Differential Scanning Calorimeter
Filter
Showing 151–180 of 207 results
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris Classic |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −170 °C to 600 °C |
| Heating/Cooling Rate | 0.001–100 K/min |
| Temperature Accuracy | ±0.1 K (intrinsic) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris Supreme-H |
| Instrument Type | Differential Scanning Calorimeter |
| Temperature Range | −180 °C to 750 °C |
| Heating/Cooling Rate | 0 to 200 K/min |
| Module Architecture | Interchangeable Multi-Module Platform |
| Compliance | GLP, GMP, FDA 21 CFR Part 11 (with optional software package) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris® Select-P |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –170 to 600 °C |
| Heating/Cooling Rate | 0 to 500 K/min |
| Compliance | GLP/GMP, FDA 21 CFR Part 11 (software-enabled), ISO 11357, ASTM E794, ASTM E1356 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Instrument Type | DSC |
| Temperature Range | −170 to 650 °C |
| Heating/Cooling Rate | 0–100 K/min |
| Module Configuration | Sensor + Furnace Assembly (S-Module) |
| Compliance | GLP/GMP, FDA 21 CFR Part 11 (with optional software package) |
| Key Software Features | BeFlat®, Tau-R Correction, TM-DSC (optional), Automatic Baseline Subtraction, Crystallinity Calculation, Cp Measurement |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 3500 Sirius |
| Temperature Range | −170 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0–100 K/min |
| Sample Capacity (with ASC) | Up to 20 positions (samples + references) |
| Instrument Type | Differential Scanning Calorimeter |
| 炉 Body Material | Silver-based furnace block |
| Sensor Architecture | Monolithic sensor design |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 3500 Sirius |
| Temperature Range | −170 °C to 600 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0.001–100 K/min (temperature-dependent) |
| Sensor Type | Heat-Flow |
| Calorimetric Range | ±650 mW |
| Enthalpy Accuracy | ±1% (vs. certified metals) |
| Atmosphere Options | Oxidizing or inert (static/dynamic) |
| ASC Capacity | Up to 20 sample/reference positions (optional) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 404 F1 Pegasus |
| Temperature Range | −150 to 2000 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–50 K/min |
| Sensor Types | Replaceable DSC (−150 to 1650 °C) and DTA (up to 2000 °C) |
| Vacuum Capability | High-vacuum sealed system |
| Gas Control | Integrated stainless-steel gas lines with metal-encapsulated mass flow controllers (MFCs) |
| Optional Automation | Stepper-motor-driven dual-furnace configuration and 20-position auto-sampler |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 404 F1 |
| Temperature Range | −150 °C to 1000 °C (extendable to 2000 °C with optional furnaces) |
| Heating/Cooling Rate | 0.001–50 K/min (up to 20 K/min for Rh furnace) |
| Vacuum Capability | Down to 10⁻⁴ mbar |
| Sensor Types | DSC (Cp-optimized up to 1600 °C), DTA (up to 2000 °C with W/Re thermocouples) |
| Compliance | ASTM E793, E1269, ISO 11357, USP <1158>, GLP/GMP-ready with audit trail (Proteus® software) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 404 F3 Pegasus |
| Temperature Range | −150 to 2000 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–50 K/min |
| Brand | NANJING DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Model | DSC 100A |
| Sample Capacity | Single-sample |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Accuracy | ±0.01 °C |
| DSC Signal Range | 0–±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| DSC Noise Level | 0.01 μW |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 μW |
| Temperature Repeatability | ±0.1 °C |
