| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | TD5A-WS |
| Max Speed | 5000 rpm |
| Max RCF | 4390 × g |
| Timer Range | 0–99 min |
| Power Supply | AC 220 V, 50 Hz, 10 A |
| Dimensions (L×W×H) | 460 × 550 × 340 mm |
| Weight | 50 kg |
| Rotor Configurations | No.1 Swing Rotor (7 mL × 72, 4000 rpm, 3000 × g) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TD5GL |
| Pricing | Available Upon Request |
| Max Speed | 5000 rpm |
| Max RCF | 4100 × g |
| Capacity | 1000 mL / 2000 mL / 3000 mL (rotor-dependent) |
| Timer Range | 0–99 min |
| Power Supply | AC 220 V, 50 Hz, 5 A |
| Dimensions (L×W×H) | 460 × 550 × 370 mm |
| Weight | 40 kg |
| Regulatory Certifications | ISO 9001:2000 (Cert. No. EWC61104Q) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | TD5T |
| Price | ¥24,800 |
| Centrifugation Class | General-purpose petroleum analysis |
| Max Capacity | 4 × 250 mL |
| Max Speed | 5000 rpm |
| Dimensions | 600 × 540 × 360 mm |
| Max RCF | 4200 × g |
| Speed Accuracy | ±50 rpm |
| Temperature Range | Ambient +10 °C to 70 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 h 59 min |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Weight | 50 kg |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | TDL-4 |
| Price Range | USD 15–750 (FOB) |
| Centrifugation Class | General-Purpose Laboratory Centrifuge |
| Max Capacity | 6 × 20 mL (or 6 × 15 mL) |
| Max Speed | 0–4000 rpm |
| Relative Centrifugal Force (RCF) | 2325 × g |
| Timer Range | 0–60 min |
| Power | 85 W |
| Noise Level | ≤60 dB(A) |
| Supply | AC 220 V, 50 Hz, 2 A |
| Rotor Material | Anodized Aluminum Alloy |
| Drive System | Brushless DC Motor |
| Safety Features | Mechanical Lid Interlock, Dual-Fuse Protection, Imbalance Detection & Auto-Shutdown |
| Display | Analog Speed Indicator + Mechanical Timer Dial |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Centrifuge Class | Low-Speed |
| Max Speed | 0–4000 rpm |
| Max RCF | 2770 × g |
| Capacity | 100 mL × 4 / 50 mL × 8 / 15 mL × 16 |
| Timer Range | 0–30 min |
| Power | 250 W |
| Noise Level | ≤60 dB(A) |
| Input | AC 220 V, 50 Hz, 3 A |
| Rotor Material | Stainless Steel |
| Control Interface | Touch Panel with Digital Display (RPM, Time, RCF) |
| Safety Features | Electronic Lid Lock, Dual Thermal Fuses, Imbalance Detection & Auto Shutdown |
| Rotor Type | Horizontal Swing-Out |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | TDL-50 |
| Price Range | USD 1–699 |
| Centrifugation Class | General-Purpose Laboratory Centrifuge |
| Max Capacity | 6 × 50 mL |
| Max Speed | 4000 rpm (infinitely variable) |
| RCF | 2325 × g |
| Timer Range | 0–60 min |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz, 2 A |
| Rotor Material | Anodized Aluminum Alloy |
| Rotor Type | Fixed-angle, stainless steel protective sleeves included |
| Compliance | CE-marked per IEC 61010-1, EN 61326-1 |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | TDL-50A |
| Price Range | USD 1–699 |
| Centrifugation Class | General-Purpose Benchtop Centrifuge |
| Maximum Speed | 4000 rpm (stepless variable speed, digital speed display) |
| RCF | 2325 × g |
| Capacity | 6 × 50 mL (stainless steel rotor sleeves) |
| Timer Range | 0–60 min |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz, 2 A |
| Dimensions | Not specified |
| Weight | Not specified |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TDL-5A |
| Maximum Speed | 0–5000 rpm |
| Relative Centrifugal Force (RCF) | 2770 × g |
| Maximum Capacity | 250 mL × 4 / 50 mL × 8 / 10 mL × 28 |
| Timer Range | 0–30 min |
| Power Consumption | 320 W |
| Noise Level | ≤60 dB(A) |
| Supply Voltage | AC 220 V, 50 Hz, 5 A |
| Rotor Material | Stainless Steel |
| Control Interface | Touchscreen with Digital Display (RPM, Time, RCF) |
