| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Mars-400 Plus |
| Instrument Type | Portable GC-MS |
| Mass Range | 15–550 amu |
| Mass Resolution | Unit mass resolution |
| Detection Limit | < ppb (for selected VOCs/SVOCs) |
| Maximum Scan Rate | 10,000 amu/s |
| Sensitivity | Optimized for trace-level detection in field conditions |
| Weight | 17 kg |
| Power Supply | Integrated rechargeable battery pack |
| Carrier Gas | Built-in helium or hydrogen micro-gas cylinder (optional) |
| Brand | Masa |
|---|---|
| Origin | Slovakia |
| Model | MCCGC-AIMS |
| Sample Introduction | Automated |
| Sensitivity | ppb to ppt |
| Library | VOCs, Explosives |
| Operating Pressure | 600–1200 mbar |
| Drift Gas Flow | 500–1200 mL/min |
| Sample Gas Flow | 2–500 mL/min |
| Drift Field Strength | 200–560 V/cm |
| Polarity | Positive/Negative |
| Ionization Source | Corona Discharge (Non-radioactive) |
| Pre-separation GC | Multi-Capillary Column Gas Chromatograph |
| IMS Temperature Range | 30–140 °C |
| Resolution (FWHM) | 90–100 (N₂/air) |
| Power Supply | 250 V / 24 V |
| Communication | TCP/IP, USB 2.0 |
| Dimensions (mm) | 490 × 390 × 150 |
| Brand | MassTech |
|---|---|
| Origin | USA |
| Model | UHR, HR |
| Instrument Type | Atmospheric Pressure Ion Source |
| Sensitivity | Attomole-level (sub-fmol/µL) |
| Spatial Resolution | <5 µm |
| Mass Range | Determined by Coupled Mass Analyzer |
| Accurate Mass Capability | Dependent on Host Mass Spectrometer |
| Brand | MassTech (ASPEC as authorized distributor) |
|---|---|
| Origin | USA |
| Instrument Type | 3D Ion Trap Mass Spectrometer |
| Model | MT50 |
| Mass Range | 30–2500 amu |
| Sensitivity | 50 pg/µL reserpine, S/N ≥ 10:1 |
| Resolution | 6000 (FWHM at m/z 400) |
| Mass Accuracy | ±0.3 amu |
| Scan Speed | 1000–8000 amu/s or up to 5 spectra/sec |
| Ionization Compatibility | ESI, oESI, 2ndESI, APCI, DART, AP/MALDI |
| Power Input | 90–240 VAC, 50/60 Hz |
| Power Consumption | 250–300 W |
| Dimensions (L×W×H) | 51 × 43 × 30 cm |
| Weight | <35 kg |
| Operating Mode | MS¹ and MSⁿ (up to MS⁵) |
| Polarity | Positive/Negative Switchable |
| Gas Requirement | None (gas-free operation) |
| Transport | Shock-damped wheeled case |
| Brand | LabTech |
|---|---|
| Model | MAX-S |
| Principle | Catalytic Thermal Decomposition–Gold Amalgamation–Cold Vapor Atomic Absorption Spectrometry (CV-AAS) |
| Detection Limit | 0.0005 ng Hg |
| Linear Range | 0–30,000 ng Hg (7 orders of magnitude) |
| Analysis Time | 2–5 min per sample |
| Sample Forms | Solid, liquid, and gas matrices without pretreatment |
| Repeatability | RSD < 3% (n = 10 at 10 ng level) |
| Calibration Stability | 3–6 months between standard curve verification |
| Compliance | Designed for GLP/GMP environments |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MaxiDirect |
| Pricing | Upon Request |
| Heating Temperature | Ambient to 300 °C |
|---|---|
| Heater Type | Band Heater |
| Sample Volume Capacity | ≤20 mL |
| Carrier Gas | Dry Nitrogen or Dry Air |
| Gas Flow Rate | 0–300 L/min |
| Maximum Gas Pressure | ≤0.8 MPa |
| Nitrogen Purity | ≥99.99% (High-Purity Grade) |
| Desiccant | 100 g Molecular Sieve |
| Safety Protections | Overtemperature Protection, Overpressure Gas Safety Cut-off |
| Power Supply | AC 100–240 V, 50/60 Hz, 100 W |
| Brand | MAYZUM |
|---|---|
| Model | MAY-2001NC |
| Measurement Principle | Vibrational Density-based Electrochemical Correlation |
| Measured Parameters | Density (g/cm³), Temperature (°C), NaOCl Concentration (% w/w), Baumé (°Bé) |
| Density Range | 0–2.2 g/cm³ |
| Concentration Range | 0.1–114.62% |
| Resolution | 0.001 g/cm³ / 0.1 °C / 0.1% / 0.1 °Bé (standard) |
