchtop Centrifuge |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Separation Class | Biomacromolecules |
| Maximum Capacity | 6 × 1000 mL |
| Maximum Speed | 31,000 rpm |
| Maximum RCF | 110,000 × g |
| Dimensions | 700 mm × 1048 mm × 805 mm |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | HSC-2015L |
| Instrument Type | Benchtop Centrifuge |
| Cooling Function | Refrigerated Centrifuge |
| Rotor Configuration | Horizontal (Swinging-Bucket) Rotor |
| Max. Capacity | 24 × 1.5/2.0 mL tubes, 4 × PCR 8-tube strips, 12 × 5 mL tubes |
| Max. Speed | 15,000 rpm |
| Max. RCF | 21,400 × g (at 15,000 rpm) |
| Temperature Range | –10 °C to +40 °C |
| Cooling Performance | Reaches 4 °C from ambient in <6 min |
| Acceleration Time (0→15,000 rpm) | ≤15 s (Soft Off mode), ≤45 s (Soft On mode) |
| Deceleration Time (15,000 rpm→0) | ≤15 s (Soft On mode), ≤45 s (Soft Off mode) |
| Speed Increment | 100 rpm steps (500–15,000 rpm) |
| Timer Range | 1 s – 99 min 59 s |
| Noise Level | <58 dB(A) |
| Dimensions (L×W×H) | 385 × 608 × 318 mm |
| Power Supply | 1000 W max / 500 W nominal |
| Rotor Lid | Metal, hermetically sealed |
| Chamber Finish | Corrosion-resistant electrostatically coated surface |
| Braking Mode | SOFT deceleration for sensitive sample integrity |
| Safety Features | Automatic rotor recognition (optional), lid interlock, overspeed/overtemperature/failure self-diagnosis, emergency door release under power loss |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Separation Class | Biomacromolecules |
| Maximum Capacity | 25 × 2.0 mL |
| Maximum Speed | 15,000 rpm |
| Maximum RCF | 21,400 × g |
| Dimensions (L×D×H) | 385 × 608 × 318 mm |
| Noise Level | <58 dB(A) |
| Temperature Range | –20°C to +40°C |
| Pre-cooling Time | <6 min (from ambient to +4°C) |
| Rotor Options | 0.2 mL PCR strip (4×8), 2.0 mL tubes (25×), 5.0 mL tubes (12×) |
| Safety Features | Automatic lid lock, overspeed/overtemperature/failure self-diagnosis, emergency door release, SOFT deceleration mode |
| Construction | Corrosion-resistant centrifuge chamber, hermetic rotor design, IPX4-rated motor enclosure |
| Drive System | Brushless DC motor with dual-stage vibration damping |
| Refrigeration | Imported high-efficiency compressor |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Scientz Biotechnology Co., Ltd. |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 20000 rpm |
| Max RCF | 26920 ×g |
| Max Capacity | 4 × 100 mL |
| Temperature Range | -20°C to +40°C |
| Cooling Technology | Thermal Bypass System |
| Temp. Accuracy | ±0.1°C |
| Noise Level | ≤65 dB(A) |
| Dimensions (W×D×H) | 590 × 502 × 415 mm |
| Rotor Compatibility | 12 interchangeable rotors (9 airtight fixed-angle, 3 swing-out) |
| Acceleration/Deceleration | 25–100 s (digitally adjustable) |
| Control Interface | Full-touch LCD with voice prompt |
| Rotor ID | RFID-based automatic recognition |
| Lid Actuation | Motorized lid mechanism |
| Brand | SCILOGEX |
|---|---|
| Origin | USA |
| Model | D1008 |
| Max Speed | 7000 rpm |
| RCF | 2000 × g |
| Capacity | 8 × 0.5/1.5/2.0 mL tubes or 16 × 0.2 mL PCR tubes + 2 × 0.2 mL PCR strips |
| Motor | Brushless DC motor |
| Power Input | AC 100–240 V, 50/60 Hz |
| Noise Level | ≤45 dB(A) |
| Dimensions (W×D×H) | 170 × 160 × 122 mm |
| Weight | 0.5 kg |
| Safety | Dual interlock lid system, automatic rotor stop on lid opening, IEC 61010-1 & IEC 61010-2-020 compliant |
| Included Rotors | A08-2 (8-position universal tube rotor), PCR rotor (16×0.2 mL + 2×8-strip), optional microscope slide rotor available |
| Brand | SCILOGEX |
|---|---|
| Origin | USA |
| Model | D2012 |
| Maximum RCF | 15100 ×g |
| Maximum Speed | 15000 rpm |
| Capacity | 12 × 2 mL tubes |
| Timer Range | 30 s to 99 min + HOLD mode |
| Motor | Brushless DC motor |
| Noise Level | ≤56 dB(A) |
| Dimensions (L×D×H) | 255 × 245 × 140 mm |
| Weight | 6 kg |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Safety Features | Lid interlock, overspeed protection, overtemperature detection, real-time diagnostics |