| Safety Features | Electronic Door Lock, Dual Thermal Fuses, Automatic Rotor Imbalance Detection |
| Key | Origin: Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Max Speed | 5000 rpm |
| Max RCF | 4390 × g |
| Temperature Range | −20 °C to +40 °C |
| Timer | 0–99 min |
| Dimensions (L×W×H) | 460 × 550 × 400 mm |
| Weight | 75 kg |
| Power Supply | AC 220 V, 50 Hz, 15 A |
| Certifications | ISO 9001:2000, Hunan Medical Device Production Filing No. 20030027, Registration Nos. Xiang Chang Yao Guan Xie (Zhun) Zi 2003 No. 1410036–1410039 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Models | TDZ5-WS, TD5M-WS |
| Max Speed | 5000 rpm |
| Max RCF | 4390 × g (TDZ5-WS), 5030 × g (TD5M-WS) |
| Timer Range | 0–99 min (TDZ5-WS), 0–99 h 59 min (TD5M-WS) |
| Power Supply | AC 220 V, 50 Hz, 10 A |
| Dimensions (L×W×H) | 440×550×340 mm (TDZ5-WS), 460×550×340 mm (TD5M-WS) |
| Weight | 45 kg (TDZ5-WS), 50 kg (TD5M-WS) |
| Rotor Compatibility | Swing rotors for 7–250 mL tubes, 96-well microplate carriers, and optional conical cup adapters |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Models | TDZ4-WS, TDZ4A-WS |
| Pricing | Upon Request |
| Max Speed | 5000 rpm |
| Max RCF (TDZ4-WS) | 3470 ×g |
| Max RCF (TDZ4A-WS) | 2515 ×g |
| Angle Rotors | TDZ4-WS — 10 mL × 18, 10 mL × 24, 20 mL × 12 |
| Timer Range | 0–99 min |
| Power Supply | AC 220 V, 50 Hz, 5 A |
| Dimensions (TDZ4-WS) | 330 × 420 × 275 mm (L×W×H) |
| Dimensions (TDZ4A-WS) | 230 × 310 × 240 mm (L×W×H) |
| Weight (TDZ4-WS) | 15 kg |
| Weight (TDZ4A-WS) | 10 kg |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TDZ4-WS |
| Price | USD 470 (FOB) |
| Type | Low-Speed Centrifuge |
| Max. Speed | 4000 rpm |
| Max. RCF | 2600 × g |
| Max. Capacity | 4 × 100 mL |
| Dimensions (L×W×H) | 500 × 450 × 280 mm |
| Weight (with rotor) | 20 kg |
| Speed Accuracy | ±30 rpm |
| Timer Range | 0–99 h 59 min / Continuous / Short-Pulse Mode |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Drive System | Brushless Frequency-Controlled Motor |
| Rotor Compatibility | Interchangeable fixed-angle and swing-out rotors (e.g., 4×100 mL, 12×20 mL, 18×10 mL, 24×10 mL, 8×20 mL, 12×15 mL, 4×50 mL) |
| Chamber Material | Stainless Steel (AISI 304) |
| Control Interface | TFT True-Color Touchscreen Display |
| Safety Features | Automatic Rotor Recognition (optional), Lid Lock with Mechanical & Electronic Interlock, Imbalance Detection, Over-Speed Protection, Over-Temperature Protection (for optional cooling models) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Product Origin | Domestic |
| Model | TDZ5-WS |
| Price | USD 600 (approx.) |
| Type | Low-Speed Centrifuge |
| Max Capacity | 4 × 100 mL |
| Max Speed | 5000 rpm |
| Max RCF | 4800 × g |
| Dimensions (L×W×H) | 500 × 450 × 280 mm |
| Weight | 25 kg |
| Motor | Brushless AC Inverter Motor |
| Display | TFT True-Color Touchscreen |
| Programs | 20 Stored Protocols |
| Acceleration/Deceleration | 10 Adjustable Ramp Profiles |
| Noise Level | ≤65 dB(A) |
| Construction | All-Steel Frame with Stainless Steel Rotor Chamber |
| Safety | Electromechanical Door Lock, Automatic Rotor Imbalance Detection, Multi-Stage Vibration Damping System |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TDZ6-WS |
| Price | USD 700 (approx.) |
| Centrifugation Class | Biological Macromolecules |
| Maximum Capacity | 4 × 250 mL |
| Maximum Speed | 6000 rpm |
| Dimensions | 600 × 540 × 360 mm |
| Maximum RCF | 5150 × g |
| Timer Range | 0–99 h 59 min / Continuous / Short Spin |
| Power Consumption | 500 W |
| Noise Level | ≤65 dB(A) |
| Net Weight | 35 kg |
| Voltage/Frequency | AC 220 V, 50 Hz |
| Rotor Options | Horizontal (4×250 mL, 4×100 mL, 32×15 mL, 48/76×vacutainer), Angular (12×10 mL), Microplate (2×2×96-well) |
