Centrifuge
Filter
Showing 841–870 of 1064 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | MR23i |
| Maximum RCF | 36,668 × g |
| Maximum Speed | 23,000 rpm |
| Temperature Range | −8 °C to +40 °C (1 °C increments) |
| RCF Range | 20–36,668 × g |
| Speed Range | 500–23,000 rpm |
| Acceleration/Deceleration Profiles | 10 each |
| Timer | 1 s–99 min 59 s + continuous |
| HRF (Centrifugation Integral) | 100–281 × 10¹² |
| Capacity | 4 × 200 mL (swing), 6 × microplates, 60 × 1.5/2 mL (fixed-angle), 192 × 0.4 mL (rotor-specific) |
| Safety Certifications | CAMR-compliant sealed rotors |
| Drive System | Brushless motor with AUTO-LOCK quick-change rotor interface (≤5 s) |
| Control Interface | VIDEOset™ graphical touchscreen panel (20-bit display, 4-language support: English, Spanish, French, German) |
| Data Management | 32 user-programmable protocols with password protection |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Multifuge X1 |
| Max Capacity | 6 × 400 mL |
| Max Speed | 15,200 rpm |
| Max RCF | 25,830 × g (with fixed-angle rotor) |
| Temperature Range | –10 °C to +40 °C |
| Dimensions (W × D × H closed) | 44 cm × 60.5 cm × 36 cm |
| Weight | 57.5 kg (base configuration) / 91.5 kg (fully equipped) |
| Compliance | IEC 61010-1, IEC 61010-2-020, EN 292, EN 61326, EN 55011 Class B |
| Certifications | UL, CSA, CE, IVD |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Sorvall Legend Mach 1.6/R |
| Maximum Speed | 15,000 rpm |
| Maximum RCF | 24,652 × g |
| Capacity | 4 × 400 mL (horizontal rotor) or 6 × 94 mL (Highconic fixed-angle rotor) |
| Temperature Range (Refrigerated Model) | −9 °C to +40 °C |
| Drive System | Brushless DC Motor |
| Control Interface | EASYset keypad or QUIKset dial |
| Acceleration/Deceleration Programs | 9/9 (EASYset) or Soft Brake (QUIKset) |
| Dimensions (H×W×D) | 365 × 686 × 665 mm |
| Weight | 118 kg |
| Safety Certification | IEC 61010-1/-2-20, cCSA, CE |
| Compliance | CAMR-certified biosafety enclosure |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Benchtop Refrigerated Centrifuge |
| Model No. | 75002440 |
| Max Speed | 13,300 rpm |
| Max RCF | 17,000 × g |
| Dimensions (W×D×H) | 225 × 243 × 352 mm |
| Temperature Range | -9 °C to 40 °C |
| Standard Rotor | 24-position fixed-angle rotor for 1.5/2.0 mL tubes |
| Rotor Compatibility | Dual-row 18×2×0.5/1.5 mL, 36×0.5 mL, PCR strip rotor, hematocrit capillary rotor |
| Safety Certification | IEC 61010-1, ISO 13485 compliant |
| Software Compliance | Audit trail-capable operation log (GLP/GMP-ready) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Legend T Plus / Legend RT Plus |
| Maximum RCF | 24,400 × g |
| Max Speed (Fixed-Angle Rotor) | 15,000 rpm |
| Max Capacity (Horizontal Rotor) | 4 × 750 mL |
| Temperature Range (RT Plus only) | –9 °C to 40 °C |
| Power Supply | 120 V / 230 V (50/60 Hz) |
| Motor Type | Brushless DC |
| Safety Features | SMARTspin imbalance detection, auto rotor recognition, touch-activated lid lock |
| Control System | Digital microprocessor with self-diagnostics |
| Timer Range | 1 min – 99 h + hold |
| Acceleration/Deceleration Rates | 9 each |
| Pre-cool Function | Yes |
| Programmable Protocols | 4 user-defined + pre-cool |
| Dimensions (H×W×D) | 362 × 551 × 666 mm (T Plus), 362 × 733 × 666 mm (RT Plus) |
| Weight | 89 kg (T Plus), 131 kg (RT Plus) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Sorvall Stratos |
| Maximum Speed | 23,300 rpm |
| Maximum RCF | 50,377 × g (200–230 V models) |
| Temperature Range | −9 °C to +40 °C |
| Capacity | 4 × 180 mL (horizontal rotor) or 24 × 1.5/2.0 mL (fixed-angle rotor) |
| Drive System | Brushless Spindle Motor |
| Acceleration/Deceleration Steps | 9 each |
| Programmable Methods | 9 user methods + 1 pre-cool program |