| Rotor Material | Anodized aerospace-grade aluminum alloy |
| Rotor Sterilization | Autoclavable (≥100 cycles, 121°C, 2 bar) |
| Temperature Rise at Max Speed | ≤8°C after 60 min operation |
| Origin | Italy |
|---|---|
| Type | Floor-standing Disc Stack Centrifuge |
| Model | SE03.0V |
| Max Speed | 11,000 rpm |
| Max RCF | 11,000 × g |
| Capacity | 50–1,000 L/h (batch minimum: 10 L) |
| Dimensions (W×D×H) | 670 × 455 × 880 mm |
| Power Supply | 3-phase / 380 V / 50 Hz / 1.5 kW |
| Motor Protection | IP55, Class F Insulation with Thermal Overload Protection |
| Drum Material | High-strength stainless steel (AISI 431 for spindle, precision-machined 304 stainless steel discs) |
| Casing & Frame | AISI 304 stainless steel |
| Separation Efficiency | ≤0.05% residual fat in skim milk |
| Separation Modes | Liquid–Liquid–Solid (three-phase) and Liquid–Solid (two-phase) |
| Feed/Discharge | Sanitary-grade 304 stainless steel piping with pressure gauge and micro-controlled discharge valve |
| Origin | Italy |
|---|---|
| Type | Floor-Standing Disc Stack Centrifuge |
| Model | SE03.0V |
| Max Speed | 11,000 rpm |
| Max RCF | 11,000 × g |
| Capacity | 50–1,000 L/h (batch min. 10 L) |
| Dimensions (W×D×H) | 670 × 455 × 880 mm |
| Power Supply | 3-phase / 380 V / 50 Hz / 1.5 kW |
| Motor Protection | IP55, Class F Insulation with Thermal Overload Protection |
| Drum Material | High-Strength Stainless Steel (AISI 431 for spindle, AISI 304 for housing and discs) |
| Separation Efficiency | Fat content ≤ 0.05% in skim milk |
| Separation Modes | Two-phase (liquid–solid or liquid–liquid) and three-phase (liquid–liquid–solid) |
| Compliance | Designed to meet hygienic process equipment standards for food, pharmaceutical, and biotech applications |
| Brand | Selecta |
|---|---|
| Origin | Spain |
| Equipment Type | Benchtop Centrifuge |
| Cooling Function | Refrigerated (select models) |
| Rotational Speed Range | 4,400–18,000 rpm |
| Max RCF | 28,979 × g |
| Rotor Types | Fixed-angle (including hematocrit), horizontal swing-out, and adapter-compatible configurations |
| Sample Capacity | Up to 30 × 2.0 mL, 6 × 100 mL, or 4 × 200 mL (model-dependent) |
| Application Class | Biomolecular separation (nucleic acids, proteins, organelles, viruses) |
| Compliance | Designed for GLP-compliant laboratories |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MIH(13)111-5 |
| Instrument Type | Benchtop Magnetic Separator |
| Magnetic Field Range | 0–16,000 Gauss (adjustable via DC current control) |
| Separation Gap | 5 mm |
| Feed Size Range | 0.034–1.0 mm (400–18 mesh) |
| Maximum Feed Rate | 100 kg/h (220 lb/h) |
| Batch Sample Capacity | ≥10 g |
| Rotor Speed | 0–300 rpm (DC TEFC motor, quarter-horsepower) |
| Operating Temperature | Up to 150 °C |
| Power Supply | 110–120 V or 230 V AC, 50/60 Hz, single-phase |
| Dimensions | 200 × 100 × 300 mm |
| Cabinet | Epoxy-coated orange steel enclosure |
| Feed System | Vibratory feeder with standard 62 in³ (1.0 L) hopper (optional 276 in³ / 4.5 L) |
| Compliance | Designed for ASTM D297, ISO 5725-2, and GLP-compliant mineralogical research workflows |
| Key | Brand: SETA |
|---|---|
| Origin | United Kingdom |
| Model | 90000-3 |
| Max RCF | 2214 × g |
| Max Speed | 3000 rpm |
| Temperature Range | 30–80 °C (±1 °C) |
| Timer Range | 10 s – 100 h (continuous mode available) |
| Sample Capacity | 4 positions |
| Tube Compatibility | 6" and 8" centrifuge tubes with adapters |
| Control System | Microprocessor-based, 99 programmable methods |
| Power Supply | 220/240 V, 50/60 Hz (110/120 V optional) |
| Power Consumption | 950 W |
| Dimensions (H×W×D) | 40.1 × 56.4 × 63.9 cm |
| Weight | 72.5 kg |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SH120-2 |
| Price Range | USD 1–720 |
| Centrifugation Class | Clinical Microcentrifuge |
| Max Capacity | 24 × capillary tubes (Φ1.5 mm × 75 mm) |