| Drive System | Brushless Frequency-Controlled Motor |
| Control Interface | TFT True-Color Touchscreen Display |
| Programmability | 20 User-Defined Protocols |
| Acceleration/Deceleration Profiles | 10 Adjustable Ramp Rates |
| Safety Features | Motorized Interlocked Door, Automatic Rotor Imbalance Detection, Dual Mechanical & Electronic Balance Compensation |
| Construction | Full Steel Frame, Stainless Steel Chamber |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | TG16MW |
| Quotation | USD 520 (FOB) |
| Centrifugation Class | Biomacromolecules |
| Maximum Capacity | 12 × 10 mL |
| Maximum Speed | 16,500 rpm |
| Dimensions | 380 × 260 × 310 mm |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | TGL-16G |
| Price | USD 495 (FOB Beijing) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TGL-16M |
| Pricing | Available Upon Request |
| Speed Range | 10,000–30,000 rpm (rated max: 16,000 rpm) |
| Max RCF | 19,800 × g |
| Temperature Control | −20 °C to +40 °C |
| Timer Range | 0–99 min |
| Power Supply | AC 220 V, 50 Hz, 15 A |
| Dimensions (L×W×H) | 600 × 470 × 330 mm |
| Weight | 70 kg |
| Rotor Configurations | No.1 Angle Rotor (1.5 mL × 12, 16,000 rpm, 17,800 × g) |
| Max Speed | 20,000 rpm |
|---|---|
| Max RCF | 27,800 × g |
| Max Capacity | 6 × 500 mL |
| Speed Accuracy | ±50 rpm |
| Temperature Range | −20 to +40 °C |
| Temp. Accuracy | ±1 °C |
| Timer Range | 0–99 min |
| Power Supply | AC 220 V, 50 Hz, 15 A |
| Dimensions (L×W×H) | 600 × 470 × 300 mm |
| Weight | 85 kg |
| Rotors | 1.5 mL × 12 (16,000 rpm, 17,800 × g), 1.5 mL × 24 (16,000 rpm, 23,755 × g), 5 mL × 10 (13,000 rpm, 11,400 × g), 2 × 48-well microplate (3,000 rpm, 1,400 × g), 10 mL × 8 (6,000 rpm, 3,200 × g) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | TGL20MW |
| Price | ¥27,800 |
| Type | High-Speed Refrigerated Centrifuge (10,000–30,000 rpm) |
| Separation Class | Biological Macromolecules |
| Max Capacity | 4 × 300 mL |
| Max Speed | 20,600 rpm |
| Dimensions | 630 × 760 × 400 mm |
| Max RCF | 29,400 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp Control Accuracy | ±1 °C |
| Acceleration/Deceleration | 10 selectable rates |
| Noise Level | ≤65 dB(A) |
| Power | 1.8 kW |
| Timer Range | 0–99 h 59 min |
| Weight | 110 kg |
| Rotor Recognition | Automatic |
| Display | TFT color touch LCD |
| Drive System | Brushless AC frequency-converter motor with dsPIC30F microcontroller and FSBB30CH driver module |
| Safety Features | Overspeed, overtemperature, imbalance, triple-layer steel rotor protection, active standby cooling, mechanical/electronic door interlock |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Primo / Primo R |
| Centrifuge Type | Benchtop Refrigerated Centrifuge |
| Maximum Speed | 15,000 rpm |
| Maximum RCF | 21,885 × g |
| Maximum Capacity | 4 × 100 mL |
| Temperature Range | –9 °C to 40 °C |
| Acceleration/Deceleration Steps | 9 acceleration / 2 deceleration profiles |
| Noise Level | < 62 dBA |
| Timer Range | 0–9 h 59 min + continuous mode |
| Drive System | Brushless DC motor |
| Control System | EASYcontrol II microprocessor-based interface |
| Rotor Recognition | Automatic |
| Imbalance Detection | Electronic, real-time, rotor-agnostic |
| Safety Certification | EN 61010-1, EN 61010-2-020, EN 50081-1, EN 50082-1, UVV VBG 7z |
| Dimensions (H×W×D) | 315 × 380 × 475 mm |
| Weight | 40 kg |
| Power Consumption | 350 W |
| Construction | Stainless steel base, reinforced aluminum chamber |
| Rotor Compatibility | Fixed-angle (6 × 15/50 mL Falcon), horizontal (4 × 100 mL DIN, 4 × 15/50 mL Falcon, 12 × 7/15 mL blood tubes) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Floor-standing centrifuge |
| Category | Blood bank centrifuge |