| Accuracy | ±0.002 g/cm³ / ±0.5% / ±0.5 °Bé (standard) |
| Temp. Compensation | Automatic, 0–80 °C integrated Pt100 sensor |
| Operating Temp. | −20 to +120 °C (process), −20 to +80 °C (ambient) |
| Pressure Rating | ≤20 MPa |
| Enclosure Rating | IP67 |
| Electrical Interface | M12×1.5 (probe), M16×1.5 (controller) |
| Output Options | 4–20 mA analog, RS485/RS232 digital, dual-channel relay alarms |
| Power Supply | 24 V DC |
| Wetted Materials | PTFE flange, Hastelloy C-276 with PTFE lining |
| Explosion Protection | Ex ia IIB T6 Ga (optional) |
| Data Storage | SQLite database, up to 16 GB |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Ir100-AC |
| Type | Online NIR Analyzer |
| Wavelength Range | 4-channel NIR |
| Scan Speed | 30 ms |
| Moisture Range | 0.1–70% w/w |
| Resolution | 0.01% |
| Accuracy | ±0.2% (matrix-dependent) |
| Housing Material | SS316L |
| IP Rating | IP65 |
| Operating Temperature | −10 to 50 °C |
| Humidity Range | 10–90% RH |
| Power Supply | DC 24 V, 2 A |
| Output Interfaces | TCP/IP, RS485/RS232, Digital Alarm Outputs (2 channels) |
| Probe Cable Length | Standard 5 m (extendable to 100 m) |
| Installation Distance | 250 ± 100 mm (non-contact transmission mode) |
| Weight | ≈9.8 kg |
| Dimensions | 130 × 360 × 160 mm |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Mw100-AJ |
| Measurement Principle | Microwave Attenuation & Resonance Frequency Shift |
| Moisture Range | 100 ppm – 99.99% (w/w) |
| Resolution | 50 ppm |
| Probe Length | 150 mm / 1 m (customizable) |
| Cable Length | Standard 5 m (up to 100 m) |
| Operating Temp. | −10 °C to +90 °C (wetted parts rated to 100 °C) |
| Pressure Rating | ≤ 4.0 MPa |
| Wetted Materials | SS316L, Hastelloy C, PTFE, Monel 400 |
| Process Connections | Flanged, threaded, sanitary clamp, non-contact through-glass |
| Output Signals | TCP/IP, RS485/232, dual relay alarms (HI/LO) |
| Enclosure Rating | IP68 |
| Explosion Protection | Ex db IIC T6 Gb |
| Power Supply | 220 V AC, <100 mA |
| Dimensions | 280 × 485 × 590 mm |
| Weight | ≈ 5 kg |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Mw201 |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Certifications | IP67 ingress protection, ATEX/IECEx optional (explosion-proof variants available) |
| Measurement Principle | Continuous-wave microwave transmission & attenuation analysis |
| Measurement Range | 0.1–99.9% moisture content (w/w) |
| Resolution | 0.1% |
| Typical Accuracy | ±0.01–±0.2% (material- and installation-dependent) |
| Output Signals | RS485 (Modbus RTU), 4–20 mA analog, TCP/IP Ethernet |
| Data Logging | Onboard non-volatile memory with timestamped records (≥1 year at 1-min intervals) |
| Process Connection Options | Flanged, sanitary clamp (DIN 11851), NPT threaded, insertion probe, or through-pipe dual-port transmission |
| Housing Material | 316L stainless steel with electropolished finish |
| Operating Temperature | −20 °C to +65 °C ambient |
| Compliance | Meets IEC 61326-1 (EMC), IEC 61000-6-2/6-4, ISO/IEC 17025 traceable calibration support, FDA 21 CFR Part 11 ready (audit trail & electronic signature enabled in software) |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | MAZ-Ra300-Acr |
| Instrument Type | Online Raman Spectrometer |
| Spectral Resolution | 6 cm⁻¹ |
| Concentration Range | 0.1–99.9% |
| Resolution | 0.01% |
| Probe Length | 150 mm / 1 m (customizable) |
| Cable Length | Standard 5 m (extendable to 100 m) |
| Operating Temperature | −10 to 130 °C |
| Wetted Materials | Hastelloy C / PTFE / M400 / Non-contact optical path |
| Process Connection Options | Non-contact direct irradiation, immersion flange, sanitary clamp, NPT thread, flow cell |
| Power Supply | 220 V AC, <0.2 A |