| Gas Flow Control | Digital Mass Flow Controller |
| Interface | USB 2.0 Bidirectional Communication |
| Display | 7-inch 24-bit Color TFT Touchscreen |
| Sensor Material | Corrosion-Resistant Alloy |
| Calibration | Onboard Standard Reference Materials with One-Touch Thermal & Enthalpy Calibration |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DSC 4000 / DSC 6000 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –100 °C to 600 °C (with optional cryogenic and high-temp accessories) |
| Temperature Accuracy | ±0.1 °C (traceable to NIST standards) |
| Heating/Cooling Rate | 0.1–100 K/min (programmable in 0.1 K/min increments) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DSC 8000 |
| Simultaneous Sample Capacity | Multiple |
| Instrument Type | Power-Compensated DSC |
| Temperature Range | –180 °C to 750 °C |
| Heating/Cooling Rate | 0.01 °C/min to 300 °C/min |
| Dynamic Heat Flow Range | ±800 mW |
| Furnace Material | Platinum-Iridium Alloy |
| Modulated DSC (MDSC®) | Standard |
| Cooling Options | Two-stage mechanical cooler, three-stage mechanical cooler, automated liquid nitrogen cooling |
| Dual Digital Mass Flow Controllers | Standard |
| Optional Accessories | 96-position autosampler, high-pressure cell (up to 600 psi), UV photo-DSC module, isolated sample chamber for hazardous materials |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Model | DSC 8500 |
| Temperature Range | –180 °C to 750 °C |
| Heating/Cooling Rate | up to 750 K/min (controlled), >1000 K/min (free cooling) |
| Heat Flow Dynamic Range | ±800 mW |
| Calorimetric Accuracy | < ±0.2% |
| Sensitivity | 0.18 µW |
| Data Acquisition Rate | up to 100 Hz |
| Standard Features | Dual-channel digital mass flow controllers, automated lid, integrated cooling accessory |
| Optional Accessories | 96-position autosampler, high-pressure DSC cell, isolated DSC module, photo-DSC unit, DSC–Raman hyphenated system |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DSC-790 |
| Sample Capacity | Single |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | −150 °C to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| DSC Heat Flow Range | ±6000 mW |
| Cooling Options | Liquid Nitrogen, Mechanical, or Ambient Air |
| Heating Rate | 0.01–100 °C/min |
| Heat Flow Resolution | 0.1 µW |
| Calorimetric Accuracy | ±0.1% |
| Calorimetric Precision | ±0.1% |
| Atmosphere Control | Dual-gas inlet with software-driven automatic switching |
| Dimensions (W×D×H) | 950 mm × 555 mm × 360 mm |
| Weight | 30 kg |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Instrument Type | DSC |
| Temperature Range | Ambient to 1500 °C |
| Manufacturer Status | Authorized Distributor (Non-OEM) |
| Origin Category | Imported Instrument |
| Model | DSC8271 |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Instrument Type | DSC |
| Temperature Range | −170 °C to 725 °C |
| Configuration | Imported System |
| Distribution Model | Authorized Distributor |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | DSCvesta2 |
| Temperature Range | –180 to 725 °C (atmospheric: RT to 600 °C |
| mechanical cooling | –95 to 725 °C) |
| Heating/Cooling Rate | up to 100 °C/min |
| Gas Flow Range | 0–250 mL/min (resolution: 1 mL/min) |
| Heat Flow Range | ±1000 mW |
| Noise Level | < 0.05 µW |
| Baseline Repeatability (–70 to 300 °C) | ≤ 10 µW |
| Enthalpy Sensitivity | 0.1 µW |
| Sensor Type | Heat-Flow-Type Metallic Sensor with vestaeye® Self-Diagnostic Function |
| Furnace Material | Pure Silver or Pure Platinum |
| Calibration Standards | ≥5 Certified Reference Materials (including Indium, Zinc, Tin, Bismuth, Lead) |
| Software Features | Dual-data logging (raw + corrected), LIMS integration support, export to Word, Excel, JPG, PDF |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | TG-DTA8122 |