| Rotor configuration | Horizontal (swing-out) rotor |
| Maximum capacity | 8 × 550 mL blood bags |
| Maximum speed | 5,000 rpm |
| Maximum RCF | 7,295 × g |
| Dimensions (W × D × H) | 1015 × 816 × 900 mm |
| Speed range | High-speed (up to 5,000 rpm) |
| Application class | Cellular/bacterial separation |
| Compliance | IEC 61010-1, ISO 13485, FDA 21 CFR Part 11 (software-enabled), EU MDR Annex I |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Heraeus Biofuge Primo R |
| Drive System | Brushless Motor |
| Control System | EASYcontrol II Microprocessor |
| Max Speed | 15,000 rpm |
| Min Speed | 300 rpm |
| Max RCF | 21,885 × g |
| Temperature Range | –9 to +40 °C |
| Acceleration/Deceleration Steps | 9 / 2 |
| Timer | 0–9 h 59 min or Continuous |
| Noise Level | < 60 dBA |
| Max Capacity | 6 × 50 mL (fixed-angle), 4 × 100 mL (swing-bucket), 12 × 7–15 mL (blood tubes) |
| Rotor Recognition | Automatic |
| Imbalance Detection | Electronic, universal across all rotors |
| Program Memory | Stores most recent run parameters |
| Dimensions (H×W×D) | 313 × 580 × 493 mm |
| Weight | 69.5 kg |
| Power Consumption | 490 W |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 50081-1, EN 50082-1, UVV VBG 7z |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Legend X1/X1R & XT/XTR |
| Max Rotor Capacity | 4×1000 mL (XT/XTR) / 4×750 mL (X1/X1R) |
| Max Speed | 15,200 rpm |
| Max RCF | 25,830 ×g |
| Temperature Range | –10 °C to +40 °C (X1R/XTR only) |
| Refrigeration | CFC-free compressor-based cooling |
| Drive System | Brushless DC induction motor |
| Rotor Locking | Auto-Lock® III |
| Biosafety | ClickSeal® sealed bucket system |
| Rotor Material | Fiberlite® carbon-fiber composites |
| Control System | SMARTSpin® microprocessor-based interface |
| Programs | 99 stored methods (5 quick-access) |
| Acceleration/Deceleration Profiles | 9/10 selectable |
| Max Run Time | 9 h 59 min + continuous mode |
| Noise Level | <61 dBA (X1), <55 dBA (X1R), <57 dBA (XT/XTR) |
| Chamber | Stainless steel |
| Compliance | IEC 61010-1, IEC 61010-2-020, ISO 13485 (manufacturing), FDA 21 CFR Part 11-ready software architecture |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Biofuge Stratos |
| Instrument Type | Benchtop Centrifuge |
| Category | High-Speed Refrigerated Centrifuge (>30,000 rpm equivalent performance) |
| Max Speed | 23,300 rpm |
| Max RCF | 50,377 × g |
| Max Capacity | 4 × 180 mL |
| Temperature Range | −9 °C to +40 °C |
| Dimensions (H×W×D) | 395 × 640 × 595 mm |
| Drive System | Brushless Motor with Spindle Shaft Architecture |
| Acceleration/Deceleration Steps | 9 each |
| Programmable Protocols | 9 user programs + 1 pre-cool program |
| Noise Level | <60 dB(A) |
| Power Consumption | 1400 W (including 900 W refrigeration system) |
| Safety | Dual interlocked door system, real-time electronic imbalance detection, automatic rotor recognition |
| Control System | EASYcontrol™ II microprocessor-based interface |
| Rotor Compatibility | Fixed-angle, swing-bucket, microplate, and high-capacity vertical rotors (including bio-containment-certified variants) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Espresso |
| Type | Benchtop Microcentrifuge |
| Max Speed | 15,000 rpm |
| Relative Centrifugal Force (RCF) | Up to 17,000 × g |
| Rotor Capacity | 24 × 1.5/2.0 mL tubes |
| Temperature Range | Ambient only (non-refrigerated) |
| Control Interface | Digital LED display with intuitive push-button operation |
| Safety Compliance | IEC 61010-1, UL 61010-1 |
| Dimensions (W×D×H) | 20.3 × 25.4 × 19.7 cm |
| Weight | 4.5 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Heraeus Biofuge Primo |
| Maximum Speed | 15,000 rpm |
| Minimum Speed | 300 rpm |
| RCF Max | 21,885 × g |