| Noise Level | <60 dB(A) at maximum speed |
| Dimensions (H×W×D) | 395 × 640 × 595 mm |
| Weight (without rotors) | 134 kg |
| Power Consumption | 1400 W (refrigeration system: 900 W) |
| Safety | Dual interlocked door, automatic rotor recognition, real-time imbalance detection |
| Control System | EASYcontrol™ II microprocessor-based interface |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Centrifuge Automation Module |
| Quotation | Upon Request |
| Centrifuge Model | Hettich Rotanta 46 RSC |
| Throughput | Up to 400 tubes/hour |
| Rotor Capacity | 4 × 24 tubes per run |
| Compatible Tube Dimensions | 13 × 75 mm and 13 × 100 mm |
| Power Supply | 100–240 V ±10%, 50–60 Hz ±5% |
| Operating Ambient Temperature | 15–32 °C |
| Relative Humidity | 40–80 % RH (non-condensing) |
| Acoustic Noise Level | <65 dB(A) (Rotanta), <70 dB(A) (system) |
| Power Consumption | 300 W (standby/control), 2000 W (centrifuge at 230–240 V) |
| Pneumatic Supply | 5 bar, 5 µm filtration, oil-free lubrication |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model No. | 75006590 |
| Instrument Type | Floor-standing Centrifuge |
| Speed Class | Ultrahigh-speed Centrifuge (>30,000 rpm) |
| Cooling Function | Refrigerated Centrifuge |
| Configuration | Fixed-angle Rotor System |
| Maximum Capacity | 6 L |
| Maximum RCF | 100,605 × g |
| Rotor Interface | Auto-ID Enabled |
| Display | Centri-Touch High-Visibility Touchscreen |
| Connectivity | Centri-Vue Mobile App (Local & Networked Control) |
| Compliance | GLP/GMP-Ready Data Management, FDA 21 CFR Part 11 Compatible Audit Trail Support |
| Safety | Integrated HEPA Filtration Option, Non-bolted Door Mechanism, Automatic Lid Locking |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Sorvall LYNX |
| Instrument Type | Floor-standing centrifuge |
| Speed Range | 10,000–29,000 rpm |
| Max RCF | 100,650 × g |
| Max Capacity | 6 × 1000 mL |
| Dimensions (H×D×W) | 930 × 805 × 700 mm |
| Weight | 293 kg |
| Temperature Range | –20 to +40 °C |
| Vacuum System | Intelligent vacuum system with optional HEPA filtration |
| Drive | High-torque brushless motor |
| Rotor Locking | Auto-Lock® |
| Rotor Recognition | Auto-ID® |
| Rotor Material | Fiberlite® carbon fiber |
| Biosafety | ClickSeal® biocontainment lid |
| Acceleration/Deceleration | 9 acceleration / 10 deceleration profiles |
| Run Time | Up to 99 h continuous |
| Pre-cooling | Yes |
| ACE Integrator | Yes |
| Compliance Features | User log, role-based access control, audit trail, automatic door opening, rotor cover handle, integrated training videos, multilingual UI |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | MTX 150 |
| Max. Capacity | 6 × 30 mL |
| Max. Speed | 150,000 rpm |
| Dimensions (H×W×D, lid closed) | 40 cm × 59 cm × 58 cm |
| Noise Level | <45 dBA |
| Max. RCF | 1,048,000 × g |
| Acceleration Time to 150,000 rpm (with S150-AT rotor) | ≤80 s |
| Power Supply | Standard laboratory AC outlet (100–240 V, 50/60 Hz) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ST 8 |
| Maximum RCF | 24,328 × g |
| Max Speed | 16,000 rpm |
| Min Speed | 300 rpm |
| Capacity (Horizontal) | 4 × 145 mL |
| Capacity (Fixed-Angle) | 6 × 50 mL |
| Rotor Locking | Auto-Lock® |
| Biosafety Lid | ClickSeal® Certified |
| Control System | Microprocessor-Driven Direct-Drive Induction Motor |
| Acceleration/Deceleration Profiles | 2 (Standard & Soft) |
| Timer Range | 0–9 h 59 min + Continuous |
| Noise Level | <58 dBA (TX-150), <61 dBA (MicroClick 24) |
| Power Consumption | 310 W |
| Dimensions (H×W×D) | 67 cm (lid open) / 31 cm (lid closed) × 37 cm × 48 cm |
| Weight | 35 kg |
| Program Storage | 4 User-Named Protocols with Password Protection |