| Output Interfaces | TCP/IP, RS-485/232 (digital), dual-channel relay (alarm & limit control) |
| IP Rating (wetted parts) | IP67 |
| Max Pressure Rating | ≤1 MPa |
| Net Weight | ≈5 kg |
| Dimensions | 280 × 485 × 590 mm (L×W×H) |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MAZ-Ra300-BSJZ |
| Instrument Type | Online Raman Spectrometer |
| Spectral Resolution | 6 cm⁻¹ |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Sc201 |
| Measurement Principle | Microwave Dielectric Absorption |
| Accuracy | ±0.3% (typical, dependent on matrix) |
| Resolution | 0.1% |
| Operating Temperature (wetted probe) | up to 120 °C |
| Pressure Rating (wetted probe) | up to 4.0 MPa |
| Output Interfaces | RS485 (Modbus RTU), 4–20 mA analog, TCP/IP Ethernet |
| Installation Options | Flanged contact probe or non-contact over-the-pipe configuration |
| Multi-channel Capability | Supports “one master → multiple slave” topology for cost-effective multi-point monitoring |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC016-6400A |
| Pricing | Available Upon Request |
| Sensitivity | K: 1 µg/mL for full-scale deflection |
| Na | 1 µg/mL for full-scale deflection |
| Repeatability | ≤2 scale divisions across 7 consecutive measurements of identical sample |
| Stability | ≤1 scale division drift over 15 s continuous aspiration |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC016-721 |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC016-722 |
| Pricing | Available Upon Request |
| Wavelength Range | 330–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 1 nm |
| Spectral Bandwidth | 4 nm |
| Transmittance Accuracy | ±0.5%T |
| Transmittance Repeatability | 0.2%T |
| Transmittance Range | 0.0–125%T |
| Absorbance Range | −0.301 to 1.999 A |
| Concentration Display Range | 0–1999 units |
| Stray Light | ≤0.5%T at 360 nm |
| Photometric Stability | ±0.003 A/h |
| Interface | RS-232 bidirectional serial port |
| Software Compatibility | SPD application software (Windows OS) |
| Data Functions | Photometric (T/A), Quantitative (C/F), Time Scan |
| Printer Support | Yes |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC016-723PC |
| Pricing | Upon Request |
| Wavelength Range | 320–1000 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.5 nm |
| Spectral Bandwidth | 2 nm |
| Transmittance Accuracy | ±0.5%T |
| Transmittance Repeatability | 0.2%T |
| Transmittance Range | 0.0–125%T |
| Absorbance Range | −0.097–2.5 A |
| Concentration Display Range | 0–99999 |
| Stray Light | ≤0.5%T @ 360 nm |
| Photometric Stability | ±0.002 A/h |
| Interface | RS-232 bidirectional serial port |
| Software | SPD application software for Windows |
| Printer Support | Integrated thermal printer |
| Measurement Modes | T (%T), A (Abs), C (Concentration), F (Factor) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC016-752 |
| Pricing | Available Upon Request |
| Wavelength Drive | Manual |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 1 nm |
| Spectral Bandwidth | 4 nm |
| Transmittance Accuracy | ±0.5%T |
| Transmittance Repeatability | 0.2%T |
| Transmittance Range | 0.0–125%T |
| Absorbance Range | −0.301 to 1.999 A |
| Concentration Display Range | 0–1999 units |
| Stray Light | ≤0.5%T at 220 nm and 360 nm |
| Photometric Stability | ±0.003 A/h |
| Interface | RS-232 bidirectional serial port |
| Printer Support | Yes |
| Software Compatibility | SPD application software for Windows (T/A/C/F modes, kinetic scanning, data logging) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC016-754PC(UV-2100 Export Model) |
| Pricing | Available Upon Request |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 1 nm |