| Capacity | 6 × 50 mL (fixed-angle), 4 × 100 mL (swing-bucket) |
| Temperature Range | Ambient |
| Acceleration/Deceleration Steps | 9 / 2 |
| Noise Level | < 62 dBA |
| Timer Range | 0–9 h 59 min + continuous |
| Drive System | Brushless DC motor |
| Control System | EASYcontrol II microprocessor-based interface |
| Rotor Recognition | Automatic |
| Imbalance Detection | Electronic, rotor-agnostic |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 50081-1, EN 50082-1, UVV VBG 7z |
| Dimensions (H×W×D) | 315 × 380 × 475 mm |
| Weight | 40 kg |
| Power Input | 350 W |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Labofuge 400 R |
| Instrument Type | Benchtop Centrifuge |
| Category | Refrigerated High-Speed Centrifuge |
| Max Speed | 11,500 rpm |
| Max RCF | 12,568 × g |
| Max Capacity | 4 × 180 mL |
| Dimensions (H×W×D) | 310 × 436 × 568 mm |
| Noise Level | ≤ 58 dB(A) |
| Drive System | Brushless Direct-Drive Motor |
| Control System | Microprocessor-Based with Backlit LED Display |
| Timer Range | 1–99 min, plus Short Spin & Continuous Modes |
| Safety Features | Rotor Overspeed Protection, Imbalance Detection, Self-Diagnostic Routine, CAMR-Certified Biocontainment Lid |
| Cooling System | Air-Cooled Refrigeration |
| Acceleration/Deceleration Times | 15–25 s (varies by rotor) |
| Rotor Options | 24 × 1.5 mL Fixed-Angle, 4 × 180 mL Horizontal, 18 × 15 mL Fixed-Angle, Hematocrit, Microplate, and Cytospin-Compatible Rotors |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Heraeus Megafuge 11 |
| Max Speed (Fixed-Angle Rotor) | 14,600 rpm (23,113 × g) |
| Max Speed (Swing-Bucket Rotor) | 4,100 rpm (3,176 × g) |
| Max Capacity (Fixed-Angle) | 6 × 100 mL / 30 × 15 mL / 60 × 2 mL |
| Max Capacity (Swing-Bucket) | 4 × 280 mL / 16 × 50 mL conical tubes / 60 × 5–7 mL vacutainers / 2 × 3-well microplates |
| Drive System | Brushless DC motor |
| Refrigeration (Megafuge 11R) | CFC-free compressor-based cooling |
| Dimensions (Megafuge 11) | 37 × 40 × 50 cm (H×W×D) |
| Dimensions (Megafuge 11R) | 37 × 57 × 60 cm |
| Weight (Megafuge 11) | 40 kg |
| Weight (Megafuge 11R) | 72 kg |
| Timer Range | 1–99 min + continuous mode |
| Acceleration/Deceleration Profiles | 5-step ramp control + inertia brake |
| Power Consumption (Megafuge 11) | 350 W avg / 500 W peak |
| Power Consumption (Megafuge 11R) | 550 W avg / 800 W peak |
| Safety Certification | CAMR-compliant biocontainment rotors available |
| Compliance | Meets IEC 61010-2-020 for laboratory centrifuges |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Heraeus Multifuge 1 |
| Type | Ventilated or Refrigerated |
| Control Options | EASYset (touch-button) or QUIKset (rotary dial) |
| Max RCF | 24,652 × g |
| Max Speed | 15,000 rpm |
| Max Capacity | 1.6 L (e.g., 4 × 400 mL or 56 × 7 mL tubes) |
| Temperature Range (refrigerated) | –9 to +40 °C |
| Acceleration/Deceleration Steps | 9 / 9 |
| Noise Level | <64 dB(A) (ventilated), <54 dB(A) (refrigerated) |
| Dimensions (H×W×D) | 365 × 500 × 615 mm (1 S/L) |
| Weight | 92 kg (1 S/L), 118 kg (1 S-R/L-R) |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 50081-1, EN 50082-1 |
| Certification | CAMR-approved |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | MicroCL 17 / MicroCL 21 |
| Maximum RCF | 17,000 × g / 21,000 × g |
| Acceleration/Deceleration Time | ≈12 s (typical) |
| Rotor Compatibility | 24-position fixed-angle rotor (1.5–2.0 mL), 18-position dual-row rotor (0.5 + 2.0 mL), high-capacity PCR rotor (0.2–0.5 mL and capillary tubes) |
| Safety Certification | IEC 61010-2-020 compliant |
| Rotor Material | Anodized aluminum with autoclavable ClickSeal™ biocontainment lid |
| Display | Backlit LCD with intuitive keypad interface |
| Dimensions (W × D × H) | 22.9 × 30.5 × 22.9 cm |
| Weight | 12.7 kg |