| Compliance | IEC 61010-1, ISO 13485 (for in vitro diagnostic use), EN 61326-1 (EMC) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ST16R / ST40R |
| Max Rotor Capacity | 4×750 mL (ST40R, BIOLiner rotor) |
| Max Speed | 15,200 rpm (micro-angle rotors) |
| Max RCF | 25,830 ×g |
| Temperature Range | –10°C to +40°C |
| Acceleration/Deceleration Steps | 9/10 |
| Timer Range | 9 hr 59 min + continuous |
| Noise Level | <61 dBA (ST16R), <61 dBA (ST40R) |
| Refrigeration | CFC-free compressor-based system |
| Motor | Brushless DC induction motor |
| Control System | Microprocessor-driven SMARTSpin® with 6 programmable quick-start protocols |
| Safety Certifications | IEC 61010-1, ISO 13485 compliant design, ClickSeal® biosafety-certified lid locking |
| Rotor Locking | Auto-Lock® III mechanical self-aligning rotor engagement |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Benchtop Ultracentrifuge |
| Speed Range | Up to 80,000 rpm |
| Max RCF | 546,883 × g (with T-890 rotor) |
| Max Capacity | 6 × 250 mL |
| Temperature Control | Refrigerated (0–40 °C) |
| Cooling System | Solid-state thermoelectric (CFC/HCFC/HFC-free) |
| Dimensions (H×W×D) | 88 × 79 × 69 cm |
| Net Weight | 390 kg |
| Noise Level | ≤51 dBA (1 m front, operational) |
| Power Supply | 208–240 V, 50/60 Hz, 16–20 A |
| Program Storage | 1,000 user-defined protocols with stepwise centrifugation |
| Compliance | CE, cCSAus |
| Rotor Type | Fixed-angle (standard configuration) |
| Application Class | Biomolecular separation (e.g., nucleic acids, viruses, subcellular organelles) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | WX100 |
| Max. Capacity | 6 × 250 mL |
| Max. Speed | 100,000 rpm |
| Dimensions (H × W × D) | 1000 mm × 790 mm × 690 mm |
| Weight | 400 kg |
| RCFmax | 802,000 × g |
| Temperature Range | 0–40 °C |
| Temp. Control Accuracy | ±0.5 °C |
| Vacuum Level | 0.13 Pa |
| Drive System | Vacuum-coupled, imbalance-tolerant motor |
| Acceleration/Deceleration | 10/11 steps |
| Speed Setting Range | 1,000–100,000 rpm (100 rpm increments) |
| Speed Accuracy | ±10 rpm |
| Cooling System | Solid-state thermoelectric (CFC-free) |
| Vacuum System | Oil-rotary pump with dehydrator + oil diffusion pump |
| Noise Level | 53 dBA (1 m front) |
| Power Supply | 208–240 V, 50/60 Hz, single-phase, 16–20 A |
| Certifications | CE, cCSAus |
| Control Interface | Microprocessor-based, 20 programmable methods, step-wise centrifugation, RCF auto-conversion, ω²t integrator, real-time runtime control, user access levels, automatic rotor lifetime tracking |
| Heat Dissipation | <1 kW/h |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | Sorvall™ Legend™ Micro 21R |
| Centrifuge Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 14,800 rpm |
| Max RCF | 21,100 × g |
| Max Capacity | 24 × 1.5/2.0 mL tubes |
| Cooling Time | ≤9 min (from 22°C to 4°C) |
| Acceleration to Max RCF | ≤12 s |
| Dimensions (W × D × H) | 33.0 × 29.5 × 44.5 cm |
| Rotor Options | 7 interchangeable microcentrifuge rotors |
| Compliance | EU Directive 98/79/EC (IVDD), IEC 61010-1, IEC 61010-2-020 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Sorvall™ ST 8 Benchtop Centrifuge |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | ST16 High-Speed Benchtop Centrifuge |
| Maximum Speed | 15,200 rpm |
| Maximum RCF | 25,830 × g |
| Maximum Capacity | 4 × 400 mL |
| Control System | Microprocessor-based with backlit large LCD display and LED status indicators |
| Time Range | 0–9 h 59 min (with short-spin and continuous modes) |
| Acceleration/Deceleration Profiles | 9 acceleration / 10 deceleration settings |
| Power Supply | 230 V, 50/60 Hz |
| Dimensions (W × D × H) | 580 × 630 × 370 mm |
| Weight | 72 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Fresco 17 / Fresco 21 |