| Max Speed | 12,000 rpm |
| RCF | 13,500 × g |
| Power Input | 230 VA |
| Power Output | 100 W |
| Acceleration Time | <60 s |
| Deceleration Time | <120 s |
| Timer Range | 0–99 min |
| Dimensions | 280 × 310 × 265 mm (L×W×H) |
| Net Weight | 10 kg |
| Voltage/Frequency | 110 V / 60 Hz & 220 V / 60 Hz |
| Drive System | Brushless DC Motor |
| Control Interface | Intelligent Touch Panel |
| Speed Regulation | Continuous Variable (0–12,000 rpm) |
| Brand | Shanghai Anting |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5C |
| Type | Benchtop Low-Speed Refrigerated Centrifuge |
| Rotor Configuration | Swing-Bucket Horizontal Rotor |
| Max Speed | 4000 rpm |
| Max RCF | 3150 ×g |
| Capacity | 5 mL × 56 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 675 mm × 500 mm × 690 mm |
| Weight | 90 kg |
| Construction | Reinforced Engineering Plastic Housing |
| Safety | Electronic Lid Lock System |
| Cooling | Refrigerated Operation |
| Brand | Shanghai Anting |
|---|---|
| Origin | Shanghai, China |
| Model | LXJ-IIC |
| Type | Benchtop Centrifuge |
| Category | Low-Speed Refrigerated Centrifuge |
| Rotor Type | Swing-Bucket (Horizontal) |
| Max Speed | 3600 rpm |
| Max RCF | 3040 ×g |
| Max Capacity | 5 mL × 120 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 750 W |
| Dimensions (L×W×H) | 650 mm × 550 mm × 770 mm |
| Weight | 160 kg |
| Construction | Reinforced polymer housing with electronic lid lock |
| Cooling | Refrigerated operation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1-14 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed Centrifuge (10,000–30,000 rpm) |
| Function | General-Purpose Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Separation Class | Cellular & Bacterial Pelletization |
| Maximum Capacity | 24 × 2.2 mL |
| Maximum Speed | 14,800 rpm |
| Maximum RCF | 16,163 × g |
| Dimensions (H × W × D) | 176 × 226 × 212 mm |
| Power Supply | 230 V, 50/60 Hz |
| Power Consumption | 95 W |
| Minimum Speed | 200 rpm (2 × g) |
| Acceleration Time (0–14,800 rpm) | 13 s |
| Deceleration Time (14,800 rpm → 0) | 11 s |
| Noise Level (at Max Speed) | 58 dB(A) |
| Electromagnetic Compatibility | Compliant with EN 61326 |
| Safety Interlock | Motor stops and lid unlocks only when rotor is fully stationary |
| Rotor Detection | Automatic recognition of compatible fixed-angle rotors |
| Weight (without rotor) | 5.4 kg |
| Kinetic Energy | 1721 N·m |
| Brand | Sigma |
|---|---|
| Origin | Germany |
| Model | 1-14K |
| Instrument Type | Benchtop Centrifuge |
| Category | Refrigerated High-Speed Centrifuge |
| Maximum Capacity | 24 × 1.5/2.0 mL |
| Speed Range | 200–15,000 rpm |
| Increment | 100 rpm |
| Maximum RCF | 16,602 × g |
| RCF Increment | 10 × g |
| Temperature Range | −10 °C to +40 °C |
| Temperature Increment | 1 °C |
| Time Setting | 10 s – 99 min 59 s (1 s increment) |
| Dimensions (H×D×W) | 236 × 515 × 273 mm |
| Net Weight (without rotor) | 19 kg |
| Noise Level | <60 dB(A) |
| Cooling System | Gas Ventilation-Based Thermal Management |
| Rotor Compatibility | Fixed-angle polypropylene & aluminum rotors (e.g., 12× and 24× microtube configurations), capillary rotors, PCR strip adapters |
| Brand | Sigma |
|---|---|
| Origin | Germany |
| Model | 3K-15 |
| Instrument Type | Benchtop Centrifuge |
| Function | Refrigerated Centrifuge |
| Maximum Speed | 15,300 rpm |
| Maximum RCF | 21,460 × g |
| Maximum Capacity | 4 × 200 mL |
| Temperature Range | –10 °C to +40 °C (operational), with pre-cooling capability at standstill |
| Drive System | Brushless Frequency-Controlled Motor |
| Refrigerant | R134a (CFC-free) |
| Acceleration/Deceleration Profiles | 20 programmable curves |
| Memory Programs | 10 user-defined protocols |
| Safety Compliance | IEC 61010-1, ISO 9001 certified |
| Dimensions (H×W×D) | 375 × 410 × 675 mm |
| Net Weight | 64 kg |
| Power Supply | 220 V, 50/60 Hz |
| Noise Level | ≤66 dB(A) (with rotor 12154 at 14,500 rpm) |