| Spectral Bandwidth | 4 nm |
| Photometric Accuracy (Transmittance) | ±0.5%T |
| Photometric Repeatability (Transmittance) | 0.2%T |
| Transmittance Range | 0.0–125%T |
| Absorbance Range | –0.097 to 2.5 A |
| Concentration Display Range | 0–99999 |
| Stray Light | ≤0.5%T at 220 nm and 360 nm |
| Baseline Stability | ±0.002 A/h |
| Interface | RS-232 Bidirectional Serial Port |
| Software | SPD Application Suite for Windows |
| Printer Support | Integrated Thermal or Dot-Matrix via RS-232 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC016-AA320CRT |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC016-YRWFX-210 |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC017-CS-8510 |
| Pricing | Available Upon Request |
| Carbon Range | 0.001–6.0000 wt% (expandable to 99.999%) |
| Sulfur Range | 0.0005–0.3500 wt% (expandable to 99.999%) |
| Analysis Time | 25–60 s (typ. 35 s) |
| Balance Capacity | 0–300 g |
| Balance Resolution | 0.001 g |
| Operating Temp. | 10–30 °C |
| Relative Humidity | <75% RH |
| Power Supply | AC 220 V ±5%, 50 Hz ±2%, Grounded |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC017-CS-8800 |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC017-CS-H60D |
| Pricing | Available Upon Request |
| [Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Domestic |
| Detector Type | Charge-Coupled Device (CCD) |
| Channel Capacity | Up to 64 optical channels |
| Wavelength Range | 160–650 nm |
| Excitation Frequency | 200–600 Hz |
| Analytical Reproducibility | RSD ≤ 0.2% |
| Grating Radius | 1000 mm |
| Groove Density | 1667 lines/mm |
| Entrance Angle | 35° |
| Sample Gap | 4 mm |
| PMT Voltage Range | –550 V to –1000 V (8-step digital adjustment) |
| Thermal Stability | 35 °C ± 0.5 °C (localized spectrometer chamber)] |
| Brand | McPherson |
|---|---|
| Origin | USA |
| Model | 234/302 |
| Optical Configuration | Seya-Namioka (S-N) |
| Wavelength Range | 30–2200 nm |
| Resolution | 0.1 nm |
| Focal Length | 2000 mm |
| Brand | McPherson |
|---|---|
| Origin | USA |
| Model | Model 218 |
| Focal Length | 300 mm |
| Optical Design | Crossed Czerny-Turner |
| Beam Angle (Input/Output) | 44° |
| f/# | f/5.3 |
| Grating Size | 50 × 50 mm |
| Wavelength Accuracy | ±0.10 nm (mechanical counter, 1200 grooves/mm grating) |
| Wavelength Repeatability | ±0.005 nm (1200 grooves/mm grating) |
| Focal Plane Width | up to 17 mm |
| Wavelength Range | configurable per grating selection (VUV to LWIR) |
| Brand | McPherson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 234/302 |
| Pricing | Upon Request |
| Focal Length | 200 mm |
| Optical Design | Modified Seya-Namioka |
| f/# | 4.5 |
| Grating Size | 40 × 45 mm |
| Wavelength Accuracy | ±0.10 nm (with 1200 g/mm grating) |
| Wavelength Repeatability | ±0.05 nm (with 1200 g/mm grating) |
| Slit-to-Slit Working Distance | 229 mm |
| Input/Output Beam Angle | 64° or 180° selectable |
| Focal Plane Width | 25 mm |
| Focal Plane Tilt | ~30° |
| Grating Options | 300–2400 g/mm |
| Resolution @ 313.1 nm | 0.06–0.3 nm (dependent on grating) |
| Reciprocal Linear Dispersion | 2–816 nm/mm |
| Detector Interface | CCD or MCP imaging array |
| Vacuum Compatibility | Standard UHV option (10⁻¹⁰ Torr with all-metal seals) |
| Residual Gas Analysis | Performed pre-shipment |
| Brand | McPherson |
|---|---|
| Origin | USA |
| Model | 248/310G |
| Wavelength Range | <1 nm to 310 nm |
| Spectral Resolution | 0.018 nm |
| Focal Length | 1000 mm |
| Optical Design | Grazing Incidence |
| Scanning Capability | Yes |
| Multichannel Detection Support | Yes |
| Compliance | Designed for UHV and synchrotron beamline integration |
| Detector Interface | Standard NIM & TTL-compatible output |