| Maximum RCF | 17,000 × g / 21,000 × g |
| Acceleration/Deceleration Time | 12 s / 12 s |
| Certified Biosafety | CAMR-validated ClickSeal™ rotors |
| Compliance | IEC 61010-1, IEC 61010-2-020, IEC 61326, cCSAus (120 V models) |
| Rotor Compatibility | 24 × 1.5–2.0 mL (ClickSeal™), 18 × (2.0 + 0.5 mL dual-row), 36 × 0.5 mL, 48 × 0.2 mL PCR tubes, hematocrit capillaries |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Pico 17 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | General-Purpose Centrifuge |
| Typical Configuration | Fixed-Angle Rotor Centrifuge |
| Separation Class | Biomacromolecules |
| Maximum Capacity | 24 × 2 mL |
| Maximum Speed | 13,300 rpm |
| Maximum RCF | 17,000 × g |
| Dimensions (H × W × D) | 22.5 × 24.3 × 35.2 cm |
| Noise Level | 56 dB(A) |
| Operating Temperature | Ambient |
| Certifications | CSA, CE, IVD Directive 98/79/EC, IEC 61010-1, IEC 61010-2-020 |
| Rotor Included | 24-position fixed-angle rotor with ClickSeal biocontainment lid |
| Warranty | 2 years |
| Timer Range | 1–99 min (1-min increments), HOLD mode |
| Net Weight | 10.5 kg |
| Electrical Requirements | 230 V, 50/60 Hz |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Heraeus Pico 17/21 / Fresco 17/21 |
| Centrifuge Type | Benchtop Microcentrifuge |
| Max Speed | 30,000 rpm |
| Max RCF | 21,000 × g |
| Max Capacity | 24 × 2 mL |
| Acceleration/Deceleration Time | 12 s / 12 s |
| Dimensions (W×D×H) | 310 × 436 × 568 mm |
| Rotor Compatibility | Fixed-angle rotors for 0.2–2.0 mL tubes, including PCR strips, hematocrit capillaries, and filter-based spin columns |
| Safety Certification | CAMR-validated ClickSeal™ biocontainment rotors |
| Cooling Type | Refrigerated (Fresco) and Ventilated (Pico) variants |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific Laboratory Products |
| Price Range | USD 35,000 – 42,000 (FOB) |
| Centrifugation Class | Biomacromolecules |
| Maximum Capacity | Not specified |
| Maximum Speed | Not specified |
| Dimensions | Not specified |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | MicroCL 17 & 21 |
| Max RCF | 17,000 × g (MicroCL 17) / 21,100 × g (MicroCL 21) |
| Max RPM | 13,300 (MicroCL 17) / 14,800 (MicroCL 21) |
| Timer Range | 1–99 min |
| Temperature Range | Ambient only (MicroCL 17/21) |
| Noise Level | <55 dBA (MicroCL 17/21), <56 dBA (MicroCL 21) |
| Dimensions (H×D×W) | 225 × 243 × 352 mm (non-refrigerated), 330 × 295 × 445 mm (refrigerated) |
| Net Weight | 11 kg (non-refrigerated), 28 kg (refrigerated) |
| Certified | CAMR-validated ClickSeal™ biocontainment rotor |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Model | MSC-Advantage |
| Certification | EN 12469:2000, IEC 61010-1:2001, EN 61010-1:2001, NF S 09-500 Rev. 3.2006, DIN EN 61326-1:2004-05 |
| Filter Efficiency | ≥99.999% @ 0.3 µm (HEPA H14 per EN 1822) |
| Airflow Control | Dual independent fan system with real-time active compensation |
| Work Area Construction | Monolithic U-shaped stainless steel chamber with fully sealed side walls |
| Performance Indicator | Real-time Performance Factor (PF) display on control panel |
| Noise Level | <55 dB(A) (MSC-Advantage 1.2) / <57 dB(A) (MSC-Advantage 1.8) |
| Illumination | >1200 lx |
| Power Consumption | 0.4 kW (1.2 m) / 0.8 kW (1.8 m) |
| Compliance | YY 0569–2005, Low Voltage Directive 73/23/EEC, EMC Directive 89/336/EEC |
| External Dimensions (W×H×D, with stand) | 1300×2200×795 mm (1.2 m) / 1900×2200×795 mm (1.8 m) |
| Front Window Opening Height | 535 mm |
| Net Weight | 240 kg / 340 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Benchtop Centrifuge |
| Model | Multifuge X1/X1R Pro |
| Speed Range | 200–15,200 rpm |
| Max RCF | 25,830 × g |
| Max Capacity | 4 × 400 mL (TX-400 rotor) |
| Dimensions | 36.2 × 56.6 × 66 cm (W × D × H) |