| Rotor Recognition | Magnetic auto-detection system |
| Control Interface | Digital microprocessor with LCD display for speed, RCF, time, temperature, and rotor ID |
| Brand | Sigma |
|---|---|
| Origin | Germany |
| Model | Sigma 3K-15 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 100–15,300 rpm |
| Max RCF | 23,031 × g |
| Max Capacity | 4 × 200 mL |
| Temperature Range | −20 °C to +40 °C |
| Dimensions (W×D×H) | 375 × 410 × 675 mm |
| Net Weight (without rotor) | 64 kg |
| Noise Level | <63 dB(A) |
| Acceleration Time | 20 s |
| Minimum Deceleration Time | 28 s |
| Motor | Brushless Frequency-Controlled Drive |
| Power Supply | 230 V, 50/60 Hz |
| Centrifugation Power | 460 W |
| Cooling Power | 550 W |
| Refrigerant | R134a (CFC-free) |
| Safety Compliance | IEC 61010-1, ISO 9001 certified |
| Brand | Sigma |
|---|---|
| Origin | Germany |
| Model | Sigma1-14 |
| Maximum Capacity | 24 × 2.2 mL |
| Maximum Speed | 14,800 rpm |
| Dimensions (H×W×D) | 176 × 226 × 212 mm |
| Power Consumption | 95 W |
| Noise Level | < 60 dBA |
| Acceleration/Deceleration Profiles | 2 programmable curves |
| Time Control | 0–99 min 59 s / Continuous / Short-spin mode |
| RCF Range | 2 × g to 16,163 × g |
| Motor Type | Brushless DC |
| EMC Compliance | EN 55011 Class B |
| Interference Immunity | EN 61326 |
| Weight (without rotor) | 5.4 kg |
| Max Kinetic Energy | 1721 N·m |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WX |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Model | Legend Micro 17 / Legend Micro 17R / Legend Micro 21 / Legend Micro 21R |
| Max RCF | 17,000 × g / 21,000 × g |
| Max Speed | 13,300 rpm / 14,800 rpm |
| Capacity | 24 × 1.5 mL / 2.0 mL tubes |
| Drive System | Brushless frequency-sensing direct-drive motor |
| Temperature Range (Refrigerated models) | –9 °C to 40 °C |
| Noise Level | ≤56 dB(A) |
| Acceleration/Deceleration Time | 11–13 s |
| Safety Features | Automatic rotor recognition, lid interlock, imbalance detection, self-diagnostic system, electronic circuit protection |
| Compliance | IEC 61010-1, EN 61326-1 (EMC), FDA 21 CFR Part 11-ready software architecture |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model Numbers | 50135643, 50135648 |
| Instrument Type | Floor-Model Ultracentrifuge |
| Speed Range | Up to 150,000 rpm (Model-Dependent) |
| Maximum RCF | 1,048,000 × g |
| K-Factor Range | As low as 14–35 (Rotor-Dependent) |
| Noise Level | <45 dBA |
| Footprint | 0.53 m² (5.7 ft²) |
| Rotor Compatibility | Fixed-angle, swinging-bucket, vertical rotors |
| Tube Capacity | 0.2–30 mL |
| Sample Types | Viruses (HIV, SRSV, rotavirus), organelles (ribosomes, mitochondria, microsomes), lipoproteins, nanoparticles, nucleic acids |
| Drive System | Brushless DC motor with imbalance detection and auto-shutdown |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Model | Sovall X4R Pro-MD |
| Configuration | Floor-standing or benchtop, refrigerated |
| Maximum RCF (fixed-angle) | >25,000 × g |
| Maximum RCF (swing-bucket) | >7,000 × g |
| Capacity | 1.6 L (4 × 400 mL) or 4 L (4 × 1000 mL) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TD5A |
| Price | USD 850 (FOB) |
| Type | Low-Speed Centrifuge (Max. 5500 rpm) |
| Target Separation Class | Biological Macromolecules |
| Max. Capacity | 4 × 250 mL |
| Max. Speed | 5500 rpm |
| Dimensions | 600 × 540 × 360 mm |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 500 W |
| Net Weight | 35 kg |
| Control System | Microprocessor-based AC Brushless Frequency-Controlled Motor Drive |
| Acceleration/Deceleration Profiles | 10 selectable ramp rates |
| Stored Programs | 20 user-defined protocols |
| Display | TFT true-color touchscreen (simultaneous setpoint & real-time parameter display) |
| Rotor Recognition | On-screen rotor image identification |
| Safety Features | Electro-mechanical door interlock, automatic imbalance detection, self-balancing suspension system, stainless steel centrifuge chamber, full-steel structural frame |