| Temperature Range | Ambient to 1100 °C (standard), up to 1500 °C (high-temperature option) |
| Heating Rate | Up to 100 °C/min |
| Balance System | Horizontal differential triple-coil design |
| Max. Sample Mass | 1 g |
| TG Full Scale | ±250 mg (500 mg FS) |
| TG Sensitivity | 0.01 µg |
| DTA Full Scale | ±1000 µV (2000 µV FS) |
| Atmosphere Options | Air, inert gas, vacuum, steam, controlled flow |
| Optional Autosampler | 24 sample positions + 3 reference + 5 calibration positions |
| Standard Operating Modes | Constant Reaction Control (CRC), Step Isothermal Analysis (SIA), Dynamic Rate Control (DRC) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | DSC8230 |
| Heating Rate | up to 150 °C/min |
| Cooling Rate | 400 °C → 50 °C in ≤4 min |
| Multi-unit Control | up to 8 units via single PC |
| Temperature Control | Pre-compensated PID with hold-mode overshoot correction |
| Calibration | Built-in temperature calibration function |
| Power Mode | ECO standby mode (30% energy reduction) |
| Software | Integrated thermal analysis suite with auto-diagnosis, dual-data backup, remote firmware update, and configurable end-of-run actions |
| Sample Automation | Optional ASC (Automatic Sample Changer), field-installable |
| Hybrid Capability | Compatible with simultaneous XRD-DSC coupling |
| Brand | SCINCO |
|---|---|
| Origin | USA |
| Model | DSC N-650 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −150 °C to 725 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Thermocouple Type | Type K |
| Heating/Cooling Rate | 0.1–200 °C/min |
| Baseline Stability | High |
| Heat Flow Sensor Noise Level | Low |
| Cooling Method | Optional Water Cooling |
| Sample Pan Enclosure | Sealed |
| Temperature Control | Dual-PID |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | 96line High-Temperature Specific Heat Analyzer |
| Temperature Range | Ambient to 2000 °C |
| Temperature Accuracy | ±0.5 °C (typical for high-temperature DSC-grade calibration) |
| Heating/Cooling Rate | 0.001–99 K/min |
| Sample Capacity (Calorimetry) | 5.7 mL (Ø14.5 mm × H35 mm) |
| Specific Heat Measurement Uncertainty | ≤1% (per ASTM E1269 & ISO 11357-4) |
| TGA Max Load | 100 g |
| TGA Resolution | 0.3 µg |
| TMA Range | ±6 mm |
| TMA Resolution | 1.6 nm |
| Modular Configurations | Simultaneous TG-DSC, TG-DTA, TMA, 3D Heat-Flow Calorimetry |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Alexsys 800 / Alexsys 1000 |
| Calorimetry Principle | Isothermal Heat-Flow Calvet |
| Temperature Range | 500–800 °C (Alexsys 800) / 800–1000 °C (Alexsys 1000) |
| Sample Crucible Count | 2 |
| Crucible Volume | 28 mL / 20 mL (dual configuration) |
| Temperature Accuracy | ±0.1% of reading |
| Calorimetric Accuracy | ±1% |
| Heat Flow Resolution | 12.5 µW |
| Dimensions (W × H) | 800 mm × 880 mm |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | BT2.15 |
| Temperature Range | –196 to +200 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–1 K/min |
| Detection Principle | 3D Calvet-type Heat Flow Calorimetry |
| Operating Modes | Isothermal & Non-Isothermal |
| Sample Environment | Open or Controlled-Atmosphere (including pressurized & mixing cells) |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | C80 |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.05 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% |
| Heat Flow Resolution | 0.10 µW |
| Maximum Sample Volume | 12.5 mL |
| Pressure Rating | Up to 1000 bar |
| Sensor Type | 3D Calvet Thermopile Array |
| Sample Cell Materials | Stainless Steel, Hastelloy C, or Custom Alloys |