| Rotor Options | 17 interchangeable rotors including Microliter 30 × 2 and TX-400 |
| Compliance | CE, IEC 61010-1, ISO 13485 (for in vitro diagnostic use where applicable), CAMR-certified ClickSeal™ biocontainment system |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Benchtop Centrifuge |
| Model | Multifuge X4 / X4R Pro |
| Sample Capacity | 196 × 5/7 mL blood collection tubes, 148 × 9/10 mL blood collection tubes, 96 × 15 mL conical tubes, 40 × 50 mL conical tubes, 6 × microplates, or 4 × 1000 mL bio-bottles (with TX-1000 rotor) |
| Max RCF | 25,830 × g (fixed-angle, with 30 × 2 mL rotor) |
| Max Speed | 15,200 rpm (fixed-angle) |
| Dimensions | 690 mm × 566 mm × 362 mm |
| Temperature Control | Dual-sensor system monitoring both chamber air and sample temperature |
| Rotor System | Auto-Lock™ III quick-release, ClickSeal™ biosafety lid, Fiberlite™ carbon-fiber rotors |
| Energy Efficiency | Up to 40% reduction vs. standard protocols |
| Compliance | CAMR™ certified (Porton Down, UK), designed for GLP/GMP environments with audit-ready operation logs |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | Multifuge X4 F/X4R F Pro |
| Instrument Type | Floor-standing Centrifuge |
| Speed Range | Up to 5,200 rpm (with Microliter 30 × 2 rotor) |
| Max RCF | 25,830 × g (with Microliter 30 × 2 rotor) |
| Max Capacity | 4 × 1000 mL (with TX-1000 rotor) |
| Dimensions | 83.5 × 56.6 × 69 cm |
| Compliance | CAMR-certified ClickSeal™ biocontainment system |
| Key Features | Auto-Lock™ III rotor auto-engagement, SMARTSpin™ intelligent rotor management, Fibelite™ carbon-fiber rotors, electric lid latch, touchscreen HMI with usage tracking and rotor lifecycle monitoring |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Model Number | 75009022 |
| Capacity | 4 L (with TX-1000 swing-bucket rotor) |
| Temperature Range | -9 °C to 40 °C |
| Max RCF | 4,900 × g |
| Max Speed | 5,200 rpm |
| Compliance | Designed for cGMP, ISO 13485, and cleanroom environments (Class A/B/C/D) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | Multifuge X4R Pro |
| Max Rotor Capacity | 4 × 1000 mL |
| Max Speed | 15,200 rpm (25,830 × g) |
| Biocontainment | ClickSeal™ Sealed Rotor Lid |
| Rotor Locking | Auto-Lock™ Quick-Release System |
| Rotor Material | Fiberlite™ Carbon Fiber |
| Compatible Rotors | Up to 18 types including H-Flex™ and F10-6×100 mL LEX |
| Compliance | CAMR™ Certified (Porton Down, UK) |
| Software | ACE Pre-cooling, Pulse Mode, Step Programming |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Model | Pico & Fresco Microcentrifuge Series (Pico 17 / Pico 21 / Fresco 17 / Fresco 21) |
| Max RCF | 17,000 × g or 21,000 × g |
| Noise Level | <56 dBA (ventilated) / <50 dBA (refrigerated) |
| Motor | Brushless DC |
| Safety Certification | CAMR-validated ClickSeal® biocontainment |
| Rotor Materials | PPSU rotor lids, stainless steel rotors |
| Compliance | ISO 13485 design principles, GLP-compatible operation log |
| Dimensions (W×D×H) | 22.5 × 32.5 × 23.5 cm |
| Weight | ~12 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Model | Sorvall BIOS 16 |
| Instrument Type | Benchtop Centrifuge |
| Function | General-purpose Bioprocessing Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Separation Class | Biomacromolecules |
| Maximum Capacity | 8 × 2000 mL |
| Maximum Speed | 5,400 rpm |
| Maximum RCF | 8,500 × g |
| Dimensions (H×W×D) | 101.5 × 81.6 × 90.0 cm |
| Weight | 465 kg |
| Temperature Range | –20 °C to +40 °C (1 °C increments) |
| Power Supply | 220–240 V, 50/60 Hz, single-phase |
| Certifications | UL, CE, FDA-compliant |
| Software Compatibility | Centri-Log Plus (21 CFR Part 11 compliant) |
| Warranty | 2 years full system, 5 years on drive and refrigeration systems |