| Cell Types | Ampoule, Flip-Mix, Membrane-Mix, Fluid Circulation, Liquid Heat Capacity, Vacuum, Adsorption, High-Pressure Pressure-Monitoring, and Safety Cells |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | C80 |
| Operating Modes | Isothermal & Scanning |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 0.001–2 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.05 °C |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% |
| Heat Flow Resolution | 0.10 µW |
| Maximum Sample Volume | 12.5 mL |
| Cell Materials | Stainless Steel or Hastelloy C |
| Maximum Pressure Rating | 1000 bar |
| Cell Types | Ampoule, Flip-Mix, Membrane-Mix, Fluid Circulation, Liquid Heat Capacity, Vacuum, Adsorption, High-Pressure Manometric, Safety Cells |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | C80 Microcalorimeter |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Calorimetric Resolution | 0.10 µW |
| Maximum Sample Volume | 12.5 mL |
| Maximum Pressure Rating | 1000 bar |
| Sensor Principle | Calvet-type 3D-sensor |
| Thermal Enthalpy Accuracy | ±1% |
| Calorimetric Accuracy | ±0.1% |
| Temperature Precision | ±0.05 °C |
| Sample Cell Materials | Stainless Steel or Hastelloy C |
| Operating Modes | Isothermal and Scanning |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | DRC |
| Type | Laboratory-scale differential reaction calorimeter with dual-jacketed vessels, isothermal operation mode, and real-time ΔT monitoring via platinum resistance thermometers |
| Measurement Principle | Differential temperature-based heat flow quantification using Joule-effect calibration |
| Key Outputs | Reaction enthalpy (ΔHᵣₓₙ), mixing enthalpy (ΔHₘᵢₓ), adiabatic temperature rise (ΔTₐd), time-to-maximum-rate (tₘₐₓ), heat capacity (Cₚ), kinetic profiling |
| Compliance | Designed for GLP-compliant thermal safety assessment per ISO 11358, ASTM E698, and ICH Q1A(R2) guidelines |
| Software | CALISTO™ v5.0 with 21 CFR Part 11–compliant audit trail, raw data export (CSV, ASCII), and customizable reporting templates |
| Sample Compatibility | Liquid–liquid, liquid–gas, and heterogeneous slurries (max. working volume: 500 mL per vessel) |
| Temperature Control | Dual-circulating bath integration (±0.02 °C stability) |
| Sensor Resolution | ±0.001 °C ΔT detection limit |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | DSC131 Evo |
| Temperature Range | −170 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.05 °C |
| Enthalpy Accuracy | ±2% |
| Heat Flow Precision | ±0.5% |
| Noise Level (at 200 °C) | 1.5 μW |
| Sensitivity (Indium Fusion) | 3 μV/mW |
| Dynamic Heat Flow Range | ±6000 mW |
| Time Constant | 3 s |
| Gas Control | Dual-gas switching capability |
| Pressure Rating (uncontrolled) | up to 500 bar (7255 psi) at 600 °C |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | DSC131 Evo |
| Temperature Range | −170 to 700 °C (LN₂ mode) / −80 to 500 °C (mechanical cooling) |
| Heating/Cooling Rate | 0–100 K/min |
| Dynamic Heat Flow Range | ±6000 mW |
| Gas Channels | 2 independent, software-controlled carrier gas lines |
| Pressure Rating | up to 500 bar with high-pressure crucibles |
| Sensor Type | removable heat-flux DSC sensor |
| Standard Software | CALISTO v5.x |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Labsys Evo-DSC |
| Temperature Range | Ambient to 1600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–100 K/min |
| Balance Max Capacity | 20 g |
| Balance Range | ±1000 mg |
| Balance Resolution | 0.02 µg |
| DSC Sensitivity | 0.4 µW (sensor-dependent) |
| Cp Measurement Uncertainty | <2% |
| Atmosphere Options | Inert, Oxidizing, Reducing, Static, Dynamic, Vacuum |
| Gas Control | 3 Mass-Flow-Controlled Carrier Gases + 1 Auxiliary/Reaction Gas |
| EGA Compatibility | MS, FT-IR, GC |
| Optional Autosampler | 25-position ASC |